{"title":"Transformers","description":"\u003cp\u003e\u003cspan\u003eGil Automation is a leading provider of transformers, offering a comprehensive range of high-quality products designed to meet the diverse needs of customers in various industries. Gil Automation transformers are known for their reliability, efficiency, and superior performance in power distribution and electrical systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eApplications: Gil Automation transformers find applications in various industries, including power generation, oil and gas, manufacturing, infrastructure, and commercial buildings. They are used in power distribution networks, substations, industrial processes, renewable energy systems, and other electrical installations.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"fluke-1623-2-basic-geo-earth-ground-tester","title":"Fluke 1623-2 Basic Geo Earth Ground Tester (non-Kit version)","description":"\u003ch2\u003eProduct overview: Fluke 1623-2 GEO Earth Ground Tester\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003eThe Fluke 1623-2 GEO Earth Ground Tester offers data storage and download capabilities via USB port. World class accessories will simplify and speed up testing time.\u003c\/p\u003e\n\u003cp\u003eFluke 1623-2 GEO Earth Ground Tester summary\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3- and 4-pole Fall-of-Potential, earth resistance loop testing\u003c\/li\u003e\n\u003cli\u003e4-pole Soil Resistivity testing\u003c\/li\u003e\n\u003cli\u003eSelective earth ground rod testing using 1 clamp\u003c\/li\u003e\n\u003cli\u003eStakeless earth ground rod testing using 2 clamps\u003c\/li\u003e\n\u003cli\u003eIP56 rated for outdoor use\u003c\/li\u003e\n\u003cli\u003eRugged carrying case\u003c\/li\u003e\n\u003cli\u003eUSB data storage and transfer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 1623-2 GEO Earth Ground Tester\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay: 1999 digit LCD\u003c\/td\u003e\n\u003ctd\u003eDisplay with special symbols, digit height 25 mm, fluorescent backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser interface\u003c\/td\u003e\n\u003ctd\u003eInstant measurement through TURN and START one button concept. The only operating elements are rotary switch and START button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRobust, water and dust resistant\u003c\/td\u003e\n\u003ctd\u003eInstrument is designed for tough environmental conditions (rubber protective cover, IP56)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eInternal memory storage up to 1500 records accessible via USB port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eTemperature Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to 50°C (14°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to 60°C (-22°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd\u003e±0.1% of reading\/°C \u0026lt; 18°C \u0026gt; 28°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic error\u003c\/td\u003e\n\u003ctd\u003eRefers to the reference temperature range and is guaranteed for 1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003eRefers to the operating temperature range and is guaranteed for 1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClimatic class\u003c\/td\u003e\n\u003ctd\u003eC1 (IEC 654-1), -5°C to +45°C (23° to +115° F), 5% to 95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective type\u003c\/td\u003e\n\u003ctd\u003eIP56 for case, IP40 for battery door according to EN60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eProtection by double and\/or reinforced insulation. max. 50 V to earth. IEC61010-1: Pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC (emission immunity)\u003c\/td\u003e\n\u003ctd\u003eIEC61326-1: Portable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality system\u003c\/td\u003e\n\u003ctd\u003eDeveloped, designed and manufactured according to DIN ISO 9001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal voltage\u003c\/td\u003e\n\u003ctd\u003eV ext, max = 24 V (DC, AC \u0026lt; 400 Hz), measurement inhibited for higher values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eV ext rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 120 dB (162⁄3, 50, 60, 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd\u003eTypical 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. overload\u003c\/td\u003e\n\u003ctd\u003e250 V rms (pertains to misuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary power\u003c\/td\u003e\n\u003ctd\u003e6 x 1.5 V Alkaline (type AA LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life span\u003c\/td\u003e\n\u003ctd\u003eTypical \u0026gt; 3,000 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.1 kg (2.43 lb) including batteries\u003cbr\u003e7.6 kg (16.8 lb) incl. accessories and batteries in carrying case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eRA 3-Pole Ground Resistance Measurement (IEC 1557-5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e3-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(2% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(5% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Current\/Voltage Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe resistance (R\u003csub\u003eS\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary earth electrode resistance (R\u003csub\u003eH\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional error from R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eH\u003c\/sub\u003e[kΩ]•••R\u003csub\u003eS\u003c\/sub\u003e[kΩ]\/R\u003csub\u003eA\u003c\/sub\u003e[Ω]•••0.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold\"\u003eMonitoring of R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith error indicator.\u003cbr\u003eAutomatic range selection.\u003cbr\u003eMeasurement is not performed if the current through the current clamp is too low.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-Pole Ground Resistance Measurement (IEC 1557-5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(2% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(5% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Current\/Voltage Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe resistance (R\u003csub\u003eS +\u003cspan\u003e \u003c\/span\u003e\u003c\/sub\u003eR\u003csub\u003eES\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary earth electrode resistance (R\u003csub\u003eH\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional error from R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eH\u003c\/sub\u003e[kΩ]•••R\u003csub\u003eS\u003c\/sub\u003e[kΩ]\/R\u003csub\u003eA\u003c\/sub\u003e[Ω]•••0.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold\"\u003eMonitoring of R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith error indicator.\u003cbr\u003eAutomatic range selection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eRA 3-Pole Selective Ground Resistance Measurement with Current Clamp (R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith Clamp )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e3-pole with clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(7% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(10% rdg + 5 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Current\/Voltage Measurement (with External Current Clamp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe resistance (R\u003csub\u003eS\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary earth electrode resistance (R\u003csub\u003eH\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold\"\u003eMonitoring of R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith error indicator.\u003cbr\u003eAutomatic range selection.\u003cbr\u003eMeasurement is not performed if the current through the current clamp is too low.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eRA 4-Pole Selective Ground Resistance Measurement with Current Clamp (R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith Clamp )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole with clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(7% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(10% rdg + 5 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Current\/Voltage Measurement (with External Current Clamp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128\u003cbr\u003e Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe resistance (R\u003csub\u003eS\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary earth electrode resistance (R\u003csub\u003eH\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold\"\u003eMonitoring of R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith error indicator.\u003cbr\u003eAutomatic range selection.\u003cbr\u003eMeasurement is not performed if the current through the current clamp is too low.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eStakeless Ground Loop Measurement (2 Clamps )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole 2 clamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(7% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(10% rdg + 5 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Stakeless Measurement of Resistance in Closed Loops Using Two Current Transformers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eNoise current (I\u003csub\u003eEXT\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax. I\u003csub\u003eEXT\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 10 A (AC) (R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e\u0026lt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eMax. I\u003csub\u003eEXT\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 2 A (AC) (R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold\"\u003eAutomatic range selection.\u003cbr\u003eThe information regarding stakeless ground loop measurements is only valid when used in conjunction with the recommended current clamps at the minimum distance specified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434187665493,"sku":"Fluke 1623-2","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/6_22932f3c-bf9f-40eb-92fe-becc79f3975a.jpg?v=1592218782"},{"product_id":"fluke-1625-2-advanced-geo-earth-ground-tester","title":"Fluke 1625-2 Advanced Geo Earth Ground Tester","description":"\u003ch2\u003eProduct overview: Fluke 1625-2 GEO Earth Ground Tester Kit\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003ch3\u003eThe Most Complete Stakeless Earth Ground Tester\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 1630-2 FC Stakeless Earth Ground Clamp is the kind of high-quality, rugged tool you expect from Fluke. Heavy-duty clamp jaw stays in alignment and in calibration even in every day, on-the-job industrial environments. Test the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not permit driving auxiliary test stakes. Stay on line—identify ground loop resistance without the need to disconnect then reconnect the earth electrode from the system.\u003c\/p\u003e\n\u003ch3\u003eStakeless earth ground measurement testing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eYou can also perform earth ground tests in places you’ve not considered before: inside buildings, power pylons, or anywhere you don’t have access to soil\u003c\/li\u003e\n\u003cli\u003eThe Fluke 1625-2 earth ground tester can measure earth ground loop resistances using only clamps\u003c\/li\u003e\n\u003cli\u003eWith this test method, two clamps are placed around the earth ground rod and each are connected to the tester\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThe Fluke 1625-2 improves your earth ground testing process with:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic Frequency Control (AFC) - identifies existing interference and chooses a measurement frequency to minimize its effect, providing more accurate earth ground value\u003c\/li\u003e\n\u003cli\u003eR* measurement - calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to earth ground would see\u003c\/li\u003e\n\u003cli\u003eAdjustable limits - for quicker testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThe Fluke 1625-2 gives you versatility in earth ground testing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3- and 4-pole fall-of-potential, earth resistance loop testing\u003c\/li\u003e\n\u003cli\u003e4-pole soil resistivity testing\u003c\/li\u003e\n\u003cli\u003eSelective earth ground rod testing using 1 clamp\u003c\/li\u003e\n\u003cli\u003eStakeless earth ground rod testing using 2 clamps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThe Fluke 1625-2 offers you simpler, faster earth ground tests than ever before\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe 1625-2 offers internal memory storage up to 1500 records\u003c\/li\u003e\n\u003cli\u003eAccessible via USB port for rapid data transfer and viewing of results\u003c\/li\u003e\n\u003cli\u003eThis earth ground tester also gives you world-class accessories that take the tedium out of earth ground testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdditional tool features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHeavy duty stakes can be hammered into dry, hard soil.