{"product_id":"fluke-1742-15-intl-power-quality-logger-with-60cm-1500a-iflex-intl-version","title":"Fluke 1742\/15\/INTL Power Quality Logger with 60 cm 1,500A iFLex, INTL version","description":"\u003ch2\u003eProduct overview: Fluke 1742, 1746 and 1748 Three-Phase Power Quality Loggers\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003eThe Fluke 1742, 1746 and 1748 Three-Phase Power Quality Loggers give you fast, easy access to the data you need to make critical power quality and energy decisions in real-time. With the included\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.fluke.com\/en\/support\/software-downloads\/fluke-energy-analyze-plus\"\u003eEnergy Analyze Plus\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003esoftware package you can easily create detailed reports.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUpgrade according to future needs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1748 logs over 500 different parameters for each averaging period. This allows you to analyze power quality in detail and to correlate intermittent events with detailed waveform data, helping to identify the root cause of disturbances. For basic power quality logging, the Fluke 1746 captures all relevant power parameters for performing energy saving studies and electrical network planning with a full upgrade option to 1748 available. For simple load and energy studies the Fluke 1742 offers optimal performance in a rugged package and can be upgraded to 1746, or complete 1748, functionality.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNational and international standards\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompact and rugged, the Fluke 1740 Series Three-Phase Power Quality Loggers are designed specifically for technicians and engineers who need the flexibility to troubleshoot, quantify energy usage and analyze power distribution systems. Fully compliant with international power quality standards such as IEC 61000-4-30 Class A and capable of simultaneously logging up to 500 parameters while also capturing events, the Fluke 1740 Series helps uncover intermittent and hard-to-find power quality issues more easily than ever.\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.fluke.com\/en\/support\/software-downloads\/fluke-energy-analyze-plus\"\u003eEnergy Analyze Plus\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003esoftware quickly assesses the quality of power at the service entrance, substation, or at the load, according to national and international standards including EN 50160 and IEEE 519.\u003c\/p\u003e\n\u003cp\u003eAn optimized user interface, flexible current probes, and an intelligent measurement verification function that allows you to digitally verify and correct connections makes setup easier than ever and reduces measurement uncertainty. Minimize your time in potentially hazardous environments and reduce the hassle of suiting up in PPE by using a wireless connection (Wi-Fi) to view data directly in the field.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnalysis and reporting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCapturing logged data is just one part of the task. Once you have the data, you need to create useful information and reports that can be easily shared and understood by your organization or customers. Fluke\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.fluke.com\/en\/support\/software-downloads\/fluke-energy-analyze-plus\"\u003eEnergy Analyze Plus\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003esoftware makes that task as simple as possible. With powerful analysis tools and the ability to create customized reports in minutes you’ll be able to communicate your findings and quickly solve problems so you can optimize system reliability and savings. A range of built-in report templates for industry standards such as EN 50160, IEEE 519 and GOST enable one-click reporting so you can create high quality reports at the touch of a button. Reports can be modified as standards evolve, or new versions become available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich power logger is right for you?\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003e1742\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003e1746\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003e1748\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage, current, power, power factor, frequency\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy forward\/reverse\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Demand\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlicker\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage and current harmonics (to 50th)\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnbalance\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRapid voltage change events\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterharmonics (to 50th)\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDips, swells, interruption and transient events tables\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush current\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransients (low frequency) \/ Waveform deviation events\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" align=\"left\"\u003e\u003cstrong\u003eRecording\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrend\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform snapshots\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRMS profile\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" align=\"left\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB (mini B)\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWi-Fi download Instrument to device\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWi-Fi download via Wi-Fi hub (free with registration)\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eOpt.\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eOpt.\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eOpt.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eIncluded accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible current probe\u003c\/td\u003e\n\u003ctd align=\"center\"\u003enot \/B version\u003c\/td\u003e\n\u003ctd align=\"center\"\u003enot \/B version\u003c\/td\u003e\n\u003ctd align=\"center\"\u003enot \/B version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB stick\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB cable\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3PHVL-17XX cable assembly\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLUKE-17XX-TL 0.18M test lead set\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLUKE-17XX-TL 2M test lead set\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlligator clips\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e4\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e4\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e173x\/174x Soft Case\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable marker kit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMP1-3R\/1B-Magnet Probe 1 set (3 red, 1 black)\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eOpt.\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e1\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e174x-Hanger Kit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eOpt.\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eOpt.