{"product_id":"fluke-1662-sch-installation-tester-w-mem-schuko","title":"Fluke 1662 SCH Installation Tester w\/mem Schuko","description":"\u003cp\u003eProduct overview: Fluke 1662 Multifunction Testers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 1662 Multifunction Installation Tester delivers solid, basic installation testing features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1662 installation tester gives you Fluke reliability and all the basic testing power you need for day-in, day-out installation testing. It tests to all local regulations and is easy and intuitive to use. Additional helpful features like the On\/Off switchable auto-start for RCD and loop test, and self-test save time and give you more confidence in your results.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures RCD switching time and tripping level (ramp test)\u003c\/li\u003e\n\u003cli\u003eMeasures trip time and current for RCD type A \u0026amp; AC in one test\u003c\/li\u003e\n\u003cli\u003eMeasures RCD variable current\u003c\/li\u003e\n\u003cli\u003eProvides automatic RCD test sequence\u003c\/li\u003e\n\u003cli\u003eIncludes Z-max memory for loop tests to support easy evaluation of the highest loop test value\u003c\/li\u003e\n\u003cli\u003eProvides unique zero adapter for fast, reliable and accurate test lead and mains cord compensation\u003c\/li\u003e\n\u003cli\u003eIncludes a phase sequence indicator\u003c\/li\u003e\n\u003cli\u003eComes with hard carrying case, padded carrying and waist strap, and remote control probe and lead\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA solid, reliable, basic installation tester\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTests voltage and frequency\u003c\/li\u003e\n\u003cli\u003eChecks wiring polarity to detect broken N wires\u003c\/li\u003e\n\u003cli\u003eMeasures insulation resistance and loop and line resistance\u003c\/li\u003e\n\u003cli\u003eMeasures motor windings with continuity test\u003c\/li\u003e\n\u003cli\u003eCalculates prospective earth fault current (PEFC\/IK) and prospective short-circuit current (PSC\/IK)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 1662 Multifunction Testers\u003c\/h2\u003e\n\u003ctable width=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003e\u003cstrong\u003eAC voltage measurement\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"301\"\u003e\n\u003cp\u003eRange\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e500 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eResolution\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e0.1 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAccuracy 45 Hz – 66 Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e0.8% + 3\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInput impedance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e360 kΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOverload protection\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e660 V rms\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eContinuity testing (RLO)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRange (autoranging)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e20 Ω \/ 200 Ω \/ 2000 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eResolution\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e0.01 Ω \/ 0.1 Ω \/ 1 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOpen Circuit Voltage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u0026gt;4 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eInsulation resistance measurement (RISO)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAccuracy of tTest voltage (at rated test current)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e+10%, -0%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTest voltage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e100 V\u003cbr\u003e 250 V\u003cbr\u003e 500 V\u003cbr\u003e 1000 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInsulation resistance range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e20 MΩ \/ 50 MΩ\u003cbr\u003e 20 MΩ \/ 100 MΩ\u003cbr\u003e 20 MΩ \/ 200 MΩ\u003cbr\u003e 20 MΩ \/ 200 MΩ \/ 500 MΩ\u003cbr\u003e 20 MΩ \/ 200 MΩ \/ 1000 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eResolution\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e0.01 MΩ \/ 0.1 MΩ\u003cbr\u003e 0.01 MΩ \/ 0.1 MΩ\u003cbr\u003e 0.01 MΩ \/ 0.1 MΩ\u003cbr\u003e 0.01 MΩ \/ 0.1 MΩ \/ 1 MΩ\u003cbr\u003e 0.01 MΩ \/ 0.1 MΩ \/ 1 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTest current\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e1 mA @ 50 kΩ\u003cbr\u003e 1 mA @ 100 kΩ\u003cbr\u003e 1 mA @ 250 kΩ\u003cbr\u003e 1 mA @ 500 kΩ\u003cbr\u003e 1 mA @ 1 MΩ\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eLoop and line impedance (ZI)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRange\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e10 Ω \/ 0.001 Ω \/ High current mΩ mode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eResolution\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e0.01 Ω \/ 0.1 Ω \/ 1 Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eProspective earth fault current, PSC test\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRange\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e1000 A \/ 10 kA (50 kA)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eResolution\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e1 A \/ 0.1 kA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eComputation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eProspective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eRCD testing, RCD types tested\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRCD Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eA\u003csup\u003e4\u003c\/sup\u003e, AC¹, G², S³\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNotes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e¹Responds to AC\u003cbr\u003e ²General, no delay\u003cbr\u003e ³Time delay\u003cbr\u003e \u003csup\u003e4\u003c\/sup\u003eResponds to pulsed signal\u003cbr\u003e \u003csup\u003e5\u003c\/sup\u003eResponds to smooth DC signal\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eTripping speed test (ΔT)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCurrent settings¹\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e10-30-100-300-500-1000 mA – VAR\u003cbr\u003e 10-30-100 mA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMultiplier\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003ex ½, x 1\u003cbr\u003e x 5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\n\u003cp\u003eMeasurement range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRCD Type G\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e310 ms\u003cbr\u003e 50 ms\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRCD Type S\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e510 ms\u003cbr\u003e 160 ms\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNotes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e¹1000 mA type AC only\u003cbr\u003e 700 mA maximum type A in VAR mode\u003cbr\u003e VAR mode not available for type B.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eRCD\/FI-Tripping Current Measurement\/Ramp Test (IΔN)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCurrent range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e30% to 110% of RCD rated current¹\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStep size\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e10% of IΔN²\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\n\u003cp\u003eDwell time\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eType G\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e300 ms\/step\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eType S\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e500 ms\/step\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMeasurement accuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e±5%\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSpecified trip current ranges (EN 61008-1)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e50% to 100% for Type AC\u003cbr\u003e 35% to 140% for Type A (\u0026gt;10 mA)\u003cbr\u003e 35% to 200% for Type A (≤10 mA)\u003cbr\u003e 50% to 200% for Type B\u003cbr\u003e ²5% for Type B\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNotes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e¹30% to 150% for Type A IΔN \u0026gt; 10 mA\u003cbr\u003e 30% to 210% for Type A IΔN = 10 mA\u003cbr\u003e 20% to 210% for Type B\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003ePhase Sequence Indication\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIcon\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e Phase Sequence indicator is active.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003cp\u003eGeneral Specifications\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSize (L x W x H)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e10 x 25 x 12.5 cm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight (incl. batteries)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e1.3 Kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eBattery size, quantity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eType AA, 6 ea.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSealing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eIP-40\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSafety\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eComplies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI\/ISA –s82.02.01 2000 and CAN\/CSA c22.2 No. 1010 2nd edition\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOvervoltage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eCAT III \/ 500V; CAT IV 300V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePerformance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003eEN61557-1 to EN61557-7 Second Edition and EN61557-10 Second Edition\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434186551381,"sku":"Fluke 1662 SCH","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/1e_b313deeb-608a-4d8c-843f-c2d5412a0811.jpg?v=1592224611","url":"https:\/\/www.gilautomation.com\/en-ao\/products\/fluke-1662-sch-installation-tester-w-mem-schuko","provider":"gilautomation","version":"1.0","type":"link"}