\u003c\/li\u003e\n\u003cli\u003eAnd new color-coded wires make setup simple and help eliminate mistakes and speed up setup and tear down time as much as 50%\u003c\/li\u003e\n\u003cli\u003eIP56 rated for outdoor use\u003c\/li\u003e\n\u003cli\u003eRugged carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 1625-2 GEO Earth Ground Tester Kit\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eInternal memory storage up to 1500 records accessible via USB port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring function\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eInterference voltage and frequency, earthing resistance 3- and 4-pole with\/without clip-on current transformer, resistance 2-pole with AC, 2- and 4-pole with DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e4 digit (2999 Digit) - 7 segment liquid crystal display, with improved visibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eCentral rotary switch and function keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eTemperature Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-10°C to 50°C (14°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-30°C to 60°C (-22°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±0.1% of reading\/°C \u0026lt; 18°C \u0026gt; 28°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of protection\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eIP56 for case, IP40 for battery door according to EN60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eMax voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWarning – socket \"clamp\" to socket E, ES, S or H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eSockets E, ES, S or H to each other in any combination, max. U\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V (pertains to misuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eProtection by double and\/or reinforced insulation. Max. 50 V to earth per IEC61010-1. Pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality standard\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eDeveloped, designed and manufactured to comply with DIN ISO 9001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal field influence\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eComplies with DIN 43780 (8\/76)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary power\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e6 x 1.5 V alkaline (IEC LR6 or type AA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eBattery life span\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWith IEC LR6\/type AA: typ. 3,000 measurements (R\u003csub\u003eE\u003c\/sub\u003e+R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e≤ 1 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eWith IEC LR6\/type AA: typ. 6,000 measurements (R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt; 10 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e≤ 1.1 kg (2.43 lb) without accessories 7.6 kg (16.8 lb) incl. accessories and batteries in carrying case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase material\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003ePolyester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eMeasurement of Interference Voltage DC + AC (U\u003csub\u003eST\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring limits of error: method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eFull wave rectification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 V to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.0 V to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eDC\/AC 45 Hz to 400 Hz sine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring sequence\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eApprox. 4 measurements\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal resistance\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eApprox. 1.5 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eMeasurement of Interference Frequency (F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring limits of error: method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eMeasurement of oscillation period of the interference voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e6.0 Hz to 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e16.0 Hz to 299.9 Hz to 999 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 Hz to 1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 V to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(1% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eEarthing Resistance (RE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eCurrent and voltage measurement with probe as IEC61557-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e20\/48 V, AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e250 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e94, 105, 111, 128 Hz selected manually or automatic. (AFC) 55 Hz in function R\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise rejection\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e120 dB (16 2\/3 , 50 , 60, 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eElectrical Measurement Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd\u003eIntrinsic Error or Influence Quantity\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eReference Conditions or Specified Operating Range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eDesignation Code\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRequirements or Test in Accordance with the Relevant Parts of IEC 1557\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eType of Test\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic error\u003c\/td\u003e\n\u003ctd\u003eReference conditions\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003ePart 5, 6.1\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition\u003c\/td\u003e\n\u003ctd\u003eReference position ±90°\u003c\/td\u003e\n\u003ctd\u003eE1\u003c\/td\u003e\n\u003ctd\u003ePart 1, 4.2\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003eAt the limits stated by the manufacturer\u003c\/td\u003e\n\u003ctd\u003eE2\u003c\/td\u003e\n\u003ctd\u003ePart 1, 4.2, 4.3\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0°C and 35°C\u003c\/td\u003e\n\u003ctd\u003eE3\u003c\/td\u003e\n\u003ctd\u003ePart 1, 4.2\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries interference voltage\u003c\/td\u003e\n\u003ctd\u003eSee 4.2 and 4.3\u003c\/td\u003e\n\u003ctd\u003eE4\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.2, 4.3\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance of the probes and auxiliary earth electrodes\u003c\/td\u003e\n\u003ctd\u003e0 to 100 x R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ebut ≤ 50 kΩ\u003c\/td\u003e\n\u003ctd\u003eE5\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem frequency\u003c\/td\u003e\n\u003ctd\u003e99% to 101% of the nominal frequency\u003c\/td\u003e\n\u003ctd\u003eE7\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem voltage\u003c\/td\u003e\n\u003ctd\u003e85% to 110% of the nominal voltage\u003c\/td\u003e\n\u003ctd\u003eE8\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eB = ±(|A| + 1,15 √E\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e1\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e2\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e3\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e4\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e5\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e6\u003cspan\u003e \u003c\/span\u003e\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"4\"\u003eB[%] = ± B\/fiducial value x 100%\u003cbr\u003e\u003cbr\u003eA = intrinsic error\u003cbr\u003eEn = variations\u003cbr\u003eR = routine test\u003cbr\u003eT = type test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.300 kΩ to 2.999 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 kΩ to 299.9 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e±(2% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eTypical 8 seconds with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequencies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional error because of probe-and auxiliary earth electrode resistance\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eR\u003csub\u003eH\u003c\/sub\u003e(R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ 2000 Ω)\/R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ex 1.25 x 10\u003csup\u003e-6\u003c\/sup\u003e% + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring error of R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eTyp. 10% of R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. probe resistance\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e≤ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. auxiliary earth electrode resistance\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e≤ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"5\"\u003eAutomatic check if error is kept within the limits required by IEC61557-5.\u003cbr\u003eIf after a measurement of probe-, auxiliary earth electrode- and earthing resistance, a measurement error of higher than 30% is assumed because of the influencing conditions, the display shows a warning symbol and a notice that RS or RH are too high.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eAutomatic Switchover of Measuring Resolution in Dependence to Auxiliary Earth Electrode Resistance R\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRH with U\u003csub\u003emeas\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 48 V\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026lt; 300 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 6 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 60 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 600 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRH with U\u003csub\u003emeas\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 20 V\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026lt; 250 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 2.5 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 25 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e100 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eSelective Measurement of the Earthing Resistance (R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eClamp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eCurrent and voltage measurement with probe as per EN61557-5 and current measurement in the individual branch with additional current transformer (patent applied for).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e20\/48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e250 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e94, 105, 111, 128 Hz selected manually or automatically (AFC), 55 Hz (R\u003csup\u003e1\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise rejection\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e120 dB (162\/3, 50, 60, 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. overload\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eMax. U\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V (measurement will not be started)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.300 kΩ to 2.999 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e±(7% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e±(10% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional error because of probe- and auxiliary earth typ. electrode resistance\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eR\u003csub\u003eH\u003c\/sub\u003e(R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ 2000 Ω)\/R\u003csub\u003eETOTAL\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ex 1.25 x 10\u003csup\u003e-6\u003c\/sup\u003e% + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring error of R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eTyp. of 10% of R\u003csub\u003eETOTAL\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eTyp. 8 sec. with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequencies.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMinimal current in single branch to be measured\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e0.5 mA\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWith transformer (1000:1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.1 mA\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWith transformer (200:1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. interference current through transformer\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e3 A\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWith transformer (1000:1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"5\"\u003e1. With recommended current clamps\/transformers.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eResistance Measurement (R~)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eCurrent and voltage measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e20 V AC, square pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026gt; 250 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e94, 105, 111, 128 Hz selected manually or automatically (AFC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e300 Ω to 2999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 kΩ to 299.9 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(2% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eTypical 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. interference voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e24 V, with higher voltages measurement will not be started\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003emax. = 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eResistance Measurement (R DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eCurrent- voltage measurement as per IEC61557-4 possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e20 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e250 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormation of measured value\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eWith 4-pole measurement wires on H, S, ES can be extended without additional error.\u003cbr\u003eResistances \u0026gt; 1 Ω in wire E can cause additional error of 5m Ω\/Ω.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e300 Ω to 2999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.0 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 kΩ to 299.9 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(2% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring sequence\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eApprox. 2 measurements\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eTypical 4 second including reversal of polarity (2-pole or 4-pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum interference voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e≤ 3 V AC or DC, with higher voltages measurement will not be started\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum inductivity\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2 Henry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eCompensation of Lead Resistance (R\u003csub\u003eK\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"5\"\u003eCompensation of lead resistance (R\u003csub\u003eK\u003c\/sub\u003e) can be switched on in functions R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e3-pole, R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole (clamp), R AC, and R DC 2-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormation of measured value\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eR\u003csub\u003edisplay\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= R\u003csub\u003emeasured\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e- R\u003csub\u003ecompensated\u003c\/sub\u003e\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"5\"\u003e2. Value of setpoint entry RK = 0.000 Ω, variable from 0.000 to 29.99 Ω by means of measuring adjustment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eStakeless Ground Loop Measurement (Two Clamp Stakeless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eRA 4-pole (two clamp Stakeless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.02 Ω to 199.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(7% rdg + 3 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(10% rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eVm = 48 V AC (primary)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eNoise current (IEXT)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eMax. IEXT = 10 A (AC) (RA \u0026lt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eMax. IEXT = 2 A (AC) (RA \u0026gt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"5\"\u003eMeasuring principle: Stakeless measurement of resistance in closed loops using two current transformers.