{"product_id":"fluke-1623-2-basic-geo-earth-ground-tester","title":"Fluke 1623-2 Basic Geo Earth Ground Tester (non-Kit version)","description":"\u003ch2\u003eProduct overview: Fluke 1623-2 GEO Earth Ground Tester\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003eThe Fluke 1623-2 GEO Earth Ground Tester offers data storage and download capabilities via USB port. World class accessories will simplify and speed up testing time.\u003c\/p\u003e\n\u003cp\u003eFluke 1623-2 GEO Earth Ground Tester summary\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3- and 4-pole Fall-of-Potential, earth resistance loop testing\u003c\/li\u003e\n\u003cli\u003e4-pole Soil Resistivity testing\u003c\/li\u003e\n\u003cli\u003eSelective earth ground rod testing using 1 clamp\u003c\/li\u003e\n\u003cli\u003eStakeless earth ground rod testing using 2 clamps\u003c\/li\u003e\n\u003cli\u003eIP56 rated for outdoor use\u003c\/li\u003e\n\u003cli\u003eRugged carrying case\u003c\/li\u003e\n\u003cli\u003eUSB data storage and transfer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 1623-2 GEO Earth Ground Tester\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay: 1999 digit LCD\u003c\/td\u003e\n\u003ctd\u003eDisplay with special symbols, digit height 25 mm, fluorescent backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser interface\u003c\/td\u003e\n\u003ctd\u003eInstant measurement through TURN and START one button concept. The only operating elements are rotary switch and START button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRobust, water and dust resistant\u003c\/td\u003e\n\u003ctd\u003eInstrument is designed for tough environmental conditions (rubber protective cover, IP56)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eInternal memory storage up to 1500 records accessible via USB port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eTemperature Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to 50°C (14°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to 60°C (-22°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd\u003e±0.1% of reading\/°C \u0026lt; 18°C \u0026gt; 28°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic error\u003c\/td\u003e\n\u003ctd\u003eRefers to the reference temperature range and is guaranteed for 1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003eRefers to the operating temperature range and is guaranteed for 1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClimatic class\u003c\/td\u003e\n\u003ctd\u003eC1 (IEC 654-1), -5°C to +45°C (23° to +115° F), 5% to 95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective type\u003c\/td\u003e\n\u003ctd\u003eIP56 for case, IP40 for battery door according to EN60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eProtection by double and\/or reinforced insulation. max. 50 V to earth. IEC61010-1: Pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC (emission immunity)\u003c\/td\u003e\n\u003ctd\u003eIEC61326-1: Portable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality system\u003c\/td\u003e\n\u003ctd\u003eDeveloped, designed and manufactured according to DIN ISO 9001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal voltage\u003c\/td\u003e\n\u003ctd\u003eV ext, max = 24 V (DC, AC \u0026lt; 400 Hz), measurement inhibited for higher values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eV ext rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 120 dB (162⁄3, 50, 60, 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd\u003eTypical 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. overload\u003c\/td\u003e\n\u003ctd\u003e250 V rms (pertains to misuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary power\u003c\/td\u003e\n\u003ctd\u003e6 x 1.5 V Alkaline (type AA LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life span\u003c\/td\u003e\n\u003ctd\u003eTypical \u0026gt; 3,000 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.1 kg (2.43 lb) including batteries\u003cbr\u003e7.6 kg (16.8 lb) incl. accessories and batteries in carrying case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eRA 3-Pole Ground Resistance Measurement (IEC 1557-5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e3-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(2% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(5% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Current\/Voltage Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe resistance (R\u003csub\u003eS\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary earth electrode resistance (R\u003csub\u003eH\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional error from R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eH\u003c\/sub\u003e[kΩ]•••R\u003csub\u003eS\u003c\/sub\u003e[kΩ]\/R\u003csub\u003eA\u003c\/sub\u003e[Ω]•••0.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold\"\u003eMonitoring of R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith error indicator.\u003cbr\u003eAutomatic range selection.\u003cbr\u003eMeasurement is not performed if the current through the current clamp is too low.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-Pole Ground Resistance Measurement (IEC 1557-5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(2% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(5% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Current\/Voltage Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe resistance (R\u003csub\u003eS +\u003cspan\u003e \u003c\/span\u003e\u003c\/sub\u003eR\u003csub\u003eES\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary earth electrode resistance (R\u003csub\u003eH\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional error from R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eH\u003c\/sub\u003e[kΩ]•••R\u003csub\u003eS\u003c\/sub\u003e[kΩ]\/R\u003csub\u003eA\u003c\/sub\u003e[Ω]•••0.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold\"\u003eMonitoring of R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith error indicator.\u003cbr\u003eAutomatic range selection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eRA 3-Pole Selective Ground Resistance Measurement with Current Clamp (R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith Clamp )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e3-pole with clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(7% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(10% rdg + 5 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Current\/Voltage Measurement (with External Current Clamp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe resistance (R\u003csub\u003eS\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary earth electrode resistance (R\u003csub\u003eH\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold\"\u003eMonitoring of R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith error indicator.\u003cbr\u003eAutomatic range selection.\u003cbr\u003eMeasurement is not performed if the current through the current clamp is too low.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eRA 4-Pole Selective Ground Resistance Measurement with Current Clamp (R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith Clamp )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole with clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(7% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(10% rdg + 5 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Current\/Voltage Measurement (with External Current Clamp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128\u003cbr\u003e Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe resistance (R\u003csub\u003eS\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary earth electrode resistance (R\u003csub\u003eH\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold\"\u003eMonitoring of R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith error indicator.\u003cbr\u003eAutomatic range selection.\u003cbr\u003eMeasurement is not performed if the current through the current clamp is too low.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eStakeless Ground Loop Measurement (2 Clamps )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole 2 clamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(7% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(10% rdg + 5 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Stakeless Measurement of Resistance in Closed Loops Using Two Current Transformers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eNoise current (I\u003csub\u003eEXT\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax. I\u003csub\u003eEXT\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 10 A (AC) (R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e\u0026lt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eMax. I\u003csub\u003eEXT\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 2 A (AC) (R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold\"\u003eAutomatic range selection.\u003cbr\u003eThe information regarding stakeless ground loop measurements is only valid when used in conjunction with the recommended current clamps at the minimum distance specified.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434187665493,"sku":"Fluke 1623-2","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/6_22932f3c-bf9f-40eb-92fe-becc79f3975a.jpg?v=1592218782","url":"https:\/\/www.gilautomation.com\/en-ao\/products\/fluke-1623-2-basic-geo-earth-ground-tester","provider":"gilautomation","version":"1.0","type":"link"}