{"product_id":"fluke-prv240-proving-unit","title":"Fluke PRV240 Proving unit","description":"\u003ch2 data-mce-fragment=\"1\"\u003eProduct overview: Fluke PRV240 Proving Unit\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\" data-mce-fragment=\"1\"\u003e\n\u003cdiv id=\"product-overview\" data-mce-fragment=\"1\"\u003e\n\u003cdiv id=\"overview_content\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Fluke PRV240 Proving Unit is a portable, pocket-sized, battery-powered voltage source. It is unique because it sources stable AC and DC voltages for both LoZ and HiZ instruments.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Fluke PRV240 provides a safe method to verify that your electrical test tool is operating properly before and after you conduct any live tests. The concept of “Test Before Touch” (TBT) involves testing your meter against a known live source before and after the actual measurement. This sequence verifies that your test tool is operating properly through the actual measurement.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eProduct highlights\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eA single LED on the PRV240 indicates functionality, making this unit a simple-to-use solution for complying with TBT verification of your test tool. Voltage is sourced through recessed contacts that are activated when tested probes are inserted to avoid accidental contact. The proving unit also offers:\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eLong battery life—5,000 tests per set of four AA batteries\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eIncludes TPak™ Magnetic Hanging Strap\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eDesigned for safety and compliance\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eUsing the PRV240 reduces the need for personal protective equipment (PPE) when a known voltage source is not available for verification of your tester or multimeter, so a TBT is performed. PPE is still needed for absence of voltage testing when appropriate.\u003c\/p\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003eValidate test tool functionality outside of hazardous zones\u003c\/li\u003e\n\u003cli\u003eSupplies 240 V, both DC and AC\u003c\/li\u003e\n\u003cli\u003eCompatible with both high or low impedance test too\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke PRV240 Proving Unit\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150px;\"\u003eOutput voltage\u003c\/td\u003e\n\u003ctd style=\"width: 111.333px;\"\u003e240 V ac rms or dc\u003c\/td\u003e\n\u003ctd style=\"width: 242.667px;\"\u003e± 10 % ≥ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 111.333px;\"\u003eLoZ \u0026gt;3 kΩ load\u003c\/td\u003e\n\u003ctd style=\"width: 242.667px;\"\u003e60 V ac typical\u003cbr\u003e50 V ac rms minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150px;\"\u003eLED power indicator\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003eTurns on when output voltage is present\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150px;\"\u003eBattery\u003c\/td\u003e\n\u003ctd style=\"width: 111.333px;\"\u003e4 AA Alkaline batteries NEDA\u003c\/td\u003e\n\u003ctd style=\"width: 242.667px;\"\u003e24 A IEC LR03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150px;\"\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e5000 (5-second duration) test cycles with \u0026gt;1 MΩ load, 300 tests minimum with \u0026gt;3 kΩ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e-10 °C to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150px;\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e0 % to 90 % (0 °C to 35 °C)\u003cbr\u003e0 % to 70 % (35 °C to 55 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150px;\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e11.7 cm x 7.4 cm x 2.8 cm (4.6 in x 2.9 in x 1.1 in), Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e0.23 kg (8 oz) includes batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150px;\"\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003eIEC61010-1, IEC61010-2-030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003eOne-year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 150px;\"\u003eElectromagnetic\u003cbr\u003eCompatibility (EMC)\u003c\/td\u003e\n\u003ctd style=\"width: 111.333px;\"\u003eIEC 61326-1\u003c\/td\u003e\n\u003ctd style=\"width: 242.667px;\"\u003ePortable EM environment; CISPR 11, Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 111.333px;\"\u003eUS (FCC)\u003c\/td\u003e\n\u003ctd style=\"width: 242.667px;\"\u003e47 CFR 15 subpart B, this product is considered an exempt device per clause 15.103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 111.333px;\"\u003eKorea (KCC)\u003c\/td\u003e\n\u003ctd style=\"width: 242.667px;\"\u003eClass A Equipment (Industrial Broadcasting \u0026amp; Communication Equipment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003eThis product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434182979669,"sku":"Fluke PRV240","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/22_fbfe269f-5025-4f8f-bb5a-80538ab92768.jpg?v=1591881766","url":"https:\/\/www.gilautomation.com\/en-ao\/products\/fluke-prv240-proving-unit","provider":"gilautomation","version":"1.0","type":"link"}