{"title":"Best selling products","description":null,"products":[{"product_id":"wago-206-503-spare-blade","title":"Wago 206-503 Spare blade","description":"\u003cp\u003eSpare blade for wire cutter\u003c\/p\u003e","brand":"WAGO","offers":[{"title":"Default Title","offer_id":32254663655509,"sku":"206-503","price":165842.68,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/206-503.jpg?v=1589879576"},{"product_id":"fluke-3000fc-eda2-electronics-multimeter-and-deluxe-accessory-kit","title":"Fluke 3000FC\/EDA2 Electronics multimeter and deluxe accessory kit","description":"\u003cp\u003eFLK-3000FC\/EDA2 FLK-3000FC\/EDA2,ELECTRONICS DMM AND DELUXE ACCESSORY KIT\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFluke 3000FC\/EDA2\u003cbr\u003eWireless True-RMS Digital Multimeter Combo Kit with Fluke Connect Compatibility and Deluxe Accessories\u003cbr\u003eThe Fluke 3000FCEDA2 Wireless True-RMS Digital Multimeter Combo Kit with Fluke Connect Compatibility and Deluxe Accessories includes a True-RMS digital multimeter and an assortment of deluxe accessories.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 3000FC Wireless True-RMS Digital Multimeter with Fluke Connect Compatibility provides all the facts right in the field. With its precision, reliability, and ease of use, the Fluke 3000 FC Wireless Multimeter has all the essential electrical and electronic troubleshooting features professional technicians need. It gives you true-RMS voltage and current measurements, 6000-count resolution, manual and automatic ranging, plus a frequency, capacitance, resistance, continuity and diode measurements.\u003c\/p\u003e\n\u003cp\u003eReduces Arc Flash Risk\u003cbr\u003eIndependently tested for safe use in CAT IV 600V\/CAT III 1000 V environments, the Fluke 3000 FC DMM and Fluke Connect wireless modules put tools, not your body, near live electrical panels. Just de-energize the cabinet; open the panel while wearing PPE; and connect the remote modules—voltage modules, current clamps, flexible current loops or thermometers. Then read the results on the 3000 FC from a safe distance up to away. You can view the meter measurement, plus readings from up to three wireless modules all on the same screen. And by separating yourself from hazardous measurement situations you’ll reduce the risk of arc flash.\u003c\/p\u003e\n\u003cp\u003e Communicate with iOS (4s and later) and Android (V4.3 and up) devices with Fluke Connect mobile app\u003c\/p\u003e\n\u003cp\u003eWireless technology allows connectivity between phone, PC, and Fluke Connect-enabled test tools\u003cbr\u003eTeam can see what you see remotely with ShareLive video calls\u003cbr\u003eSave money and time by taking multiple measurements simultaneously\u003cbr\u003eIsolate intermittent events or record signal fluctuations without being on-site, using log function\u003cbr\u003eWork with fewer interruptions by recording multiple sessions before downloading\u003cbr\u003eSave data to PC in .csv format (comma separated variable) file format\u003cbr\u003eCapture readings at different intervals with user-set recording intervals, from one second to up to one hour\u003cbr\u003eSend and communicate test data to managers and coworkers to assess abnormal system responses in an instant\u003cbr\u003eHave all asset test results at your fingertips after downloading to PC for future asset performance, tracking and reliability programs\u003cbr\u003eCapture up to 65,000 sets of MIN\/MAX\/AVG readings over single or multiple logging sessions, using recording capability; each reading and session is time stamped\u003cbr\u003eAvoid awkward or uncomfortable measurement positions; set up measurements once and read it as many times as you want, whenever you want\u003cbr\u003eView up to 6 live readings at once on the Fluke Connect mobile app or a PC to get a complete understanding of the situation\u003cbr\u003eEasily see backlit displays in dark or dimly lit work environments\u003cbr\u003eChoose auto or manual ranging\u003cbr\u003eIntegrated holster protects meter, while probe holders keep accessories organized\u003cbr\u003eBe in multiple places at once, reducing risk of arc flash by keeping distance from hazardous measurement situations\u003cbr\u003e3000 FC\u003cbr\u003eAC and DC voltage measurements to 1000V\u003cbr\u003eAC and DC current with 0.01mA resolution\u003cbr\u003eMeasure continuity, resistance, diode test, capacitance and frequency\u003cbr\u003eMIN\/MAX recording\u003cbr\u003eSafety standards: Measurement Category 1000V CAT III and Category IV 600V\u003cbr\u003eFluke Connect Mobile App\u003cbr\u003eAutoRecord measurements: Take measurements automatically and instantly save them to your phone; wirelessly save measurements to Fluke Cloud and add text or audio annotations\u003cbr\u003eTrendIt graphs: Trend measurements from a single session in a time series graph\u003cbr\u003eShareLive video call: View live tool measurements, video and audio to collaborate in real time with your entire team, without leaving the field\u003cbr\u003eFluke Cloud storage: Securely store up to 5 GB of data securely, per user\u003cbr\u003eReports: Create reports with accurate and traceable maintenance data\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434177638485,"sku":"Fluke 3000FC\/EDA2","price":308660.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/1qw.jpg?v=1592232173"},{"product_id":"fluke-116-323-kit-fluke-hvac-true-rms-multimeter-and-clamp-meter-combo-kit","title":"Fluke 116\/323 Kit Fluke HVAC True RMS multimeter and Clampmeter Combo Kit","description":"\u003cp\u003eFLUKE-116\/323 KIT FLUKE-116\/323 KIT,HVAC MULTIMETER AND CLAMP METER COMBO KIT\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 116 Digital Multimeter. Designed by Electricians. Engineered by Fluke.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in thermometer for HVAC applications\u003c\/li\u003e\n\u003cli\u003eMicroamps to test flame sensors\u003c\/li\u003e\n\u003cli\u003eLow input impedance: helps prevent false readings due to ghost voltage\u003c\/li\u003e\n\u003cli\u003eLarge white LED backlight to work in poorly lit areas\u003c\/li\u003e\n\u003cli\u003eResistance, continuity, frequency and capacitance\u003c\/li\u003e\n\u003cli\u003eMin\/Max\/Average with elapsed time to record signal fluctuations\u003c\/li\u003e\n\u003cli\u003eCompact ergonomic design for one-handed operation\u003c\/li\u003e\n\u003cli\u003eCompatible with optional magnetic hanger (ToolPak™)\u003c\/li\u003e\n\u003cli\u003eCAT III 600 V safety rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 323 True-rms Clamp Meter. Rugged. Reliable. Precise.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e400 A AC current measurement\u003c\/li\u003e\n\u003cli\u003e600 VAC and DC voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue RMS AC voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eResistance measurement up to 40 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eSlim, ergonomic design\u003c\/li\u003e\n\u003cli\u003eCAT IV 300 V\/CAT III 600 V safety rating\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434177867861,"sku":"Fluke 116\/323 Kit","price":145490.4,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/24_be4cbec3-0ebb-482e-b222-4d959186cde5.jpg?v=1591887804"},{"product_id":"fluke-c90-softmeter-case","title":"Fluke C90 Soft Carrying Case For Dmm And Visual Ir Thermometers","description":"\u003ctable class=\"_3a09a_1e-gU\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFluke\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty Period\u003c\/td\u003e\n\u003ctd\u003e6 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"_70850_1nP4u\"\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"overview_content\"\u003e\n\u003ch2\u003e \u003c\/h2\u003e\n\u003ch2\u003eFluke C90 Soft Carrying Case For Dmm And Visual Ir Thermometers\u003c\/h2\u003e\n\u003cdiv class=\"product-tabs tab-pane active\" id=\"tab0\"\u003e\n\u003ch4\u003eFluke C90 Offers\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eZippered carrying case with padding\u003c\/li\u003e\n\u003cli\u003eInside pocket\u003c\/li\u003e\n\u003cli\u003e3 in. belt loop\u003c\/li\u003e\n\u003cli\u003eFor use with Fluke Multimeters and Visual IR Thermometers\u003c\/li\u003e\n\u003cli\u003eOne year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDimensions: 8 x 3.5 x 2.8\" (205 x 90 x 72 mm)\u003c\/p\u003e\n\u003cdiv class=\"product-tabs tab-pane active\" id=\"tab2\"\u003e\n\u003ch4\u003eWhat's included with the Fluke C90\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFluke C90 Soft Carrying Case for DMM and Visual IR Thermometers\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eZippered carrying case with padding\u003c\/li\u003e\n\u003cli\u003eInside pocket\u003c\/li\u003e\n\u003cli\u003e3 in. belt loop\u003c\/li\u003e\n\u003cli\u003eFor use with Fluke Multimeters and Visual IR Thermometers\u003c\/li\u003e\n\u003cli\u003eOne\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434178097237,"sku":"Fluke C90","price":41480.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/25_8c4e9e84-351b-42c0-a641-1fccbf244c46.jpg?v=1591717913"},{"product_id":"fluke-287-fvf-ir3000-fluke-287-flukeview®-forms-combo-kit","title":"Fluke 287\/FVF\/IR3000 Fluke 287 FlukeView® Forms Combo Kit","description":"\u003cp\u003eFLK-287\/FVF\/IR3000 FLK-287\/FVF\/IR3000,287 MULTIMETER WITH SOFTWARE AND WIRELESS CONNECTIVITY KIT\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with Fluke Connect mobile app and all Fluke FC enabled test tools with optional IR3000 FC infrared connector (sold separately)\u003c\/li\u003e\n\u003cli\u003eShareLive™ video call (requires Fluke Connect mobile app and ir3000 FC wireless connector which is sold separately)\u003c\/li\u003e\n\u003cli\u003eTrendCapture quickly graphically displays logged data session to quickly determine whether anomalies may have occurred\u003c\/li\u003e\n\u003cli\u003eZoom on trend provides unprecedented ability to view and analyze TrendCapture data; zoom in up to 14 times\u003c\/li\u003e\n\u003cli\u003eSelectable AC filter (smoothing mode) helps display a steadier reading when the input signal is changing rapidly or noisy\u003c\/li\u003e\n\u003cli\u003eAdjustable recording and auto hold thresholds, specify a percentage change in the readings that begins a new event\u003c\/li\u003e\n\u003cli\u003eLarge 50,000 count, ¼ VGA display with white backlight\u003c\/li\u003e\n\u003cli\u003eMultiple sets of measurement information can be simultaneously displayed at the same time\u003c\/li\u003e\n\u003cli\u003eLogging function with expanded memory for unattended monitoring of signals over time\u003c\/li\u003e\n\u003cli\u003eUsing on-board TrendCapture users can graphically review logged readings without needing a PC that stores up to 15,000 recorded events\u003c\/li\u003e\n\u003cli\u003eOn board help screens for measurement functions\u003c\/li\u003e\n\u003cli\u003eSaved measurements allow you to name and recall measurements made in the field\u003c\/li\u003e\n\u003cli\u003eMulti-lingual interface\u003c\/li\u003e\n\u003cli\u003eMultiple logging sessions possible without download\u003c\/li\u003e\n\u003cli\u003e0.025% basic DC accuracy\u003c\/li\u003e\n\u003cli\u003e100 kHz AC bandwidth\u003c\/li\u003e\n\u003cli\u003eReal time clock for automatic time stamping of saved readings\u003c\/li\u003e\n\u003cli\u003eTrue RMS AC voltage and current for accurate measurements on complex signals or non-linear loads\u003c\/li\u003e\n\u003cli\u003eAC bandwidth specified to 100 kHz\u003c\/li\u003e\n\u003cli\u003eMeasure up to 10 A (20 A for 30 seconds)\u003c\/li\u003e\n\u003cli\u003e100 mF capacitance range\u003c\/li\u003e\n\u003cli\u003eTemperature function\u003c\/li\u003e\n\u003cli\u003eRelative mode to remove test lead resistance from low ohms or capacitance measurements\u003c\/li\u003e\n\u003cli\u003ePeak capture to record transients as fast as 250 µs\u003c\/li\u003e\n\u003cli\u003eFlukeView forms enable you to document, store and analyze individual readings or a series of measurements, then convert them into professional-looking documents\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434178490453,"sku":"Fluke 287\/FVF\/IR3000","price":706490.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/files\/108801_1663389420.jpg?v=1682749999"},{"product_id":"fluke-27ii-eur-industrial-multimeter-ip67","title":"Fluke 27II\/EUR Industrial multimeter (IP67)","description":"\u003ch2\u003eProduct overview: Fluke 27 II Rugged Digital Multimeter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cstrong\u003eThe standard for rugged\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 27 II Digital Multimeter define a the standard for operating in harsh conditions with the features and accuracy to troubleshoot most electrical problems. Both meters have IP 67 (waterproof and dustproof) rating, MSHA approvals, extended operating temperature range of -15 °C to +55 °C (5 °F to 131 °F, -40 °C for up to 20 minutes) and 95% humidity, and have been designed and tested to withstand a 3 m (10 ft) drop. The Fluke 20 Series Multimeters are built to work in the toughest environments.\u003c\/p\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure up to 1000 V AC and DC\u003c\/li\u003e\n\u003cli\u003eMeasure up to 10 A (20 A for 30 seconds)\u003c\/li\u003e\n\u003cli\u003e10,000 μF capacitance range\u003c\/li\u003e\n\u003cli\u003eFrequency to 200 kHz\u003c\/li\u003e\n\u003cli\u003eExtended AC voltage bandwidth – 40 Hz to 30 kHz\u003c\/li\u003e\n\u003cli\u003eResistance, continuity and diode test\u003c\/li\u003e\n\u003cli\u003eMin\/Max and average recording to capture variations automatically\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 27 II Rugged Digital Multimeter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAccuracy Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC current\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 μA to 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC current\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 μA to 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω to 50 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay counts\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 nF to 9999 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5 Hz to 199.99 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCAT IV 600 V , CAT III 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThree AA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e800 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eBar graph\/backlight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\/Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eData storage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMin\/Max\/Avg\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading hold\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eOther features\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRelative readings (zero)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003eThree AA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"8\"\u003eWarranty and protection\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eSafety rating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600 V\/CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMine safety\u003c\/td\u003e\n\u003ctd\u003eMSHA Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal protection\u003c\/td\u003e\n\u003ctd\u003eRubber holster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop test\u003c\/td\u003e\n\u003ctd\u003e10 feet drop test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDustproof\/waterproof\u003c\/td\u003e\n\u003ctd\u003eYes, IP 67 rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited lifetime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L) with holster\u003c\/td\u003e\n\u003ctd\u003e6.35 x 10.0 x 19.81 cm (2.5 x 3.93 x 7.8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight with holster\u003c\/td\u003e\n\u003ctd\u003e698.5 g (1.54 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434178588757,"sku":"Fluke 27II\/EUR","price":282704.4,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/12_6f1a6e36-f6b0-4718-9b55-34c41e92a4fb.jpg?v=1592229379"},{"product_id":"fluke-28ii-eur-true-rms-industrial-multimeter-ip67","title":"Fluke 28II\/EUR True RMS Industrial multimeter (IP67)","description":"\u003ch2\u003eProduct overview: Fluke 28 II TRMS Rugged IP67 Digital Multimeter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cstrong\u003eThe standard for rugged\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 28 II digital multimeter defines the standard for operating in harsh conditions with the features and accuracy to troubleshoot most electrical problems. The meter offers an IP 67 (waterproof and dustproof) rating, MSHA approvals, extended operating temperature range of -15 °C to +55 °C (5 °F to 131 °F, -40 °C for up to 20 minutes) and 95% humidity, and has been designed and tested to withstand a 3 m (10 ft) drop. The Fluke 28 II Rigged Digital Multimeter is built to work in the toughest environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther key capabilities\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure up to 1000 V AC and DC\u003c\/li\u003e\n\u003cli\u003eMeasure up to 10 A (20 A for 30 seconds)\u003c\/li\u003e\n\u003cli\u003e10,000 μF capacitance range\u003c\/li\u003e\n\u003cli\u003eFrequency to 200 kHz\u003c\/li\u003e\n\u003cli\u003eExtended AC voltage bandwidth– 15 Hz to 20 kHz\u003c\/li\u003e\n\u003cli\u003eBuilt in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument\u003c\/li\u003e\n\u003cli\u003eResistance, continuity and diode test\u003c\/li\u003e\n\u003cli\u003eMin\/Max and average recording to capture variations automatically\u003c\/li\u003e\n\u003cli\u003ePeak min-max\u003c\/li\u003e\n\u003cli\u003eHi resolution 20,000 count display mode\u003c\/li\u003e\n\u003cli\u003eTrue-rms ac voltage and current for accurate measurements on non linear signals\u003c\/li\u003e\n\u003cli\u003eBacklit keypad buttons allow for easy visibility in low-lit areas\u003c\/li\u003e\n\u003cli\u003eLarge display digits and 2 level bright white backlight for increased visibility\u003c\/li\u003e\n\u003cli\u003eReversible holster for added protection when not in use\u003c\/li\u003e\n\u003cli\u003eWithstands hazardous 8,000 volt spikes caused by load switching and faults on industrial circuits and complies with second edition IEC and ANSI electrical safety standards\u003c\/li\u003e\n\u003cli\u003eLong battery life (800 hours)\u003c\/li\u003e\n\u003cli\u003eRelative mode to remove test lead resistance from low ohms measurements\u003c\/li\u003e\n\u003cli\u003eAuto and manual ranging for maximum flexibility\u003c\/li\u003e\n\u003cli\u003eOptional magnetic hanger for easy setup and viewing while freeing your hands for other tasks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cul\u003e\n\u003cli\u003eIP 67 waterproof \u0026amp; dustproof protection, completely sealed for use in harsh environments\u003c\/li\u003e\n\u003cli\u003eDesigned to withstand 3 meter drop (with holster)\u003c\/li\u003e\n\u003cli\u003eUnique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment\u003c\/li\u003e\n\u003cli\u003eMSHA approval\u003c\/li\u003e\n\u003cli\u003eLimited lifetime warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 28 II TRMS Rugged IP67 Digital Multimeter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 503px;\"\u003eAccuracy Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 153px;\"\u003eDC voltage\u003c\/td\u003e\n\u003ctd style=\"width: 166px;\"\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003e0.1 mV to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 166px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003e0.05% + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 153px;\"\u003eAC voltage\u003c\/td\u003e\n\u003ctd style=\"width: 166px;\"\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003e0.1 mV to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 166px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003e0.7% + 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 153px;\"\u003eDC current\u003c\/td\u003e\n\u003ctd style=\"width: 166px;\"\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003e0.1 μA to 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 166px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003e0.2% + 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 153px;\"\u003eAC current\u003c\/td\u003e\n\u003ctd style=\"width: 166px;\"\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003e0.1 μA to 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 166px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003e1.0% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 153px;\"\u003eResistance\u003c\/td\u003e\n\u003ctd style=\"width: 166px;\"\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003e0.1 Ω to 50 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 