\u003cbr\u003eAutomatic range selection.\u003cbr\u003eThe information regarding stakeless ground loop measurements is only valid when used in conjunction with the recommended current clamps at the minimum distance specified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434187698261,"sku":"Fluke 1625-2","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/1ac-II-voltage-tester_1.jpg?v=1597674392"},{"product_id":"fluke-1623-2-kit-basic-geo-earth-ground-tester-kit","title":"Fluke 1623-2 Kit Basic Geo Earth Ground Tester, Kit","description":"\u003ch2\u003eProduct overview: Fluke 1623-2 GEO Earth Ground Tester Kit\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003eThe Fluke 1623-2 GEO Earth Ground Tester offers data storage and download capabilities via USB port. World class accessories will simplify and speed up testing time.\u003c\/p\u003e\n\u003cp\u003eFluke 1623-2 GEO Earth Ground Tester summary\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3- and 4-pole Fall-of-Potential, earth resistance loop testing\u003c\/li\u003e\n\u003cli\u003e4-pole Soil Resistivity testing\u003c\/li\u003e\n\u003cli\u003eSelective earth ground rod testing using 1 clamp\u003c\/li\u003e\n\u003cli\u003eStakeless earth ground rod testing using 2 clamps\u003c\/li\u003e\n\u003cli\u003eIP56 rated for outdoor use\u003c\/li\u003e\n\u003cli\u003eRugged carrying case\u003c\/li\u003e\n\u003cli\u003eUSB data storage and transfer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 1623-2 GEO Earth Ground Tester Kit\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay: 1999 digit LCD\u003c\/td\u003e\n\u003ctd\u003eDisplay with special symbols, digit height 25 mm, fluorescent backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser interface\u003c\/td\u003e\n\u003ctd\u003eInstant measurement through TURN and START one button concept. The only operating elements are rotary switch and START button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRobust, water and dust resistant\u003c\/td\u003e\n\u003ctd\u003eInstrument is designed for tough environmental conditions (rubber protective cover, IP56)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eInternal memory storage up to 1500 records accessible via USB port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eTemperature Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to 50°C (14°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to 60°C (-22°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd\u003e±0.1% of reading\/°C \u0026lt; 18°C \u0026gt; 28°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic error\u003c\/td\u003e\n\u003ctd\u003eRefers to the reference temperature range and is guaranteed for 1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003eRefers to the operating temperature range and is guaranteed for 1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClimatic class\u003c\/td\u003e\n\u003ctd\u003eC1 (IEC 654-1), -5°C to +45°C (23° to +115° F), 5% to 95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective type\u003c\/td\u003e\n\u003ctd\u003eIP56 for case, IP40 for battery door according to EN60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eProtection by double and\/or reinforced insulation. max. 50 V to earth. IEC61010-1: Pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC (emission immunity)\u003c\/td\u003e\n\u003ctd\u003eIEC61326-1: Portable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality system\u003c\/td\u003e\n\u003ctd\u003eDeveloped, designed and manufactured according to DIN ISO 9001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal voltage\u003c\/td\u003e\n\u003ctd\u003eV ext, max = 24 V (DC, AC \u0026lt; 400 Hz), measurement inhibited for higher values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eV ext rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 120 dB (162⁄3, 50, 60, 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd\u003eTypical 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. overload\u003c\/td\u003e\n\u003ctd\u003e250 V rms (pertains to misuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary power\u003c\/td\u003e\n\u003ctd\u003e6 x 1.5 V Alkaline (type AA LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life span\u003c\/td\u003e\n\u003ctd\u003eTypical \u0026gt; 3,000 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.1 kg (2.43 lb) including batteries\u003cbr\u003e7.6 kg (16.8 lb) incl. accessories and batteries in carrying case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eRA 3-Pole Ground Resistance Measurement (IEC 1557-5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e3-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(2% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(5% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Current\/Voltage Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe resistance (R\u003csub\u003eS\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary earth electrode resistance (R\u003csub\u003eH\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional error from R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eH\u003c\/sub\u003e[kΩ]•••R\u003csub\u003eS\u003c\/sub\u003e[kΩ]\/R\u003csub\u003eA\u003c\/sub\u003e[Ω]•••0.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold\"\u003eMonitoring of R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith error indicator.\u003cbr\u003eAutomatic range selection.\u003cbr\u003eMeasurement is not performed if the current through the current clamp is too low.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-Pole Ground Resistance Measurement (IEC 1557-5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(2% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(5% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Current\/Voltage Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe resistance (R\u003csub\u003eS +\u003cspan\u003e \u003c\/span\u003e\u003c\/sub\u003eR\u003csub\u003eES\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary earth electrode resistance (R\u003csub\u003eH\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional error from R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eH\u003c\/sub\u003e[kΩ]•••R\u003csub\u003eS\u003c\/sub\u003e[kΩ]\/R\u003csub\u003eA\u003c\/sub\u003e[Ω]•••0.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold\"\u003eMonitoring of R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith error indicator.\u003cbr\u003eAutomatic range selection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eRA 3-Pole Selective Ground Resistance Measurement with Current Clamp (R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith Clamp )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e3-pole with clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(7% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(10% rdg + 5 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Current\/Voltage Measurement (with External Current Clamp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe resistance (R\u003csub\u003eS\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary earth electrode resistance (R\u003csub\u003eH\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold\"\u003eMonitoring of R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith error indicator.\u003cbr\u003eAutomatic range selection.\u003cbr\u003eMeasurement is not performed if the current through the current clamp is too low.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eRA 4-Pole Selective Ground Resistance Measurement with Current Clamp (R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith Clamp )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole with clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(7% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(10% rdg + 5 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Current\/Voltage Measurement (with External Current Clamp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe resistance (R\u003csub\u003eS\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary earth electrode resistance (R\u003csub\u003eH\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold\"\u003eMonitoring of R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith error indicator.\u003cbr\u003eAutomatic range selection.\u003cbr\u003eMeasurement is not performed if the current through the current clamp is too low.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eStakeless Ground Loop Measurement (2 Clamps )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole 2 clamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(7% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(10% rdg + 5 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Stakeless Measurement of Resistance in Closed Loops Using Two Current Transformers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eNoise current (I\u003csub\u003eEXT\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax. I\u003csub\u003eEXT\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 10 A (AC) (R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e\u0026lt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eMax. I\u003csub\u003eEXT\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 2 A (AC) (R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold\"\u003eAutomatic range selection.\u003cbr\u003eThe information regarding stake-less ground loop measurements is only valid when used in conjunction with the recommended current clamps at the minimum distance specified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"features-title\"\u003e\n\u003cbr\u003eKey features\u003c\/h2\u003e\n\u003cdiv aria-expanded=\"true\" data-readmore=\"\" id=\"keyfeature_content\"\u003e\n\u003cp\u003e\u003cstrong\u003eStake-less Testing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1623-2 earth ground tester is able to measure earth ground loop resistances using only clamps. With this test method, two clamps are placed around the earth ground rod and each are connected to the tester. No earth ground stakes are used at all. A known, fixed voltage is induced by one clamp and the current is measured using the second clamp. Then the tester automatically determines the resistance of the earth ground rod. This test method only works if a bonded earth ground system exists for the building or structure under test, but most are. If there is only one path to ground, like at many residential applications, the Stake-less method will not provide an acceptable value and the Fall-of-Potential test method must be used.\u003c\/p\u003e\n\u003cp\u003eWith Stake-less testing, the earth ground rod does not need to be disconnected - leaving the bonded earth ground system intact during test. Gone are the days of spending time placing and connecting stakes for each earth ground rod on your system - a major time saver. You can also perform earth ground tests in places you’ve not considered before: inside buildings, power pylons, or anywhere you don’t have access to soil.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Most Complete Tester\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1623-2 is a unique earth ground tester that can perform all four types of earth ground measurement.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3- and 4-Pole Fall-of-Potential (using stakes)\u003c\/li\u003e\n\u003cli\u003e4-Pole Soil Resistivity Testing (using stakes)\u003c\/li\u003e\n\u003cli\u003eSelective Testing (using 1 clamp and stakes)\u003c\/li\u003e\n\u003cli\u003eStake-less Testing (using 2 clamps only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434187731029,"sku":"Fluke 1623-2 Kit","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/6a.jpg?v=1592218913"},{"product_id":"fluke-1625-2-kit-advanced-geo-earth-ground-tester-kit","title":"Fluke 1625-2 Kit Advanced Geo Earth Ground Tester, Kit","description":"\u003ch2\u003eProduct overview: Fluke 1625-2 GEO Earth Ground Tester Kit\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003ch3\u003eThe Most Complete Stakeless Earth Ground Tester\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 1630-2 FC Stakeless Earth Ground Clamp is the kind of high-quality, rugged tool you expect from Fluke. Heavy-duty clamp jaw stays in alignment and in calibration even in every day, on-the-job industrial environments. Test the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not permit driving auxiliary test stakes. Stay on line—identify ground loop resistance without the need to disconnect then reconnect the earth electrode from the system.\u003c\/p\u003e\n\u003ch3\u003eStakeless earth ground measurement testing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eYou can also perform earth ground tests in places you’ve not considered before: inside buildings, power pylons, or anywhere you don’t have access to soil\u003c\/li\u003e\n\u003cli\u003eThe Fluke 1625-2 earth ground tester can measure earth ground loop resistances using only clamps\u003c\/li\u003e\n\u003cli\u003eWith this test method, two clamps are placed around the earth ground rod and each are connected to the tester\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThe Fluke 1625-2 improves your earth ground testing process with:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic Frequency Control (AFC) - identifies existing interference and chooses a measurement frequency to minimize its effect, providing more accurate earth ground value\u003c\/li\u003e\n\u003cli\u003eR* measurement - calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to earth ground would see\u003c\/li\u003e\n\u003cli\u003eAdjustable limits - for quicker testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThe Fluke 1625-2 gives you versatility in earth ground testing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3- and 4-pole fall-of-potential, earth resistance loop testing\u003c\/li\u003e\n\u003cli\u003e4-pole soil resistivity testing\u003c\/li\u003e\n\u003cli\u003eSelective earth ground rod testing using 1 clamp\u003c\/li\u003e\n\u003cli\u003eStakeless earth ground rod testing using 2 clamps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThe Fluke 1625-2 offers you simpler, faster earth ground tests than ever before\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe 1625-2 offers internal memory storage up to 1500 records\u003c\/li\u003e\n\u003cli\u003eAccessible via USB port for rapid data transfer and viewing of results\u003c\/li\u003e\n\u003cli\u003eThis earth ground tester also gives you world-class accessories that take the tedium out of earth ground testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdditional tool features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHeavy duty stakes can be hammered into dry, hard soil.