{"product_id":"fluke-t110-voltage-continuity-tester-with-switchable-load","title":"Fluke T110 Voltage\/continuity tester, with switchable load","description":"\u003ch2 data-mce-fragment=\"1\"\u003eProduct overview: Fluke T110 Two-pole Voltage and Continuity Electrical Tester\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\" data-mce-fragment=\"1\"\u003e\n\u003cdiv id=\"product-overview\" data-mce-fragment=\"1\"\u003e\n\u003cdiv id=\"overview_content\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFluke T110 Voltage, Continuity Tester with switchable load\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eFluke T110 is the electrical tester you miss in your tool belt. It is a voltage tester and a continuity tester in one tool.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis electrical tester gives you fast answers and let you work in a safer way. Thanks to this electrical tester you can check the presence of voltage before working on any circuit. A clear audible and vibrating voltage indicator let you work with confidence. The Fluke T110 electrical tester features also an electric torch, a backlit LED indicator to get test results the way you want them.\u003c\/p\u003e\n\u003cp\u003eTwo-pole voltage and continuity testers measure voltage, but just as important is when a voltage tester tells you that there is NOT voltage present before working on any circuit. For you to rely on your two-pole tester, it has to be the most rugged and reliable tester you can find. That’s what Fluke’s redesigned Fluke T110 gives you.\u003c\/p\u003e\n\u003cp\u003eFluke knows the cable assembly is often where failures occur. The cable on any Two-Pole voltage and continuity tester is its weakest point- it is repeatedly bent, twisted, wrapped and put under constant strain. If the cable were to break, it could place you at an increased safety risk. Industry standards call for the cable to be tested to withstand a forty-five-degree bend, and still work after 5000 bend cycles. Fluke puts our testers through three times what the standard demands, flexing the cable over 150 degrees in each direction. This is why we can offer you our strongest voltage and continuity testers warranty ever.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual insulated cable tested to 3x the required bend angle provides increased reliability and durability\u003c\/li\u003e\n\u003cli\u003eSwitchable load: avoid display of ghost voltages allowing you to draw more current from the circuit under test and avoid trip residual-current devices (RCDs)\u003c\/li\u003e\n\u003cli\u003eBacklit graduated scale and backlit indicators\u003c\/li\u003e\n\u003cli\u003eBuilt in electric torch for use in dark areas (T110, T130, T150)\u003c\/li\u003e\n\u003cli\u003eAudio on\/off for testing in quiet areas (T110, T130, T150)\u003c\/li\u003e\n\u003cli\u003eImproved probe docking for secure storage.\u003c\/li\u003e\n\u003cli\u003ePhase rotation indicator for 3-phase systems (T110, T130, T150)\u003c\/li\u003e\n\u003cli\u003eSingle-pole phase test offers fast identification of live conductors\u003c\/li\u003e\n\u003cli\u003ePush-on probe tips, probe tip protector and storage accessory\u003c\/li\u003e\n\u003cli\u003eTip protector serves as an extra hand when opening UK electrical safety outlets\u003c\/li\u003e\n\u003cli\u003eLow battery indicator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke T110 Two-pole Voltage and Continuity Electrical Tester\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cp\u003eThe complete family of Fluke Two-Pole Voltage and Continuity testers lets you choose the features, functions, and price\/performance to fit your applications and preferences.\u003c\/p\u003e\n\u003ch3\u003eFluke voltage and continuity tester selection guide\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 26%;\"\u003eFeatures\u003c\/th\u003e\n\u003cth style=\"width: 16%;\"\u003eT150\u003c\/th\u003e\n\u003cth style=\"width: 15%;\"\u003eT130\u003c\/th\u003e\n\u003cth style=\"width: 14.1364%;\"\u003eT110\u003c\/th\u003e\n\u003cth style=\"width: 11.8636%;\"\u003eT90\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26%;\"\u003eBacklit LED indicator\u003c\/td\u003e\n\u003ctd style=\"width: 16%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 15%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 14.1364%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.8636%;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26%;\"\u003eBacklit LCD digital display\u003c\/td\u003e\n\u003ctd style=\"width: 16%;\"\u003eLCD\u003c\/td\u003e\n\u003ctd style=\"width: 15%;\"\u003eLCD\u003c\/td\u003e\n\u003ctd style=\"width: 14.1364%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 11.8636%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26%;\"\u003eContinuity test—visual results\u003c\/td\u003e\n\u003ctd style=\"width: 16%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 15%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 14.1364%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.8636%;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26%;\"\u003eContinuity test—audible results\u003c\/td\u003e\n\u003ctd style=\"width: 16%;\"\u003e•\u003cbr\u003ewith on\/off\u003c\/td\u003e\n\u003ctd style=\"width: 15%;\"\u003e•\u003cbr\u003ewith on\/off\u003c\/td\u003e\n\u003ctd style=\"width: 14.1364%;\"\u003e•\u003cbr\u003ewith on\/off\u003c\/td\u003e\n\u003ctd style=\"width: 11.8636%;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26%;\"\u003eVibratory indicator under load\u003c\/td\u003e\n\u003ctd style=\"width: 16%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 15%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 14.1364%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.8636%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26%;\"\u003eDisplay hold\u003c\/td\u003e\n\u003ctd style=\"width: 16%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 15%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 14.1364%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 11.8636%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26%;\"\u003eVoltage test\u003c\/td\u003e\n\u003ctd style=\"width: 16%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 15%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 14.1364%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.8636%;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26%;\"\u003eIndication of polarity\u003c\/td\u003e\n\u003ctd style=\"width: 16%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 15%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 14.1364%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.8636%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26%;\"\u003eResistance measurement\u003c\/td\u003e\n\u003ctd style=\"width: 16%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 15%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 14.1364%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 11.8636%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26%;\"\u003eSwitchable load\u003c\/td\u003e\n\u003ctd style=\"width: 16%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 15%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 14.1364%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.8636%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26%;\"\u003eSingle pole test for phase detection\u003c\/td\u003e\n\u003ctd style=\"width: 16%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 15%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 14.1364%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.8636%;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26%;\"\u003eRotary field indicator\u003c\/td\u003e\n\u003ctd style=\"width: 16%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 15%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 14.1364%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.8636%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26%;\"\u003eProbe tip protection\u003c\/td\u003e\n\u003ctd style=\"width: 16%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 15%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 14.1364%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.8636%;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26%;\"\u003eVoltage detection with discharged batteries\u003c\/td\u003e\n\u003ctd style=\"width: 16%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 15%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 14.1364%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.8636%;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26%;\"\u003eElectrical torch function\u003c\/td\u003e\n\u003ctd style=\"width: 16%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 15%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 14.1364%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.8636%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26%;\"\u003eWear indicator test lead wire\u003c\/td\u003e\n\u003ctd style=\"width: 16%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 15%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 14.1364%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.8636%;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434182389845,"sku":"Fluke T110","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/47b.jpg?v=1592313908","url":"https:\/\/www.gilautomation.com\/en-ao\/products\/fluke-t110-voltage-continuity-tester-with-switchable-load","provider":"gilautomation","version":"1.0","type":"link"}