153px;\"\u003eDisplay counts\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 350px;\"\u003e6000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 153px;\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 350px;\"\u003e1 nF to 9999 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 153px;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 350px;\"\u003e0.5 Hz to 199.99 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 153px;\"\u003eTemperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 350px;\"\u003e-200°C to +1090°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 153px;\"\u003eLow pass filter (Measurement on VSD’s)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 350px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 153px;\"\u003eCompliance\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 350px;\"\u003eCAT IV 600 V , CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 153px;\"\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 350px;\"\u003eIP 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 153px;\"\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 350px;\"\u003eThree AA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 153px;\"\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 350px;\"\u003e800 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 503px;\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 153px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"width: 166px;\"\u003e\u003cb\u003eBar graph\/backlight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003eYes\/Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 153px;\"\u003eData storage\u003c\/td\u003e\n\u003ctd style=\"width: 166px;\"\u003e\u003cb\u003ePeak transient capture\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003e250 μS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 166px;\"\u003eMin\/Max\/Avg\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 166px;\"\u003eReading hold\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 153px;\"\u003eOther features\u003c\/td\u003e\n\u003ctd style=\"width: 166px;\"\u003e\u003cb\u003eRelative readings (zero)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 166px;\"\u003eBattery type\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003eThree AA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"8\" style=\"width: 153px;\"\u003eWarranty and protection\u003c\/td\u003e\n\u003ctd style=\"width: 166px;\"\u003e\u003cb\u003eSafety rating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003eCAT IV 600 V\/CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 166px;\"\u003eMine safety\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003eMSHA Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 166px;\"\u003eExternal protection\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003eRubber holster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 166px;\"\u003eDrop test\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003e10 feet drop test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 166px;\"\u003eDustproof\/waterproof\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003eYes, IP 67 rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 166px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003eLimited lifetime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 166px;\"\u003eSize (H x W x L) with holster\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003e6.35 x 10.0 x 19.81 cm (2.5 x 3.93 x 7.8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 166px;\"\u003eWeight with holster\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003e698.5 g (1.54 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434178621525,"sku":"Fluke 28II\/EUR","price":300999.6,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/fluke_28_ii_trms_industrial_multimeter_with_ip67_rating.jpg?v=1599486865"},{"product_id":"fluke-8808a-su-240v-5-5-digit-multimeter-software-cable","title":"Fluke 8808A\/SU 240V 5.5 Digit multimeter (software \u0026 cable)","description":"\u003cp\u003e8808A\/SU 240V 8808A\/SU 240V, 5.5 DIGIT PRECISION MULTIMETER, SW \u0026amp; CABLE\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 8808A\/SU 5.5 Digit Multimeter (software \u0026amp; cable) is an easy to use, versatile meter. It has a 5.5 digit resolution, basic V dc accuracy of 0.015% and 2x4 ohms 4-wire measurement technique.\u003c\/span\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434179047509,"sku":"Fluke 8808A\/SU 240V","price":580800.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/51_2e567996-4db0-47b4-9bac-13a81cab760c.jpg?v=1592314896"},{"product_id":"fluke-ib376m-376-fc-5-screwdrivers-bundle-isls3-isls5-iphs2-iphs1-isls8","title":"Fluke  IB376M 376 FC   5 screwdrivers Bundle ISLS3 ISLS5 IPHS2 IPHS1 ISLS8","description":"\u003cp\u003eIB376M  IB376M,376 FC + 5 SCREWDRIVERS BUNDLE ISLS3+ISLS5+IPHS2+IPHS1+ISLS8\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434180456533,"sku":"Fluke IB376M","price":311454.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/2054_1_k.jpg?v=1598878708"},{"product_id":"fluke-353-ac-dc-true-rms-clamp-meter","title":"Fluke 353 AC\/DC True RMS Clampmeter","description":"\u003cp\u003eFLUKE-353 FLUKE-353,AC\/DC TRMS CLAMP METER,2000A,AMPS ONLY\u003c\/p\u003e\n\u003ch2\u003eProduct overview: Fluke 353 True RMS 2000 A Clamp Meter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile and rugged tool for applications with high currents\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConfidently take reliable readings with the True RMS, Fluke 353 digital clamp meter; the tools of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.\u003c\/p\u003e\n\u003cp\u003eAccurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads.\u003c\/p\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cul\u003e\n\u003cli\u003eReliably handle a wide range of high-current applications with 2000 A AC + DC true-rms, 1400 A ac, and 2000 A DC\u003c\/li\u003e\n\u003cli\u003eThe large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V, CAT III 1000 V rating for added user protection\u003c\/li\u003e\n\u003cli\u003eIn-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability\u003c\/li\u003e\n\u003cli\u003eAccurately measure frequency up to 1 kHz for optimum troubleshooting\u003c\/li\u003e\n\u003cli\u003eQuickly analyze readings using the MIN, MAX, and AVG functions\u003c\/li\u003e\n\u003cli\u003eA large backlit display allows for easy visibility in low-lit areas\u003c\/li\u003e\n\u003cli\u003eUse the display hold feature to capture readings even when the display cannot be viewed\u003c\/li\u003e\n\u003cli\u003eUse the low-pass filter to smooth out noisy loads and stabilize readings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eSpecifications: Fluke 353 True RMS 2000 A Clamp Meter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eElectrical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\" width=\"25%\"\u003eCurrent measurement DC and AC 10 Hz to 100 Hz\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A \/ 400 A \/ 2000 A \/ 1400 AC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e10 mA \/ 100 mA \/ 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eA: 1.5% rdg + 15 digits\u003cbr\u003eA: 1.5% rdg + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger level for Inrush\u003c\/td\u003e\n\u003ctd\u003e0.50 A \/ 5.0 A \/ 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger level for Hz filter OFF\u003c\/td\u003e\n\u003ctd\u003e2.50 A \/ 2.5 A \/ 8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger level for Hz filter ON\u003c\/td\u003e\n\u003ctd\u003e0.50 A \/ 2.5 A \/ 8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eCrest Factor (50\/60 Hz)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A \/ 400 A \/ 2000 A \/ 1400 AC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2 @ 33 A, 2.4 @ 27 A\u003cbr\u003e2 @ 330 A, 2.4 @ 270 A\u003cbr\u003e2 @ 1000 A, 2.4 @ 833 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eCurrent measurement AC 100.1 Hz to 1 kHz\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A \/ 400 A \/ 2000 A; 1400 AC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e10 mA \/ 100 mA \/ 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e10 A: 3.5% rdg + 15 digits\u003cbr\u003e10 A: 3.5% rdg + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger level for Inrush\u003c\/td\u003e\n\u003ctd\u003e0.50 A \/ 5.0 A \/ 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger level for Hz filter OFF\u003c\/td\u003e\n\u003ctd\u003e2.50 A \/ 2.5 A \/ 8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger level for Hz filter ON\u003c\/td\u003e\n\u003ctd\u003e0.50 A \/ 2.5 A \/ 8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eFrequency measurement\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMeasurement range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0 Hz to 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy – 5.0 Hz to 100 Hz\u003c\/td\u003e\n\u003ctd\u003e0.2% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy – 100.1 Hz to 1 kHz\u003c\/td\u003e\n\u003ctd\u003e0.5% + 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger level\u003c\/td\u003e\n\u003ctd\u003eRefer to current and voltage tables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"5\"\u003e1. Add 2% to error spec for CF \u0026gt; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eSix 1.5 V AA NEDA 15 A or IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life (with typical usage, backlight off)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e100 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest leads\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eRated to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e.814 kg (1.8 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw size\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e58 mm (2.28 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x D)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e300 x 98 x 52 mm (12 x 3.75 x 2 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety rating\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eIEC 61010-2-032, 600 V CAT IV, 1000 V CAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e32°F to +122°F (0°C to +50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e-4°F to 140°F (-20°C to +60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0 to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e10,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e42 (indoor use only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop test requirements\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMI, RFI, EMC\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eFCC part 15, IEC\/EN 61326-1:1997 class B\u003cbr\u003eIEC\/EN 61326:1997 3V\/m, performance criteria B, EN61325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature coefficients\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eCurrent\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1% of reading per °C outside 22°C to 24°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e0.1% of reading per °C outside 22°C to 24°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434181406805,"sku":"Fluke 353","price":403801.2,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/21a.jpg?v=1592232604"},{"product_id":"fluke-365-detachable-trms-clamp-meter","title":"Fluke 365 Detachable TRMS Clampmeter","description":"\u003cp\u003eFLUKE-365\/E FLUKE-365\/E,DETACHABLE 200A TRMS AC\/DC CLAMP\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eProduct overview: Fluke 365 Detachable Jaw True RMS AC\/DC Clamp Meter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cstrong\u003eBe ready for anything.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 365 is a rugged meter perfect for jobs where access to wires is difficult. The 365’s thin, small jaw is detachable with a flexible lead, which makes gaining access to wires and viewing the display easier than ever.\u003c\/p\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cul\u003e\n\u003cli\u003e200 A AC and DC current measurement with detachable jaw\u003c\/li\u003e\n\u003cli\u003e600 VAC and DC voltage measurement\u003c\/li\u003e\n\u003cli\u003eDetachable jaw makes accessing wires and viewing the display easier\u003c\/li\u003e\n\u003cli\u003eBuilt in flashlight\/torch allows for easy illumination and identification of wires\u003c\/li\u003e\n\u003cli\u003eCAT III 600 V\u003c\/li\u003e\n\u003cli\u003eCompact design fits in your hand and can be used while wearing protective equipment\u003c\/li\u003e\n\u003cli\u003eState of the art signal processing allows for use in noisy electrical environments while providing stable readings\u003c\/li\u003e\n\u003cli\u003eLarge, easy to read, backlight display automatically sets the correct measurement range so you do not need to change switch positions while taking a measurement\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e﻿\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications: Fluke 365 Detachable Jaw True RMS AC\/DC Clamp Meter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eElectrical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAC Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e200.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2 % ±5 digits (45 – 65 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2.5 % ±5 digits (65 – 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCrest Factor\u003c\/td\u003e\n\u003ctd\u003e2.5 @ 125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.55 @ 200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdd 2 % for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDC Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e200.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2 % ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5 % ±5 digits (45 – 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1 % ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eResistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600.0 Ω\/6000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\/1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1 % ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eMechanical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e225 x 65 x 46 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e225 x 65 x 46 mm\u003c\/td\u003e\n\u003ctd\u003e275 g (including batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw Opening\u003c\/td\u003e\n\u003ctd\u003e18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetachable Jaw Cable Length\u003c\/td\u003e\n\u003ctd\u003e900 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 °C to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003eNon condensing (\u0026lt;10 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e≤90 % RH (at 10 °C to 30 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e≤75 % RH (at 30 °C to 40 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e≤45 % RH (at 40 °C to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e(Without Condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Altitude\u003c\/td\u003e\n\u003ctd\u003e12,000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficients\u003c\/td\u003e\n\u003ctd\u003e0.1 x(specified accuracy)\/ °C (\u0026lt;18 °C or \u0026gt; 28 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eANSI\/ISA S82.02.01:2004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAN\/CSA-C22.2 No. 61010-1-04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL 61010-1:2004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEN\/IEC 61010-1:2001 to 600V CAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd\u003e2 AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434181472341,"sku":"Fluke 365","price":152895.6,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/f-365-01b-1500x1000.jpg?v=1598886467"},{"product_id":"fluke-368-fc-wireless-leakage-current-clamp-40mm-jaw","title":"Fluke 368 FC Wireless leakage current clamp, 40mm jaw","description":"\u003cp\u003eFLUKE-368 FC FLUKE-368 FC,WIRELESS LEAKAGE CURRENT CLAMP METER, 40MM JAW\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e﻿\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4\u003eFluke 368 FC Offers\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS measurements for accuracy when measuring complex, non-sinusoidal waveforms\u003c\/li\u003e\n\u003cli\u003e1.6\" (40 mm) jaw opening\u003c\/li\u003e\n\u003cli\u003eHighest resolution of 1 µA, measure up to 60 A\u003c\/li\u003e\n\u003cli\u003eSelectable filter function removes unwanted noise\u003c\/li\u003e\n\u003cli\u003eMax\/Min\/Average readings and hold function\u003c\/li\u003e\n\u003cli\u003eForward-facing LED work light for use in dark wiring cabinets\u003c\/li\u003e\n\u003cli\u003eBacklit display; auto backlight off and auto power off for extended battery life\u003c\/li\u003e\n\u003cli\u003eInternal Memory Logging: up to 65,000 measurement points\u003c\/li\u003e\n\u003cli\u003eCAT III 600 V safety rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eReduce downtime - find leakage currents without taking equipment offline\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis True RMS leakage current clamp meter helps users detect, document, record, and compare leakage current readings over time as a means of preventing unplanned downtime, and identifying intermittent GFCI and RCD trips, all without taking equipment offline.\u003c\/p\u003e\n\u003cp\u003eIt features a large 1.6\" (40 mm) diameter jaw for work with large conductors. The jaw is fully shielded to capture very small leakage signals and minimize external electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eAlso, this product offers wireless data connectivity via Fluke Connect, which enables you to track changes in leakage current over time, helping you to identify potential problems before they turn into major failures.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eFluke 368 FC Specifications\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eElectrical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Function\u003c\/td\u003e\n\u003ctd\u003eAlternating current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Ampere Range\u003c\/td\u003e\n\u003ctd\u003e3, 30, 300 mA\u003cbr\u003e3, 30, 60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange Selection\u003c\/td\u003e\n\u003ctd\u003emA\/A: Manual selection\u003cbr\u003e3\/30\/300 mA: Automatic selection\u003cbr\u003e3\/30\/60 A: Automatic selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\/Resolution\u003c\/td\u003e\n\u003ctd\u003e3\/0.001 mA\u003cbr\u003e30\/0.01 mA\u003cbr\u003e300\/0.1 mA\u003cbr\u003e3\/0.001 A\u003cbr\u003e30\/0.01 A\u003cbr\u003e60\/0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy - Filter Activated (40 to 70 Hz), Filter Off (40 to 1 kHz)\u003c\/td\u003e\n\u003ctd\u003e3 mA to 30 A: 1% + 5 digits\u003cbr\u003e60 A: 2% + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e40 Hz to 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay (LCD)\u003c\/td\u003e\n\u003ctd\u003eDigital readout: 3300 count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Refresh Rate\u003c\/td\u003e\n\u003ctd\u003e4 times\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Conductor Diameter\u003c\/td\u003e\n\u003ctd\u003e1.6\" (40 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e2 x AA, IEC LR6, NEDA 15A, alkaline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003eExpected battery life, without using backlight and spotlight, is more than 150 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Down\u003c\/td\u003e\n\u003ctd\u003eMeter automatically shuts down after 15 minutes of inactivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e14 to 122°F (-10 to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 140°F (-40 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003eNon-condensing at \u0026lt;50°F (\u0026lt;10°C)\u003cbr\u003e90% relative humidity at 50 to 86°F (10 to 30°C)\u003cbr\u003e75% relative humidity at 86 to 104°F (30 to 40°C)\u003cbr\u003e45% relative humidity at 104 to 122°F (40 to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e6561.7' (2000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Altitude\u003c\/td\u003e\n\u003ctd\u003e39,370.1' (12,000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e9.2 x 4 x 1.8\" (234 x 101 x 46 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.1 lbs (500 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eSafety Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral Safety\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1: Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Safety\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-2-032: CAT III 600 V\/CAT IV 300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Sensor Action Category\u003c\/td\u003e\n\u003ctd\u003eIEC 61557-13: Class 2, ≤30 A\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434181570645,"sku":"Fluke 368 FC","price":388119.6,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/23_090832f2-d00b-49e3-a5a2-9bd3110ae858.jpg?v=1592233993"},{"product_id":"fluke-373-600a-trms-clamp-meter","title":"Fluke 373 600A TRMS Clampmeter","description":"\u003cp\u003eFLUKE-373\/E FLUKE-373\/E,600A TRMS AC CLAMP METER\u003c\/p\u003e\n\u003ch2\u003eProduct overview: Fluke 373 True-RMS AC Clamp Meter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 373 True RMS AC Clamp Meter does the job for any AC-only current measurement application\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFluke 373 True-RMS AC Clamp Meter is a great choice for AC-only current measurement situations. Featuring True RMS AC voltage and current measurements you can measure AC current to 600 A and AC voltage to 600V. The 373 also measures DC voltage to 600 V and resistance to 6000 Ω.