{"product_id":"fluke-710ma-loop-valve-tester-with-hart","title":"Fluke 710mA Loop, Valve Tester, with HART","description":"\u003ch2 data-mce-fragment=\"1\"\u003eProduct overview: Fluke 710 mA Loop Valve Tester\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\" data-mce-fragment=\"1\"\u003e\n\u003cdiv id=\"product-overview\" data-mce-fragment=\"1\"\u003e\n\u003cdiv id=\"overview_content\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSmart Control Valve Testing is now easier than ever\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Fluke 710 Valve Testing Loop Calibrator is designed to enable users to perform quick, easy tests on HART smart control valves. Featuring built-in test procedures and an intuitive user interface, the 710 allows users to quickly and easily perform valve tests, while the valve test quick-check results provide at-a-glance diagnostics help you make maintenance decisions faster than ever. The valve health quick-check results let you know whether your valve is in good, marginal or in bad operating condition so you can quickly decide whether additional maintenance is necessary.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eValve testing and HART communication in a precision loop calibrator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWith the 710 Valve Testing Loop Calibrator’s built in HART communication function, users can source a 4-20 mA signal to cause the smart control valve to move, while simultaneously interpreting the valve’s HART feedback signal to determine whether the valve is moving to the expected position. In addition to positional information, the measured pressure delivered from the valve’s internal I\/P (which moves the valve) can be determined through the HART communication protocol.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe 710 has built-in test procedures that automatically increase and change the mA signal while monitoring the HART position and pressure feedback from the control valve, giving you a better overall picture of valve health at the simple push of a button.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePre-configured valve tests, at-a-glance answers\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eValve test routines built into the 710 include:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eManual testing; manually change the mA signal and view the HART position and pressure variable information\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFull range ramping of the mA signal from 4 to 20 to 4 mA while recording the 0-100-0% position, or the pressures applied that move the valve from 0-100-0%\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eStepping the mA signal on the input to the valve in steps and evaluating the valves response to the mA input changes\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSpeed tests to determine how fast the valve can open or close\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eBump and partial stroke tests that help test valves over a portion of their range so they can be tested in a live process\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eValveTrack™ Software enables further analysis and trending\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eValve tests that are logged and recorded to memory in the 710 are available to upload to included\u003cspan data-mce-fragment=\"1\"\u003e ValveTrack™ analysis software\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eValveTrack™ software enables you to:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUpload, print and plot logged valve tests taken in the field\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCompare previous uploaded tests to recent tests\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eView valve test history by HART Tag ID\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eExport valve test data to CSV for additional analysis in Microsoft Excel®\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSaving time, getting answers\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eIn addition, the 710 offers:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLogging of HART data in the field. Once recorded by the 710 in the field, the ValveTrack™ software can upload the HART configuration of up to (20) HART devices in your plant and output data in either (.csv) or (.txt) format.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eData logged mA loop measurements and HART data can be recorded from a particular transmitter for troubleshooting and loop tuning. The data log feature offers selectable capture with recording intervals of 1 to 60 seconds and a logging capacity of 4910 records or 99 individual sessions. Each record contains the mA measurement and all four process variables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eProduct Highlights\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eValve test procedures that deliver Good, Marginal or Bad assessment of a control valve\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eGeneric HART communication\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eBest-in-class mA accuracy at 0.01 % measurement or source value\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCompact rugged design\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIntuitive user interface with Quick-Set knob for fast setup, easy to use\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e24 V DC loop power with mA measure mode (-25 % to 125 %)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eResolution of 1 μA on mA ranges and 1 mV on voltages ranges\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eBuilt in selectable 250 Ω resistor for HART communications\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSimple two wire connection for all