{"product_id":"fluke-805-fc-vibrationmeter-with-fluke-connect","title":"Fluke 805 FC Vibration Meter with Fluke Connect","description":"\u003ch2\u003eProduct overview: Fluke 805 FC Vibration Meter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cstrong\u003eThe reliable, repeatable, accurate way to check bearings and machine health\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMake go or no-go maintenance decisions with confidence. The Fluke 805 FC Vibration Meter is the most reliable vibration screening device available for frontline mechanical troubleshooting teams that need repeatable, severity-scaled readings of overall vibration, bearing health and machine health.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eManage and monitor workflow for better maintenance results\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUsing the Fluke Connect Mobile App it’s now easier than ever to manage your vibration screening workflow. Integrated machine profile functionality allows you to setup machine profiles using the app and then push them directly to your 805 FC Vibration Meter. Users can then use the list of machine profiles to create work orders, and develop route based maintenance schedules which can be dynamically sent to technicians in field, helping to ensure the proper focus on critical assets. Once a machine is tested, the 805 FC communicates the results directly to the app and associates them with the proper profile and route. This data can easily be shared between teams, so you can make better maintenance decisions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReliable, repeatable, accurate device for checking bearings and overall vibration\u003c\/li\u003e\n\u003cli\u003eFeatures innovative sensor design that minimizes measurement variations caused by device angle or contact pressure\u003c\/li\u003e\n\u003cli\u003eProvides consistent data quality at both low and high frequency ranges\u003c\/li\u003e\n\u003cli\u003eOffers four-level severity scale to assess urgency of problems and bearing condition\u003c\/li\u003e\n\u003cli\u003eAllows you to export data via USB or wirelessly, through the Fluke Connect® mobile app\u003c\/li\u003e\n\u003cli\u003eCompatible with Fluke Connect® Mobile App that can transmit measurements to your smartphone to be shared in real time\u003c\/li\u003e\n\u003cli\u003eEnables you to get authorization to take next steps in an instant if machine health is at risk via Fluke Connect™ mobile app*\u003c\/li\u003e\n\u003cli\u003eAllows you to view trending in Microsoft® Excel using pre-built templates\u003c\/li\u003e\n\u003cli\u003eMeasures overall vibration (10 Hz to 1,000 Hz) for acceleration, velocity, and displacement units of measurement for a wide variety of machines\u003c\/li\u003e\n\u003cli\u003eProvides Crest Factor+ technology for reliable bearing assessment using direct sensor tip measurements between 4,000 Hz and 20,000 Hz\u003c\/li\u003e\n\u003cli\u003eCompares vibration levels with ISO-10816 severity scales and stores results to the Fluke Connect Cloud\u003c\/li\u003e\n\u003cli\u003eFeatures colored lighting system (green, red) and on-screen comments to indicate how much pressure needs to be applied to take measurements\u003c\/li\u003e\n\u003cli\u003eMeasures temperature with Spot IR Sensor to increase diagnostic capabilities\u003c\/li\u003e\n\u003cli\u003eHolds and saves up to 3,500 measurements in on-board memory\u003c\/li\u003e\n\u003cli\u003eExternal accelerometer (optional) support for hard to reach locations\u003c\/li\u003e\n\u003cli\u003eFeatures built-in flashlight for viewing measurement locations in dark areas\u003c\/li\u003e\n\u003cli\u003eProvides large high-resolution display for easy navigation and viewing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv aria-expanded=\"true\" data-readmore=\"\" id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEASY SETUP\u003c\/strong\u003e\u003cbr\u003eQuickly create asset list and work order on your PC, setup machine profiles using Fluke Connect App on your smart device, push routes to your 805 FC for your technicians in the field.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCONSISTENT DATA QUALITY\u003c\/strong\u003e\u003cbr\u003eTake accurate, reliable measurements at both low and high frequency ranges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMOBILE DATA ACCESS\u003c\/strong\u003e\u003cbr\u003eStore results in the cloud and share data with your team remotely\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eINNOVATIVE SENSOR DESIGN\u003c\/strong\u003e\u003cbr\u003eMinimize measurement variations caused by device angle or contact pressure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 805 FC Vibration Meter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow frequency range (overall measurement)\u003c\/td\u003e\n\u003ctd\u003e10 Hz to 1,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh frequency range (CF+ measurement)\u003c\/td\u003e\n\u003ctd\u003e4,000 Hz to 20,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeverity levels\u003c\/td\u003e\n\u003ctd\u003eGood, satisfactory, unsatisfactory, unacceptable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration limit\u003c\/td\u003e\n\u003ctd\u003e50 g peak (100 g peak-peak)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D converter\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal to noise ratio\u003c\/td\u003e\n\u003ctd\u003e80 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling rate\u003c\/td\u003e\n\u003ctd\u003eLow frequency: 20,000 Hz\u003cbr\u003eHigh frequency: 80,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal time clock backup\u003c\/td\u003e\n\u003ctd\u003eCoin battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eSensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e100 mV g ± 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e0.01 g to 50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow frequency range (overall measurement)\u003c\/td\u003e\n\u003ctd\u003e10 Hz to 1,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh frequency range\u003c\/td\u003e\n\u003ctd\u003e4,000 Hz to 20,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eAt 100 Hz ± 5% of measured value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eAmplitude Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcceleration\u003c\/td\u003e\n\u003ctd\u003eg, m\/sec²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelocity\u003c\/td\u003e\n\u003ctd\u003ein\/sec, mm\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplacement\u003c\/td\u003e\n\u003ctd\u003emils, mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eInfrared Thermometer (Temperature Measurement)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-20 °C to 200 °C (-4 °F to 392 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±2 °C (4 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFocal length\u003c\/td\u003e\n\u003ctd\u003eFixed, at ~3.8 cm (1.5\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eExternal Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold\"\u003eNote: Fluke supports but does not provide external sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd\u003e10 Hz to 1,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBias voltage (to supply power)\u003c\/td\u003e\n\u003ctd\u003e20 V dc to 22 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBias current (to supply power)\u003c\/td\u003e\n\u003ctd\u003eMaximum 5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eFirmware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal interfaces\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 (full speed) communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData capacity\u003c\/td\u003e\n\u003ctd\u003eDatabase on internal flash memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpgrade\u003c\/td\u003e\n\u003ctd\u003eThrough USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eUp to 3,500 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eRadiated Emission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrostatic discharge: burst\u003c\/td\u003e\n\u003ctd\u003eStandard EN 61000-4-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic interference\u003c\/td\u003e\n\u003ctd\u003eStandard EN 61000-4-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRE\u003c\/td\u003e\n\u003ctd\u003eStandard CISPR 11, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eEnvironmental\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-20 °C to 50 °C (-4 °F to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-30 °C to 80 °C (-22 °F to 176 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd\u003e10% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating\/storage altitude\u003c\/td\u003e\n\u003ctd\u003eSea level to 3,048 meters (10,000 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration limit\u003c\/td\u003e\n\u003ctd\u003e500g peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop test\u003c\/td\u003e\n\u003ctd\u003e1 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003eAA (2) Lithium Iron Disulfide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e250 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e24.1 cm x 7.1 cm x 5.8 cm\u003cbr\u003e(9.5 in x 2.8 in x 2.3 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.40 kg (0.89 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003eUSB mini-B 7-pin, external sensor jack (SMB connector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504311775317,"sku":"Fluke 805 FC","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/fluke_805_vibration_meter.jpg?v=1606294288","url":"https:\/\/www.gilautomation.com\/en-ao\/products\/fluke-805-fc-vibrationmeter-with-fluke-connect","provider":"gilautomation","version":"1.0","type":"link"}