{"product_id":"fluke-374-600a-trms-clamp-meter","title":"Fluke 374 600A TRMS Clampmeter","description":"\u003cp\u003eFLUKE-374\/E FLUKE-374\/E,600A TRMS AC\/DC CLAMP\u003c\/p\u003e\n\u003ch2\u003eProduct overview: Fluke 374 True RMS AC\/DC Clamp Meter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cstrong\u003eBe ready for anything\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 374 True RMS Clamp Meter can read up to 600 V and 600 A in both AC and DC modes. Additionally, the 374 is compatible with the new iFlex flexible current probe (sold separately), which increases the measurement range to 2500 A AC and provides increased display flexibility, and improved wire access.\u003c\/p\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cul\u003e\n\u003cli\u003eiFlex flexible current probe (sold separately) expands the measurement range to 2500 A AC while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V, CAT III 1000 V\u003c\/li\u003e\n\u003cli\u003ePropietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it\u003c\/li\u003e\n\u003cli\u003eErgonomic design fits in your hand and can be used while wearing personal protective equipment\u003c\/li\u003e\n\u003cli\u003eLarge, easy to read backlight display automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 374 True RMS AC\/DC Clamp Meter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eElectrical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eAC Current via Jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e374 and 375\u003cbr\u003e376\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600.0 A\u003cbr\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2% ± 5 digits (10-100 Hz)\u003cbr\u003e2.5% ± 5 digits (100-500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eCrest Factor (50\/60 Hz)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 @ 500 A (375 and 376 only)\u003cbr\u003e2.5 @ 600 A\u003cbr\u003e1.42 @1000 A (376 only)\u003cbr\u003eAdd 2% for C.F. \u0026gt; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eAC Current via Flexible Current Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e374 and 375\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 A (≤ 600 A)\u003cbr\u003e1 A (≤ 2500 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003e376\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 A (≤ 999.9 A)\u003cbr\u003e1 A (≤ 2500 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3% ±5 digits (5 – 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eCrest Factor (50\/60Hz)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3.0 at 1100 A (375 and 376 only)\u003cbr\u003e2.5 at 1400 A\u003cbr\u003e1.42 at 2500 A\u003cbr\u003eAdd 2% for C.F. \u0026gt; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eDistance from Optimum\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei2500-10 Flex\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei2500-18 Flex\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eError\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\u003cimg alt=\"Flexible current probe\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/37x_position_sens_100x181.png\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eA\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 in (12.7 mm)\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd\u003e± 0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eB\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 in (20.3 mm)\u003c\/td\u003e\n\u003ctd\u003e2.0 in (50.8 mm)\u003c\/td\u003e\n\u003ctd\u003e± 1.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eC\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd\u003e2.5 in (63.5 mm)\u003c\/td\u003e\n\u003ctd\u003e± 2.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"5\"\u003eMeasurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eDC Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e374 and 375\u003cbr\u003e376\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600.0 A\u003cbr\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eAC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e374 and 375\u003cbr\u003e376\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600.0 V\u003cbr\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e374 and 375\u003cbr\u003e376\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 V\u003cbr\u003e0.1 V (≤ 600.0 V)\u003cbr\u003e1 V (≤ 1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5% ± 5 digits (20 – 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eDC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e374 and 375\u003cbr\u003e376\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600.0 V\u003cbr\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e374 and 375\u003cbr\u003e376\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 V\u003cbr\u003e0.1 V (≤ 600.0 V)\u003cbr\u003e1 V (≤ 1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003emV dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e375 and 376\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eFrequency via Jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e375 and 376\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.0 - 500.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" rowspan=\"3\"\u003eTrigger Level\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5 – 10 Hz, ≥10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e10 – 100 Hz, ≥5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e100 – 500 Hz, ≥10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eFrequency via Flexible Current Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e375 and 376\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.0 - 500.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" rowspan=\"3\"\u003eTrigger Level\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5 – 20 Hz, ≥ 25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e20 – 100 Hz, ≥ 20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e100 – 500 Hz, ≥ 25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eResistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRange\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e374\u003cbr\u003e375 and 376\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6000 Ω\u003cbr\u003e60 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"2\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e374\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 Ω (≤ 600 Ω)\u003cbr\u003e1 Ω (≤ 6000 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003e375 and 376\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 Ω (≤ 600 Ω)\u003cbr\u003e1 Ω (≤ 6000 Ω)\u003cbr\u003e10 Ω (≤ 60 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eCapacitance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 μF (≤ 100 μF)\u003cbr\u003e1 μ F (≤ 1000 μF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1% ± 4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eMechanical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e246 mm x 83 m x 43 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e388 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eJaw Opening\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eFlexible Current Probe Diameter\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e7.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eFlexible Current Probe Cable Length\u003cbr\u003e(head to electronics connector)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.8 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10°C – +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eStorage Temp\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C – +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNon condensing (\u0026lt; 10 –°C)\u003cbr\u003e≤ 90% RH (at 10°C – 30°C)\u003cbr\u003e≤ 75% RH (at 30°C – 40°C)\u003cbr\u003e≤ 45% RH (at 40°C – 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eStorage Altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12,000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eEMC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN 61326-1:2006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eTemperature Coefficients\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAdd 0.1 x specified accuracy for each\u003cbr\u003edegree C above 28°C or below 18°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eSafety Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCAN\/CSA-C22.2 No. 61010-1-04\u003cbr\u003eANSI\/UL 61010-1:2004\u003cbr\u003eANSI\/ISA-61010-1 (82.02.01):2004\u003cbr\u003eEN\/IEC 61010-1:2001 to\u003cbr\u003e1000V Measurement Category (CAT) III\u003cbr\u003e600V Measurement Category (CAT) IV\u003cbr\u003ePollution Degree 2\u003cbr\u003eEN\/IEC 61010-2-032:2002\u003cbr\u003eEN\/IEC 61010-031:2002+A1:2008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd class=\"certifications\" colspan=\"2\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434181800021,"sku":"Fluke 374","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/6_4655a4d9-95e8-47c3-a29d-c61d5e559624.jpg?v=1592306140","url":"https:\/\/www.gilautomation.com\/en-ao\/products\/fluke-374-600a-trms-clamp-meter","provider":"gilautomation","version":"1.0","type":"link"}