{"product_id":"fluke-700g05-pressure-gaugse-2bar","title":"Fluke  700G05 Pressure Gauge, 2 bar","description":"\u003ch2\u003eProduct overview: Fluke 700G Pressure Gauge Calibrator\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003eDesigned for field pressure calibration, the Fluke 700G Series Pressure Gauge Calibrators give you the performance and durability that you have come to expect in Fluke pressure calibration products while being simple and easy-to-use. Whether you’re looking to connect to either a hydraulic or pneumatic test pump this series are designed to be a complete calibration solution with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e23 pressure gauges\u003c\/li\u003e\n\u003cli\u003eranging ±10 inH2O\/20 mbar to 10,000 psi\/690 bar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWith a standard accuracy of 0.05% of full scale and reference class gauges with accuracies of 0.04% you’re sure to find a gauge that’s the perfect fit for your application.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement and data logging\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke-700G series gauges and pump kits are designed for the pressure testing professional working on process pressure instrumentation. The pressure ranges of the 700G series gauges cover the ranges needed for process pressure calibration needs including Gage pressures +\/- 10 inH20 (+\/- 25 mbar) to 10,000 psi (0-690 bar), Absolute pressures from 0 to 15 psia (0-1 bar) to 0-300 psi (0-20 bar) and reference class gauges from 0 to 30 PSI (0-2 bar) to 10,000 psi (0-690 bar).\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStandard accuracy to 0.05 % of full scale\u003c\/li\u003e\n\u003cli\u003eReference class gauges deliver 0.04% of reading measurement accuracy\u003c\/li\u003e\n\u003cli\u003eLog more than 8,493 pressure measurements to memory and uploads to a PC (with 700G\/TRACK software)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRugged design with intrinsically safe certification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRugged sealed IP-67 enclosure with included protective holster\u003c\/li\u003e\n\u003cli\u003eAllows you to work safely in classified areas known to include explosive gasses:\u003cspan\u003e \u003c\/span\u003e\n\u003cul\u003e\n\u003cli\u003eCSA: Class 1, Div2, Groups A-D rating\u003c\/li\u003e\n\u003cli\u003eATEX:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eStandard 3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e“No tools required” connections\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePressure gauges are the easiest to use of all pressure calibration tools. Power them up, connect to the pressure device you want to measure and see your measurement, it’s that easy. When used with a Fluke-700PTPK pneumatic or 700HTPK hydraulic pump kit the 700G becomes a complete pressure sourcing and measurement solution. The 700PTPK2 and 700HTPK2 premium pump kits offer easy connectivity to the gauge and device under test providing “no tools required” connections.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete pressure calibration solution when gauges are paired with special pump kits\n\u003cul\u003e\n\u003cli\u003eCalibrate to 600 psi (20 bar) with the 700PTPK or 700PTPK2 pneumatic pump kit.\u003c\/li\u003e\n\u003cli\u003eCalibrate to 10,000 psi (690 bar) with the 700HTPK or 700HTPK2 hydraulic pump kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 700G Pressure Gauge Calibrator\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003ctable class=\"not-trash\"\u003e\n\u003ccaption\u003e700R Ranges: Temperature Compensation 0 e °C to 50 °C (32 °F to 122 °F) to rated accuracy.