\u003c\/li\u003e\n\u003cli\u003eAnd new color-coded wires make setup simple and help eliminate mistakes and speed up setup and tear down time as much as 50%\u003c\/li\u003e\n\u003cli\u003eIP56 rated for outdoor use\u003c\/li\u003e\n\u003cli\u003eRugged carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 1625-2 GEO Earth Ground Tester Kit\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eInternal memory storage up to 1500 records accessible via USB port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring function\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eInterference voltage and frequency, earthing resistance 3- and 4-pole with\/without clip-on current transformer, resistance 2-pole with AC, 2- and 4-pole with DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e4 digit (2999 Digit) - 7 segment liquid crystal display, with improved visibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eCentral rotary switch and function keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eTemperature Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-10°C to 50°C (14°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-30°C to 60°C (-22°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±0.1% of reading\/°C \u0026lt; 18°C \u0026gt; 28°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of protection\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eIP56 for case, IP40 for battery door according to EN60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eMax voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWarning – socket \"clamp\" to socket E, ES, S or H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eSockets E, ES, S or H to each other in any combination, max. U\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V (pertains to misuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eProtection by double and\/or reinforced insulation. Max. 50 V to earth per IEC61010-1. Pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality standard\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eDeveloped, designed and manufactured to comply with DIN ISO 9001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal field influence\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eComplies with DIN 43780 (8\/76)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary power\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e6 x 1.5 V alkaline (IEC LR6 or type AA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eBattery life span\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWith IEC LR6\/type AA: typ. 3,000 measurements (R\u003csub\u003eE\u003c\/sub\u003e+R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e≤ 1 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eWith IEC LR6\/type AA: typ. 6,000 measurements (R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt; 10 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e≤ 1.1 kg (2.43 lb) without accessories 7.6 kg (16.8 lb) incl. accessories and batteries in carrying case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase material\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003ePolyester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eMeasurement of Interference Voltage DC + AC (U\u003csub\u003eST\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring limits of error: method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eFull wave rectification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 V to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.0 V to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eDC\/AC 45 Hz to 400 Hz sine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring sequence\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eApprox. 4 measurements\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal resistance\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eApprox. 1.5 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eMeasurement of Interference Frequency (F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring limits of error: method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eMeasurement of oscillation period of the interference voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e6.0 Hz to 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e16.0 Hz to 299.9 Hz to 999 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 Hz to 1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 V to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(1% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eEarthing Resistance (RE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eCurrent and voltage measurement with probe as IEC61557-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e20\/48 V, AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e250 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e94, 105, 111, 128 Hz selected manually or automatic. (AFC) 55 Hz in function R\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise rejection\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e120 dB (16 2\/3 , 50 , 60, 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eElectrical Measurement Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd\u003eIntrinsic Error or Influence Quantity\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eReference Conditions or Specified Operating Range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eDesignation Code\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRequirements or Test in Accordance with the Relevant Parts of IEC 1557\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eType of Test\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic error\u003c\/td\u003e\n\u003ctd\u003eReference conditions\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003ePart 5, 6.1\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition\u003c\/td\u003e\n\u003ctd\u003eReference position ±90°\u003c\/td\u003e\n\u003ctd\u003eE1\u003c\/td\u003e\n\u003ctd\u003ePart 1, 4.2\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003eAt the limits stated by the manufacturer\u003c\/td\u003e\n\u003ctd\u003eE2\u003c\/td\u003e\n\u003ctd\u003ePart 1, 4.2, 4.3\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0°C and 35°C\u003c\/td\u003e\n\u003ctd\u003eE3\u003c\/td\u003e\n\u003ctd\u003ePart 1, 4.2\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries interference voltage\u003c\/td\u003e\n\u003ctd\u003eSee 4.2 and 4.3\u003c\/td\u003e\n\u003ctd\u003eE4\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.2, 4.3\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance of the probes and auxiliary earth electrodes\u003c\/td\u003e\n\u003ctd\u003e0 to 100 x R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ebut ≤ 50 kΩ\u003c\/td\u003e\n\u003ctd\u003eE5\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem frequency\u003c\/td\u003e\n\u003ctd\u003e99% to 101% of the nominal frequency\u003c\/td\u003e\n\u003ctd\u003eE7\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem voltage\u003c\/td\u003e\n\u003ctd\u003e85% to 110% of the nominal voltage\u003c\/td\u003e\n\u003ctd\u003eE8\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eB = ±(|A| + 1,15 √E\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e1\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e2\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e3\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e4\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e5\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e6\u003cspan\u003e \u003c\/span\u003e\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"4\"\u003eB[%] = ± B\/fiducial value x 100%\u003cbr\u003e\u003cbr\u003eA = intrinsic error\u003cbr\u003eEn = variations\u003cbr\u003eR = routine test\u003cbr\u003eT = type test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.300 kΩ to 2.999 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 kΩ to 299.9 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e±(2% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eTypical 8 seconds with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequencies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional error because of probe-and auxiliary earth electrode resistance\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eR\u003csub\u003eH\u003c\/sub\u003e(R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ 2000 Ω)\/R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ex 1.25 x 10\u003csup\u003e-6\u003c\/sup\u003e% + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring error of R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eTyp. 10% of R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. probe resistance\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e≤ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. auxiliary earth electrode resistance\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e≤ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"5\"\u003eAutomatic check if error is kept within the limits required by IEC61557-5.\u003cbr\u003eIf after a measurement of probe-, auxiliary earth electrode- and earthing resistance, a measurement error of higher than 30% is assumed because of the influencing conditions, the display shows a warning symbol and a notice that RS or RH are too high.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eAutomatic Switchover of Measuring Resolution in Dependence to Auxiliary Earth Electrode Resistance R\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRH with U\u003csub\u003emeas\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 48 V\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026lt; 300 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 6 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 60 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 600 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRH with U\u003csub\u003emeas\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 20 V\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026lt; 250 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 2.5 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 25 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e100 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eSelective Measurement of the Earthing Resistance (R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eClamp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eCurrent and voltage measurement with probe as per EN61557-5 and current measurement in the individual branch with additional current transformer (patent applied for).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e20\/48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e250 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e94, 105, 111, 128 Hz selected manually or automatically (AFC), 55 Hz (R\u003csup\u003e1\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise rejection\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e120 dB (162\/3, 50, 60, 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. overload\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eMax. U\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V (measurement will not be started)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.300 kΩ to 2.999 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e±(7% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e±(10% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional error because of probe- and auxiliary earth typ. electrode resistance\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eR\u003csub\u003eH\u003c\/sub\u003e(R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ 2000 Ω)\/R\u003csub\u003eETOTAL\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ex 1.25 x 10\u003csup\u003e-6\u003c\/sup\u003e% + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring error of R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eTyp. of 10% of R\u003csub\u003eETOTAL\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eTyp. 8 sec. with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequencies.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMinimal current in single branch to be measured\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e0.5 mA\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWith transformer (1000:1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.1 mA\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWith transformer (200:1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. interference current through transformer\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e3 A\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWith transformer (1000:1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"5\"\u003e1. With recommended current clamps\/transformers.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eResistance Measurement (R~)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eCurrent and voltage measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e20 V AC, square pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026gt; 250 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e94, 105, 111, 128 Hz selected manually or automatically (AFC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e300 Ω to 2999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 kΩ to 299.9 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(2% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eTypical 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. interference voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e24 V, with higher voltages measurement will not be started\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003emax. = 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eResistance Measurement (R DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eCurrent- voltage measurement as per IEC61557-4 possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e20 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e250 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormation of measured value\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eWith 4-pole measurement wires on H, S, ES can be extended without additional error.\u003cbr\u003eResistances \u0026gt; 1 Ω in wire E can cause additional error of 5m Ω\/Ω.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e300 Ω to 2999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.0 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 kΩ to 299.9 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(2% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring sequence\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eApprox. 