\u003c\/p\u003e\n\u003cp\u003eTo make it even easier to use, the large, easy-to-read backlit display provides better visibility in dimly lit conditions. And the 373 automatically sets the correct measurement range based on the voltage present when you power up, so you do not need to move the switch while taking a measurement. When you put it all together, you’ll find the Fluke 373 offers everything you need, plus a little more.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful capabilities:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProvides True-RMS voltage and current measurements to accurately measure non-linear signals\u003c\/li\u003e\n\u003cli\u003eAutomatically selects a measurement range based on voltage present so you don’t need to change the switch positions while taking a measurement\u003c\/li\u003e\n\u003cli\u003ePresents readings on a large, easy-to-read backlit display\u003c\/li\u003e\n\u003cli\u003eFeatures CAT IV 300 V, CAT III 600 V safety ratings\u003c\/li\u003e\n\u003cli\u003eComes with a soft carrying case and three-year warranty\u003c\/li\u003e\n\u003cli\u003eRuns on two AA alkaline batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003eA top performing True-RMS current clamp for AC-only current measurements to 600 A\u003c\/li\u003e\n\u003cli\u003eMeasures AC and DC voltage to 600 V\u003c\/li\u003e\n\u003cli\u003eMeasures resistance to 6000 Ω with continuity detection\u003c\/li\u003e\n\u003cli\u003eOffers state of the art signal processing to provide stable readings even in noisy electrical environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 373 True-RMS AC Clamp Meter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eElectrical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAC Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2 % ± 5 digits (48 – 62 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor (50\/60 Hz)\u003c\/td\u003e\n\u003ctd\u003e2.5 @ 600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eAC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0 % ± 5 digits (48 – 62 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eDC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1 % ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eResistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600.0 Ω\/6000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\/1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1 % ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Beeper\u003c\/td\u003e\n\u003ctd\u003e30 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eCapacitance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e10.0 – 100.0 μF \/ 1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 μF\/1 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.9 % ± 2 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMechanical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd\u003e232 mm x 85 mm x 45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e370 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 °C to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003eNon condensing (\u0026lt; 10 °C)\u003cbr\u003e≤ 90 % RH (at 10 °C to 30 °C)\u003cbr\u003e≤ 75 % RH (at 30 °C to 40 °C)\u003cbr\u003e≤ 45 % RH (at 40 °C to 50 °C)\u003cbr\u003e(Without Condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e3000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Altitude\u003c\/td\u003e\n\u003ctd\u003e12,000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMI, EMC\u003c\/td\u003e\n\u003ctd\u003eMeets all applicable requirements in EN61326-1:2006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficients\u003c\/td\u003e\n\u003ctd\u003eAdd 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eANSI\/ISA S82.02.01:2004\u003cbr\u003eCAN\/CSA-C22.2 No. 61010-1-04\u003cbr\u003eIEC\/EN 61010-1:2001, 600V CAT III, 300V CAT IV\u003cbr\u003ePollution Degree 2\u003cbr\u003eEN\/IEC 61010-2-32:2002\u003cbr\u003eEN\/IEC 61010-031:2002\/A1:2008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd class=\"certifications\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd\u003e2 AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434181636181,"sku":"Fluke 373","price":132422.4,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/112_2ba72d75-9405-40fd-b1b2-1e2179521b00.jpg?v=1592299311"},{"product_id":"fluke-381-remote-display-trms-clamp-meter","title":"Fluke 381 Remote Display TRMS Clamp Meter","description":"\u003ch2\u003eProduct overview: Fluke 381 Remote Display True RMS AC\/DC Clamp Meter with iFlex®\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cstrong\u003eWhat Once Took Two People, Now Takes One\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNow one technician can do jobs that would otherwise require two people. Clamp the Fluke 381 around a conductor, remove the display and walk across the room to operate controls or remove protective equipment, all while watching real-time readings.\u003c\/p\u003e\n\u003cp\u003eThe iFlex® Flexible Current Probe (included) expands the measurement range to 2500 A AC while providing increased display flexibility. With a cord that runs 6 feet, you can finally measure those tight spaces, awkward sized conductors and disorganized wires.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cul\u003e\n\u003cli\u003eWireless technology allows the display to be carried up to 30 ft. away from the point of measurement for added flexibility without interference with measurement accuracy\u003c\/li\u003e\n\u003cli\u003eThe removable magnetic display can be conveniently mounted where it is easily seen\u003c\/li\u003e\n\u003cli\u003eiFlex® Flexible Current Probe expands the measurement range to 2500 A AC\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V, CAT III 1000 V\u003c\/li\u003e\n\u003cli\u003eIntegrated low pass filter and state-of-the-art signal processing allows for use in noisy electrical environments while providing stable readings\u003c\/li\u003e\n\u003cli\u003eProprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it\u003c\/li\u003e\n\u003cli\u003eErgonomic design fits in your hand and can be used while wearing protective equipment\u003c\/li\u003e\n\u003cli\u003eRadio transmitter automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Conformance\u003c\/strong\u003e\u003cbr\u003eIEC\/EN 61010-1:2001, 1000V CAT III, 600V CAT IV\u003c\/p\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications: Fluke 381 Remote Display True RMS AC\/DC Clamp Meter with iFlex®\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eElectrical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eAC Current via Jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2% ± 5 digits (10-100 Hz)\u003cbr\u003e5% ± 5 digits (100-500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor (50\/60 Hz)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e3 @ 500 A\u003cbr\u003e2.5 @ 600 A\u003cbr\u003e1.42 @ 1000 A\u003cbr\u003eAdd 2% for C.F. \u0026gt; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eAC Current via Flexible Current Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e999.9 A \/ 2500 A (45 Hz – 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 A \/ 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e3% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor (50\/60 Hz)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e3.0 at 1100 A\u003cbr\u003e2.5 at 1400 A\u003cbr\u003e1.42 at 2500 A\u003cbr\u003eAdd 2% for C.F. \u0026gt; 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003ePosition Sensitivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003e\u003cimg alt=\"Flexible current probe\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/37x_position_sens_100x181.png\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u003cb\u003eDistance from Optimum\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei2500-10 Flex\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei2500-18 Flex\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eError\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eA\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 in (12.7 mm)\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd\u003e±0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eB\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 in (20.3 mm)\u003c\/td\u003e\n\u003ctd\u003e2.0 in (50.8 mm)\u003c\/td\u003e\n\u003ctd\u003e±1.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eC\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 in (35.6 mm)\u003c\/td\u003e\n\u003ctd\u003e2.5 in (63.5 mm)\u003c\/td\u003e\n\u003ctd\u003e±2.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"5\"\u003eMeasurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eDC Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eAC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e600 V \/1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 V \/ 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1.5% ± 5 digits (20 – 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eDC Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e600.0 V \/1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 V \/ 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eFrequency – Via Jaw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e5.0 – 500.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.5% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger Level\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e5 – 10 Hz, ≥ 10 A\u003cbr\u003e10 – 100 Hz, ≥ 5 A\u003cbr\u003e100 – 500 Hz, ≥ 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eFrequency via Flexible Current Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e5.0 to 500.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.5% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger Level\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e5 to 20 Hz, ≥ 25 A\u003cbr\u003e20 to 100 Hz, ≥ 20 A\u003cbr\u003e100 to 500 Hz, ≥ 25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eResistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e600 Ω\/6 kΩ\/60 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 Ω\/1 Ω\/10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eMechanical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x H)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e277 x 88 x 43 mm (55 mm for remote unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e350 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw Opening\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible Current Probe Diameter\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e7.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible Current Probe Cable Length\u003cbr\u003e(head to electronics connector)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1.8 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eNon condensing (\u0026lt; 10°C)\u003cbr\u003e≤ 90% RH (at 10°C to 30°C)\u003cbr\u003e≤ 75% RH (at 30°C to 40°C)\u003cbr\u003e≤ 45% RH (at 40°C to 50°C)\u003cbr\u003e(Without Condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2,000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Altitude\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e12,000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMI, RFI, EMC, RF\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eEN 61326-1:2006, EN 61326-2-2:2006\u003cbr\u003eETSI EN 300 328 V1.7.1:2006\u003cbr\u003eETSI EN 300 489 V1.8.1:2008\u003cbr\u003eFCC Part 15 Subpart C Sections 15.207, 15.209, 15.249\u003cbr\u003eFCCID: T68-F381\u003cbr\u003eRSS-210 IC: 6627A-F381\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficients\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eAdd 0.1 x specified accuracy for each degree C above 28°C or below 18°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWireless Frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2.4 GHz ISM Band 10 meter range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eANSI\/ISA S82.02.01:2004\u003cbr\u003eCAN\/CSA-C22.2 No. 61010-1-04\u003cbr\u003eIEC\/EN 61010-1:2001 to 1000V CAT III, 600V CAT IV.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble Insulation Clearance\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003ePer IEC 61010-2-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDouble Insulation Creepage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003ePer IEC 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434181898325,"sku":"Fluke 381","price":332362.8,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/5_08598913-ab36-4804-a05e-5e8811a6f4a2.jpg?v=1592305056"},{"product_id":"fluke-t90-voltage-continuity-tester","title":"Fluke T90 Voltage\/continuity tester","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eProduct overview: Fluke T90 Two-pole Voltage and Continuity Electrical Tester\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cstrong\u003eFluke T90 Basic Voltage and Continuity Tester\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe compact Fluke T90 electrical tester gives you fast test results the way you need them in a slim design. This electrical tester has large, easy-to-use buttons, bright backlit LED indicators. A clear audible indicator give quick results in any work situation.\u003c\/p\u003e\n\u003cp\u003eThis voltage tester is the perfect basic tool to check the presence of voltage.\u003c\/p\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv aria-expanded=\"true\" data-readmore=\"\" id=\"keyfeature_content\"\u003e\n\u003cp\u003eFluke T90 electrical tester is the basic voltage and continuity tester for troubleshooting\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasy to Use: this circuit tester has large, easy-to-use buttons\u003c\/li\u003e\n\u003cli\u003eDesigned according to IEC EN 61243-3:2014 to verify the absence of voltage – even with discharged batteries\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V, CAT III 690 V safety rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke T90 Two-pole Voltage and Continuity Electrical Tester\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cp\u003eThe complete family of Fluke Two-Pole Voltage and Continuity testers lets you choose the features, functions, and price\/performance to fit your applications and preferences.\u003c\/p\u003e\n\u003ch3\u003eFluke voltage and continuity tester selection guide\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 40%;\"\u003eFeatures\u003c\/th\u003e\n\u003cth style=\"width: 12%;\"\u003eT150\u003c\/th\u003e\n\u003cth style=\"width: 13%;\"\u003eT130\u003c\/th\u003e\n\u003cth style=\"width: 11.6421%;\"\u003eT110\u003c\/th\u003e\n\u003cth style=\"width: 9.35791%;\"\u003eT90\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003eBacklit LED indicator\u003c\/td\u003e\n\u003ctd style=\"width: 12%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 13%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.6421%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 9.35791%;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003eBacklit LCD digital display\u003c\/td\u003e\n\u003ctd style=\"width: 12%;\"\u003eLCD\u003c\/td\u003e\n\u003ctd style=\"width: 13%;\"\u003eLCD\u003c\/td\u003e\n\u003ctd style=\"width: 11.6421%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 9.35791%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003eContinuity test—visual results\u003c\/td\u003e\n\u003ctd style=\"width: 12%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 13%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.6421%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 9.35791%;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003eContinuity test—audible results\u003c\/td\u003e\n\u003ctd style=\"width: 12%;\"\u003e•\u003cbr\u003ewith on\/off\u003c\/td\u003e\n\u003ctd style=\"width: 13%;\"\u003e•\u003cbr\u003ewith on\/off\u003c\/td\u003e\n\u003ctd style=\"width: 11.6421%;\"\u003e•\u003cbr\u003ewith on\/off\u003c\/td\u003e\n\u003ctd style=\"width: 9.35791%;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003eVibratory indicator under load\u003c\/td\u003e\n\u003ctd style=\"width: 12%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 13%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.6421%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 9.35791%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003eDisplay hold\u003c\/td\u003e\n\u003ctd style=\"width: 12%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 13%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.6421%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 9.35791%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003eVoltage test\u003c\/td\u003e\n\u003ctd style=\"width: 12%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 13%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.6421%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 9.35791%;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003eIndication of polarity\u003c\/td\u003e\n\u003ctd style=\"width: 12%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 13%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.6421%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 9.35791%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003eResistance measurement\u003c\/td\u003e\n\u003ctd style=\"width: 12%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 13%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 11.6421%;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 9.35791%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003eSwitchable load\u003c\/td\u003e\n\u003ctd style=\"width: 12%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 13%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.6421%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 9.35791%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003eSingle pole test for phase detection\u003c\/td\u003e\n\u003ctd style=\"width: 12%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 13%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.6421%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 9.35791%;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003eRotary field indicator\u003c\/td\u003e\n\u003ctd style=\"width: 12%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 13%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.6421%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 9.35791%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003eProbe tip protection\u003c\/td\u003e\n\u003ctd style=\"width: 12%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 13%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.6421%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 9.35791%;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003eVoltage detection with discharged batteries\u003c\/td\u003e\n\u003ctd style=\"width: 12%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 13%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.6421%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 9.35791%;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003eElectrical torch function\u003c\/td\u003e\n\u003ctd style=\"width: 12%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 13%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.6421%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 9.35791%;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 40%;\"\u003eWear indicator test lead wire\u003c\/td\u003e\n\u003ctd style=\"width: 12%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 13%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 11.6421%;\"\u003e•\u003c\/td\u003e\n\u003ctd style=\"width: 9.35791%;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434182357077,"sku":"Fluke T90","price":33976.8,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/3e.jpg?v=1592323091"},{"product_id":"fluke-sm100-socket-tester","title":"Fluke SM100 Socket Tester","description":"\u003cp\u003eFLUKE-SM100 FLUKE-SM100,SOCKETMASTER\u003c\/p\u003e\n\u003cdiv class=\"panel-pane pane-block pane-igcommerce-utility-articles-articles-solr-title pane-igcommerce-utility-articles\"\u003e\n\u003cdiv class=\"pane-content\"\u003e\n\u003ch1 itemprop=\"headline\"\u003eFluke SM100, SM200 and SM300 Electrical Socket Testers Voluntary Recall\u003c\/h1\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel-separator\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"panel-pane pane-block pane-igcommerce-utility-articles-articles-solr-desc pane-igcommerce-utility-articles\"\u003e\n\u003cdiv class=\"pane-content\"\u003e\n\u003cdiv itemprop=\"articleBody\"\u003e\n\u003cp\u003eDear Fluke Customer:\u003c\/p\u003e\n\u003cp\u003eFluke Corporation has identified a safety issue concerning the Fluke SM100, SM200 and SM300 Electrical Socket Testers. As a precautionary measure, Fluke has decided to voluntarily recall all of these products and provide affected customers with free replacement products.