{"product_id":"fluke-t6-600-eu-electrical-tester-with-fieldsense™-round","title":"Fluke  T6-600\/EU Electrical Tester with FieldSense™, round","description":"\u003cp\u003eT6-600\/EU T6-600\/EU,ELECTRICAL TESTER W\/FIELDSENSE(TM), ROUND\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eProduct overview: Fluke T6-600 Electrical Tester\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003ch3\u003eMeasure voltage … without test leads\u003c\/h3\u003e\n\u003cp\u003eWorking in cramped electrical boxes and trying to find a safe metallic contact points is often challenging. The Fluke T6-600 Electrical Tester with FieldSense™ technology, lets you quickly and safely take measurements by sliding the open fork over a conductor, without the need for test leads. The T6-600 works with wires up to AWG 4\/0 (120 mm2) with a 17.8 mm jaw opening\u003c\/p\u003e\n\u003ch3\u003eHow FieldSense™ technology works\u003c\/h3\u003e\n\u003cp\u003eFieldSense™ technology is a breakthrough in how voltage is measured. Other open fork testers detect a magnetic field to show AC current. FieldSense™ technology detects an electrical field, which interacts with a reference signal created by the T6 tester, which shows the measurement value on the tester’s display.\u003c\/p\u003e\n\u003cp\u003eTips on using FieldSense technology\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDo not hold or touch wire you are testing during a measurement.\u003c\/li\u003e\n\u003cli\u003eUse the black probe to make the ground connection if you are wearing gloves, insulated footwear or standing on an insulated ladder\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMeasurement versatility\u003c\/h3\u003e\n\u003cp\u003eThe electrical tester offers a variety of measurement options giving you an all-in-one troubleshooting tool. Measure true rms voltage and current from 0 to 200 A AC or 1 to 600 V AC or DC. You can also gather resistance measurement from 1 Ω to 2000 Ω. With the easy-to-read backlit display, you can keep see your work in dark environments and keep your most recent measurement on the screen with the HOLD button for easy viewing. The T6-600 also accepts optional Fluke TPAK Magnetic Meter Hanger for convenient operation.\u003c\/p\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure AC voltage, current, frequency without touching a live wire\u003c\/li\u003e\n\u003cli\u003eTroubleshoot with all power supply measurements at-a-glance\u003c\/li\u003e\n\u003cli\u003eSee AC voltage and current values without test leads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke T6-600 Electrical Tester\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003ctable\u003e\n\u003ccaption\u003eMeasurement Specifications\u003c\/caption\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRequires test leads\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003csup\u003e[1]\u003c\/sup\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldSense\u003cbr\u003eac voltage true-rms\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003ctd\u003e±(3% + 3 counts) 45 Hz - 66 Hz\u003csup\u003e[2] [3]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldSense\u003cbr\u003eac current true-rms\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e200.0 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±(3% + 3 counts) 45 Hz - 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldSense\u003cbr\u003efrequency (Hz)\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 Hz\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2 counts)\u003csup\u003e[3]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVolts ac true-rms\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 2 counts) 45 Hz - 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVolts dc\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e2000 Ω\u003c\/td\u003e\n\u003ctd\u003e1 Ω\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e600 V CAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cp\u003eAccuracy\u003csup\u003e[1]\u003c\/sup\u003e: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.\u003c\/p\u003e\n\u003cp\u003eAccuracy\u003csup\u003e[2]\u003c\/sup\u003e: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.\u003c\/p\u003e\n\u003cp\u003eAccuracy\u003csup\u003e[3]\u003c\/sup\u003e: FieldSense is specified from 16 V to 100 % of range.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ccaption\u003eGeneral Specifications\u003c\/caption\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCalibration\u003c\/th\u003e\n\u003ctd colspan=\"2\"\u003e1-year calibration cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd colspan=\"2\"\u003e61.1 x 259.3 x 43.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eJaw opening\u003c\/th\u003e\n\u003ctd colspan=\"2\"\u003e17.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd colspan=\"2\"\u003e0.35 kg (0.78 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\"\u003eTemperature\u003c\/th\u003e\n\u003cth\u003eOperating\u003c\/th\u003e\n\u003ctd\u003e-10 °C to +50 °C (14 °F to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage\u003c\/th\u003e\n\u003ctd\u003e-30 °C to +60 °C (-22 °F to +140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\"\u003eAltitude\u003c\/th\u003e\n\u003cth\u003eOperating\u003c\/th\u003e\n\u003ctd\u003e2,000 m (6,562 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage\u003c\/th\u003e\n\u003ctd\u003e10,000 m (32,808 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"3\"\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd colspan=\"2\"\u003e0% to 90%, 5 °C to 30 °C (41 °F to 86 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e0% to 75%, 30°C to 40 °C (86 °F to 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e0% to 45%, 40°C to 50 °C (104 °F to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery Type and Life\u003c\/th\u003e\n\u003ctd colspan=\"2\"\u003e2 x AA (IEC LR6); 360 hours continuous, typical; 200 hours using FieldSense\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth rowspan=\"2\"\u003eTemperature coefficient\u003c\/th\u003e\n\u003ctd colspan=\"2\"\u003e0.1 x (specified accuracy) \/ °C for \u0026lt;18°C or \u0026gt;28 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e(\u0026lt; 64.4 °F or \u0026gt; 82.4 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd colspan=\"2\"\u003eIEC\/EN 61010-1: Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectromagnetic Environment\u003c\/th\u003e\n\u003ctd colspan=\"2\"\u003eIEC\/EN 61326-1: Portable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434182160469,"sku":"Fluke T6-600\/EU","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/5_7c4d2093-7295-4218-8332-9b398f74baea.jpg?v=1591882956","url":"https:\/\/www.gilautomation.com\/en-ao\/products\/fluke-t6-600-eu-electrical-tester-with-fieldsense%e2%84%a2-round","provider":"gilautomation","version":"1.0","type":"link"}