2 measurements\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eTypical 4 second including reversal of polarity (2-pole or 4-pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum interference voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e≤ 3 V AC or DC, with higher voltages measurement will not be started\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum inductivity\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2 Henry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eCompensation of Lead Resistance (R\u003csub\u003eK\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"5\"\u003eCompensation of lead resistance (R\u003csub\u003eK\u003c\/sub\u003e) can be switched on in functions R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e3-pole, R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole (clamp), R AC, and R DC 2-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormation of measured value\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eR\u003csub\u003edisplay\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= R\u003csub\u003emeasured\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e- R\u003csub\u003ecompensated\u003c\/sub\u003e\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"5\"\u003e2. Value of setpoint entry RK = 0.000 Ω, variable from 0.000 to 29.99 Ω by means of measuring adjustment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eStakeless Ground Loop Measurement (Two Clamp Stakeless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eRA 4-pole (two clamp Stakeless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.02 Ω to 199.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(7% rdg + 3 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(10% rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eVm = 48 V AC (primary)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eNoise current (IEXT)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eMax. IEXT = 10 A (AC) (RA \u0026lt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eMax. IEXT = 2 A (AC) (RA \u0026gt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"5\"\u003eMeasuring principle: Stakeless measurement of resistance in closed loops using two current transformers.\u003cbr\u003eAutomatic range selection.\u003cbr\u003eThe information regarding stakeless ground loop measurements is only valid when used in conjunction with the recommended current clamps at the minimum distance specified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434187763797,"sku":"Fluke 1625-2 Kit","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/6q.jpg?v=1592219940"},{"product_id":"fluke-437-ii-power-quality-energy-analyzer","title":"Fluke 437-II Power Quality\u0026 Energy Analyzer","description":"\u003ch2\u003eProduct overview: Fluke 437 Series II 400 Hz Power Quality Monitor and Energy Analyzer\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003eIf you’re dealing with aviation systems measuring key power quality parameters at 400Hz is a must. The Fluke 437-II provides that capability (and measures at 50 and 60Hz too) and is designed for users who need to quickly get to the source of the power quality problem, so they can minimize expensive downtime. The integrated shipboard power measurement system analyzes according to MIL-STD 1399 to automatically give a full evaluation of voltage, current and power according to the standard. This evaluation makes measurement and analysis as easy as can be. The measurement process, and the way the 437-II displays data has been optimized to provide to the most important information as quickly as possible. Multiple parameters are measured simultaneously and are displayed in formats that quickly describe overall power quality health while giving you the detailed information you need to make better maintenance decisions. Data can be quickly accessed as simple digital values, viewed as trend graphs that give you fast insight into changes over time, or viewed as waveforms and phasor diagrams or analyzed. Data can also be organized into tabular format for viewing events where the magnitude, duration and time stamp enable rapid correlation to the problems you are experiencing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLocating, Predicting, Preventing and Troubleshooting Power Quality Issues—\u003c\/strong\u003eUp to 400Hz\u003c\/p\u003e\n\u003cp\u003eHigher power frequencies mean smaller and lighter transformers and motors – a critical factor in avionic and military transport applications where weight is a primary concern. The Fluke 437 Series II Power Quality and Energy Analyzer can show you the cost of energy waste due to poor power quality and is ideal for characterizing power quality, conducting load studies and capturing hard-to-find voltage events over a user-defined period of time. Designed for capturing power quality measurements in avionic and military systems, Fluke 437 Series II is the must-have 400 Hz quality analyzer.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e400 Hz operation according to MIL-STD 1399 for use in avionic and military applications\u003c\/li\u003e\n\u003cli\u003eShipboard power measurement system analyzes according to MIL-STD 1399 to automatically give a full evaluation of voltage, current and power\u003c\/li\u003e\n\u003cli\u003eGet at-a-glance power quality health data in real-time so you can make better maintenance decisions\u003c\/li\u003e\n\u003cli\u003eMeasure all three phases and neutral with the included flexible current probes\u003c\/li\u003e\n\u003cli\u003eQuickly see how much money you’re losing due to energy waste in terms of real dollars\u003c\/li\u003e\n\u003cli\u003eEasily see how motor startups are affecting motor drive performance\u003c\/li\u003e\n\u003cli\u003eHighest safety rating in the industry: 600 V CAT IV\/1000 V CAT III rated for use at the service entrance\u003c\/li\u003e\n\u003cli\u003eFluke Connect® compatible* – view data locally on the instrument, via Fluke Connect mobile app and PowerLog 430-II desktop software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Power Quality Health—\u003c\/strong\u003eAt-a-glance power quality health data in real-time so you have the data you need, when you need it\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg alt=\"Power wave data capture\" class=\" lazyloaded\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/Monitor_320px_x_240px.jpg\" title=\"Power wave data capture\" width=\"320\"\u003e\n\u003cfigcaption\u003ePower wave data capture\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe Fluke 437-II Power Quality Monitor and Energy Analyzer utilizes an integrated Power Quality Health summary that gives you an at-a-glance view of a complete range of power quality issues in real time. With a simple graphical presentation, complete with tolerance limits, you can quickly discover which power quality problems may be present on your electrical system. If you don’t know where to start or what problems might exist, the advanced Power Quality Health summary will simplify the task and serves as a comprehensive starting point for further troubleshooting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePowerWave Data Capture—\u003c\/strong\u003eQuickly identify how motor and generator startups are impacting electrical system performance\u003c\/p\u003e\n\u003cp\u003eWith PowerWave data capture you can capture three-phase high resolution voltage and current waveforms for up to five minutes along with detailed RMS voltage and current values. By analyzing the interaction of these values over time you can correlate the effects of voltage, current and frequency during the critical startup of motors and generators. PowerWave even goes beyond the standard power quality measurements allowing you to record half cycle rms values on 8 channels, frequency and instantaneous power (Vrms1\/2, Arms1\/2, W, Hz and scope waveforms for voltage, amps and watts)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower Inverter Efficiency\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePower inverters take DC current and transform it into AC current, or vice versa. But, what percentage of that power going into the inverter comes out as usable current? The Fluke 437-II Power Monitor and Energy Analyzer has an integrated power inverter efficiency mode that allows users to better understand power inverter performance. Nothing is ever 100% efficient, and a power inverter’s efficiency will vary depending on how much power is being used at the time (with the efficiency generally being greater when more power is being used). Inverters can also lose performance over time and need to be checked. By comparing the input power with the output power, you can determine the system efficiency. With the Power Inverter Efficiency feature you can discover just how good your inverter is at converting your DC power to AC (or visa versa). Poor power efficiency may occur when the inverter is wrongly sized for the load.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAutoTrend—\u003c\/strong\u003eQuickly see the trend\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg alt=\"AutoTrend capability shows changes over time\" class=\" lazyloaded\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/v-a-hz-us.jpg\" title=\"AutoTrend capability shows changes over time\" width=\"320\"\u003e\n\u003cfigcaption\u003eAutoTrend capability shows changes over time\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cp\u003eWith a unique AutoTrend feature you can get fast insight into changes over time. Every displayed reading is automatically and continuously recorded without having to set up threshold levels or having to manually start the process so you can quickly view trends in voltage, current, frequency, power, harmonics or flicker on all three phases plus neutral.\u003c\/p\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cp\u003eThe Fluke 437-II series helps you locate, predict, prevent and troubleshoot Power Quality Issues – 50Hz, 60Hz and 400Hz\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e400 Hz operation for use in avionic and military applications\u003c\/li\u003e\n\u003cli\u003eShipboard power measurement system analyzes according to MIL-STD 1399 to automatically give a full evaluation of voltage, current and power\u003c\/li\u003e\n\u003cli\u003eAdvanced Power Quality Health— At-a-glance power quality health data in real-time so you have the data you need, when you need it\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 437 Series II 400 Hz Power Quality Monitor and Energy Analyzer\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" style=\"width: 488px;\"\u003eProduct Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003e\u003cb\u003eVolt\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e\u003cb\u003eModel\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e\u003cb\u003eMeasurement Range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eVrms (ac+dc)\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e1 V to 1000 V phase to neutral\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.01 V\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.1% of nominal voltage**** \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eVpk\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e1 Vpk to 1400 Vpk\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e1 V\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e5% of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eVoltage Crest Factor (CF)\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e1.0 \u0026gt; 2.8\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.01\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eVfund\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.1% of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 488px;\"\u003eAmps (accuracy excluding clamp accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 115px;\"\u003eAmps (ac+dc)\u003c\/td\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e\u003cb\u003ei430-Flex 1x \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e5 A to 6000 A\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e1 A\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.5% ± 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003ei430-Flex 10x\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.5 A to 600 A\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 A\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.5% ± 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e1mV\/A 1x\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e5 A to 2000 A\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e1A\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.5% ± 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e1mV\/A 10x\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.5 A A to 200 A (ac only)\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 A\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.5% ± 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 115px;\"\u003eApk\u003c\/td\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e\u003cb\u003ei430-Flex \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e8400 Apk \u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e1 Arms\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e1mV\/A\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e5500 Apk\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e1 Arms\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eA Crest Factor (CF)\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e1 to 10\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.01\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 115px;\"\u003eAmps½\u003c\/td\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e\u003cb\u003ei430-Flex 1x \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e5 A to 6000 A \u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e1 A \u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 1% ± 10 counts \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003ei430-Flex 10x\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.5 A to 600 A\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 A \u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 1% ± 10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e1mV\/A 1x  \u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e5 A to 2000 A \u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e1A \u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 1% ± 10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e1mV\/A 10x\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.5 A A to 200 A (ac only)\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 A\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 1% ± 10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 115px;\"\u003eAfund\u003c\/td\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e\u003cb\u003ei430-Flex 1x \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e5 A to 6000 A\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e1 A\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.5% ± 