\u003cbr\u003eFor temperatures from -10 °C to 0 °C and 50 °C to 55 °C, add .005% FS\/ °C\u003c\/caption\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003cth\u003eBurst Pressure\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G01\u003c\/td\u003e\n\u003ctd\u003e-10 to +10 inH\u003csub\u003e2\u003c\/sub\u003eO\u003cbr\u003e-20 mbar to 20 mbar\u003c\/td\u003e\n\u003ctd\u003e0.001 inH\u003csub\u003e2\u003c\/sub\u003eO,\u003cbr\u003e0.001 mbar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.1% of range,\u003cbr\u003eVacuum ±0.1% of range\u003c\/td\u003e\n\u003ctd\u003e3 psi,\u003cbr\u003e210 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G02\u003c\/td\u003e\n\u003ctd\u003e-1 to +1 psi,\u003cbr\u003e-70 mbar to 70 mbar\u003c\/td\u003e\n\u003ctd\u003e0.0001 psi,\u003cbr\u003e0.001 mbar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.1% of range,\u003cbr\u003eVacuum ±0.1% of range\u003c\/td\u003e\n\u003ctd\u003e5 psi,\u003cbr\u003e350 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G04\u003c\/td\u003e\n\u003ctd\u003e-14 to 15 psi,\u003cbr\u003e-0.97 to 1 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e60 psi,\u003cbr\u003e4 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G05\u003c\/td\u003e\n\u003ctd\u003e-14 to 30 psi,\u003cbr\u003e-0.97 to 2 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e120 psi,\u003cbr\u003e8 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G06\u003c\/td\u003e\n\u003ctd\u003e-12 to 100 psi,\u003cbr\u003e-0.83 to 6.9 bar\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e400 psi,\u003cbr\u003e26 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G27\u003c\/td\u003e\n\u003ctd\u003e-12 to 300 psi,\u003cbr\u003e-0.83 to 20 bar\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e1200 psi,\u003cbr\u003e80 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G07\u003c\/td\u003e\n\u003ctd\u003e-12 to 500 psi,\u003cbr\u003e-0.83 to 34 bar\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e2000 psi,\u003cbr\u003e138 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G08\u003c\/td\u003e\n\u003ctd\u003e-14 to 1000 psi,\u003cbr\u003e-0.97 to 69 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e4000 psi,\u003cbr\u003e266 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G10\u003c\/td\u003e\n\u003ctd\u003e-14 to 2000 psi,\u003cbr\u003e-.97 bar to 140 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e8000 psi,\u003cbr\u003e550 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G29\u003c\/td\u003e\n\u003ctd\u003e-14 to 3000 psi,\u003cbr\u003e-0.97 to 200 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e10000 psi,\u003cbr\u003e690 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G30\u003c\/td\u003e\n\u003ctd\u003e-14 to 5000 psi,\u003cbr\u003e-0.97 to 340 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e10000 psi,\u003cbr\u003e690 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700G31\u003c\/td\u003e\n\u003ctd\u003e-14 to 10000 psi,\u003cbr\u003e-0.97 to 690 bar\u003c\/td\u003e\n\u003ctd\u003e1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure ±0.05% FS\u003cbr\u003eVacuum ±0.1% FS\u003c\/td\u003e\n\u003ctd\u003e20000 psi,\u003cbr\u003e1035 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700GA4\u003c\/td\u003e\n\u003ctd\u003e0 to 15 psia,\u003cbr\u003e0 to 1 bar absolute\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e±0.05% of range\u003c\/td\u003e\n\u003ctd\u003e60 psi,\u003cbr\u003e4 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700GA5\u003c\/td\u003e\n\u003ctd\u003e0 to 30 psia\u003cbr\u003e0 to 2 bar absolute\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e±0.05% of range\u003c\/td\u003e\n\u003ctd\u003e120 psi,\u003cbr\u003e8 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700GA6\u003c\/td\u003e\n\u003ctd\u003e0 to 100 psia,\u003cbr\u003e0 to 6.9 bar absolute\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e±0.05% of range\u003c\/td\u003e\n\u003ctd\u003e400 psi,\u003cbr\u003e27 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700GA27\u003c\/td\u003e\n\u003ctd\u003e0 to 300 psia,\u003cbr\u003e0 to 20 bar absolute\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003e±0.05% of range\u003c\/td\u003e\n\u003ctd\u003e1200 psi,\u003cbr\u003e80 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700RG05\u003c\/td\u003e\n\u003ctd\u003e-14 