{"product_id":"fluke-1664fc-uk-fc-installation-tester-w-insulation-pre-test-uk","title":"Fluke 1664FC UK Installation Tester w\/Insulation Pre-Test UK","description":"\u003ch2 data-mce-fragment=\"1\"\u003eProduct overview: Fluke 1664 FC Installation Multifunction Testers\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\" data-mce-fragment=\"1\"\u003e\n\u003cdiv id=\"product-overview\" data-mce-fragment=\"1\"\u003e\n\u003cdiv id=\"overview_content\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFluke 1664 FC Multifunction Installation Tester helps expedite installations\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe 1664 FC puts a lot of testing power in your hands to quickly and efficiently test to all local regulations, protect appliances, and share test results in real time over your smartphone.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eProtect appliances from accidental damage\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Fluke 1664 FC is the only tester with \"Insulation PreTest\" that stops the insulation test and provides a visual warning if it detects that an appliance is connected to the system under test. This helps you avoid potentially serious and costly mistakes that can cause damage to your customers’ peripheral equipment.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAuto Test reduces test time\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAuto Test performs up to seven installation tests in one sequence, ensuring compliance with local installation regulations. This reduces the number of manual connections, thus decreasing the possibility of errors and reducing test time.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSave time and enhance collaboration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eBecause the 1664 FC is Fluke Connect®-enabled, you can send test results to your smartphone, save them to the cloud, and share measurements in real time with team members through a ShareLive video call. It's the fastest way to let your team see what you see, and to help you get approvals without leaving the field.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eRetrieve stored results from anywhere\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eFluke Cloud™ storage allows you to retrieve stored results whether you are in the office or in the field to make decisions in real time. You get world-class data protection and you can import the data into Fluke DMS (Data Management Software) to process and generate certificates.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eOther helpful features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCompact, lightweight (less than 1.3 kg) with padded neck-strap to free your hands\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRotary dial knob clearly indicates which function is selected, all in one spot with no complex multi-level menus.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eOffers additional high current loop mode for faster measurements than loop tests with non-trip mode for RCDs\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIncludes Z-max memory for loop tests to support easy evaluation of the highest loop test value\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eProvides unique zero adapter for fast, reliable and accurate test lead and mains cord compensation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePerforms fast voltage measurement between L-N, L-PE, and N-PE using the mains cord. No need to change measurement connections\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeasures RCD trip current and trip time in parallel (RCD type AC and A)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeasures PEFC or PSC and loop impedance in parallel and displays them together on the dual display\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eOffers ring testing so you can select the required input sockets with soft keys and not have to exchange test leads\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUses continuity test currents to measure motor windings\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDetects raised earth voltages \u0026gt; 50 V with Earth Volt Touchpad, indicating potential dangerous situations\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFeatures large display with backlight, clear symbols, and exceptionally wide viewing angle for easy and safe readings\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eOffers extended three-layer memory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv aria-expanded=\"true\" data-readmore=\"\" id=\"keyfeature_content\"\u003eMultifunction tester that tests to all local regulations\n\u003cul\u003e\n\u003cli\u003eIncludes \"Insulation Pre-test\" that detects when appliances are connected to the system and stops the test\u003c\/li\u003e\n\u003cli\u003eRuns seven installation tests automatically in one sequence with a single connection through Auto Test\u003c\/li\u003e\n\u003cli\u003eAllows you to share test results in real time over your smartphone via Fluke Connect Measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 1664 FC Installation Multifunction Testers\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003e\u003cspan\u003eAC voltage measurement\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e500 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e0.1 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eAccuracy 45 Hz – 66 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e0.8% + 3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eInput impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e360 kΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eOverload protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e660 V rms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003e\u003cspan\u003eContinuity testing (RLO)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eRange (autoranging)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e20 Ω \/ 200 Ω \/ 2000 Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e0.01 Ω \/ 0.1 Ω \/ 1 Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eOpen Circuit Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e\u0026gt;4 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003e\u003cspan\u003eInsulation resistance measurement (RISO)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eTest voltages\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e50-100-250-500-1000 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eAccuracy of tTest voltage (at rated test current)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e+10%, -0%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eTest voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e50 V\u003cbr\u003e100 V\u003cbr\u003e250 V\u003cbr\u003e500 V\u003cbr\u003e1000 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eInsulation resistance range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e20 MΩ \/50 MΩ\u003cbr\u003e20 MΩ \/ 100 