5 counts \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003ei430-Flex 10x \u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.5 A to 600 A\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 A\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.5% ± 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e1mV\/A 1x \u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e5 A to 2000 A\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e1A\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.5% ± 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e1mV\/A 10x \u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.5 A A to 200 A (ac only)\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 A\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.5% ± 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 488px;\"\u003eHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003e\u003cb\u003eFluke 437 @ 50 Hz nominal\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e42.500 Hz to 57.500 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.001 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eFluke 437 @ 60 Hz nominal \u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e51.000 Hz to 69.000 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.001 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eFluke 437 @ 400 Hz nominal\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e340.0 Hz to 460.0 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 488px;\"\u003ePower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 115px;\"\u003eWatts (VA, var)\u003c\/td\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e\u003cb\u003ei430-Flex \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003emax 6000 MW\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 W to 1 MW\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 1% ± 10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e1 mV\/A\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003emax 2000 MW\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 W to 1 MW\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 1% ± 10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003ePower Factor (Cos j\/DPF)\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0 to 1\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.001\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.1% @ nominal load conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 488px;\"\u003eEnergy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003ekWh (kVAh, kvarh)\u003c\/td\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e\u003cb\u003ei430-Flex 10x\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 177.333px;\"\u003eDepends on clamp scaling and V nominal\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 1% ± 10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003eEnergy Loss\u003c\/td\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e\u003cb\u003ei430-Flex 10x\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 177.333px;\"\u003eDepends on clamp scaling and V nominal\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 1% ± 10 counts Excluding line resistance accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 488px;\"\u003eHarmonics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eHarmonic Order (n)\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 302.333px;\"\u003eDC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eInter-Harmonic Order (n)\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 302.333px;\"\u003eOFF, 1 to 50 Grouping: Harmonic and Interharmonic subgroups according to IEC 61000-4-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 115px;\"\u003eVolts %\u003c\/td\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e\u003cb\u003ef\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 % to 100 %\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 %\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.1% ± n x 0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003er\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 % to 100 %\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 %\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.1% ± n x 0.4 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003eAbsolute\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 to 1000 V\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 5% *\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003eTHD\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 % to 100 %\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 %\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 2.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 115px;\"\u003eAmps %\u003c\/td\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e\u003cb\u003ef\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 % to 100 %\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 %\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.1% ± n x 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003er\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 % to 100 %\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 %\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.1% ± n x 0.4 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003eAbsolute\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 to 600 A\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 A\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 5% ± 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003eTHD\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 % to 100 %\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 %\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 2.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 115px;\"\u003eWatts %\u003c\/td\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e\u003cb\u003ef or r \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 % to 100 %\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 %\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± n x 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003eAbsolute\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003eDepends on clamp scaling and V nominal \u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 5% ± n x 2 % ± 10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003eTHD\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 % to 100 %  \u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 %\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003ePhase Angle\u003cb\u003e \u003c\/b\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e-360° to +0°\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e1°\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± n x 1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 488px;\"\u003eFlicker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003ePlt, Pst, Pst (1min) Pinst\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.00 to 20.00\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.01\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 488px;\"\u003eUnbalance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eVolts\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e%\u003c\/b\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 % to 20.0 %\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 %\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eAmps\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e%\u003c\/b\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 % to 20.0 %\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1%\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 488px;\"\u003eMains Signaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eThreshold Levels\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003eThreshold, limits and signaling duration is programmable for two signaling frequencies\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eSignaling Frequency\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e60 Hz to 3000 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eRelative V%\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0 % to 100 %\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.10 %\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.4 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eAbsolute V3s (3 second avg.)\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 V to 1000 V\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 5 % of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 488px;\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003eCase\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003eDesign Rugged, shock proof with integrated protective holster Drip and dust proof IP51 according to IEC60529 when used in tilt stand position Shock and vibration Shock 30 g, vibration: 3 g sinusoid, random 0.03 g 2 \/Hz according to MIL-PRF-28800F Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003eBrightness: 200 cd\/m 2 typ. using power adapter, 90 cd\/m 2 typical using battery power Size: 127 mm x 88 mm (153 mm\/6.0 in diagonal) LCD Resolution: 320 x 240 pixels Contrast and brightness: user-adjustable, temperature compensated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003eMemory\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003e16GB Wi-Fi SD card for standard models or 8GB SD card for \/INTL models (SDHC compliant, FAT32 formatted), up to 32GB optionally. Screen save and multiple data memories for storing data including recordings (dependent on memory size).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003eReal-Time Clock\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003eTime and date stamp for Trend mode, Transient display, System Monitor and event capture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 488px;\"\u003eEnvironmental\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003e0 °C ~ +40 °C; +40 °C ~ +50 °C excl. battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003e-20 °C ~ +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003e+10 °C ~ +30 °C: 95% RH non-condensing\u003cbr\u003e+30 °C ~ +40 °C: 75% RH non-condensing\u003cbr\u003e+40 °C ~ +50 °C: 45% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003eMaximum Operating Altitude\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003eUp to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V\u003cbr\u003eUp to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V\u003cbr\u003eMaximum storage altitude 12 km (40,000 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003eElectro-Magnetic-Compatibility (EMC)\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003eEN 61326 (2005-12) for emission and immunity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003eInterfaces\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003eMini-USB-B, Isolated USB port for PC connectivity SD card slot accessible behind instrument battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003eThree years (parts and labor) on main instrument, one year on accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" style=\"width: 488px;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003e*\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003e ± 5 % if ≥ 1 % of nominal voltage ± 0.05 % of nominal voltage if \u0026lt; 1% of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003e**\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003e 50Hz\/60Hz nominal frequency according to IEC 61000-4-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003e***\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003e 400Hz measurements are not supported for Flicker, Mains Signaling and Monitor Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003e****\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003e For nominal voltage 50 V to 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504304894037,"sku":"Fluke 437-II","price":5359332.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/Fluke437-II_Main.jpg?v=1598947028"},{"product_id":"fluke-3140r-clip-on-current-transformer-2a-400a-fluke-1750","title":"Fluke  3140R Clip-on Current Transformer 2A-400A (Fluke 1750)","description":"\u003cp\u003e3140R 3140R, CURRENT CLAMP, 400 AMP\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul class=\"arrow-lift2\"\u003e\n\u003cli\u003eCT Type – Clamp On\u003c\/li\u003e\n\u003cli\u003eCurrent Range – 2 to 400Amps\u003c\/li\u003e\n\u003cli\u003eAccuracy – 2 percent RDG +\/- 0.04 Amps\u003c\/li\u003e\n\u003cli\u003eFrequency Response – 20 KiloHertz\u003c\/li\u003e\n\u003cli\u003eJaw Opening – 3.2 centimeters (1.25 inches)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504306401365,"sku":"Fluke 3140R","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/11_67a4b6d4-1862-4119-a6bb-806e56d0a782.jpg?v=1594282105"},{"product_id":"fluke-i40s-el-fluke-17xx-i40s-el-clamp-on-current-transformer","title":"Fluke  i40S-EL Fluke-17xx i40s-EL Clamp-on Current Transformer","description":"\u003cp\u003eI40S-EL3X  I40S-EL3X,FLUKE-17XX I40S-EL CLAMP-ON CURRENT TRANSFORMER\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504307646549,"sku":"Fluke i40S-EL","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/F_i40s_el_01a_h_1500x1000_7e06e4cf-2b11-44a1-9dc3-93ed0cfea28a.jpg?v=1624023884"},{"product_id":"fluke-i40s-el-3pk-fluke-17xxx-i40s-el-clamp-on-current-transformer-3-pack","title":"Fluke i40S-EL\/3pk Fluke-17xxx i40s-EL Clamp-on Current Transformer, 3 pack","description":"\u003cp\u003eI40S-EL3X\/3PK  I40S-EL3X\/3PK,FLUKE-17XX I40S-EL CLAMP-ON CURRENT TRANSFORMER, 3 PACK\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504307679317,"sku":"Fluke i40S-EL\/3pk","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/f-i40s-el-3pk_01a_h-1500x1000.jpg?v=1624023917"},{"product_id":"fluke-tps-clamp-10a-1a-clip-on-current-transformer-10a-1a-fluke-1760","title":"Fluke  TPS Clamp 10A\/1A Clip-on Current Transformer 10A\/1A (Fluke 1760)","description":"\u003cp\u003eTPS CLAMP 10A\/1A  TPS CLAMP 10A\/1A,A680501049, CURRENT PROBE 10\/1A AC\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504308138069,"sku":"Fluke TPS Clamp 10A\/1A","price":0.0,"currency_code":"NGN","in_stock":true}]},{"product_id":"fluke-tps-clamp-50a-5a-clip-on-current-transformer-50a-5a-fluke-1760","title":"Fluke  TPS Clamp 50A\/5A Clip-on Current Transformer 50A\/5A (Fluke 1760)","description":"\u003cp\u003eTPS CLAMP 50A\/5A  TPS CLAMP 50A\/5A,A680501048, CURRENT PROBE 50A\/5A AC\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504308170837,"sku":"Fluke TPS Clamp 50A\/5A","price":0.0,"currency_code":"NGN","in_stock":true}]},{"product_id":"fluke-tps-clamp-200a-20a-clip-on-current-transformer-200a-20a-fluke-1760","title":"Fluke  TPS Clamp 200A\/20A Clip-on Current Transformer 200A\/20A (Fluke 1760)","description":"\u003cp\u003eTPS CLAMP 200\/20  TPS CLAMP 200\/20,A680501050, CURRENT PROBE 200\/20A