\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\"In-workshop\" or \"in-the-field\" setup and download through PC application software:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esimple download using USB memory stick, Wi-Fi download, wired Ethernet connection or via USB cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.fluke.com\/en\/support\/software-downloads\/fluke-energy-analyze-plus\"\u003eEnergy Analyze Plus\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eapplication software:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDownload and analyze every measured detail of energy consumption and power quality state-of-health with automated reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne-touch reporting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCreate standardized reports according to commonly used standards like EN 50160, IEEE 519, GOST 33073 or export data in PQDIF or NeQual compatible format for use with third party software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced analysis:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eChoose any available logged parameter to create a highly customized view of logged measurements for advanced correlation of data.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasure all three voltage and current phases plus the neutral current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThree-phase and neutral voltage leads and four flexible current probes or optional current clamps for CT secondary current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive logging:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMore than 20 separate logging sessions can be stored in the instrument. A comprehensive range of power and power quality variables are automatically logged so you never lose measurement trends.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasure with premium accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMeets the rigorous IEC 61000-4-30 Class A Edition 3 standard for ‘Testing and measurement techniques–Power quality measurement methods.'\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapture dips, swells and interruptions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1748 includes event waveform capture and RMS event profile, along with date, timestamp and severity information to help pinpoint potential root causes of power quality issues.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasure key power quality parameters:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMeasures harmonics and interharmonics for voltage and current, also includes unbalance, flicker and rapid voltage changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized user interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCapture the right data every time with quick, guided, graphical PC based application setup and reduce uncertainty about your connections with an intelligent verification feature and the only auto-correction function for a power quality logger. Connection errors are automatically indicated via an amber light on the unit’s power button, this light turns green once corrected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized user interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eQuick, guided, graphical setup ensures you’re capturing the right data every time, and the intelligent verification function indicates correct connections have been made, reducing user uncertainty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible power supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePowers directly from the measured circuit with the widest available range for a power quality logger automatically going from 100 V to 500 V or from a wall line cord, so you can test anywhere.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged and reliable:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned to withstand harsh installation environments with IP65 rating when used with IP65 voltage input adapter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo external USB ports:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOne for PC connection and another for quick, simple data download to standard USB thumb drives, allowing you to leave the measurement device in place and download without disrupting logging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWired and wireless connections for instrument setup and high-speed data download.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned to fit in tight spaces and panels with small 23 cm x 18 cm x 5.4 cm (9.1 in x 7.1 in x 2.1 in) footprint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighest safety rating in the industry:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e600 V CAT IV\/1000 V CAT III rated for use at the service entrance and downstream.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized measurement accessories:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnique tangle-free flat voltage cable and thin flexible current probes ensure easy installation even in tight spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery life:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFour-hour operating time (backup time) per charge on lithium-ion battery to withstand temporary power disruptions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecurity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSafeguard your best asset from theft with a standard chain or other security device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnetic hanger kit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConveniently stow the instrument safely inside or outside of electrical panels; compatible with all models and included with 1748 model as standard.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 1742, 1746 and 1748 Three-Phase Power Quality Loggers\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\" class=\"v-top\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\" class=\"v-top\"\u003eAccuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eParameter\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e\u003cstrong\u003eMaximum Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e\u003cstrong\u003eIntrinsic Accuracy at Reference Conditions (% of Reading +% of Range)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eVoltage\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1000 V\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e±0.1 % of nominal voltage \u003csup\u003e1, 2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"8\" class=\"v-top\"\u003eCurrent: Direct input\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003ei17xx-flex 1500IP 24 1500 A\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e150 A\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.01 A (min. 1.5A)\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\" class=\"v-top\"\u003e±(1% + 0.02%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003e1500 A\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003ei17xx-flex 3000IP 24 3000 A\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e300 A\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.01 A (min. 3.0 A)\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\" class=\"v-top\"\u003e±(1% + 0.03%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003e3000 A\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003ei17xx-flex 6000IP 36 6000 A\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e600 A\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.01 A (min. 6.0 A)\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\" class=\"v-top\"\u003e±(1.5% + 0.03%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003e6000 A\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003ei40s-EL clamp\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e4 A\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1 mA\u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\" class=\"v-top\"\u003e±(0.7% + 