MΩ\u003cbr\u003e20 MΩ \/ 200 MΩ\u003cbr\u003e20 MΩ \/ 200 MΩ \/ 500 MΩ\u003cbr\u003e20 MΩ \/ 200 MΩ \/ 1000 MΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e0.01 MΩ \/ 0.1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ \/ 1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ \/ 1 MΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eTest current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e1 mA @ 50 kΩ\u003cbr\u003e1 mA @ 100 kΩ\u003cbr\u003e1 mA @ 250 kΩ\u003cbr\u003e1 mA @ 500 kΩ\u003cbr\u003e1 mA @ 1 MΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003e\u003cspan\u003eLoop and line impedance (ZI)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e10 Ω \/ 0.001 Ω \/ High current mΩ mode\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e0.01 Ω \/ 0.1 Ω \/ 1 Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003e\u003cspan\u003eProspective earth fault current, PSC test\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e1000 A \/ 10 kA (50 kA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e1 A \/ 0.1 kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eComputation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003eProspective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003e\u003cspan\u003eRCD testing, RCD types tested\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eRCD Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003eAC¹\u003cbr\u003eG²,S³\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eModel 1664\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003eA, AC, B\u003csup\u003e5\u003c\/sup\u003e, S\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eNotes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e¹Responds to AC\u003cbr\u003e²General, no delay\u003cbr\u003e³Time delay\u003cbr\u003e\u003csup\u003e4\u003c\/sup\u003eResponds to pulsed signal\u003cbr\u003e\u003csup\u003e5\u003c\/sup\u003eResponds to smooth DC signal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003e\u003cspan\u003eTripping speed test (ΔT)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eCurrent settings¹\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e10-30-100-300-500-1000 mA – VAR\u003cbr\u003e10-30-100 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eMultiplier\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003ex ½, x 1\u003cbr\u003ex 5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 181px;\"\u003e\u003cspan\u003eMeasurement range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003e\u003cspan\u003eRCD Type G\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 210px;\"\u003e\u003cspan\u003e310 ms\u003cbr\u003e50 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 113px;\"\u003e\u003cspan\u003eRCD Type S\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 210px;\"\u003e\u003cspan\u003e510 ms\u003cbr\u003e160 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eNotes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e¹1000 mA type AC only\u003cbr\u003e700 mA maximum type A in VAR mode\u003cbr\u003eVAR mode not available for type B.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003e\u003cspan\u003eRCD\/FI-Tripping Current Measurement\/Ramp Test (IΔN)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eCurrent range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e30% to 110% of RCD rated current¹\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eStep size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e10% of IΔN²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 181px;\"\u003e\u003cspan\u003eDwell time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003e\u003cspan\u003eType G\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 210px;\"\u003e\u003cspan\u003e300 ms\/step\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 113px;\"\u003e\u003cspan\u003eType S\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 210px;\"\u003e\u003cspan\u003e500 ms\/step\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eMeasurement accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e±5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eSpecified trip current ranges (EN 61008-1)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e50% to 100% for Type AC\u003cbr\u003e35% to 140% for Type A (\u0026gt;10 mA)\u003cbr\u003e35% to 200% for Type A (≤10 mA)\u003cbr\u003e50% to 200% for Type B\u003cbr\u003e²5% for Type B\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eNotes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e¹30% to 150% for Type A IΔN \u0026gt; 10 mA\u003cbr\u003e30% to 210% for Type A IΔN = 10 mA\u003cbr\u003e20% to 210% for Type B\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003e\u003cspan\u003eEarth Resistance Test (RE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e200 Ω \/ 2000 Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e0.1 Ω \/ 1Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eFrequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e128 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eOutput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e25 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003e\u003cspan\u003ePhase Sequence Indication\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eIcon\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/icon_phase_sequence_indicator.png\" alt=\"icon phase sequence indicator\" align=\"top\"\u003e Phase Sequence indicator is active.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003e\u003cspan\u003eGeneral Specifications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eSize (L x W x H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e10 x 25 x 12.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eWeight (incl. batteries)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e1.3 Kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eBattery size, quantity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003eType AA, 6 ea.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eSealing\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003eIP-40\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eSafety\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003eComplies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI\/ISA –s82.02.01 2000 and CAN\/CSA c22.2 No. 1010 2nd edition\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eOvervoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003eCAT III \/ 500V; CAT IV 300V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003ePerformance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003eEN61557-1 to EN61557-7 Second Edition and EN61557-10 Second Edition\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434186649685,"sku":"Fluke 1664FC UK","price":939153.6,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/Fluke-1664FC-30060461-01.jpg?v=1600256990","url":"https:\/\/www.gilautomation.com\/en-ao\/products\/fluke-1664fc-uk-fc-installation-tester-w-insulation-pre-test-uk","provider":"gilautomation","version":"1.0","type":"link"}