\u003c\/p\u003e\n\u003cp\u003eWe are sorry for any inconvenience this might cause you, but we hope that you'll understand that consumer safety is our utmost priority.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe following models are being voluntarily recalled:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFluke Part number\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLUKE-SM100\u003c\/td\u003e\n\u003ctd\u003eSocket Master Tester\u003c\/td\u003e\n\u003ctd\u003e2406958\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLK-STU-KIT\u003c\/td\u003e\n\u003ctd\u003eFluke Student Kit\u003c\/td\u003e\n\u003ctd\u003e4918301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eROBIN-SM100\u003c\/td\u003e\n\u003ctd\u003eSocket Master\u003c\/td\u003e\n\u003ctd\u003e2072250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eROBIN-SM200\u003c\/td\u003e\n\u003ctd\u003eSocket Master Plus\u003c\/td\u003e\n\u003ctd\u003e2072261\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLUKE-SM200\u003c\/td\u003e\n\u003ctd\u003eSocket Master Plus\u003c\/td\u003e\n\u003ctd\u003e2406964\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eROBIN-SM300\u003c\/td\u003e\n\u003ctd\u003eSocket Master Tester\u003c\/td\u003e\n\u003ctd\u003e2072277\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLUKE-SM300\u003c\/td\u003e\n\u003ctd\u003eSocket Master Advanced\u003c\/td\u003e\n\u003ctd\u003e2406973\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDescription of the problem\u003c\/h2\u003e\n\u003cp\u003eThe primary function of the SM100, SM200, and SM300 Socket Testers is to detect the presence of an open ground in a socket outlet. Socket outlets are often installed in metal boxes and have exposed metal parts connected to the earth pin of the socket.\u003c\/p\u003e\n\u003cp\u003eIf the Socket Tester detects a missing earth condition, shown on the tester as\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e●\u003c\/span\u003e○○, the internal circuitry will source a voltage from the phase conductor onto the earth pin of the socket outlet, as well as any metal parts connected to the earth pin of the socket.\u003c\/p\u003e\n\u003cp\u003eSuch a condition can result in an electric shock to the user. The current level is probably not life threatening in most cases but could be painful and may be sufficient to knock a person down or off a ladder.\u003c\/p\u003e\n\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/sm100_fault_v2_222X200.jpg\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/robin_in-wall235X200.jpg\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434182488149,"sku":"Fluke SM100","price":14810.4,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/47_ccd4e570-5426-4a1b-b343-edca9727094c.jpg?v=1592313755"},{"product_id":"fluke-lvd1-volt-light","title":"Fluke  LVD1 Volt Light","description":"\u003cp\u003eLVD1A LVD1A,VOLT LIGHT EU ROHS\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eNon-contact AC voltage detector and LED flashlight combined in one convenient, compact design. With exclusive dual-sensitivity. The voltage detector glows blue when it's near AC voltage, and glows red when it's at the source. Detects voltages from 40 V AC to 300 V AC. Voltage detector glows blue 50 Hz - 60 Hz or 2.5 - 38 cm (1 - 5 in) away from source. Operating temperature 0 °C to 50 °C. Ultra-bright white LED with 100,000 hour bulb life. AAA battery included.\u003c\/span\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434182717525,"sku":"Fluke LVD1","price":16988.4,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/72_e9b63801-884a-4583-8a10-b5d061cecf13.jpg?v=1591799327"},{"product_id":"fluke-lvd2-volt-light","title":"Fluke  LVD2 Volt Light","description":"\u003cp\u003eLVD2 LVD2,VOLT LIGHT\u003c\/p\u003e\n\u003ch2\u003eProduct overview: Fluke LVD2 Non-Contact Voltage Tester\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cstrong\u003eFluke LVD2 Volt Light detects voltage without contact\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLVD2 volt light, offered by Fluke combines a non-contact AC voltage detector and LED flashlight into one easy to use pen-style design. It features dual sensitivity detection, turning blue from 1” to 5” (2.54 cm to 12.7 cm) from the source and red when at the source. The LVD2 is a CAT IV 600 V rated and is suitable for commercial and industrial applications.\u003c\/p\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cul\u003e\n\u003cli\u003eNon-contact AC voltage tester and LED flashlight\u003c\/li\u003e\n\u003cli\u003eDetects from 90 to 600 V AC\u003c\/li\u003e\n\u003cli\u003eFeatures dual-sensitivity for two levels of detection\u003c\/li\u003e\n\u003cli\u003eIndicates proximity to AC voltage source with blue light\u003c\/li\u003e\n\u003cli\u003eIndicates you’re at the source with red light\u003c\/li\u003e\n\u003cli\u003eUltra-bright white LED light with 100,000-hour bulb life\u003c\/li\u003e\n\u003cli\u003eSafety rated to CAT IV 600 V\u003c\/li\u003e\n\u003cli\u003eOperating temperature 0°C to 50°C\u003c\/li\u003e\n\u003cli\u003eAAA battery included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434182750293,"sku":"Fluke LVD2","price":23086.8,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/71_3ff22763-5bb9-4d42-b3d5-15849c74674b.jpg?v=1591799106"},{"product_id":"fluke-flk2ac-200-1000vcl-acv-detector-200-1000v","title":"Fluke  FLK2AC\/200-1000VCL ACV Detector 200-1000V","description":"\u003cp\u003eProduct overview: Fluke 2AC Non-Contact Voltage Tester\u003c\/p\u003e\n\u003cp\u003eAlways on for faster, safer voltage testing\u003c\/p\u003e\n\u003cp\u003eThe Fluke 2AC is the latest addition to the VoltAlert™ AC non-contact voltage tester family. It is designed to be pocket-sized and easy to use. The tip of the pocket-sized tester will glow red when within close proximity of an outlet, terminal strip, or power cord where voltage is present. The 2 AC is always on, with a battery check function to make sure the tester is working properly. *\u003c\/p\u003e\n\u003cp\u003eYour first-choice tool for go\/no-go testing\u003c\/p\u003e\n\u003cp\u003eThe 2AC tests for energized circuits and defective grounds, whether it's for an electrician on the factory floor or the do-it-yourselfer around the house.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCAT IV 1000 V overvoltage rated product for best in class user protection\u003c\/li\u003e\n\u003cli\u003eSuitable for a wide range of residential, commercial and industrial needs\u003c\/li\u003e\n\u003cli\u003eFluke ruggedness and reliability with a two-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* Use of Battery Check function is optional and for convenience only, it is not intended as a substitute for checking the unit on a known live source before and after use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNon-contact voltage detection from 90 to 1000 V AC\u003c\/li\u003e\n\u003cli\u003eInnovative 'Battery Check' ensures battery is in good condition*\u003c\/li\u003e\n\u003cli\u003eIntegrated clip design, optimized for pocket storage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 2AC Non-Contact Voltage Tester\u003c\/h2\u003e\n\u003ctable style=\"width: 534px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 518px;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\n\u003cp\u003eOperating Principles\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 367px;\"\u003e\n\u003cp\u003eSenses the steady state electrostatic ﬁeld produced by AC voltage through insulation without requiring contact to the bare conductor. A red glow at the tip indicates the presence of voltage.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\n\u003cp\u003eSafety Compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 367px;\"\u003e\n\u003cp\u003eMeets IEC 61010-1:2001, UL 61010-1 (2nd ed.), CAN\/CSA-C22.2 No. 61010-1-04, and ISA-82.02.01 Pollution Degree 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\n\u003cp\u003eEMC Compliance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 367px;\"\u003e\n\u003cp\u003eMeets IEC 61326-1:2006\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\n\u003cp\u003eOperating\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 367px;\"\u003e\n\u003cp\u003e90 V AC to 1000 V AC, CAT IV 1000 V rated\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\n\u003cp\u003eTemperature (Operating and Storage)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 367px;\"\u003e\n\u003cp\u003e-10°C to 50°C (-14°F to 122°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 151px;\"\u003e\n\u003cp\u003eOperating Humidity Ranges\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 367px;\"\u003e\n\u003cp\u003e0% to 95% (0°C to 30°C)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 367px;\"\u003e\n\u003cp\u003e0% to 75% (30°C to 40°C)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 367px;\"\u003e\n\u003cp\u003e0% to 45% (40°C to 55°C)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\n\u003cp\u003eAltitude\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 367px;\"\u003e\n\u003cp\u003e2000 m (CAT IV 1000 V)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\n\u003cp\u003eCleaning\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 367px;\"\u003e\n\u003cp\u003eClean with damp cloth\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\n\u003cp\u003eBattery Life\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 367px;\"\u003e\n\u003cp\u003eTypical battery life of greater than one year\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151px;\"\u003e\n\u003cp\u003eWarranty Period\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 367px;\"\u003e\n\u003cp\u003eTwo years\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434182914133,"sku":"Fluke FLK2AC\/200-1000VCL","price":16988.4,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/35_3243fcf0-c24c-4317-a9a4-1e27dfe1895e.jpg?v=1599486996"},{"product_id":"fluke-prv240fs-proving-unit-t6-ncv","title":"Fluke  PRV240FS Proving unit, T6\/NCV","description":"\u003ch2\u003eProduct overview: Fluke PRV240FS Proving Unit\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cstrong\u003eDesigned for safety and compliance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVerify your test tool without unnecessary exposure to shock and arc flash. Using the PRV240FS reduces the need for personal protective equipment (PPE) when a known voltage source is not available for verification of your tester or multimeter before tests are performed*.  Additionally, the PRV240FS also provides ac and dc voltages for other HiZ instruments in your tool box.\u003c\/p\u003e\n\u003cp\u003eA single switch and a set of LEDs indicate functionality of both the FieldSense “no-test-lead” voltage measurement capability, plus standard ac and dc measurements with test leads. This unit is a simple-to-use solution for complying with TBT verification of your test tools.\u003c\/p\u003e\n\u003cp\u003e*PPE is still needed for absence of voltage testing when appropriate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e“Test Before Touch”\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFluke’s PRV240FS allows you to “Test Before Touch” (TBT), which involves testing your T6 against a known live source before and after the actual measurement. This sequence verifies that your test tool is operating properly during the actual measurement.\u003c\/p\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434183045205,"sku":"Fluke PRV240FS","price":81457.2,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/22_02a30b56-4243-4192-87f5-04f1fc8d409c.jpg?v=1591881901"},{"product_id":"fluke-pls-hv2g-sysmanual-slope-green-rotary-laser-system","title":"Fluke  PLS HV2G SYSmanual slope green rotary laser system","description":"\u003cp\u003ePLS HV2G SYS PLS HV2G SYS,GREEN ROTARY LASER SYSTEM WITH DETECTOR\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe PLS HV2G Bare Tool is a green horizontal with vertical plumb point rotary laser level for level, slope, and square alignment packaged for individual sale in the PLS C19 rotary laser case and printed cardboard box. Features include Green Horizontal\/Vertical Rotary Laser Level, Class II Green Laser, Self-leveling within ñ5 degrees, Dual Manual Slope, Up-Point for Layout Tasks, Alkaline Battery Tray.\u003c\/span\u003e\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434183995477,"sku":"Fluke PLS HV2G SYS","price":652432.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/11_636fe895-5b8f-4127-9f9e-e773074a50f2.jpg?v=1591880064"},{"product_id":"fluke-1507-insulation-tester","title":"Fluke 1507 Insulation Tester","description":"\u003ch2\u003eProduct overview: Fluke 1507 Insulation Resistance Tester\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003eThe Fluke 1507 is a versatile, compact, handheld insulation tester for advanced industrial and electrical insulation testing. Its multiple test voltages make it the ideal tool for many troubleshooting, commissioning, and preventative maintenance applications.\u003c\/p\u003e\n\u003cp\u003eTake advantage of the 1507 full feature set to easily and quickly perform advanced insulation resistance testing. Its handy size and light weight make it easy to pack and use. Additional features, like the remote probe, save both time and money especially when performing repetitive tests. And its reasonable price and rugged reliability make it an excellent value.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful capabilities:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePerforms insulation tests from 0.01 MΩ to 2.0 GΩ\u003c\/li\u003e\n\u003cli\u003eIncludes live circuit detection to prevent insulation test if voltage \u0026gt;30 V is detected\u003c\/li\u003e\n\u003cli\u003eIncludes auto-discharge of capacitive voltage for added user protection\u003c\/li\u003e\n\u003cli\u003eMeasures AC\/DC voltage from 0.1 V to 600 V and resistance from 0.01 Ω to 20.00 kΩ\u003c\/li\u003e\n\u003cli\u003eProvides lo-ohms earth-bond continuity (200 mA)\u003c\/li\u003e\n\u003cli\u003eSimplifies repetitive or hard-to-reach testing with the remote test probe\u003c\/li\u003e\n\u003cli\u003eSaves battery power with auto power off\u003c\/li\u003e\n\u003cli\u003ePresents results on a large, backlit display\u003c\/li\u003e\n\u003cli\u003eFeatures CAT IV 600 V overvoltage category rating\u003c\/li\u003e\n\u003cli\u003eComes with remote probe, test leads, test probes, alligator clips and one-year warranty\u003c\/li\u003e\n\u003cli\u003eAccepts optional Fluke TPAK magnetic hanging system to free your hands for other work\u003c\/li\u003e\n\u003cli\u003eRuns on four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cul\u003e\n\u003cli\u003eRugged, compact advanced insulation resistance tester for electrical contractors and industrial and commercial electricians\u003c\/li\u003e\n\u003cli\u003eAutomatically calculates Polarization Index and Dielectric Absorption Ratio\u003c\/li\u003e\n\u003cli\u003eMakes repetitive tests simple and easy with a Compare (Pass\/Fail) function \u003c\/li\u003e\n\u003cli\u003eOffers multiple insulation test voltages: 50 V, 100 V, 250 V, 500 V, and 1000 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 1507 Insulation Resistance Tester\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 501px;\"\u003eAC\/DC Voltage Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 147px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 158px;\"\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 196px;\"\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 158px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 196px;\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 158px;\"\u003e50 Hz to 400 Hz ± (% of Rdg + Digits)\u003c\/td\u003e\n\u003ctd style=\"width: 196px;\"\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eInput impedance\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e3 MΩ (nominal), \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eCommon mode rejection ratio (1 kΩ unbalanced):\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e\u0026gt; 60 dB at DC, 50 or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e600 V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 501px;\"\u003eEarth Bond Resistance Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 147px;\"\u003eRange\/Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 158px;\"\u003e\u003cb\u003e20.00 Ω\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 196px;\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 158px;\"\u003e200.0 Ω\u003c\/td\u003e\n\u003ctd style=\"width: 196px;\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 158px;\"\u003e2000 Ω\u003c\/td\u003e\n\u003ctd style=\"width: 196px;\"\u003e1.0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 158px;\"\u003e20.00 kΩ\u003c\/td\u003e\n\u003ctd style=\"width: 196px;\"\u003e0.01 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e±(1.5% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e2 V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eOpen circuit test voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e\u0026gt; 4.0 V, \u0026lt; 8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e\u0026gt; 200.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 501px;\"\u003eInsulation Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eMeasurement range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e0.01 MΩ to 10 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eTest voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e50 V, 100 V, 250 V, 500 V, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eTest voltage accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e+ 20%, - 0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e1 mA nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eAuto discharge\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003eDischarge time \u0026lt; 0.5 second for C = 1 µF or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eLive circuit indicator\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003eInhibit test if terminal voltage \u0026gt; 30 V prior to initialization of test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eMaximum capacitive load\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003eOperable with up to 1 µF load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\" style=\"width: 147px;\"\u003eMeasure accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 158px;\"\u003e\u003cb\u003e50 V\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 196px;\"\u003e±(3% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 158px;\"\u003e100 V\u003c\/td\u003e\n\u003ctd style=\"width: 196px;\"\u003e±(3% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 158px;\"\u003e250 V\u003c\/td\u003e\n\u003ctd style=\"width: 196px;\"\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 158px;\"\u003e500 V\u003c\/td\u003e\n\u003ctd style=\"width: 196px;\"\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 158px;\"\u003e1000 V\u003c\/td\u003e\n\u003ctd style=\"width: 196px;\"\u003e±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 501px;\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eMaximum voltage applied to any terminal:\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e600 V AC rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e-40°C to 60°C (-40°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e-20°C to 55°C (-4°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e0.05 x (specified accuracy) per °C for temperatures \u0026lt; 18°C or \u0026gt; 28°C (\u0026lt; 64°F or \u0026gt; 82°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 147px;\"\u003eRelative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 354px;\"\u003e0% to 95% @ 10°C to 30°C (50°F to 86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 354px;\"\u003e0% to 75% @ 30°C to 40°C (86°F to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 354px;\"\u003e0% to 40% @ 40°C to 55°C (104°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eVibration\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003eRandom, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eShock\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003eIn an RF field of 3 V\/M, accuracy = specified accuracy (EN 61326-1:1997)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003eComplies with ANSI\/ISA 82.02.01 (61010-1) 2004, CAN\/CSA-C22.2 NO. 61010-1-04, and IEC\/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003eCSA per standard CSA\/CAN C22.2 No. 61010.1-04; TUV per standard IEC\/EN 61010-1 2nd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003eFour AA batteries (NEDA 15A or IEC LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 147px;\"\u003eBattery life\u003c\/td\u003e\n\u003ctd style=\"width: 158px;\"\u003e\u003cb\u003eInsulation test use:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 196px;\"\u003eTester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 158px;\"\u003eResistance measurements:\u003c\/td\u003e\n\u003ctd style=\"width: 196px;\"\u003eTester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e550 g (1.