{"product_id":"fluke-fc-wireless-essential-kit-with-a3000","title":"Fluke Fc Wireless Essential Kit With A3000","description":"\u003cdiv class=\"prodHeadTitle\"\u003e\n\u003ch2 class=\"prodHeadTitle\"\u003eFluke Fc Wireless Essential Kit With A3000\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv data-readmore=\"\" id=\"keyfeature_content\"\u003e\n\u003cp\u003eThe Fluke a3000 FC Wireless AC Current Clamp Module is a fully functional true-RMS current clamp meter that wirelessly relays measurements to other Fluke Connect® enabled master units, listed below:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 3000 FC DMM\u003c\/li\u003e\n\u003cli\u003eFluke Ti200\/300\/400 Infrared Camera\u003c\/li\u003e\n\u003cli\u003ePC via optional pc3000 FC Adapter\u003c\/li\u003e\n\u003cli\u003eFluke Connect Mobile app\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Fluke a3000 FC Wireless AC Current Clamp Module has all the essentials for convenient test and measurement troubleshooting:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrue-RMS AC clamp meter\u003c\/li\u003e\n\u003cli\u003eMeasure up to 400 A AC\u003c\/li\u003e\n\u003cli\u003eUse as a standalone meter or as part of the system\u003c\/li\u003e\n\u003cli\u003eLogging function for recording and saving up to 65,000 readings\u003c\/li\u003e\n\u003cli\u003eInrush function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke a3000 FC Wireless AC Current Clamp Kit\u003c\/h2\u003e\n\u003ch4\u003eFluke 3000 FC Series Wireless Multimeter\u003c\/h4\u003e\n\u003cp class=\"small-font\"\u003e* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ±([% of Reading] + [Number of least significant digits]).\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange¹ \/ resolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003cbr\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.0 V \/ 0.1 V\u003cbr\u003e1000 V \/ 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e45 Hz to 500 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 Hz to 1 kHz\u003c\/td\u003e\n\u003ctd\u003e2.0% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" class=\"small-font nobold\"\u003e1. All AC voltage ranges are specified from 1% of range to 100% of range.\u003cbr\u003e2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor \u0026lt; 1.5 at 1000 V.\u003cbr\u003e3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.\u003cbr\u003e4. Do not exceed 107 V-Hz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDC Voltage, Continuity, Resistance, Diode Test and Capacitance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emV\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange \/ resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.09% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eV\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange \/ resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.0 V \/ 0.1 V\u003cbr\u003e1000 V \/ 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd class=\"nobold\"\u003e0.09% + 2\u003cbr\u003e0.15% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e)))\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange \/ resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eMeter beeps at \u0026lt; 25 Ω, beeper detects opens or shorts of 250 μs or longer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eΩ\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange \/ resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 Ω \/ 0.1 Ω\u003cbr\u003e6.000 kΩ \/ 0.001 kΩ\u003cbr\u003e60.00 kΩ \/ 0.01 kΩ\u003cbr\u003e60.00 kΩ \/ 0.1 kΩ\u003cbr\u003e600.0 kΩ \/ 0.001 MΩ\u003cbr\u003e50.00 MΩ \/ 0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.5% + 2\u003cbr\u003e0.5% + 1\u003cbr\u003e1.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDiode test\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange \/ resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.000 V \/ 0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eµF\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange \/ resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 nF \/ 1 nF\u003cbr\u003e10.00 μF \/ 0.01 μF\u003cbr\u003e100.0 μF \/ 0.1 μF\u003cbr\u003e9999 μF1 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.2% + 2\u003cbr\u003e10% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" class=\"small-font nobold\"\u003e1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC and DC Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA AC\u003cbr\u003e(45 Hz to 1 kHz)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eRange\u003c\/strong\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\/ resolution\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e60.00 mA \/ 0.01 mA\u003cbr\u003e400.0 mA\/ 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA DC\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eRange\u003c\/strong\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\/ resolution\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003e60.00 mA \/ 0.01 mA\u003cbr\u003e400.0 mA\/ 0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd class=\"nobold\"\u003e0.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" class=\"small-font nobold\"\u003e1. All AC current ranges are specified from 5% of range to 100% of range.\u003cbr\u003e2. Input burden voltage (typical): 400 mA input 2 mV\/mA.\u003cbr\u003e3. 400.0 mA accuracy specified up to 600 mA overload.