to +30 psi,\u003cbr\u003e-0.97 to +2 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure,\u003cbr\u003e±0.04% of reading +.01% of range,\u003cbr\u003eVacuum ±0.05% of range\u003c\/td\u003e\n\u003ctd\u003e90 psi,\u003cbr\u003e6 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700RG06\u003c\/td\u003e\n\u003ctd\u003e-12 to 100 psi,\u003cbr\u003e-0.83 to 6.9 bar\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure,\u003cbr\u003e±0.04% of reading +.01% of range,\u003cbr\u003eVacuum ±0.1% of range\u003c\/td\u003e\n\u003ctd\u003e400 psi,\u003cbr\u003e27 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700RG07\u003c\/td\u003e\n\u003ctd\u003e-12 to 500 psi,\u003cbr\u003e-0.83 to 34\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure,\u003cbr\u003e±0.04% of reading +.01% of range,\u003cbr\u003eVacuum ±0.1% of range\u003c\/td\u003e\n\u003ctd\u003e2000 psi,\u003cbr\u003e138 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700RG08\u003c\/td\u003e\n\u003ctd\u003e-14 to 1000 psi,\u003cbr\u003e-0.97 to 69 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure,\u003cbr\u003e±0.04% of reading +.01% of range,\u003cbr\u003eVacuum ±0.1% of range\u003c\/td\u003e\n\u003ctd\u003e4000 psi,\u003cbr\u003e275 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700RG29\u003c\/td\u003e\n\u003ctd\u003e-14 to 3000 psi,\u003cbr\u003e-0.97 to 200 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure,\u003cbr\u003e±0.04% of reading +.01% of range,\u003cbr\u003eVacuum ±0.1% of range\u003c\/td\u003e\n\u003ctd\u003e10000 psi,\u003cbr\u003e690 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700RG30\u003c\/td\u003e\n\u003ctd\u003e-14 to 5000 psi,\u003cbr\u003e-0.97 to 340 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure,\u003cbr\u003e±0.04% of reading +.01% of range,\u003cbr\u003eVacuum ±0.1% of range\u003c\/td\u003e\n\u003ctd\u003e15000 psi,\u003cbr\u003e1035 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke-700RG31\u003c\/td\u003e\n\u003ctd\u003e-14 to 10000 psi,\u003cbr\u003e-0.97 to 690 bar\u003c\/td\u003e\n\u003ctd\u003e1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003ePositive pressure,\u003cbr\u003e±0.04% of reading +.01% of range,\u003cbr\u003eVacuum ±0.1% of range\u003c\/td\u003e\n\u003ctd\u003e20000 psi,\u003cbr\u003e1380 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"not-trash\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMedia compatibility\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e10 inH\u003csub\u003e2\u003c\/sub\u003eO, 1, 15, 30 psi: any clean dry non-corrosive gas\u003c\/li\u003e\n\u003cli\u003e100, 300, 500, 1000 psi: any liquids or gases compatible with 316 stainless steel and above 1000 psi: any non-flammable, non-toxic, non-explosive, non-oxidizing liquid or gas compatible with 316 stainless steel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"not-trash\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eMechanical Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e12.7 x 11.4 x 3.7 cm (5 x 4.5 x 1.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure connection\u003c\/td\u003e\n\u003ctd\u003e¼ in NPT Male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\/Weight\u003c\/td\u003e\n\u003ctd\u003eCast ZNAL 0.56 kg (1.22 lb) with holster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e5-1\/2 digits, 16.53 mm (0.65 in) high 20-segment bar graph, 0 to 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eThree (3) AA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e1,500 hours without backlight (continuous on), 2,000 hours at slow sample rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504315576405,"sku":"Fluke 700G05","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/fluke_700g_precision_pressure_test_gauge_10000_psig_57c6dbc7-3c43-4b36-af62-32f2f354fa03.jpg?v=1597669072","url":"https:\/\/www.gilautomation.com\/en-ao\/products\/fluke-700g05-pressure-gaugse-2bar","provider":"gilautomation","version":"1.0","type":"link"}