AC\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504308203605,"sku":"Fluke TPS Clamp 200A\/20A","price":0.0,"currency_code":"NGN","in_stock":true}]},{"product_id":"siemens-3rv2411-0ea10-circuit-breaker-size-s00-for-transformer-protection-a-release-0-28-0-4-a-n-release-8-2-a-screw-terminal-standard-switching-capacity","title":"Siemens 3RV2411-0EA10 Circuit breaker size S00 for transformer protection A-release 0.28...0.4 A N-release 8.2 A screw terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 0.28...0.4 A N-release 8.2 A screw terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-0EA10\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-0EA10\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718903410773,"sku":"3RV2411-0EA10","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93050P_5fc4147f-e079-4a96-9c09-21880fbd451d.png?v=1712664444"},{"product_id":"siemens-3rv2411-0ea15-circuit-breaker-size-s00-for-transformer-protection-a-release-0-28-0-4-a-n-release-8-2-a-screw-terminal-standard-switching-capacity-with-transverse-auxiliary-switches-1-no-1-nc","title":"Siemens 3RV2411-0EA15 Circuit breaker size S00 for transformer protection A-release 0.28...0.4 A N-release 8.2 A screw terminal Standard switching capacity with transverse auxiliary switches 1 NO+1 NC","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 0.28...0.4 A N-release 8.2 A screw terminal Standard switching capacity with transverse auxiliary switches 1 NO+1 NC\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-0EA15\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-0EA15\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718903541845,"sku":"3RV2411-0EA15","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93053P_689b1cc1-737e-426d-9a94-0ee07e0102db.png?v=1712664454"},{"product_id":"siemens-3rv2411-0ea20-circuit-breaker-size-s00-for-transformer-protection-a-release-0-28-0-4-a-n-release-8-2-a-spring-type-terminal-standard-switching-capacity","title":"Siemens 3RV2411-0EA20 Circuit breaker size S00 for transformer protection A-release 0.28...0.4 A N-release 8.2 A Spring-type terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 0.28...0.4 A N-release 8.2 A Spring-type terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-0EA20\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-0EA20\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718904000597,"sku":"3RV2411-0EA20","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93056P_a84e42fd-d2eb-458b-819d-d515f6364e25.png?v=1712664485"},{"product_id":"siemens-3rv2411-0fa10-circuit-breaker-size-s00-for-transformer-protection-a-release-0-35-0-5-a-n-release-10-a-screw-terminal-standard-switching-capacity","title":"Siemens 3RV2411-0FA10 Circuit breaker size S00 for transformer protection A-release 0.35...0.5 A N-release 10 A screw terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 0.35...0.5 A N-release 10 A screw terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-0FA10\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-0FA10\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718904098901,"sku":"3RV2411-0FA10","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93050P_30b1ec51-5876-431d-ac2a-fac7be5009b6.png?v=1712664442"},{"product_id":"siemens-3rv2411-0fa20-circuit-breaker-size-s00-for-transformer-protection-a-release-0-35-0-5-a-n-release-10-a-spring-type-terminal-standard-switching-capacity","title":"Siemens 3RV2411-0FA20 Circuit breaker size S00 for transformer protection A-release 0.35...0.5 A N-release 10 A Spring-type terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 0.35...0.5 A N-release 10 A Spring-type terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-0FA20\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-0FA20\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718904197205,"sku":"3RV2411-0FA20","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93056P_4323aa28-0a55-4bd8-a95b-5359b2cf62a3.png?v=1712664484"},{"product_id":"siemens-3rv2411-0ga10-circuit-breaker-size-s00-for-transformer-protection-a-release-0-45-0-63-a-n-release-13-a-screw-terminal-standard-switching-capacity","title":"Siemens 3RV2411-0GA10 Circuit breaker size S00 for transformer protection A-release 0.45...0.63 A N-release 13 A screw terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 0.45...0.63 A N-release 13 A screw terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-0GA10\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-0GA10\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718904229973,"sku":"3RV2411-0GA10","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93050P_e524e441-cf3f-4bb7-8456-57a7ca0ea952.png?v=1712664440"},{"product_id":"siemens-3rv2411-0ga20-circuit-breaker-size-s00-for-transformer-protection-a-release-0-45-0-63-a-n-release-13-a-spring-type-terminal-standard-switching-capacity","title":"Siemens 3RV2411-0GA20 Circuit breaker size S00 for transformer protection A-release 0.45...0.63 A N-release 13 A Spring-type terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 0.45...0.63 A N-release 13 A Spring-type terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-0GA20\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-0GA20\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718904295509,"sku":"3RV2411-0GA20","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93056P_b98f24de-e348-4d08-b453-55ff121cacfb.png?v=1712664482"},{"product_id":"siemens-3rv2411-0ha10-circuit-breaker-size-s00-for-transformer-protection-a-release-0-55-0-8-a-n-release-16-a-screw-terminal-standard-switching-capacity","title":"Siemens 3RV2411-0HA10 Circuit breaker size S00 for transformer protection A-release 0.55...0.8 A N-release 16 A screw terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 0.55...0.8 A N-release 16 A screw terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-0HA10\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-0HA10\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718904328277,"sku":"3RV2411-0HA10","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93050P_7a7990ea-58e5-483e-8d3a-b91346ebacb3.png?v=1712664438"},{"product_id":"siemens-3rv2411-0ha20-circuit-breaker-size-s00-for-transformer-protection-a-release-0-55-0-8-a-n-release-16-a-spring-type-terminal-standard-switching-capacity","title":"Siemens 3RV2411-0HA20 Circuit breaker size S00 for transformer protection A-release 0.55...0.8 A N-release 16 A Spring-type terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 0.55...0.8 A N-release 16 A Spring-type terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-0HA20\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-0HA20\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718904393813,"sku":"3RV2411-0HA20","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93056P_632c63f7-b978-4984-9c29-36ad3863df9e.png?v=1712664480"},{"product_id":"siemens-3rv2411-0ja10-circuit-breaker-size-s00-for-transformer-protection-a-release-0-7-1-a-n-release-21-a-screw-terminal-standard-switching-capacity","title":"Siemens 3RV2411-0JA10 Circuit breaker size S00 for transformer protection A-release 0.7...1 A N-release 21 A screw terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 0.7...1 A N-release 21 A screw terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-0JA10\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-0JA10\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718904524885,"sku":"3RV2411-0JA10","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93050P_636fd692-ec32-4701-a1c4-0947d0b0b13a.png?v=1712664436"},{"product_id":"siemens-3rv2411-0ja15-circuit-breaker-size-s00-for-transformer-protection-a-release-0-7-1-a-n-release-21-a-screw-terminal-standard-switching-capacity-with-transverse-auxiliary-switches-1-no-1-nc","title":"Siemens 3RV2411-0JA15 Circuit breaker size S00 for transformer protection A-release 0.7...1 A N-release 21 A screw terminal Standard switching capacity with transverse auxiliary switches 1 NO+1 NC","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 0.7...1 A N-release 21 A screw terminal Standard switching capacity with transverse auxiliary switches 1 NO+1 NC\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-0JA15\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-0JA15\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718905114709,"sku":"3RV2411-0JA15","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93053P_5f3749ca-38cd-4034-bd6a-fd861b81b315.png?v=1712664453"},{"product_id":"siemens-3rv2411-0ja20-circuit-breaker-size-s00-for-transformer-protection-a-release-0-7-1-a-n-release-21-a-spring-type-terminal-standard-switching-capacity","title":"Siemens 3RV2411-0JA20 Circuit breaker size S00 for transformer protection A-release 0.7...1 A N-release 21 A Spring-type terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 0.7...1 A N-release 21 A Spring-type terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-0JA20\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-0JA20\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718905147477,"sku":"3RV2411-0JA20","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93056P_6762102b-3876-4755-b447-7724d8e1ea22.png?v=1712664479"},{"product_id":"siemens-3rv2411-0ka10-circuit-breaker-size-s00-for-transformer-protection-a-release-0-9-1-25-a-n-release-26-a-screw-terminal-standard-switching-capacity","title":"Siemens 3RV2411-0KA10 Circuit breaker size S00 for transformer protection A-release 0.9...1.25 A N-release 26 A screw terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 0.9...1.25 A N-release 26 A screw terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-0KA10\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-0KA10\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718905180245,"sku":"3RV2411-0KA10","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93050P_10fc3805-d1b8-4731-a5d4-c6e9d6b90b40.png?v=1712664434"},{"product_id":"siemens-3rv2411-0ka20-circuit-breaker-size-s00-for-transformer-protection-a-release-0-9-1-25-a-n-release-26-a-spring-type-terminal-standard-switching-capacity","title":"Siemens 3RV2411-0KA20 Circuit breaker size S00 for transformer protection A-release 0.9...1.25 A N-release 26 A Spring-type terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 0.9...1.25 A N-release 26 A Spring-type terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-0KA20\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-0KA20\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718905245781,"sku":"3RV2411-0KA20","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93056P_d77c231b-8299-4995-9b4c-758534f6a22c.png?v=1712664477"},{"product_id":"siemens-3rv2411-1aa10-circuit-breaker-size-s00-for-transformer-protection-a-release-1-1-1-6-a-n-release-33-a-screw-terminal-standard-switching-capacity","title":"Siemens 3RV2411-1AA10 Circuit breaker size S00 for transformer protection A-release 1.1...1.6 A N-release 33 A screw terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 1.1...1.6 A N-release 33 A screw terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-1AA10\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-1AA10\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718905278549,"sku":"3RV2411-1AA10","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93050P_ba5ca980-e13d-4644-94d4-18c3e48ffbfa.png?v=1712664432"},{"product_id":"siemens-3rv2411-1aa20-circuit-breaker-size-s00-for-transformer-protection-a-release-1-1-1-6-a-n-release-33-a-spring-type-terminal-standard-switching-capacity","title":"Siemens 3RV2411-1AA20 Circuit breaker size S00 for transformer protection A-release 1.1...1.6 A N-release 33 A Spring-type terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 1.1...1.6 A N-release 33 A Spring-type terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-1AA20\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-1AA20\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718906359893,"sku":"3RV2411-1AA20","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93056P_53687af1-5a10-4fe4-815c-1dad3f10d75a.png?v=1712664476"},{"product_id":"siemens-3rv2411-1ba10-circuit-breaker-size-s00-for-transformer-protection-a-release-1-4-2-a-n-release-42-a-screw-terminal-standard-switching-capacity","title":"Siemens 3RV2411-1BA10 Circuit breaker size S00 for transformer protection A-release 1.4...2 A N release 42 A screw terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 1.4...2 A N release 42 A screw terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-1BA10\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-1BA10\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718906392661,"sku":"3RV2411-1BA10","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93050P_02855191-b97e-4bf6-8233-c8c1ce291349.png?v=1712664430"},{"product_id":"siemens-3rv2411-1ba15-circuit-breaker-size-s00-for-transformer-protection-a-release-1-4-2-a-n-release-42-a-screw-terminal-standard-switching-capacity-with-transverse-auxiliary-switches-1-no-1-nc","title":"Siemens 3RV2411-1BA15 Circuit breaker size S00 for transformer protection A-release 1.4...2 A N release 42 A screw terminal Standard switching capacity with transverse auxiliary switches 1 NO+1 NC","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 1.4...2 A N release 42 A screw terminal Standard switching capacity with transverse auxiliary switches 1 NO+1 NC\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-1BA15\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-1BA15\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718906425429,"sku":"3RV2411-1BA15","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93053P_0bee245f-8642-4811-b44c-ac02c35d476c.png?v=1712664451"},{"product_id":"siemens-3rv2411-1ba20-circuit-breaker-size-s00-for-transformer-protection-a-release-1-4-2-a-n-release-42-a-spring-type-terminal-standard-switching-capacity","title":"Siemens 3RV2411-1BA20 Circuit breaker size S00 for transformer protection A-release 1.4...2 A N release 42 A Spring-type terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 1.4...2 A N release 42 A Spring-type terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-1BA20\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-1BA20\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718906458197,"sku":"3RV2411-1BA20","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93056P_e7b414eb-96b5-4d60-8dad-347e9492ee73.png?v=1712664474"},{"product_id":"siemens-3rv2411-1ca10-circuit-breaker-size-s00-for-transformer-protection-a-release-1-8-2-5-a-n-release-52-a-screw-terminal-standard-switching-capacity","title":"Siemens 3RV2411-1CA10 Circuit breaker size S00 for transformer protection A-release 1.8...2.5 A N release 52 A screw terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 1.8...2.5 A N release 52 A screw terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-1CA10\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-1CA10\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718906490965,"sku":"3RV2411-1CA10","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93050P_9c73e34d-a722-438d-9015-e397fa401ec6.png?v=1712664429"},{"product_id":"siemens-3rv2411-1ca20-circuit-breaker-size-s00-for-transformer-protection-a-release-1-8-2-5-a-n-release-52-a-spring-type-terminal-standard-switching-capacity","title":"Siemens 3RV2411-1CA20 Circuit breaker size S00 for transformer protection A-release 1.8...2.5 A N release 52 A Spring-type terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 1.8...2.5 A N release 52 A Spring-type terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-1CA20\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-1CA20\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718906589269,"sku":"3RV2411-1CA20","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93056P_e560a1e1-8b7f-4f94-9747-8ad816e3746f.png?v=1712664473"},{"product_id":"siemens-3rv2411-1da10-circuit-breaker-size-s00-for-transformer-protection-a-release-2-2-3-2-a-n-release-65-a-screw-terminal-standard-switching-capacity","title":"Siemens 3RV2411-1DA10 Circuit breaker size S00 for transformer protection A-release 2.2...3.2 A N release 65 A screw terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 2.2...3.2 A N release 65 A screw terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-1DA10\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-1DA10\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718906654805,"sku":"3RV2411-1DA10","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93050P_9f273dfc-edd2-4561-b18e-7c9bc411d9b5.png?v=1712664427"},{"product_id":"siemens-3rv2411-1da20-circuit-breaker-size-s00-for-transformer-protection-a-release-2-2-3-2-a-n-release-65-a-spring-type-terminal-standard-switching-capacity","title":"Siemens 3RV2411-1DA20 Circuit breaker size S00 for transformer protection A-release 2.2...3.2 A N release 65 A Spring-type terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 2.2...3.2 A N release 65 A Spring-type terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-1DA20\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-1DA20\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718906720341,"sku":"3RV2411-1DA20","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93056P_e9cce3b5-3c52-46bf-a727-b92c153f434d.png?v=1712664471"},{"product_id":"siemens-3rv2411-1ea10-circuit-breaker-size-s00-for-transformer-protection-a-release-2-8-4-a-n-release-82-a-screw-terminal-standard-switching-capacity","title":"Siemens 3RV2411-1EA10 Circuit breaker size S00 for transformer protection A-release 2.8...4 A N-release 82 A screw terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 2.8...4 A N-release 82 A screw terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-1EA10\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-1EA10\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718906753109,"sku":"3RV2411-1EA10","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93050P_2dcce389-d80c-4ea4-8ba4-b1bd581a3d62.png?v=1712664425"},{"product_id":"siemens-3rv2411-1ea20-circuit-breaker-size-s00-for-transformer-protection-a-release-2-8-4-a-n-release-82-a-spring-type-terminal-standard-switching-capacity","title":"Siemens 3RV2411-1EA20 Circuit breaker size S00 for transformer protection A-release 2.8...4 A N-release 82 A Spring-type terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 2.8...4 A N-release 82 A Spring-type terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-1EA20\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-1EA20\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718906818645,"sku":"3RV2411-1EA20","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93056P_5f33baf1-75e0-4f66-b0be-9f34ca2e0939.png?v=1712664469"},{"product_id":"siemens-3rv2411-1fa10-circuit-breaker-size-s00-for-transformer-protection-a-release-3-5-5-a-n-release-104-a-screw-terminal-standard-switching-capacity","title":"Siemens 3RV2411-1FA10 Circuit breaker size S00 for transformer protection A-release 3.5...5 A N-release 104 A screw terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 3.5...5 A N-release 104 A screw terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-1FA10\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-1FA10\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718906851413,"sku":"3RV2411-1FA10","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93050P_f03e0fe0-eb43-4021-a07c-89563d6994e8.png?v=1712664423"},{"product_id":"siemens-3rv2411-1fa15-circuit-breaker-size-s00-for-transformer-protection-a-release-3-5-5-a-n-release-104-a-screw-terminal-standard-switching-capacity-with-transverse-auxiliary-switches-1-no-1-nc","title":"Siemens 3RV2411-1FA15 Circuit breaker size S00 for transformer protection A-release 3.5...5 A N-release 104 A screw terminal Standard switching capacity with transverse auxiliary switches 1 NO+1 NC","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 3.5...5 A N-release 104 A screw terminal Standard switching capacity with transverse auxiliary switches 1 NO+1 NC\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-1FA15\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-1FA15\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718906884181,"sku":"3RV2411-1FA15","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93053P_97917449-2c63-4f8b-a40f-6ce92a5fe757.png?v=1712664449"},{"product_id":"siemens-3rv2411-1fa20-circuit-breaker-size-s00-for-transformer-protection-a-release-3-5-5-a-n-release-104-a-spring-type-terminal-standard-switching-capacity","title":"Siemens 3RV2411-1FA20 Circuit breaker size S00 for transformer protection A-release 3.5...5 A N-release 104 A Spring-type terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 3.5...5 A N-release 104 A Spring-type terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-1FA20\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-1FA20\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718906916949,"sku":"3RV2411-1FA20","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93056P_6cb0f9a1-7037-446b-bfa6-83002ecf6f0f.png?v=1712664468"},{"product_id":"siemens-3rv2411-1ga10-circuit-breaker-size-s00-for-transformer-protection-a-release-4-5-6-3-a-n-release-130-a-screw-terminal-standard-switching-capacity","title":"Siemens 3RV2411-1GA10 Circuit breaker size S00 for transformer protection A-release 4.5...6.3 A N release 130 A screw terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 4.5...6.3 A N release 130 A screw terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-1GA10\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-1GA10\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718906949717,"sku":"3RV2411-1GA10","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93050P_2ce2a8a7-b57a-4581-8d59-8d238c44390c.png?v=1712664415"},{"product_id":"siemens-3rv2411-1ga20-circuit-breaker-size-s00-for-transformer-protection-a-release-4-5-6-3-a-n-release-130-a-spring-type-terminal-standard-switching-capacity","title":"Siemens 3RV2411-1GA20 Circuit breaker size S00 for transformer protection A-release 4.5...6.3 A N release 130 A Spring-type terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 4.5...6.3 A N release 130 A Spring-type terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-1GA20\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-1GA20\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718907048021,"sku":"3RV2411-1GA20","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93056P_d9937075-124b-4a14-9332-7a854dcab0ec.png?v=1712664466"},{"product_id":"siemens-3rv2411-1ha10-circuit-breaker-size-s00-for-transformer-protection-a-release-5-5-8-a-n-release-163-a-screw-terminal-standard-switching-capacity","title":"Siemens 3RV2411-1HA10 Circuit breaker size S00 for transformer protection A-release 5.5...8 A N-release 163 A screw terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 5.5...8 A N-release 163 A screw terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-1HA10\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-1HA10\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718907080789,"sku":"3RV2411-1HA10","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93050P_f7953d81-5cab-4d61-8241-fddb1a6b0e6c.png?v=1712664412"},{"product_id":"siemens-3rv2411-1ha20-circuit-breaker-size-s00-for-transformer-protection-a-release-5-5-8-a-n-release-163-a-spring-type-terminal-standard-switching-capacity","title":"Siemens 3RV2411-1HA20 Circuit breaker size S00 for transformer protection A-release 5.5...8 A N-release 163 A Spring-type terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 5.5...8 A N-release 163 A Spring-type terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-1HA20\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-1HA20\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718907211861,"sku":"3RV2411-1HA20","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93056P_c1b75c9d-c4b7-42e7-98dd-41ddb7ceb6ec.png?v=1712664465"},{"product_id":"siemens-3rv2411-1ja10-circuit-breaker-size-s00-for-transformer-protection-a-release-7-10-a-n-release-208-a-screw-terminal-standard-switching-capacity","title":"Siemens 3RV2411-1JA10 Circuit breaker size S00 for transformer protection A-release 7...10 A N-release 208 A screw terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 7...10 A N-release 208 A screw terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-1JA10\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-1JA10\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718907244629,"sku":"3RV2411-1JA10","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93050P_d17da731-e26e-40f4-af1e-59b733c8d492.png?v=1712664410"},{"product_id":"siemens-3rv2411-1ja20-circuit-breaker-size-s00-for-transformer-protection-a-release-7-10-a-n-release-208-a-spring-type-terminal-standard-switching-capacity","title":"Siemens 3RV2411-1JA20 Circuit breaker size S00 for transformer protection A-release 7...10 A N-release 208 A Spring-type terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 7...10 A N-release 208 A Spring-type terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-1JA20\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-1JA20\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718907342933,"sku":"3RV2411-1JA20","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93056P_86b05fc0-6d4f-47bc-a84e-4092cd2ba540.png?v=1712664463"},{"product_id":"siemens-3rv2411-1ka10-circuit-breaker-size-s00-for-transformer-protection-a-release-9-12-5-a-n-release-260-a-screw-terminal-standard-switching-capacity","title":"Siemens 3RV2411-1KA10 Circuit breaker size S00 for transformer protection A-release 9...12.5 A N-release 260 A screw terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 9...12.5 A N-release 260 A screw terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-1KA10\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-1KA10\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718907375701,"sku":"3RV2411-1KA10","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93050P_1afd7dde-9c7e-4852-b6f8-9a6729b2c934.png?v=1712664407"},{"product_id":"siemens-3rv2411-1ka15-circuit-breaker-size-s00-for-transformer-protection-a-release-9-12-5-a-n-release-260-a-screw-terminal-standard-switching-capacity-with-transverse-auxiliary-switches-1-no-1-nc","title":"Siemens 3RV2411-1KA15 Circuit breaker size S00 for transformer protection A-release 9...12.5 A N-release 260 A screw terminal Standard switching capacity with transverse auxiliary switches 1 NO+1 NC","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 9...12.5 A N-release 260 A screw terminal Standard switching capacity with transverse auxiliary switches 1 NO+1 NC\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-1KA15\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-1KA15\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718907408469,"sku":"3RV2411-1KA15","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93053P.png?v=1712664448"},{"product_id":"siemens-3rv2411-1ka20-circuit-breaker-size-s00-for-transformer-protection-a-release-9-12-5-a-n-release-260-a-spring-type-terminal-standard-switching-capacity","title":"Siemens 3RV2411-1KA20 Circuit breaker size S00 for transformer protection A-release 9...12.5 A N-release 260 A Spring-type terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 9...12.5 A N-release 260 A Spring-type terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-1KA20\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-1KA20\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718907441237,"sku":"3RV2411-1KA20","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93056P_bb83f1c4-2b9a-4125-bd04-b6009155cea8.png?v=1712664461"},{"product_id":"siemens-3rv2411-4aa10-circuit-breaker-size-s00-for-transformer-protection-a-release-10-16-a-n-release-286-a-screw-terminal-standard-switching-capacity","title":"Siemens 3RV2411-4AA10 Circuit breaker size S00 for transformer protection A-release 10...16 A N-release 286 A screw terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 10...16 A N-release 286 A screw terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-4AA10\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-4AA10\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718907474005,"sku":"3RV2411-4AA10","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93050P.png?v=1712664405"},{"product_id":"siemens-3rv2411-4aa20-circuit-breaker-size-s00-for-transformer-protection-a-release-10-16-a-n-release-286-a-spring-type-terminal-standard-switching-capacity","title":"Siemens 3RV2411-4AA20 Circuit breaker size S00 for transformer protection A-release 10...16 A N-release 286 A Spring-type terminal Standard switching capacity","description":"\u003cp\u003eCircuit breaker size S00 for transformer protection A-release 10...16 A N-release 286 A Spring-type terminal Standard switching capacity\u003c\/p\u003e\u003cbr\u003e\u003ca href=\"https:\/\/mall.industry.siemens.com\/tedservices\/DatasheetService\/DatasheetService?format=PDF\u0026amp;caller=PDPS\u0026amp;mlfbs=3RV2411-4AA20\u0026amp;language=en\" class=\"button button--primary\"\u003e DOWNLOAD DATASHEET\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/product\/3RV2411-4AA20\" class=\"button button--primary\"\u003e VIEW MORE PRODUCT DETAILS\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=r5Le5rO_66U?%C2%B7%20class=\" button button--primary\u003eVIEW ON YOUTUBE\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.industry-mobile-support.siemens-info.com\/#\/en\/article\/109824486\" class=\"button button--primary\"\u003eVIEW EPD DETAILS\u003c\/a\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":32718907572309,"sku":"3RV2411-4AA20","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/G_NSA0_XX_93056P.png?v=1712664460"}],"url":"https:\/\/www.gilautomation.com\/en-ao\/collections\/transformers.oembed?page=3","provider":"gilautomation","version":"1.0","type":"link"}