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 147px;\"\u003eAltitude\u003c\/td\u003e\n\u003ctd style=\"width: 158px;\"\u003e\u003cb\u003eOperating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 196px;\"\u003e2000 m CAT IV 600 V, 3000 m CAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 158px;\"\u003eNon-operating (storage)\u003c\/td\u003e\n\u003ctd style=\"width: 196px;\"\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eOver-range capability\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003e110% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147px;\"\u003eIncluded accessories\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 354px;\"\u003eTL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434185994325,"sku":"Fluke 1507","price":404019.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/222_2dc43ee2-d0cb-4ec6-865c-553be9252b96.jpg?v=1591888395"},{"product_id":"fluke-1587t-insulation-multimeter-telecom","title":"Fluke 1587T Insulation multimeter (Telecom)","description":"\u003ch3\u003eFLUKE-1587 T FLUKE-1587 T,INSULATION MULTIMETER\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"a-unordered-list a-vertical a-spacing-mini\"\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eManual- and auto-ranging digital insulation multimeter measures insulation resistance, current, voltage, capacitance, frequency, resistance, and temperature, and performs diode tests for telecommunications testing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eTrue RMS meter provides accurate readings when measuring linear or nonlinear loads where the current or voltage has an undistorted or distorted waveform\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eInsulation test voltages of 50 and 100 volts and insulation measurement range of 0.01 to 100 megaohms\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eLow-pass filter blocks unwanted voltages when measuring AC voltage and AC frequency to provide accurate measurements on inverters and variable-frequency motor drives\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan class=\"a-list-item\"\u003eIngress Protection Certified IP40; European Conformity (CE) marking; UL 61010-1; ANSI\/ISA S82.01-2004; CAN\/CSA C22.2 No. 1010.1:2004; IEC safety standards 61010-1:1002 and 61010.1-04, IEC61557-1; IEC61557-2; and IEC\/EN 61010-1, 2nd edition for Category III installations up to 1000V and Category IV installations up to 600V, and Pollution Degree 2\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct overview: Fluke 1587 FC Insulation Multimeter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cb\u003eKeep yourself safe. Find hidden problems faster. Put the paperwork down.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eFluke Connect + Fluke's 1587 FC Insulation Multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily - all at a safe distance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdd diagnostics with Fluke Connect\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1587 FC is Fluke Connect-enabled so you can download the free Fluke Connect® Measurements app to your smartphone and gain additional functions, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSafety first. Keep yourself out of harm’s way by monitoring your test measurements remotely.\u003c\/li\u003e\n\u003cli\u003eProve your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone.\u003c\/li\u003e\n\u003cli\u003eQuickly find problems by saving and comparing measurements over time on a wireless device.\u003c\/li\u003e\n\u003cli\u003ePI\/DAR timed ratio tests with TrendIt™ graphs to identify moisture and contaminated insulation problems faster\u003c\/li\u003e\n\u003cli\u003eMemory storage through Fluke Connect that saves measurements to your phone or the cloud and eliminates the need to write down results. Reduces errors and saves data for historical tracking over time\u003c\/li\u003e\n\u003cli\u003eTemperature compensation to establish accurate baselines and relevant historical comparisons\u003c\/li\u003e\n\u003cli\u003eHistorical tracking and trending of assets to identify insulation degradation over time and allow real-time decisions to be made in the field with Fluke Connect® Assets (sold separately)\u003c\/li\u003e\n\u003cli\u003eProvides memory storage through Fluke Connect Measurements to eliminate the need to write down results\u003c\/li\u003e\n\u003cli\u003eIncludes live circuit detection to prevent insulation test if voltage \u0026gt;30 V is detected\u003c\/li\u003e\n\u003cli\u003eProvides automated temperature compensation to establish accurate baselines\u003c\/li\u003e\n\u003cli\u003eSupports historical tracking and asset trending of assets to identify degradation over time with Fluke Connect® Assets (sold separately)\u003c\/li\u003e\n\u003cli\u003eIncorporates VFD low-pass filter for accurate variable frequency motor drive measurements\u003c\/li\u003e\n\u003cli\u003eIncludes auto-discharge of capacitive voltage for added user protection\u003c\/li\u003e\n\u003cli\u003eMeasures ac\/dc voltage, dc millivolts, ac\/dc milliamps, resistance, and continuity\u003c\/li\u003e\n\u003cli\u003eIncludes capacitance, diode test, temperature, min\/max, frequency measurements and insulation test smoothing reading\u003c\/li\u003e\n\u003cli\u003eAutomatically powers off to save battery power\u003c\/li\u003e\n\u003cli\u003eComes with remote probe, test leads, alligator clips, K-type thermocouple, hard case, and three-year warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 1587 FC Insulation Multimeter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eElectrical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAC voltage measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eRange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e600.0 mV\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e6.000 V\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e60.00 V\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e600.0 V\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3)¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3)¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small\" colspan=\"3\"\u003e¹ 1 kHz bandwidth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eLow-Pass Filter Voltage \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eRange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e600.0 mV\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e+(2% + 3), -(6% - 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e6.000 V\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e+(2% + 3), -(6% - 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e60.00 V\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e+(2% + 3), -(6% - 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e600.0 V\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e+(2% + 3), -(6% - 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e+(2% + 3), -(6% - 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDC Voltage Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy ±(% of Rdg + Counts)\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6.000 V dc\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003c\/td\u003e\n\u003ctd\u003e±(0.09% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60.00 V dc\u003c\/td\u003e\n\u003ctd\u003e0.01 V\u003c\/td\u003e\n\u003ctd\u003e±(0.09% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e600.0 V dc\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e±(0.09% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V dc\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003ctd\u003e±(0.09% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 MΩ (nominal), \u0026lt;100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal mode rejection ratio \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;60 dB @ 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003eAccuracies apply to ± 100% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDC Millivolts Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy ±(% of Rdg + Counts)\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e600.0 mVdc\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003ctd\u003e±(0.1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDC and AC Current Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAC 45 Hz to 1000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy ±(% of Rdg+Counts)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(1.5% + 2)¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurden voltage (Typical)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 mV\/mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e60 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy ±(% of Rdg+Counts)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(1.5% + 2)¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurden voltage (Typical)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 mV\/mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy ±(% of Rdg+Counts)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(0.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurden voltage (Typical)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 mV\/mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e60 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy ±(% of Rdg+Counts)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(0.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurden voltage (Typical)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 mV\/mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 mA for 2 minutes maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse protection for mA input\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.44 mA, 1000 V, IR 10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC conversion\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eInputs are ac-coupled and calibrated to the rms value of sine wave input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eConversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003e¹ 1 kHz bandwidth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eOhms Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy +(% of Rdg+Counts)¹\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e600.0 Ω\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003ctd\u003e±(0.9% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6.000 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.001 kΩ\u003c\/td\u003e\n\u003ctd\u003e±(0.9% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60.00 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 kΩ\u003c\/td\u003e\n\u003ctd\u003e±(0.9% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e600.0 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.1 KΩ\u003c\/td\u003e\n\u003ctd\u003e±(0.9% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6.000 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.001 MΩ\u003c\/td\u003e\n\u003ctd\u003e±(0.9% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50.0 MΩ ²\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V rms or dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit test voltage \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt;8.0 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt;1.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003e¹ Accuracies apply from 0% to 100% of range\u003cbr\u003e² Up to 80% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDiode Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode test indication\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDisplay voltage drop: 0.6 V at1.0 mA nominal test current:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eContinuity Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity indication\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eContinuous audible tone for testresistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt;8.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.0 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;1 m sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eFrequency Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eAccuracy ±(% of Rdg+Counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e99.99 Hz \u003c\/td\u003e\n\u003ctd\u003e0.01 Hz \u003c\/td\u003e\n\u003ctd\u003e±(0.1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e999.9 Hz \u003c\/td\u003e\n\u003ctd\u003e0.1 Hz \u003c\/td\u003e\n\u003ctd\u003e±(0.1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9.999 kHz \u003c\/td\u003e\n\u003ctd\u003e0.001 kHz \u003c\/td\u003e\n\u003ctd\u003e±(0.1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e99.99 kHz \u003c\/td\u003e\n\u003ctd\u003e0.01 kHz \u003c\/td\u003e\n\u003ctd\u003e±(0.1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eFrequency Counter Sensitivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e600.0 mV ac \u003c\/td\u003e\n\u003ctd\u003eV ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz \u003c\/td\u003e\n\u003ctd\u003e100.0 mV \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eV ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz\u003c\/td\u003e\n\u003ctd\u003e150.0 mV \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDC Trigger Levels¹ to 20 kHz²\u003c\/td\u003e\n\u003ctd\u003eNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e6.0 V \u003c\/td\u003e\n\u003ctd\u003eV ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz \u003c\/td\u003e\n\u003ctd\u003e1.0 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eV ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz\u003c\/td\u003e\n\u003ctd\u003e1.5 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDC Trigger Levels¹ to 20 kHz²\u003c\/td\u003e\n\u003ctd\u003e-400.0 mV and 2.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e60.0 V \u003c\/td\u003e\n\u003ctd\u003eV ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz \u003c\/td\u003e\n\u003ctd\u003e10.0 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eV ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz\u003c\/td\u003e\n\u003ctd\u003e36.0 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDC Trigger Levels¹ to 20 kHz²\u003c\/td\u003e\n\u003ctd\u003e1.2 V and 4.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e600.0 V \u003c\/td\u003e\n\u003ctd\u003eV ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz \u003c\/td\u003e\n\u003ctd\u003e100.0 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eV ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDC Trigger Levels¹ to 20 kHz²\u003c\/td\u003e\n\u003ctd\u003e12.0 V and 40.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e1000.0 V \u003c\/td\u003e\n\u003ctd\u003eV ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz \u003c\/td\u003e\n\u003ctd\u003e300.0 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eV ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDC Trigger Levels¹ to 20 kHz²\u003c\/td\u003e\n\u003ctd\u003e12.0 V and 40.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003e¹ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy\u003cbr\u003e² Usable to 100 kHz with full scale input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eCapacitance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange \u003c\/td\u003e\n\u003ctd\u003eResolution \u003c\/td\u003e\n\u003ctd\u003eAccuracy ±(% of Rdg+Counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 nF \u003c\/td\u003e\n\u003ctd\u003e1 nF\u003c\/td\u003e\n\u003ctd\u003e±(1.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10.00 μF \u003c\/td\u003e\n\u003ctd\u003e0.01 μF\u003c\/td\u003e\n\u003ctd\u003e±(1.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100.0 μF \u003c\/td\u003e\n\u003ctd\u003e0.1 μF\u003c\/td\u003e\n\u003ctd\u003e±(1.2% ±90 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e9999 μF \u003c\/td\u003e\n\u003ctd\u003e1 μF\u003c\/td\u003e\n\u003ctd\u003e±(1.2% ±90 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eTemperature Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange \u003c\/td\u003e\n\u003ctd\u003eResolution \u003c\/td\u003e\n\u003ctd\u003eAccuracy ±(% of Rdg+Counts)¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-40 ° C to 537 ° C \u003c\/td\u003e\n\u003ctd\u003e0.1 °C \u003c\/td\u003e\n\u003ctd\u003e±(1% + 10 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-40 ° F to 998 ° F \u003c\/td\u003e\n\u003ctd\u003e0.1 °F \u003c\/td\u003e\n\u003ctd\u003e±(1% + 18 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\"\u003e¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eInsulation Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 MΩ to 2 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltages\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50, 100, 250, 500, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+20%, -0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit test current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mA nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto discharge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDischarge time \u0026lt;0.5 second for C = 1 μF or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLive circuit detection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eInhibit test if terminal voltage \u0026gt; 30 V prior to initialization of test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum capacitive load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOperable with up to 1 μF load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eOutput Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"8\"\u003e50 V (0% to +20%)\u003c\/td\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e0.01 to 6.00 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 50 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e6.0 to 50.0 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 50 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"12\"\u003e100 V (0% to +20%)\u003c\/td\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e0.01 to 6.00 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e6.0 to 60.0 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e60 to 100 MΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"8\"\u003e250 V (0% to +20%)\u003c\/td\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e0.1 to 60.0 MΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 250 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e60 to 250 MΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 250 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"8\"\u003e500 V (0% to +20%)\u003c\/td\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e0.1 to 60.0 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 500 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e60 to 500 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 500 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"12\"\u003e1000 V (0% to +20%)\u003c\/td\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e0.1 to 60.0 MΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e60 to 600 MΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e0.6 to 2.0 GΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e100 MΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eTest current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd\u003e±(10% + 3 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage applied to any terminal and common\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40 °C to 60 °C (-40 °F to 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20 °C to 55 °C (-4 °F to 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.05 x (specified accuracy) per °C for temperatures \u0026lt;18 °C or \u0026gt;28 °C (\u0026lt;64 °F or \u0026gt;82 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRelative humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNoncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRandom, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio frequency communication\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2.4 GHz ISM Band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio frequency certification\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFCC: T68-FBLE, IC: 6627A-FBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eElectromagnetic Compatibility \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eInternational\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eGroup 1: Equipment has intentionally generated and\/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eClass A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes.  