0.02%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003e40 A\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eFrequency\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e42.5 Hz to 69 Hz\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.01 Hz\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e±(0.1%)\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eAuxiliary input\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e±10 V dc\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.1 mV\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e±(0.2% + 0.02%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eVoltage min\/max\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1000 V\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e±0.2 % of nominal input voltage\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eCurrent min\/max\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eDefined by accessory\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eDefined by accessory\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e±(5% + 0.2%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eTHD on voltage\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1000%\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.10%\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e± 2.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eTHD on current\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1000%\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.10%\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e± 2.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\" class=\"v-top\"\u003eVoltage harmonics 2nd to 50th\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e1000 V\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e≥ 1 V: ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e\u0026lt; 1 V: ±0.05V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\" class=\"v-top\"\u003eCurrent harmonics 2nd to 50th\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003eDefined by accessory\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003eDefined by accessory\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e≥ 3% of current range: ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e\u0026lt; 3% of current range: ±0.15% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eFlicker P\u003csub\u003eLT\u003c\/sub\u003e, P\u003csub\u003eST\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0 to 20\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.01\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\" class=\"v-top\"\u003eCurrent probe accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e\u003cstrong\u003eInfluence quantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e\u003cstrong\u003eiFlex1500IP-24\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e\u003cstrong\u003eiFlex3000IP-24 \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e\u003cstrong\u003eiFlex6000IP-36\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e\u003cstrong\u003ei40S-EL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003e\u003cstrong\u003e150 A \/ 1500 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e\u003cstrong\u003e300 A \/ 3000 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e\u003cstrong\u003e600 A \/ 6000 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e\u003cstrong\u003e4 A \/ 40 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eActive Power P \u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003ePF ≥ 0.99\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e1.2% + 0.005%\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e1.2% + 0.0075%\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e1.7% + 0.0075%\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e1.2% + 0.005%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eActive Energy E\u003csub\u003ea\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eApparent power S\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e0 ≤ PF ≤ 1\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e1.2% + 0.005%\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e1.2% + 0.0075%\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e1.7% + 0.0075%\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e1.2% + 0.005%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eApparent Energy E\u003csub\u003eap\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eReactive power Q\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e0 ≤ PF ≤ 1\u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"4\" class=\"v-top\"\u003e2.5% of measured apparent power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eReactive Energy E\u003csub\u003er\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003ePower Factor PF\u003c\/td\u003e\n\u003ctd rowspan=\"3\" class=\"v-top\"\u003e-\u003c\/td\u003e\n\u003ctd rowspan=\"3\" colspan=\"4\" class=\"v-top\"\u003e±0.025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eDisplacement Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eFactor DPF\/cosΦ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eAdditional uncertainty in% of range\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eV\u003csub\u003eP-N\u003c\/sub\u003e\u0026gt;250 V\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.015%\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.023%\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.023%\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.015%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\" class=\"v-top\"\u003e\n\u003csmall\u003e\u003csup\u003e1\u003c\/sup\u003e\u003c\/small\u003e\u003csmall\u003e In the range of 100 V … 500 V; also known as Udin\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e 0 °C … 45 °C: Intrinsic accuracy x 2, outside of 0 °C … 45 °C: Intrinsic accuracy x 3\u003cbr\u003e\u003csup\u003e3\u003c\/sup\u003e Consult operators manual for details\u003cbr\u003e\u003cbr\u003eReference conditions:\u003cbr\u003eEnvironmental: 23 °C ± 5 °C, instrument operating for at least 30 minutes, no external electrical\/magnetic field, RH \u0026lt;65 %\u003cbr\u003eInput conditions: Cosφ\/PF=1, Sinusoidal signal f=50 Hz\/60 Hz, power supply 120 V\/230 V ±10 %.\u003cbr\u003eCurrent and power specifications: Input voltage 1 ph: 120 V\/230 V or 3 ph wye\/delta: 230 V\/400 V\u003cbr\u003eInput current: I \u0026gt; 10 % of I range\u003cbr\u003ePrimary conductor of clamps or Rogowski coil in center position\u003cbr\u003eTemperature coefficient: Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eElectrical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003ePower Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003eVoltage range\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e100 V to 500 V using safety plug input when powering from the measurement circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003e100 V to 240 V MA-C8 and using standard power cord (IEC 60320 C7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eMaximum 50 VA (max. 15 VA when powered using MA-C8 adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eEfficiency\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e≥ 68.2% (in accordance with energy efficiency regulations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMaximum no-load consumption\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e\u0026lt; 0.3 W only when powered using IEC 60320 input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMains power frequency\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e50\/60 Hz ±15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eBattery\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eLi-ion 3.7 V, 9.25 