Siemens 3KA5840-1GE01 Switch disconnector in new design Iu=630 A, Ue = 690 V, 4-pole 4th pole selectable, AC-21A with door drive 8UC7 Handle dark blue/blue-green Basic masking frame light gray

Save ₦323,336

Price:
₦1,676,664 ₦2,000,000
request for quote

Description

Switch disconnector in new design Iu=630 A, Ue = 690 V, 4-pole 4th pole selectable, AC-21A with door drive 8UC7 Handle dark blue/blue-green Basic masking frame light gray Product phase-out since: 31.08.18 Successor:3KD4640-0QE20-0, diff. dimen, deviat. techn. data, w/o door coupl rot oper mech

Model
product brand name SENTRON
product designation Switch Disconnector 3KA
Design type For mounting and installation
design of the operating mechanism manual operating mechanism
design of the load switch / strip form No
type of the driving mechanism / motor drive No
type of device fixed mounting
protection against electrical shock finger-safe
insulation voltage / rated value 1 000 V
type of voltage AC/DC
operating voltage
● at AC / at 50/60 Hz / rated value
● at DC / rated value
690 V
440 V
Protection class
protection class IP IP00
Dissipation
power loss [W] / for rated value of the current / at AC
/ in hot operating state / per pole
56.6 W
Current
Let-through current / I2 t / maximum permissible / in
utilization category / AC-22 B / at 400 V
2 600 000 A²·s
Main circuit
number of poles / for main current circuit 4
operating power  
● at AC-23 A / at 400 V / at 50/60 Hz / rated value 350 000 W
● at AC-23 A / at 400 V / rated value 350 000 W
● at AC-23 A / at 500 V / rated value 350 000 W
● at AC-23 A / at 690 V / at 50/60 Hz / rated value 280 000 W
operating current / rated value 630 A
Rated current Ie / maximum / in utilization category  
● AC-21 A / at 400 V 630 A
● AC-21 A / at 500 V 630 A
● AC-21 B / at 400 V 630 A
● AC-21 B / at 500 V 630 A
● AC-22 A / at 400 V 630 A
● AC-22 A / at 500 V 630 A
● AC-22 B / at 400 V 630 A
● AC-22 B / at 500 V 630 A
Auxiliary circuit
number of CO contacts / for auxiliary contacts 0
number of NC contacts / for auxiliary contacts 0
number of NO contacts / for auxiliary contacts 0
Short circuit
maximum short-circuit current breaking capacity (Icu)
/ at 400 V / rated value
65 kA
Conditional rated short-circuit current  
● 400V 55 kA
● 500V 55 kA
● in utilization category / AC-21 A / at 400 V 55 kA
● in utilization category / AC-21 A / at 500 V 55 kA
● in utilization category / AC-21 B / at 400 V 55 kA
● in utilization category / AC-21 B / at 500 V 55 kA
● in utilization category / AC-22 A / at 400 V 55 kA
● in utilization category / AC-22 A / at 500 V 55 kA
● in utilization category / AC-22 B / at 400 V 55 kA
● in utilization category / AC-22 B / at 500 V 55 kA
Connections
connectable conductor cross-section / for main contacts
● stranded / maximum
480 mm²
Type of connection, main circuit Flat-type screw terminal
type of electrical connection
● for main current circuit
flat connector
Mechanical Design
height 180 mm
width 293 mm
depth 207 mm
Type of mounting fixed mounted
mounting type floor mounting
mounting type
● front mounting with 4-hole attachment
● front mounting with central attachment
● rail mounting
No No No
mounting position any
net weight 6.57 kg
Environmental conditions
ambient temperature / during operation
● minimum
● maximum
-25 °C
55 °C
ambient temperature / during storage
● minimum
● maximum
-50 °C
80 °C