There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eEmissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and\/or test probes are connected.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eKorea (KCC)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eClass A Equipment (Industrial Broadcasting \u0026amp; Communication Equipment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eClass A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSA (FCC)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 60529: IP40 (non-operating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSafety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIEC 61010-1\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIEC 61010-2-033\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFour AA batteries (IEC LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMeter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e550 g (1.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eOperating\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-range capability\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e110% of range except for capacitance which is 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency overload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt;107 V Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse protection for mA input\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.44A, 1000 V, IR 10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434186354773,"sku":"Fluke 1587T","price":426888.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/5_413e48be-b632-4356-9dcf-0d8368561edc.jpg?v=1592217182"},{"product_id":"fluke-1587-fc-2-in-1-insulation-multimeter","title":"Fluke 1587 FC 2-IN-1 Insulation Multimeter","description":"\u003ch2\u003eProduct overview: Fluke 1587 FC Insulation Multimeter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cb\u003eKeep yourself safe. Find hidden problems faster. Put the paperwork down.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eFluke Connect + Fluke's 1587 FC Insulation Multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily - all at a safe distance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdd diagnostics with Fluke Connect\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1587 FC is Fluke Connect-enabled so you can download the free Fluke Connect® Measurements app to your smartphone and gain additional functions, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSafety first. Keep yourself out of harm’s way by monitoring your test measurements remotely.\u003c\/li\u003e\n\u003cli\u003eProve your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone.\u003c\/li\u003e\n\u003cli\u003eQuickly find problems by saving and comparing measurements over time on a wireless device.\u003c\/li\u003e\n\u003cli\u003ePI\/DAR timed ratio tests with TrendIt™ graphs to identify moisture and contaminated insulation problems faster\u003c\/li\u003e\n\u003cli\u003eMemory storage through Fluke Connect that saves measurements to your phone or the cloud and eliminates the need to write down results. Reduces errors and saves data for historical tracking over time\u003c\/li\u003e\n\u003cli\u003eTemperature compensation to establish accurate baselines and relevant historical comparisons\u003c\/li\u003e\n\u003cli\u003eHistorical tracking and trending of assets to identify insulation degradation over time and allow real-time decisions to be made in the field with Fluke Connect® Assets (sold separately)\u003c\/li\u003e\n\u003cli\u003eProvides memory storage through Fluke Connect Measurements to eliminate the need to write down results\u003c\/li\u003e\n\u003cli\u003eIncludes live circuit detection to prevent insulation test if voltage \u0026gt;30 V is detected\u003c\/li\u003e\n\u003cli\u003eProvides automated temperature compensation to establish accurate baselines\u003c\/li\u003e\n\u003cli\u003eSupports historical tracking and asset trending of assets to identify degradation over time with Fluke Connect® Assets (sold separately)\u003c\/li\u003e\n\u003cli\u003eIncorporates VFD low-pass filter for accurate variable frequency motor drive measurements\u003c\/li\u003e\n\u003cli\u003eIncludes auto-discharge of capacitive voltage for added user protection\u003c\/li\u003e\n\u003cli\u003eMeasures ac\/dc voltage, dc millivolts, ac\/dc milliamps, resistance, and continuity\u003c\/li\u003e\n\u003cli\u003eIncludes capacitance, diode test, temperature, min\/max, frequency measurements and insulation test smoothing reading\u003c\/li\u003e\n\u003cli\u003eAutomatically powers off to save battery power\u003c\/li\u003e\n\u003cli\u003eComes with remote probe, test leads, alligator clips, K-type thermocouple, hard case, and three-year warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 1587 FC Insulation Multimeter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eElectrical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eAC voltage measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eRange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 160.333px;\"\u003e600.0 mV\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eAccuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 160.333px;\"\u003e6.000 V\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eAccuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 160.333px;\"\u003e60.00 V\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e0.01 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eAccuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 160.333px;\"\u003e600.0 V\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eAccuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(2% + 3)¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 160.333px;\"\u003e1000 V\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eAccuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(2% + 3)¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small\" colspan=\"3\" style=\"width: 504px;\"\u003e¹ 1 kHz bandwidth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eLow-Pass Filter Voltage \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eRange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 160.333px;\"\u003e600.0 mV\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eAccuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e+(2% + 3), -(6% - 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 160.333px;\"\u003e6.000 V\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eAccuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e+(2% + 3), -(6% - 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 160.333px;\"\u003e60.00 V\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e0.01 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eAccuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e+(2% + 3), -(6% - 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 160.333px;\"\u003e600.0 V\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(1% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eAccuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e+(2% + 3), -(6% - 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 160.333px;\"\u003e1000 V\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eAccuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eAccuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e+(2% + 3), -(6% - 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eDC Voltage Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e\u003cb\u003eAccuracy ±(% of Rdg + Counts)\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003e6.000 V dc\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003e0.001 V\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(0.09% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003e60.00 V dc\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003e0.01 V\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(0.09% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003e600.0 V dc\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(0.09% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003e1000 V dc\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003e1 V\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(0.09% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eInput impedance \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e10 MΩ (nominal), \u0026lt;100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eNormal mode rejection ratio \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e\u0026gt;60 dB @ 50 Hz or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eCommon mode rejection ratio \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e\u0026gt;120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\" style=\"width: 504px;\"\u003eAccuracies apply to ± 100% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eDC Millivolts Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e\u003cb\u003eAccuracy ±(% of Rdg + Counts)\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003e600.0 mVdc\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003e0.1 mV\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(0.1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eDC and AC Current Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eAC 45 Hz to 1000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eAccuracy ±(% of Rdg+Counts)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e±(1.5% + 2)¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eBurden voltage (Typical)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e2 mV\/mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e60 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e0.01 mA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eAccuracy ±(% of Rdg+Counts)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e±(1.5% + 2)¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eBurden voltage (Typical)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e2 mV\/mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e400 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e0.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eAccuracy ±(% of Rdg+Counts)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e±(0.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eBurden voltage (Typical)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e2 mV\/mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e60 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eAccuracy ±(% of Rdg+Counts)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e±(0.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eBurden voltage (Typical)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e2 mV\/mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eOverload\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e600 mA for 2 minutes maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eFuse protection for mA input\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e0.44 mA, 1000 V, IR 10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eAC conversion\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003eInputs are ac-coupled and calibrated to the rms value of sine wave input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\" style=\"width: 504px;\"\u003eConversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\" style=\"width: 504px;\"\u003e¹ 1 kHz bandwidth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eOhms Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e\u003cb\u003eAccuracy +(% of Rdg+Counts)¹\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003e600.0 Ω\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003e0.1 Ω\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(0.9% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003e6.000 kΩ\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003e0.001 kΩ\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(0.9% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003e60.00 kΩ\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003e0.01 kΩ\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(0.9% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003e600.0 kΩ\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003e0.1 KΩ\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(0.9% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003e6.000 MΩ\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003e0.001 MΩ\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(0.9% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003e50.0 MΩ ²\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003e0.01 MΩ\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(1.5% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eOverload protection \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e1000 V rms or dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eOpen circuit test voltage \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e\u0026lt;8.0 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eShort circuit current \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e\u0026lt;1.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\" style=\"width: 504px;\"\u003e¹ Accuracies apply from 0% to 100% of range\u003cbr\u003e² Up to 80% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eDiode Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eDiode test indication\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003eDisplay voltage drop: 0.6 V at1.0 mA nominal test current:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eContinuity Test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eContinuity indication\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003eContinuous audible tone for testresistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e\u0026lt;8.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e1.0 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e1000 V rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eResponse time\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e\u0026gt;1 m sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eFrequency Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eRange\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003eAccuracy ±(% of Rdg+Counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003e99.99 Hz \u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003e0.01 Hz \u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(0.1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003e999.9 Hz \u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003e0.1 Hz \u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(0.1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003e9.999 kHz \u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003e0.001 kHz \u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(0.1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003e99.99 kHz \u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003e0.01 kHz \u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(0.1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eFrequency Counter Sensitivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 160.333px;\"\u003e600.0 mV ac \u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003eV ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz \u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e100.0 mV \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eV ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e150.0 mV \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eDC Trigger Levels¹ to 20 kHz²\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003eNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 160.333px;\"\u003e6.0 V \u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003eV ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz \u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e1.0 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eV ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e1.5 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eDC Trigger Levels¹ to 20 kHz²\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e-400.0 mV and 2.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 160.333px;\"\u003e60.0 V \u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003eV ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz \u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e10.0 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eV ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e36.0 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eDC Trigger Levels¹ to 20 kHz²\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e1.2 V and 4.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 160.333px;\"\u003e600.0 V \u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003eV ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz \u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e100.0 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eV ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eDC Trigger Levels¹ to 20 kHz²\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e12.0 V and 40.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 160.333px;\"\u003e1000.0 V \u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003eV ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz \u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e300.0 V \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eV ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eDC Trigger Levels¹ to 20 kHz²\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e12.0 V and 40.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\" style=\"width: 504px;\"\u003e¹ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy\u003cbr\u003e² Usable to 100 kHz with full scale input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eCapacitance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eRange \u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003eResolution \u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003eAccuracy ±(% of Rdg+Counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003e1000 nF \u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003e1 nF\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(1.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003e10.00 μF \u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003e0.01 μF\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(1.