measurements\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAuto shutdown to conserve battery life\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVariable step and ramp time in seconds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eHART communication\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Fluke 710 offers a built-in HART modem to communicate the following HART commands:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRead sensor PV information\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRead PV output information\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRead and write PV unit type, tag ID name, descriptor, and message\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRead and write PV ranges (upper and lower)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEnter\/exit fixed current mode\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSet zero offset\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTrim DAC zero (mA output 4 mA)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTrim DAC gain (mA output 20 mA)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eHART Commands for Valves\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe 710 includes these unique HART commands to support control valves:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAuto-trim of valve controller\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eIn addition, the Fluke 710 offers:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLogging of HART data in the field. Once recorded by the 710 in the field, the ValveTrack™ software can upload the HART configuration of up to 20 HART devices in your plant and output data in either .csv or .txt format\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eData-logged mA loop measurements and HART data can be recorded from a particular transmitter for troubleshooting and loop tuning. The data log feature offers selectable capture with recording intervals of 1 to 6 seconds and a logging capacity of 4910 records or 99 individual sessions. Each record contains the mA measurement and all four process variables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv aria-expanded=\"true\" data-readmore=\"\" id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003eKey valve testing functions include pre-configured valve signature test, speed test, step test, manual test, and bump\/partial stroke test\u003c\/li\u003e\n\u003cli\u003eKey mA loop calibrator functions include mA source, mA simulate, mA read, mA read\/loop power, and volts read\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eValveTrack™ Software \u003c\/span\u003eenables upload to a PC for further in-depth analysis of valve measurements that are logged and recorded to memory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 710 mA Loop Valve Tester\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 510px;\"\u003eDetailed Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eFunctions\u003c\/td\u003e\n\u003ctd style=\"width: 348.333px;\"\u003emA source, mA simulate, mA read, mA read\/loop power, and volts read.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eRanges\u003c\/td\u003e\n\u003ctd style=\"width: 348.333px;\"\u003emA (0 to 24 mA) and Volts (0 to 30 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 348.333px;\"\u003e1 µA on mA ranges and 1 mV on voltage range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 348.333px;\"\u003e0.01% ± 2 counts, all ranges (@ 23 °C ± 5 °C [73.4 °F ± 41 °F])\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eOperating temperature range\u003c\/td\u003e\n\u003ctd style=\"width: 348.333px;\"\u003e-10°C to 55°C (14°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eHumidity range\u003c\/td\u003e\n\u003ctd style=\"width: 348.333px;\"\u003e10 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eStability\u003c\/td\u003e\n\u003ctd style=\"width: 348.333px;\"\u003e20 ppm of F.S. \/°C from -10°C to 18°C and 28°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"width: 348.333px;\"\u003e128 x 64 pixels, LCD Graphic w\/backlight, .34 high digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003ePower\u003c\/td\u003e\n\u003ctd style=\"width: 348.333px;\"\u003e6 AAA alkaline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eBattery life\u003c\/td\u003e\n\u003ctd style=\"width: 348.333px;\"\u003e40 hours continuous use (measure mode using)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eLoop compliance voltage\u003c\/td\u003e\n\u003ctd style=\"width: 348.333px;\"\u003e24 V DC @ 20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eOver-voltage protection\u003c\/td\u003e\n\u003ctd style=\"width: 348.333px;\"\u003e240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eOverload current protection\u003c\/td\u003e\n\u003ctd style=\"width: 348.333px;\"\u003e28 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eEMC\u003c\/td\u003e\n\u003ctd style=\"width: 348.333px;\"\u003eEN61326 Annex A (Portable Instruments)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eDimensions (L x W x D)\u003c\/td\u003e\n\u003ctd style=\"width: 348.333px;\"\u003e15 x 9 x 3 cm (6 x 3.6 x 1.3 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 348.333px;\"\u003e0.3 kg (9.5 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eIncluded accessories\u003c\/td\u003e\n\u003ctd style=\"width: 348.333px;\"\u003eTraceable calibration certificate with data, batteries, test leads, USB upload cable and safety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"width: 348.333px;\"\u003eThree years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504312397909,"sku":"Fluke 710","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/61eycLNI5mL._SL1500.jpg?v=1600852948","url":"https:\/\/www.gilautomation.com\/en-ao\/products\/fluke-710ma-loop-valve-tester-with-hart","provider":"gilautomation","version":"1.0","type":"link"}