Wh, customer-replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eOn-battery runtime\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eTypically 4 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eCharging time\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e\u0026lt; 6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eData Acquisition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eResolution\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e16-bit synchronous sampling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eSampling frequency\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e10.24 kHz at 50\/60 Hz, synchronized to mains frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eInput signal frequency\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e50\/60 Hz (42.5 to 69 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eCircuit types\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1-Φ, 1-Φ IT, split phase, 3-Φ delta, 3-Φ wye, 3-Φwye IT, 3-Φ wye balanced, 3-Φ Aron\/Blondel (2-element delta), 3-Φ delta open leg, currents only (load studies)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eData storage\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eInternal flash memory (not user replaceable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMemory size\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eTypical 20 logging sessions of 4 weeks with 1-minute intervals and 500 events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eBasic Interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMeasured parameters\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eVoltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eAveraging interval\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eUser selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eAveraging time min\/max values\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eVoltage, Current: Full cycle RMS updated every half cycle (URMS1\/2 according to IEC61000-4-30 Aux, Power: 200ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eDemand Interval (Energy Meter Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMeasured parameters\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eEnergy (Wh, varh, VAh), PF, maximum demand, cost of energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eInterval\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eUser selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003ePower Quality Measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMeasured parameter\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eVoltage, frequency, unbalance, voltage harmonics, THD V, current, harmonics, THD A, TDD, voltage interharmonics, TID V, current interharmonics, TID A, Flicker, Mains Signaling, under\/over deviation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eAveraging interval\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e10 min for all parameters\u003cbr\u003e2 hrs (long term Flicker PLT)\u003cbr\u003e150\/180 cycles (3 s) for harmonics (requires software license IEEE519\/REPORT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eIndividual harmonics\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e2nd to 50th harmonic\u003cbr\u003eGrouping according to IEC 61000-4-7 user configurable depending on application: Sub-grouped (harmonics + interharmonics), grouped or harmonic bins only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eInterharmonics\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1st to the 50th interharmonic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eTotal harmonic distortion\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eCalculated on 50 voltage harmonics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eEvents\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eVoltage: dips, swells, interruptions, current: inrush current\u003cbr\u003e1748: mains signaling, transients (low frequency)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" class=\"v-top\"\u003eTriggered recordings\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eRMS profile: Full cycle RMS updated every half cycle of voltage and current up to 11 s (URMS1\/2 according to IEC 61000-4-30)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eWaveform of voltage and current up to 200 ms, 10\/12 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMains signaling: 10\/12 cycle RMS recording of the configured frequencies up to 120s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eInrush\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eRMS profile based on 1\/2 cycle RMS steady state triggering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eFlicker\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eIn accordance with IEC 61000-4-15 and IEEE 1453\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMains signaling\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eTwo user defined frequencies up to 3 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003ePQ Health\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eSummarizes power quality measurements in one table. Detailed data available for each parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eEN 50160\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eCompliance with standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eProgrammable PQ limits\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eEnables user defined limits for local standards compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eStandards Compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003eHarmonics\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eIEC 61000-4-7: Class 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eIEEE 519 (short time and very short time harmonics)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003ePower quality\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eIEC 61000-4-30 Class A, IEC 62586-1, IEC 62586-2 (PQI-A-PI device)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003ePower\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eIEEE 1459\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003ePower quality compliance\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eEN 50160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" class=\"v-top\"\u003eSafety\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eGeneral: IEC 61010-1: Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMeasurement: IEC 61010-2-033: CAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003ePower Supply: Overvoltage Category IV, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eLi-ion Battery: IEC 62133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eInterfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eUSB-A\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eFile transfer via USB flash drive, firmware updates, max. supply current: 120 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eWi-Fi (free with product registration)\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eFile transfer and remote control via direct connection or Wi-Fi infrastructure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eBluetooth\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eRead auxiliary measurement data from Fluke Connect® 3000 series modules (requires supported USB to BLE or Wi-Fi\/BLE adapter, check for availability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eUSB-mini\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eData download device to PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eVoltage Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eNumber of inputs\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e4 (3 phases referenced to neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMaximum input voltage\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1000 Vrms, CF 1.