Description
TRANSFER SWITCH EQUIP MTSE 415V 16A 4P.
Model | ||||||||||||
product brand name | SENTRON | |||||||||||
product designation | 3KC transfer switching equipment | |||||||||||
design of the product | manually operated | |||||||||||
display version / for switch position indicator door- coupling rotary operating mechanism |
I ON- O OFF- II ON | |||||||||||
design of the operating mechanism | Without handle | |||||||||||
design of handle | without | |||||||||||
type of the driving mechanism | Front operating mechanism | |||||||||||
type of the driving mechanism / motor drive | No | |||||||||||
General technical data | ||||||||||||
number of poles | 4 | |||||||||||
type of device | fixed mounting | |||||||||||
size of switch disconnector | 1 | |||||||||||
I2t value ● with closed switch / for combination switch + fuse / at 500 V / maximum ● with closed switch / at 690 V / for combination switch + gG fuse / maximum |
13 300 A²·s 13 700 A²·s |
|||||||||||
● of the fuse / at 415 V / maximum permissible | 26 505 A²·s | |||||||||||
● of the fuse / at 500 V / maximum permissible | 26 505 A²·s | |||||||||||
● of the gG fuse / at 690 V / maximum permissible | 24 005 A²·s | |||||||||||
● with closed switch / for combination switch + fuse / at 415 V / maximum | 13 300 A²·s | |||||||||||
mechanical service life (switching cycles) / for function sequence O-I-O / typical |
15,000 | |||||||||||
position / of the switch operating mechanism | in center | |||||||||||
overvoltage category | III | |||||||||||
degree of pollution | 3 | |||||||||||
insulation voltage ● rated value |
1 000 V | |||||||||||
Supply voltage | ||||||||||||
operating current / at AC / rated value | 16 A | |||||||||||
operating voltage ● at AC / at 50/60 Hz / rated value |
415 V | |||||||||||
Protection class | ||||||||||||
protection class IP | IP20 | |||||||||||
protection class IP | ||||||||||||
● with closed switch / with cover or cable lug | IP20 | |||||||||||
cover | ||||||||||||
● on the front | IP20 | |||||||||||
Dissipation | ||||||||||||
power loss [W] ● with conventional rated thermal current / per pole ● with conventional rated thermal current / per device ● for rated value of the current / at AC / in hot operating state / per pole |
0.2 W 0.8 W 0.2 W |
|||||||||||
● operating current / at AC-23 A / at 690 V / rated value |
16 A | |||||||||||
● operating current / at AC-23 A / at 500 V / rated value | 16 A | |||||||||||
● operating current / at AC-22 A / at 690 V / rated value | 16 A | |||||||||||
● operating current / at AC-22 A / at 500 V / rated value | 16 A | |||||||||||
● operating current / at AC-21 / at 690 V / rated value | 16 A | |||||||||||
● operating current / at AC-21 / at 500 V / rated value | 16 A | |||||||||||
● operating current / at AC-21 A / at 415 V / rated value ● operating current / at AC-22 A / at 415 V / rated value ● operating current / at AC-23 A / at 415 V / rated value ● operating current / at AC-31 B / at 415 V / rated value ● operating current / at AC-32 B / at 415 V / rated value ● operating current / at AC-33 B / at 415 V / rated value ● operating current / at AC-33 iB / at 415 V / rated value ● operating current / at AC-35 B / at 400 V / rated value |
16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A |
|||||||||||
continuous current ● rated value ● at 40 °C / rated value ● at 45 °C / rated value ● at 50 °C / rated value ● at 55 °C / rated value ● at 60 °C / rated value ● at 65 °C / rated value ● at 70 °C / rated value |
16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A |
|||||||||||
operating current / of upstream fuse / rated value | 63 A | |||||||||||
let-through current / of the fuse / at 500 V / maximum permissible |
8 135 A | |||||||||||
let-through current / of the gG fuse / at 690 V / maximum permissible |
8 805 A | |||||||||||
let-through current / with closed switch ● at 690 V / for combination switch + gG fuse / maximum permissible ● for combination switch + fuse / at 500 V / maximum permissible |
7 500 A 7 000 A |
|||||||||||
Main circuit | ||||||||||||
operating power ● at AC-23 A / at 400 V / at 50/60 Hz / rated value ● at AC-23 A / at 500 V / rated value ● at AC-23 A / at 690 V / at 50/60 Hz / rated value |
7.5 kW 7.5 kW 11 kW |
|||||||||||
operating current / rated value | 16 A | |||||||||||
Auxiliary circuit | ||||||||||||
number of connected NC contacts / for auxiliary contacts |
0 | |||||||||||
number of connected NO contacts / for auxiliary contacts |
0 | |||||||||||
number of connected CO contacts / for auxiliary contacts |
0 | |||||||||||
number of CO contacts / for auxiliary contacts | 8 | |||||||||||
number of NC contacts / for auxiliary contacts | 0 | |||||||||||
number of NO contacts / for auxiliary contacts | 0 | |||||||||||
suitability for use ● main switch ● switch disconnector ● EMERGENCY OFF switch ● safety switch ● maintenance/repair switch |
Yes Yes Yes Yes Yes | |||||||||||
product feature / interlock | No | |||||||||||
product extension / auxiliary switch | Yes | |||||||||||
product extension / optional ● motor drive ● voltage trigger |
No No | |||||||||||
Short circuit | ||||||||||||
short-circuit current making capacity (Icm) / for switch disconnector ● at AC 415 V / without fuse link / acc. to IEC 60947-6-1 / rated value / minimum ● at AC 690 V / without fuse link / acc. to IEC 60947-3 / rated value / minimum |
7.7 kA 7 kA | |||||||||||
conditional short-circuit current / with line-side fuse protection |
||||||||||||
● at 415 V / by gG fuse / acc. to IEC 60947-6-1 / rated value | 100 kA | |||||||||||
● at 415 V / by gG fuse / rated value | 100 kA | |||||||||||
● at 500 V / by gG fuse / acc. to IEC 60947-3 / rated value | 100 kA | |||||||||||
● at 690 V / by gG fuse / acc. to IEC 60947-3 / rated value | 100 kA | |||||||||||
Connections | ||||||||||||
type of connectable conductor cross-sections / with flexible busbar | 2x (0.8x9 mm²) | |||||||||||
type of connectable conductor cross-sections ● for copper busbar |
1x (2x9 mm²) | |||||||||||
type of connectable conductor cross-sections / for copper conductor |
||||||||||||
● solid ● finely stranded / with core end processing ● stranded |
1x (1 ... 16 mm²) 1x (1 ... 35 mm²) 1x (6 ... 35 mm²) |
|||||||||||
type of electrical connection ● for main current circuit |
box terminal | |||||||||||
Mechanical Design | ||||||||||||
height | 119 mm | |||||||||||
width | 237.6 mm | |||||||||||
depth | 84.5 mm | |||||||||||
mounting type | Screw fixing and standard rail mounting 35 mm | |||||||||||
mounting type ● front mounting with 4-hole attachment ● front mounting with central attachment ● rail mounting |
No No Yes | |||||||||||
mounting position | any | |||||||||||
net weight | 1 700 g | |||||||||||
Environmental conditions | ||||||||||||
ambient temperature / during operation ● minimum ● maximum |
-25 °C 70 °C |
|||||||||||
ambient temperature / during storage ● minimum ● maximum |
-50 °C 80 °C |
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.