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eFrequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange \/ resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e99.99 Hz \/ 0.01 Hz\u003cbr\u003e999.9 Hz \/ 0.1 Hz\u003cbr\u003e9.999 kHz \/ 0.001 kHz\u003cbr\u003e99.99 kHz \/ 0.01 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1% + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" class=\"small-font nobold\"\u003e1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eInput Characteristics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg alt=\"\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/fucntion-1-05.gif\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance (nominal)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MΩ \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio\u003cbr\u003e(1 kΩ unbalance)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 120 dB at DC, 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal mode rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 60 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg alt=\"\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/fucntion-2-05.gif\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance (nominal)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MΩ \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio\u003cbr\u003e(1 kΩ unbalance)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 60 dB, DC to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal mode rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 60 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg alt=\"\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/fucntion-3-05.gif\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance (nominal)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MΩ \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio\u003cbr\u003e(1 kΩ unbalance)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 120 dB at DC, 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal mode rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 60 dB at 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eOpen Circuit Test Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg alt=\"\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/fucntion-4-05.gif\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance (nominal)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.7 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale voltage to 6 MΩ\u003cbr\u003eFull scale voltage 50 MΩ\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.7 VDC\u003cbr\u003e\u0026lt; 0.9 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical short circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 350 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003cimg alt=\"\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/fucntion-5-05.gif\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance (nominal)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.7 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale voltage to 6 MΩ\u003cbr\u003eFull scale voltage 50 MΩ\u003c\/td\u003e\n\u003ctd\u003e2.000 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical short circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003emA Function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFused, 44\/100 A, 1000 V FAST Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 mA overload for 2 minutes maximum, 10 minutes rest minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMIN\/MAX Recording Accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC functions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±12 counts for changes \u0026gt; 350 mS in duration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC functions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±40 counts for changes \u0026gt; 900 mS in duration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 VDC or AC rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eΩ fuse protection from A inputs\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.44 A (44\/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDisplay (LCD)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUpdate rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolts, amps, ohms\u003c\/td\u003e\n\u003ctd\u003e6000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e10,000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1,000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThree AA Alkaline batteries, NEDA 15A IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e250 hours minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRF communications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.4 GHZ ISM Band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eRF communication range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOpen air, unobstructed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 20 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eObstructed, sheetrock wall\u003c\/td\u003e\n\u003ctd\u003eUp to 6.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eObstructed, concrete wall, or steel electrical enclosure\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eUp to 3.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 x (specified accuracy) \/ °C (\u0026lt; 18°C or \u0026gt; 28°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0% to 90% (0°C to 35°C)\u003cbr\u003e0% to 75% (35°C to 40°C)\u003cbr\u003e0% to 45% (40°C to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compatibility\u003cbr\u003eEMI, RFI, EMC, RF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN 61326-1:2006, EN 61326-2-2:2006\u003cbr\u003eETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489\u003cbr\u003eV1.8.1:2008\u003cbr\u003eFCC Part 15 Subpart C Sections 15.207, 15.209, 15.249\u003cbr\u003eFCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety compliance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eANSI\/ISA 61010-1 \/ (82.02.01): 3rd edition\u003cbr\u003eCAN\/CSA-C22.2 No 61010-1-12: 3rd edition\u003cbr\u003eUL 61010-1: 3rd edition\u003cbr\u003eIEC\/EN 61010-1:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA, FCC, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection (IP) rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e340 g (12 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" class=\"small-font nobold\"\u003eNot compatible with Fluke CNX test tools\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"gilautomation","offers":[{"title":"Default Title","offer_id":44743646904597,"sku":"FLK - A3000FC","price":182392.0,"currency_code":"NGN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/108801_1662455114.jpg?v=1682873296","url":"https:\/\/www.gilautomation.com\/en-ao\/products\/fluke-fc-wireless-essential-kit-with-a3000","provider":"gilautomation","version":"1.0","type":"link"}