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eInput impedance\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e10 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eBandwidth\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e42.5 Hz to 3.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eScaling\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1:1 and variable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMeasurement category\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1000 V CAT III\/600 V CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eCurrent Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eNumber of inputs\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e4 (3 phases and neutral), mode selected automatically for attached sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003eInput voltage\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eClamp input: 500 mVrms\/50 mVrms; CF 2.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eRogowski coil input: 150 mVrms\/15 mVrms at 50 Hz, 180 mVrms\/18 mVrms at 60 Hz; CF 4 all at nominal probe range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" class=\"v-top\"\u003eRange\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1 A to 150 A\/10 A to 1500 A with thin flexible current probe i17XX-flex1500 IP 24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003e3 A to 300 A\/30 A to 3000 A with thin flexible current probe i17XX-flex3000 IP 24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003e6 A to 600 A\/60 A to 6000 A with thin flexible current probe i17XX-flex6000 IP 36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003e40 mA to 4 A\/0.4 A to 40 A with 40 A clamp i40s-EL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eBandwidth\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e42.5 Hz - 3.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eScaling\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1:1 and variable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAuxiliary Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eNumber of inputs\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e2 (Analog with auxiliary adapter, or up to 2 BLE devices simultaneously)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eInput range\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0 to ± 10 V dc, or 0 to ± 1000 V dc (with optional adapter), 1 reading\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eScale factor\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eFormat: mx + b (gain and offset) user configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eDisplayed units\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eUser configurable (7 characters, for example, °C, psi, or m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWireless Bluetooth connection (check for availability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eNumber of inputs\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eSupported modules\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eFluke Connect® 3000 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eAcquisition\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1 reading\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e-25 °C to +50 °C (-13 °F to 122 °F)\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eWithout battery: -25 °C to +60 °C (-13 °F to 140 °F), with battery: -20 °C to +50 °C (−4 °F to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" class=\"v-top\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eIEC 60721-3-3: 3K6:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003e-25 °C to +30 °C (-13 °F to +86 °F): ≤ 100 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003e40 °C (104 °F): 55 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003e50 °C (122 °F): 35 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e2000 m (up to 4000 m derate to 1000 V CAT II\/600 V CAT III\/300 V CAT IV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eStorage altitude\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eIEC 60529: IP50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eIEC 60529: IP65 with IP65 rated voltage connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eVibration\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eIEC 60721-3-3 \/ 3M2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" class=\"v-top\"\u003eElectromagnetic compatibility (EMC)\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eEN 61326-1: Industrial CISPR 11: Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eIEC 61000-6-5 Power station environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eKorea (KCC): Class A Equipment (industrial broadcasting and communication equipment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eUSA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" class=\"v-top\"\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eTwo-years (battery not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories: one-year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration cycle: two-years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e23.0 cm x 18.0 cm x 5.4 cm (9.1 in x 7.1 in x 2.1 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eInstrument: 1 kg (2.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eTamper protection\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eAccept securing cables (max. Φ 6mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e\n\u003csup\u003e1\u003c\/sup\u003eWarm up the product to -10 °C (+14 °F) before you power the unit on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ei17XX-FLEX1.5KIP Flexible Current Probe Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1 to 150 A ac\/10 to 1500 A ac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eProbe cable length\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e610 mm (24 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eProbe cable diameter\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e7.5 mm (0.3 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e170 g (0.38 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMinimum bending radius\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e38 mm (1.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eNondestructive current\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e100 kA (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eTemperature coefficient over\u003cbr\u003eoperating temperature range\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.05 % of reading\/°C (0.028 % of reading\/°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eWorking voltage\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1000 V CAT III, 600 V CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eOutput cable length\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e2.0 m (6.5 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eProbe cable material\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eTPR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e115 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504305516629,"sku":"Fluke 1742\/15\/INTL","price":2101044.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/FLUKE-1742-15-INTL-POWER-QUALITY-LOGGER-W60CM-1500A-IFLEX-INTL.jpg?v=1612946203","url":"https:\/\/www.gilautomation.com\/en-ao\/products\/fluke-1742-15-intl-power-quality-logger-with-60cm-1500a-iflex-intl-version","provider":"gilautomation","version":"1.0","type":"link"}