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003e100.0 μF \u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003e0.1 μF\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(1.2% ±90 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 160.333px;\"\u003e9999 μF \u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003e1 μF\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(1.2% ±90 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eTemperature Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eRange \u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003eResolution \u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003eAccuracy ±(% of Rdg+Counts)¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003e-40 ° C to 537 ° C \u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003e0.1 °C \u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(1% + 10 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003e-40 ° F to 998 ° F \u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003e0.1 °F \u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(1% + 18 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"3\" style=\"width: 504px;\"\u003e¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eInsulation Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eMeasurement range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e0.01 MΩ to 2 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eTest voltages\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e50, 100, 250, 500, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eTest voltage accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e+20%, -0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eShort-circuit test current\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e1 mA nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eAuto discharge\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003eDischarge time \u0026lt;0.5 second for C = 1 μF or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eLive circuit detection\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003eInhibit test if terminal voltage \u0026gt; 30 V prior to initialization of test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eMaximum capacitive load\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003eOperable with up to 1 μF load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"8\" style=\"width: 160.333px;\"\u003e50 V (0% to +20%)\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e0.01 to 6.00 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eTest current\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e1 mA @ 50 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(3% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e6.0 to 50.0 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eTest current\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e1 mA @ 50 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(3% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"12\" style=\"width: 160.333px;\"\u003e100 V (0% to +20%)\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e0.01 to 6.00 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eTest current\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e1 mA @ 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(3% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e6.0 to 60.0 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eTest current\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e1 mA @ 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(3% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e60 to 100 MΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eTest current\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e1 mA @ 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(3% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"8\" style=\"width: 160.333px;\"\u003e250 V (0% to +20%)\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e0.1 to 60.0 MΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eTest current\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e1 mA @ 250 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(1.5% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e60 to 250 MΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eTest current\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e1 mA @ 250 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(1.5% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"8\" style=\"width: 160.333px;\"\u003e500 V (0% to +20%)\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e0.1 to 60.0 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eTest current\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e1 mA @ 500 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(1.5% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e60 to 500 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eTest current\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e1 mA @ 500 kΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(1.5% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"12\" style=\"width: 160.333px;\"\u003e1000 V (0% to +20%)\u003c\/td\u003e\n\u003ctd style=\"width: 183.667px;\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e0.1 to 60.0 MΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e0.1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eTest current\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e1 mA @ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(1.5% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e60 to 600 MΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eTest current\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e1 mA @ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(1.5% + 5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e0.6 to 2.0 GΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e100 MΩ \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eTest current\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e1 mA @ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 183.667px;\"\u003eResistance accuracy ±(% of Rdg + Counts)\u003c\/td\u003e\n\u003ctd style=\"width: 160px;\"\u003e±(10% + 3 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eMaximum voltage applied to any terminal and common\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e-40 °C to 60 °C (-40 °F to 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e-20 °C to 55 °C (-4 °F to 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e0.05 x (specified accuracy) per °C for temperatures \u0026lt;18 °C or \u0026gt;28 °C (\u0026lt;64 °F or \u0026gt;82 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 160.333px;\"\u003eRelative humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003eNoncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 343.667px;\"\u003e0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 343.667px;\"\u003e0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 343.667px;\"\u003e0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eVibration\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003eRandom, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eRadio frequency communication\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e2.4 GHz ISM Band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eRadio frequency certification\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003eFCC: T68-FBLE, IC: 6627A-FBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eElectromagnetic Compatibility \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 160.333px;\"\u003eInternational\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003eIEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 343.667px;\"\u003eGroup 1: Equipment has intentionally generated and\/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 343.667px;\"\u003eClass A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes.  There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 343.667px;\"\u003eEmissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and\/or test probes are connected.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 160.333px;\"\u003eKorea (KCC)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003eClass A Equipment (Industrial Broadcasting \u0026amp; Communication Equipment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\" style=\"width: 343.667px;\"\u003eClass A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eUSA (FCC)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eEnclosure protection\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003eIEC 60529: IP40 (non-operating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eSafety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eIEC 61010-1\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003ePollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eIEC 61010-2-033\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003eCAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eBatteries \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003eFour AA batteries (IEC LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 160.333px;\"\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 343.667px;\"\u003eMeter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434186387541,"sku":"Fluke 1587 FC","price":398558.97,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/4_e0cd79d2-5cf0-4c0a-8c60-adfcada64422.jpg?v=1592217020"},{"product_id":"fluke-1662-uk-installation-tester-w-mem-uk","title":"Fluke 1662 UK Installation Tester w\/mem UK","description":"\u003ch2\u003eProduct overview: Fluke 1662 Multifunction Testers\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 1662 Multifunction Installation Tester delivers solid, basic installation testing features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1662 installation tester gives you Fluke reliability and all the basic testing power you need for day-in, day-out installation testing. It tests to all local regulations and is easy and intuitive to use. Additional helpful features like the On\/Off switchable auto-start for RCD and loop test, and self-test save time and give you more confidence in your results.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures RCD switching time and tripping level (ramp test)\u003c\/li\u003e\n\u003cli\u003eMeasures trip time and current for RCD type A \u0026amp; AC in one test\u003c\/li\u003e\n\u003cli\u003eMeasures RCD variable current\u003c\/li\u003e\n\u003cli\u003eProvides automatic RCD test sequence\u003c\/li\u003e\n\u003cli\u003eIncludes Z-max memory for loop tests to support easy evaluation of the highest loop test value\u003c\/li\u003e\n\u003cli\u003eProvides unique zero adapter for fast, reliable and accurate test lead and mains cord compensation\u003c\/li\u003e\n\u003cli\u003eIncludes a phase sequence indicator\u003c\/li\u003e\n\u003cli\u003eComes with hard carrying case, padded carrying and waist strap, and remote control probe and lead\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eKey features\u003cbr\u003eA solid, reliable, basic installation tester\u003cbr\u003eTests voltage and frequency\u003cbr\u003eChecks wiring polarity to detect broken N wires\u003cbr\u003eMeasures insulation resistance and loop and line resistance\u003cbr\u003eMeasures motor windings with continuity test\u003cbr\u003eCalculates prospective earth fault current (PEFC\/IK) and prospective short-circuit current (PSC\/IK)\u003c\/p\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434186518613,"sku":"Fluke 1662 UK","price":634233.6,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/1c.jpg?v=1592224498"},{"product_id":"fluke-1664fc-uk-fc-installation-tester-w-insulation-pre-test-uk","title":"Fluke 1664FC UK Installation Tester w\/Insulation Pre-Test UK","description":"\u003ch2 data-mce-fragment=\"1\"\u003eProduct overview: Fluke 1664 FC Installation Multifunction Testers\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\" data-mce-fragment=\"1\"\u003e\n\u003cdiv id=\"product-overview\" data-mce-fragment=\"1\"\u003e\n\u003cdiv id=\"overview_content\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFluke 1664 FC Multifunction Installation Tester helps expedite installations\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe 1664 FC puts a lot of testing power in your hands to quickly and efficiently test to all local regulations, protect appliances, and share test results in real time over your smartphone.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eProtect appliances from accidental damage\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Fluke 1664 FC is the only tester with \"Insulation PreTest\" that stops the insulation test and provides a visual warning if it detects that an appliance is connected to the system under test. This helps you avoid potentially serious and costly mistakes that can cause damage to your customers’ peripheral equipment.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAuto Test reduces test time\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAuto Test performs up to seven installation tests in one sequence, ensuring compliance with local installation regulations. This reduces the number of manual connections, thus decreasing the possibility of errors and reducing test time.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSave time and enhance collaboration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eBecause the 1664 FC is Fluke Connect®-enabled, you can send test results to your smartphone, save them to the cloud, and share measurements in real time with team members through a ShareLive video call. It's the fastest way to let your team see what you see, and to help you get approvals without leaving the field.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eRetrieve stored results from anywhere\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eFluke Cloud™ storage allows you to retrieve stored results whether you are in the office or in the field to make decisions in real time. You get world-class data protection and you can import the data into Fluke DMS (Data Management Software) to process and generate certificates.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eOther helpful features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCompact, lightweight (less than 1.3 kg) with padded neck-strap to free your hands\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRotary dial knob clearly indicates which function is selected, all in one spot with no complex multi-level menus.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eOffers additional high current loop mode for faster measurements than loop tests with non-trip mode for RCDs\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIncludes Z-max memory for loop tests to support easy evaluation of the highest loop test value\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eProvides unique zero adapter for fast, reliable and accurate test lead and mains cord compensation\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePerforms fast voltage measurement between L-N, L-PE, and N-PE using the mains cord. No need to change measurement connections\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeasures RCD trip current and trip time in parallel (RCD type AC and A)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeasures PEFC or PSC and loop impedance in parallel and displays them together on the dual display\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eOffers ring testing so you can select the required input sockets with soft keys and not have to exchange test leads\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUses continuity test currents to measure motor windings\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDetects raised earth voltages \u0026gt; 50 V with Earth Volt Touchpad, indicating potential dangerous situations\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFeatures large display with backlight, clear symbols, and exceptionally wide viewing angle for easy and safe readings\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eOffers extended three-layer memory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv aria-expanded=\"true\" data-readmore=\"\" id=\"keyfeature_content\"\u003eMultifunction tester that tests to all local regulations\n\u003cul\u003e\n\u003cli\u003eIncludes \"Insulation Pre-test\" that detects when appliances are connected to the system and stops the test\u003c\/li\u003e\n\u003cli\u003eRuns seven installation tests automatically in one sequence with a single connection through Auto Test\u003c\/li\u003e\n\u003cli\u003eAllows you to share test results in real time over your smartphone via Fluke Connect Measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 1664 FC Installation Multifunction Testers\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003e\u003cspan\u003eAC voltage measurement\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e500 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e0.1 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eAccuracy 45 Hz – 66 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e0.8% + 3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eInput impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e360 kΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eOverload protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e660 V rms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003e\u003cspan\u003eContinuity testing (RLO)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eRange (autoranging)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e20 Ω \/ 200 Ω \/ 2000 Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e0.01 Ω \/ 0.1 Ω \/ 1 Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eOpen Circuit Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e\u0026gt;4 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003e\u003cspan\u003eInsulation resistance measurement (RISO)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eTest voltages\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e50-100-250-500-1000 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eAccuracy of tTest voltage (at rated test current)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e+10%, -0%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eTest voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e50 V\u003cbr\u003e100 V\u003cbr\u003e250 V\u003cbr\u003e500 V\u003cbr\u003e1000 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eInsulation resistance range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e20 MΩ \/50 MΩ\u003cbr\u003e20 MΩ \/ 100 MΩ\u003cbr\u003e20 MΩ \/ 200 MΩ\u003cbr\u003e20 MΩ \/ 200 MΩ \/ 500 MΩ\u003cbr\u003e20 MΩ \/ 200 MΩ \/ 1000 MΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e0.01 MΩ \/ 0.1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ \/ 1 MΩ\u003cbr\u003e0.01 MΩ \/ 0.1 MΩ \/ 1 MΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eTest current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e1 mA @ 50 kΩ\u003cbr\u003e1 mA @ 100 kΩ\u003cbr\u003e1 mA @ 250 kΩ\u003cbr\u003e1 mA @ 500 kΩ\u003cbr\u003e1 mA @ 1 MΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003e\u003cspan\u003eLoop and line impedance (ZI)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e10 Ω \/ 0.001 Ω \/ High current mΩ mode\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e0.01 Ω \/ 0.1 Ω \/ 1 Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003e\u003cspan\u003eProspective earth fault current, PSC test\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e1000 A \/ 10 kA (50 kA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e1 A \/ 0.1 kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eComputation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003eProspective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003e\u003cspan\u003eRCD testing, RCD types tested\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eRCD Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003eAC¹\u003cbr\u003eG²,S³\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eModel 1664\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003eA, AC, B\u003csup\u003e5\u003c\/sup\u003e, S\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eNotes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e¹Responds to AC\u003cbr\u003e²General, no delay\u003cbr\u003e³Time delay\u003cbr\u003e\u003csup\u003e4\u003c\/sup\u003eResponds to pulsed signal\u003cbr\u003e\u003csup\u003e5\u003c\/sup\u003eResponds to smooth DC signal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003e\u003cspan\u003eTripping speed test (ΔT)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eCurrent settings¹\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e10-30-100-300-500-1000 mA – VAR\u003cbr\u003e10-30-100 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eMultiplier\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003ex ½, x 1\u003cbr\u003ex 5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 181px;\"\u003e\u003cspan\u003eMeasurement range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003e\u003cspan\u003eRCD Type G\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 210px;\"\u003e\u003cspan\u003e310 ms\u003cbr\u003e50 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 113px;\"\u003e\u003cspan\u003eRCD Type S\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 210px;\"\u003e\u003cspan\u003e510 ms\u003cbr\u003e160 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eNotes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e¹1000 mA type AC only\u003cbr\u003e700 mA maximum type A in VAR mode\u003cbr\u003eVAR mode not available for type B.