{"product_id":"fluke-t6-1000-eu-electrical-tester-with-fieldsense™-round","title":"Fluke T6-1000\/EU Electrical Tester with FieldSense™","description":"\u003ch2\u003eProduct overview: Fluke T6-1000 Electrical Tester\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003ch3\u003eMeasure voltage without test leads\u003c\/h3\u003e\n\u003cp\u003eThe Fluke T6-1000 Electrical Tester with FieldSense™ technology lets you quickly, safely take True rms voltage and current measurements without test leads.\u003c\/p\u003e\n\u003cp\u003eUnlike other fork testers that merely detect voltage, the T6-1000 makes actual measurements, without contacting a live, metallic conductor. Just slide the 17.8 mm open fork, the widest in the industry, over a conductor and read simultaneous voltage and current values. Or simultaneous frequency and current values. The open fork works with wires up to AWG 4\/0 (120 mm2). Or, you can use the attached test leads to measure voltage DC to 1000 V.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrue rms voltage and current to 200 A AC, 1000 V AC\u003c\/li\u003e\n\u003cli\u003eResistance 1 Ω to 100 kΩ\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWork on any jobsite\u003c\/h3\u003e\n\u003cp\u003eMake use of the HOLD button to temporarily freeze the reading on the screen so you can keep working with the same measurement up. Plus, the display features large, easy-to-read numbers and a backlight for darker work environments or inside cabinets. The T6-1000 works with the Fluke TPACK ToolPak™ Magnetic Meter Hanger to make it even more convenient.\u003c\/p\u003e\n\u003ch3\u003eHow FieldSense™ technology works\u003c\/h3\u003e\n\u003cp\u003eFieldSense ™ technology is different than other open fork testers work by interpreting a magnetic field to show AC current. FieldSense™ detects an electrical field that interacts with a T6 reference signal, showing a voltage value on the tester’s display.\u003c\/p\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure voltage to 1000 V AC without test leads\u003c\/li\u003e\n\u003cli\u003eSimultaneously measure voltage and current\u003c\/li\u003e\n\u003cli\u003e17.8 mm open fork is widest in the industry\u003c\/li\u003e\n\u003cli\u003eMeasure up to 200 A on 4\/0 wires (120 mm2)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke T6-1000 Electrical Tester\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\" style=\"width: 489px;\"\u003eMeasurement Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 94px;\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 94px;\"\u003e\u003cstrong\u003eRequires test leads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 86.6667px;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 89.3333px;\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e\u003cstrong\u003eAccuracy\u003csup\u003e[1]\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 94px;\"\u003eFieldSense\u003cbr\u003eac voltage true-rms\u003c\/td\u003e\n\u003ctd style=\"width: 94px;\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"width: 86.6667px;\"\u003e1000 V\u003c\/td\u003e\n\u003ctd style=\"width: 89.3333px;\"\u003e1 V\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± (3 % + 3 counts) 45 Hz - 66 Hz\u003csup\u003e[2][3]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 94px;\"\u003eFieldSense\u003cbr\u003eac current true-rms\u003c\/td\u003e\n\u003ctd style=\"width: 94px;\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"width: 86.6667px;\"\u003e200.0 A\u003c\/td\u003e\n\u003ctd style=\"width: 89.3333px;\"\u003e0.1 A\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± (3% + 3 counts) 45 Hz - 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 94px;\"\u003eFieldSense\u003cbr\u003efrequency (Hz)\u003c\/td\u003e\n\u003ctd style=\"width: 94px;\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"width: 86.6667px;\"\u003e45 Hz – 66 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 89.3333px;\"\u003e1 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± (1% + 2 counts)\u003csup\u003e[3]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 94px;\"\u003eVolts ac true-rms\u003c\/td\u003e\n\u003ctd style=\"width: 94px;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"width: 86.6667px;\"\u003e1000 V\u003c\/td\u003e\n\u003ctd style=\"width: 89.3333px;\"\u003e1 V\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± (1.5% + 2 counts) 45 Hz - 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 94px;\"\u003eVolts dc\u003c\/td\u003e\n\u003ctd style=\"width: 94px;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"width: 86.6667px;\"\u003e1000 V\u003c\/td\u003e\n\u003ctd style=\"width: 89.3333px;\"\u003e1 V\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± (1% + 