{"product_id":"fluke-28-ii-ex-intrinsically-safe-true-rms-digital-multimeter","title":"Fluke 28 II Ex Intrinsically safe true-rms digital multimeter","description":"\u003ch2\u003eProduct overview: Fluke 28 II Ex Intrinsically Safe True RMS Digital Multimeter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003eNow there's an intrinsically safe digital multimeter (DMM) you can use in a wide range of hazardous settings. Whether you work in petroleum, chemical, or pharmaceutical environments, the 28 II Ex gives high-end test and troubleshooting power you need is packed into the most rugged intrinsically safe (IS) DMM Fluke has ever built: drop-proof, waterproof, dust-proof (IP67). The 28 II Ex meets the following certifications:\u003c\/p\u003e\n\u003cdiv class=\"super-custom\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eIECEx (International)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEx ia IIC T4 Gb\u003c\/li\u003e\n\u003cli\u003eEx ia I Ma\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cimg alt=\"IECEx\" class=\" lazyloaded\" height=\"70\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/iecex_v2.jpg\" title=\"IECEx\" width=\"70\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eATEX (Europe)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eII 2G Ex ia IIC T4 Gb\u003c\/li\u003e\n\u003cli\u003eI M1 Ex ia I Ma\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cimg alt=\"ATEX\" class=\" lazyloaded\" height=\"70\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/atex_v2.jpg\" title=\"ATEX\" width=\"70\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eNEC \/ CEC (North America)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eClass I, Division 1, Groups A,B,C,D T4\u003c\/li\u003e\n\u003cli\u003eClass I, Zone 1, AEx ia IIC T4\u003c\/li\u003e\n\u003cli\u003eEx ia IIC T4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cimg alt=\"NEC \/ CEC\" class=\" lazyloaded\" height=\"70\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/etl_v2.jpg\" title=\"NEC \/ CEC\" width=\"70\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003ePCEC (China)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEx ia IIC T4 Gb\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cimg alt=\"PCEC\" class=\" lazyloaded\" height=\"70\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/pcec_v2.jpg\" title=\"PCEC\" width=\"70\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSimtars (Australia)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEx ia I Ma\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cimg alt=\"Simtars\" class=\" lazyloaded\" height=\"70\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/simtars_v2.jpg\" title=\"Simtars\" width=\"70\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eIEx (Brazil)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEx ia IIC T4 Gb\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cimg alt=\"IEx\" class=\" lazyloaded\" height=\"70\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/inmetro-iex_v2.jpg\" title=\"IEx\" width=\"70\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eEAC (Russia)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1Ex ia IIC T4 Gb X\u003c\/li\u003e\n\u003cli\u003ePO Ex ia I Ma X\u003c\/li\u003e\n\u003cli\u003eIP6X\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cimg alt=\"EAC\" class=\" lazyloaded\" height=\"70\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/eac_v2.jpg\" title=\"EAC\" width=\"70\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003eAll the measurement functions of our most popular industrial DMMs\u003c\/h2\u003e\n\u003cp\u003eOne tool equips you with all the testing and troubleshooting power you need wherever you go––inside or outside ATEX zones 1 or 2,. No need to carry different meters for different areas, or worry about crossing through an Ex-required zone with a non-Ex rated instrument.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e4-1\/2 digit mode for precise measurements (20 000 counts)\u003c\/li\u003e\n\u003cli\u003eTrue-rms ac voltage and current for accurate measurement on nonlinear signals\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000 V and 10A AC and DC (note that Ex zones require reduced measurements)\u003c\/li\u003e\n\u003cli\u003eLow pass filter ensures accurate voltage and frequency measurements on variable speed motor drives (VSDs)\u003c\/li\u003e\n\u003cli\u003eFrequency to 200 kHz and % duty cycle to help you diagnose VSDs and switching power supplies\u003c\/li\u003e\n\u003cli\u003eResistance, continuity and diode test\u003c\/li\u003e\n\u003cli\u003e10 000 μF capacitance range for components and motor caps\u003c\/li\u003e\n\u003cli\u003eConductance measurements for high resistance or leakage tests\u003c\/li\u003e\n\u003cli\u003eMin\/Max-Average and Peak capture to record transients and variations automatically\u003c\/li\u003e\n\u003cli\u003eRelative mode to remove test lead interference on resistance measurements\u003c\/li\u003e\n\u003cli\u003eAuto and manual ranging for maximum flexibility\u003c\/li\u003e\n\u003cli\u003eInput Alert protects you by chirping and flashing “Lead when leads are plugged into the wrong inputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEasy to use\u003c\/h2\u003e\n\u003cp\u003eImportant extras keep you productive all day long in less than optimal conditions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBacklit keypad buttons provide extra visibility in poorly lit areas, even when you’re wearing full PPE\u003c\/li\u003e\n\u003cli\u003eLarge display digits and 2-level bright white backlight also increases visibility\u003c\/li\u003e\n\u003cli\u003eLong battery life – 400 hours typical without backlight (Alkaline)\u003c\/li\u003e\n\u003cli\u003eOptional magnetic hanger for easy setup and viewing while freeing your hands for other tasks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEasy to service in the field\u003c\/h2\u003e\n\u003cp\u003eAccess to the separate battery compartment makes it easy to change batteries or fuses without jeopardizing instrument calibration.\u003c\/p\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications: Fluke 28 II Ex Intrinsically Safe True RMS Digital Multimeter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAccuracy Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eAccuracy specifications are shown as ±(% of reading + number of digits)\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.05% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.7% + 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC current\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 μA to 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2% + 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC current\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 μA to 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω to 50 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eConductance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e60.00 nS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDiode test\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(2.0% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDuty cycle\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0% to 99.9%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eWithin ±(0.2% per kHz + 0.1%) for rise times \u0026lt;1 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e10 nF to 9999 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 Hz to 199.99 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.005% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-200°C to +1090°C (-328°F to +1994°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1% + 10)°C [±(1% + 10)°F]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay counts\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6000 counts\/19,999 counts in high-resolution mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak capture\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRecord transients up to 250 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin\/Max\/Avg recording\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDisplay signals up to approximately 100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"3\"\u003eAccuracy specifications are shown as ±(% of reading + number of digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSafety Certifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eATEX\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e{Ex} II 2G Ex ia IIC T4 Gb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e{Ex} I M1 Ex ia I Ma\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNEC-500\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eClass I, Div 1, Groups A-D, 130°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eIECEx\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEx ia IIC T4 Gb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eEx ia I Ma\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eGOST R Ex\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1Ex ia IIC T4 Gb X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ePO Ex ia I Ma X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eIP6X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003ePower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eThree AAA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eBattery life: 400 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eLCD, with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRubber holster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThree years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize with holster (H x W x L)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6.4 x 10.0 x 19.8 cm (2.5 x 3.9 x 7.8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight with holster\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e700 g (1.54 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434178654293,"sku":"Fluke 28 II Ex","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/13_2cf27556-dd2f-4980-b98a-33a071d4a109.jpg?v=1592229565","url":"https:\/\/www.gilautomation.com\/en-ao\/products\/fluke-28-ii-ex-intrinsically-safe-true-rms-digital-multimeter","provider":"gilautomation","version":"1.0","type":"link"}