2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 94px;\"\u003eResistance\u003c\/td\u003e\n\u003ctd style=\"width: 94px;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"width: 86.6667px;\"\u003e2000 Ω\u003c\/td\u003e\n\u003ctd style=\"width: 89.3333px;\"\u003e1 Ω\u003c\/td\u003e\n\u003ctd rowspan=\"3\" style=\"width: 125px;\"\u003e± (1% + 2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 94px;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"width: 86.6667px;\"\u003e20.00 kΩ\u003c\/td\u003e\n\u003ctd style=\"width: 89.3333px;\"\u003e0.01 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 94px;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"width: 86.6667px;\"\u003e100.0 kΩ\u003c\/td\u003e\n\u003ctd style=\"width: 89.3333px;\"\u003e0.1 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 94px;\"\u003eSafety\u003c\/td\u003e\n\u003ctd style=\"width: 94px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 86.6667px;\"\u003e1000 V CAT III\u003cbr\u003e600 V CAT IV\u003c\/td\u003e\n\u003ctd style=\"width: 89.3333px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" style=\"width: 489px;\"\u003e\n\u003cp\u003e\u003csmall\u003eAccuracy\u003csup\u003e[1]\u003c\/sup\u003e: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.\u003c\/small\u003e\u003cbr\u003e\u003csmall\u003eAccuracy\u003csup\u003e[2]\u003c\/sup\u003e: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.\u003c\/small\u003e\u003cbr\u003e\u003csmall\u003eAccuracy\u003csup\u003e[3]\u003c\/sup\u003e: FieldSense is specified from 16 V to 100 % of range.\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n \n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"3\" style=\"width: 505px;\"\u003eGeneral Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 143px;\"\u003eCalibration\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 362px;\"\u003e1-year calibration cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 143px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 362px;\"\u003e61.1 x 259.3 x 43.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 143px;\"\u003eJaw opening\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 362px;\"\u003e17.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 143px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 362px;\"\u003e0.35 kg (0.78 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 143px;\"\u003eTemperature\u003c\/td\u003e\n\u003ctd style=\"width: 125.333px;\"\u003e\u003cstrong\u003eOperating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 236.667px;\"\u003e-10 °C to +50 °C (14 °F to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 125.333px;\"\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 236.667px;\"\u003e-30 °C to +60 °C (-22 °F to +140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 143px;\"\u003eAltitude\u003c\/td\u003e\n\u003ctd style=\"width: 125.333px;\"\u003e\u003cstrong\u003eOperating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 236.667px;\"\u003e2,000 m (6,562 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 125.333px;\"\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 236.667px;\"\u003e10,000 m (32,808 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 143px;\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 362px;\"\u003e0% to 90%, 5 °C to 30 °C (41 °F to 86 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 362px;\"\u003e0% to 75%, 30°C to 40 °C (86 °F to 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 362px;\"\u003e0% to 45%, 40°C to 50 °C (104 °F to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 143px;\"\u003eBattery Type and Life\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 362px;\"\u003e2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 143px;\"\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 362px;\"\u003e0.1 x (specified accuracy) \/ °C for \u0026lt;18°C or \u0026gt;28 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 362px;\"\u003e0.1 x (specified accuracy) \/ °C for \u0026lt;18°C or \u0026gt;28 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 143px;\"\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 362px;\"\u003eIEC\/EN 61010-1: Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 143px;\"\u003eElectromagnetic Environment\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 362px;\"\u003eIEC\/EN 61326-1: Portable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434182127701,"sku":"Fluke T6-1000\/EU","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/T6-1000.png?v=1598015675","url":"https:\/\/www.gilautomation.com\/en-ao\/products\/fluke-t6-1000-eu-electrical-tester-with-fieldsense%e2%84%a2-round","provider":"gilautomation","version":"1.0","type":"link"}