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003e\u003cspan\u003eRCD\/FI-Tripping Current Measurement\/Ramp Test (IΔN)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eCurrent range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e30% to 110% of RCD rated current¹\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eStep size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e10% of IΔN²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 181px;\"\u003e\u003cspan\u003eDwell time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 113px;\"\u003e\u003cspan\u003eType G\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 210px;\"\u003e\u003cspan\u003e300 ms\/step\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 113px;\"\u003e\u003cspan\u003eType S\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 210px;\"\u003e\u003cspan\u003e500 ms\/step\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eMeasurement accuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e±5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eSpecified trip current ranges (EN 61008-1)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e50% to 100% for Type AC\u003cbr\u003e35% to 140% for Type A (\u0026gt;10 mA)\u003cbr\u003e35% to 200% for Type A (≤10 mA)\u003cbr\u003e50% to 200% for Type B\u003cbr\u003e²5% for Type B\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eNotes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e¹30% to 150% for Type A IΔN \u0026gt; 10 mA\u003cbr\u003e30% to 210% for Type A IΔN = 10 mA\u003cbr\u003e20% to 210% for Type B\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003e\u003cspan\u003eEarth Resistance Test (RE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e200 Ω \/ 2000 Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e0.1 Ω \/ 1Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eFrequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e128 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eOutput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e25 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003e\u003cspan\u003ePhase Sequence Indication\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eIcon\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/icon_phase_sequence_indicator.png\" alt=\"icon phase sequence indicator\" align=\"top\"\u003e Phase Sequence indicator is active.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003e\u003cspan\u003eGeneral Specifications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eSize (L x W x H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e10 x 25 x 12.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eWeight (incl. batteries)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003e1.3 Kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eBattery size, quantity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003eType AA, 6 ea.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eSealing\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003eIP-40\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eSafety\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003eComplies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI\/ISA –s82.02.01 2000 and CAN\/CSA c22.2 No. 1010 2nd edition\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003eOvervoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003eCAT III \/ 500V; CAT IV 300V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 181px;\"\u003e\u003cspan\u003ePerformance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 323px;\"\u003e\u003cspan\u003eEN61557-1 to EN61557-7 Second Edition and EN61557-10 Second Edition\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434186649685,"sku":"Fluke 1664FC UK","price":939153.6,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/Fluke-1664FC-30060461-01.jpg?v=1600256990"},{"product_id":"fluke-6200-2-uk-portable-appliance-tester-uk","title":"Fluke 6200-2 UK Portable Appliance Tester UK","description":"\u003ch2\u003eProduct overview: Fluke 6200-2 UK Portable Appliance Tester Starter\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cstrong\u003eFluke 6200-2 UK Starter contains:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e6200-2 Portable appliance tester\u003c\/li\u003e\n\u003cli\u003eIRP1, Register For Pat ( Log Book )\u003c\/li\u003e\n\u003cli\u003eEXTL 100, Extension Lead Test Adaptor\u003c\/li\u003e\n\u003cli\u003eFAIL250, Label\u003c\/li\u003e\n\u003cli\u003ePass 560R, Appliance Pass Labels, A5 sheet round\u003c\/li\u003e\n\u003cli\u003e\u003cbr\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434187042901,"sku":"Fluke 6200-2 UK","price":712641.6,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/F_6200_2uk_01a_h_1500x1000_1.jpg?v=1598866069"},{"product_id":"fluke-pass500s-appliance-pass-labels-rectangular","title":"Fluke  PASS500S Appliance Pass Labels (rectangular)","description":"\u003cp\u003ePASS 500S  PASS 500S,APPLIANCE PASS LABELS,A5 SHEET ROUND\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434187468885,"sku":"Fluke PASS500S","price":20473.2,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/70_2a0c3363-f6a8-4958-a6e8-7993f33be361.jpg?v=1591797679"},{"product_id":"fluke-pass560r-appliance-pass-labels-round","title":"Fluke  PASS560R Appliance Pass Labels (round)","description":"\u003cp\u003ePASS 560R  PASS 560R,APPLIANCE PASS LABELS 560,A5 SHEET ROUND\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434187501653,"sku":"Fluke PASS560R","price":20908.8,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/69....jpg?v=1591797428"},{"product_id":"fluke-1630-2-fc-earth-ground-loop-and-leakage-clamp","title":"Fluke 1630-2 FC Earth Ground Loop and Leakage Clamp, with Fluke Connect","description":"\u003ch2\u003eProduct overview: Fluke 1630-2 FC Earth Ground Clamp\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003eThe 1630-2 FC clamp measures earth ground loop resistances for multi-grounded systems using the dual-clamp jaw. This test technique eliminates the dangerous and time-consuming activity of disconnecting parallel grounds, as well as the process of finding suitable locations for auxiliary test stakes. You can also perform ground tests in places that were previously difficult: inside buildings, on power pylons or anywhere you don't have access to soil to place auxiliary test stakes.\u003c\/p\u003e\n\u003ch3\u003eEarth ground ac leakage current measurement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIdentify ac leakage currents without disconnecting the earth ground stake from the grounding system–ideal for system troubleshooting.\u003c\/li\u003e\n\u003cli\u003eRugged heavy-duty clamp jaw stays in alignment and in calibration even in every day, on-the-job industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogging measurements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe earth ground clamp saves time by automatically recording data at pre-set intervals\u003c\/li\u003e\n\u003cli\u003eSaves up to 32,760 measurements in memory at the set logging interval.\u003c\/li\u003e\n\u003cli\u003eSaves time by recording and storing measured values.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAlarm threshold\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUser-defined high\/low alarm limits, for rapid measurement evaluation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBand-pass filter\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSelectable band-pass filter function removes unwanted noise from the ac leakage current measurement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFluke Connect® Wireless System\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe 1630-2 FC supports the Fluke Connect Wireless System connects the clamp with an app on your smartphone or tablet (may not be available in all regions).\u003c\/li\u003e\n\u003cli\u003eYou can save these measurements, and images to Fluke Connect Cloud storage and share with your team.\u003c\/li\u003e\n\u003cli\u003eMaximize uptime and make confident maintenance decisions with data you can trust and trace.\u003c\/li\u003e\n\u003cli\u003eAccess baseline, historical and current measurements by asset.\u003c\/li\u003e\n\u003cli\u003eShare your measurement data using ShareLive™ video calls and emails.\u003c\/li\u003e\n\u003cli\u003eThe 1630-2 FC is part of a growing system of connected test tools and equipment maintenance software. Visit the website to learn more about the Fluke Connect system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 1630-2 FC Earth Ground Clamp\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eElectrical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage to earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAA alkaline IEC\/EN LR6 (x4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMore than 15 hours*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003csmall\u003e* In Ground Resistance measurement mode, with backlight turned off, and RF mode turned off\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e40 Hz to 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC\/EN 60529: IP30 with jaw closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eLCD\u003c\/td\u003e\n\u003ctd\u003eDigital reading\u003c\/td\u003e\n\u003ctd\u003e9999 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefresh rate\u003c\/td\u003e\n\u003ctd\u003e4 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-10 °C to + 50 °C\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20 °C to + 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNon condensing (\u0026lt;10 °C) (\u0026lt; 50 °F)  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e≤90% RH (at 10 °C to 30 °C [50 °F to 86 °F])\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e≤75% RH (at 30 °C to 40 °C [86 °F to 104 °F]) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e≤45% RH (at 40 °C to 50 °C [104 °F to 122 °F])\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e(Non condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 m (6561 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12 000 m (39,370 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e23 °C ±5 °C (73 °F ±9 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.15% x (specified accuracy)\/ °C (\u0026lt;18 °C or \u0026gt;28 °C [\u0026lt;64.4 °F or \u0026gt;82.4 °F])\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload indication\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData logging capacity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMinimum of 32,760 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData logging interval\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 second to 59 minutes and 59 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eDisplay reading specification with standard loop resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput (Ω)\u003c\/td\u003e\n\u003ctd\u003eMinimum\u003c\/td\u003e\n\u003ctd\u003eMaximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.474\u003c\/td\u003e\n\u003ctd\u003e0.417\u003c\/td\u003e\n\u003ctd\u003e0.531\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003ctd\u003e0.443\u003c\/td\u003e\n\u003ctd\u003e0.558\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e9.55\u003c\/td\u003e\n\u003ctd\u003e10.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e96\u003c\/td\u003e\n\u003ctd\u003e104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSafety\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC\/EN 61010-1: Pollution Degree 2 IEC\/EN 61557-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC\/EN 61010-2-032: CAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent clamp for leakage current measurements\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC\/EN 61557-13: Class 2, ≤30 A\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance to earth\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC\/EN 61557-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEffectiveness of thepProtective measures\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC\/EN 61557-16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eElectromagnetic compatibility (EMC)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eInternational\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61326-1: Portable Electromagnetic Environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCISPR 11: Group 1, Class B, IEC\/EN 61326-2-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKorea (KCC)\u003c\/td\u003e\n\u003ctd\u003eClass A equipment (Industrial Broadcast \u0026amp; Communications Equipment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSA (FCC)\u003c\/td\u003e\n\u003ctd\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eWireless Radio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2412 MHz to 2462 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt;10 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio frequency certification\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFCC ID:T68-FBLE IC:6627A-FBLE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor size\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e40 mm (1.57 in) approximately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e283 x 105 x 48 mm (11.1 x 4.1 x 1.9 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e880g (31 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOne year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eEarth Ground Loop Resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003csup\u003e1\u003c\/sup\u003e  ± (% of reading + Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.025 Ω to 0.249 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5% + 0.02 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.250 Ω to 0.999 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5% + 0.05 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.000 Ω to 9.999 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5% + 0.10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10.00 Ω to 49.99 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5% + 0.30 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50.00 Ω to 99.99 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5% + 0.50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100.0 Ω to 199.9 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3.0% + 1.0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200.0 Ω to 399.9 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.0% + 5.0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e400 Ω to 599 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10.0% + 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e600 Ω to 1500 Ω\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e20.00%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003csmall\u003e\u003csup\u003e1\u003c\/sup\u003e  Loop resistance with no inductance, conductor centered and perpendicular to jaw\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eEarth ground leakage current mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAutorange 50\/60 Hz, True rms, crest factor CF ≤3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eAccuracy\u003csup\u003e1\u003c\/sup\u003e  ± (% of reading + mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.200 mA to 3.999 mA\u003c\/td\u003e\n\u003ctd\u003e1 μA\u003c\/td\u003e\n\u003ctd\u003e2.0% + 0.05 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4.00 mA to 39.99 mA\u003c\/td\u003e\n\u003ctd\u003e10 μA\u003c\/td\u003e\n\u003ctd\u003e2.0% + 0.03 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40.0 mA to 399.9 mA\u003c\/td\u003e\n\u003ctd\u003e100 μA\u003c\/td\u003e\n\u003ctd\u003e2.0% + 0.3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.400 A to 3.999 A\u003c\/td\u003e\n\u003ctd\u003e1 mA\u003c\/td\u003e\n\u003ctd\u003e2.0% + 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4.00 A to 39.99 A\u003c\/td\u003e\n\u003ctd\u003e10 mA\u003c\/td\u003e\n\u003ctd\u003e2.0% + 30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\n\u003csmall\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eApplies to signal frequency\u003c\/small\u003e\n\u003cul\u003e\n\u003cli\u003e\u003csmall\u003e40 Hz to 1 kHz with filter set to OFF\u003c\/small\u003e\u003c\/li\u003e\n\u003cli\u003e\u003csmall\u003e40 Hz to 70 Hz with filter se to ON\u003c\/small\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"features-title\"\u003e\n\u003cbr\u003eKey features\u003c\/h2\u003e\n\u003cdiv aria-expanded=\"true\" data-readmore=\"\" id=\"keyfeature_content\"\u003e\n\u003cp\u003e\u003cspan\u003e“The Fluke 1630 is a MUST HAVE for those who are intent on improving the reliability of their systems and making it impervious to impulse damage. The Fluke 1630 is easy to use, highly accurate and an industry standard”\u003c\/span\u003e- verified purchaser\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not permit driving auxiliary test stakes.\u003c\/li\u003e\n\u003cli\u003eAC Leakage Current Measurement: Identify AC leakage without disconnecting your earth ground stake from the grounding system\u003c\/li\u003e\n\u003cli\u003eRugged: Heavy-duty clamp jaw stays in alignment and calibration on tough jobsites\u003c\/li\u003e\n\u003cli\u003eLogging measurement: Saves up to 32,760 measurements in memory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434187599957,"sku":"Fluke 1630-2 FC","price":922600.8,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/7_2181f49f-ac83-4446-a50a-3ea058ba7aa0.jpg?v=1599140033"},{"product_id":"pepperl-fuchs-smart-ex-2-dz1-smart-ex-2-dz1-div-1-zone-1-21-latest-available-android-firmware-release-with-camera-global-version","title":"Pepperl \u0026 Fuchs Smart-Ex 02 DZ1  Smart-Ex 02 DZ1 (DIV 1 \u0026 Zone 1\/21), latest available Android firmware release, with camera, global version","description":"\u003cp\u003eSmart-Ex 02 DZ1 (DIV 1 \u0026amp; Zone 1\/21), latest available Android firmware release, with camera, global version \u003cspan\u003e480986-100006\u003c\/span\u003e\u003c\/p\u003e\n\u003cul id=\"productfeatures\"\u003e\n\u003cli\u003eReplaceable SIM\u003c\/li\u003e\n\u003cli\u003eGlobal certificates - a common hardware platform\u003c\/li\u003e\n\u003cli\u003eAndroid™ 9 operating system\u003c\/li\u003e\n\u003cli\u003eUpgrade to Android™ 11 now available.\u003c\/li\u003e\n\u003cli\u003eWireless connections such as WWAN, 4G LTE, WLAN, etc.\u003c\/li\u003e\n\u003cli\u003eAndroid™ Enterprise Recommended verified device\u003c\/li\u003e\n\u003cli\u003eGPS\u003c\/li\u003e\n\u003cli\u003eNFC technology for wireless applications\u003c\/li\u003e\n\u003cli\u003eService contract\u003c\/li\u003e\n\u003cli\u003eProgrammable hardware buttons\u003c\/li\u003e\n\u003cli\u003eSpecial buttons for lone worker protection (LWP) applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"display: none;\" id=\"ext-mouse-move\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: none;\" id=\"ext-mouse-down\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: none;\" id=\"ext-mouse-up\"\u003e\u003c\/div\u003e","brand":"Pepperl \u0026 Fuchs","offers":[{"title":"Default Title","offer_id":32438367518805,"sku":"Smart-Ex 02 DZ1","price":1418700.8,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/58.png?v=1592834446"},{"product_id":"pepperl-fuchs-kfd2-stc4-ex1-2o-smart-transmitter-power-supply-output-current-sink-1-channel-isolated-barrier-24-v-dc-supply-power-rail-input-2-wire-and-3-wire-smart-transmitters-and-2-wire-smart-current-sources","title":"Pepperl \u0026 Fuchs  KFD2-STC4-EX1.2O  SMART Transmitter Power Supply, Output Current Sink\n1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources","description":"\u003cp\u003eSMART Transmitter Power Supply, Output Current Sink\u003cbr\u003e\n1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources, Signal splitter (1 input and 2 outputs), Dual output 0\/4 mA ... 20 mA, current sink, Terminal blocks with test sockets, Up to SIL 3 acc. to IEC 61508\u003c\/p\u003e","brand":"Pepperl \u0026 Fuchs","offers":[{"title":"Default Title","offer_id":32438367780949,"sku":"KFD2-STC4-EX1.2O","price":546678.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/24.png?v=1591876544"},{"product_id":"pepperl-fuchs-rd0-fb-ex4-fieldbarrier®-4-outputs-ex-ia-iic-fieldbarrier-in-zone-1-div-2-instruments-in-zone-0-1-div-1","title":"Pepperl \u0026 Fuchs  RD0-FB-EX4   FieldBarrier®\n4 outputs Ex ia IIC, FieldBarrier in Zone 1\/Div. 2, Instruments in Zone 0...1\/Div. 1","description":"\u003cp\u003eFieldBarrier® t25484\u003cbr\u003e 4 outputs Ex ia IIC, FieldBarrier in Zone 1\/Div. 2, Instruments in Zone 0...1\/Div. 1, Short circuit current limitation per output, For FOUNDATION Fieldbus H1 and PROFIBUS PA\u003c\/p\u003e","brand":"Pepperl \u0026 Fuchs","offers":[{"title":"Default Title","offer_id":32438368829525,"sku":"RD0-FB-EX4","price":772992.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/57.png?v=1592834367"},{"product_id":"pepperl-fuchs-kfd2-hmm-16-hart-multiplexer","title":"Pepperl \u0026 Fuchs  KFD2-HMM-16  HART Multiplexer Master16-channel","description":"\u003cp\u003eHART Multiplexer Master\u003cbr\u003e\n16-channel, 24 V DC supply (Power Rail), HART field device input (revision 5 to 7), Up to 15 KFD0-HMS-16 slave units can be connected, Up to SIL 3 acc. to IEC 61508\u003c\/p\u003e","brand":"Pepperl \u0026 Fuchs","offers":[{"title":"Default Title","offer_id":32438368927829,"sku":"KFD2-HMM-16","price":942282.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/20.png?v=1591801196"},{"product_id":"fluke-flk-ii900-sonic-industrial-imager","title":"Fluke ii900 Sonic Industrial Imager","description":"\u003ch2 data-mce-fragment=\"1\"\u003eProduct overview: Fluke ii900 Sonic Industrial Imager\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\" data-mce-fragment=\"1\"\u003e\n\u003cdiv id=\"product-overview\" data-mce-fragment=\"1\"\u003e\n\u003cdiv id=\"overview_content\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eEquipped with an array of microphones for an expanded field-of-view, the handheld Fluke ii900 Sonic Industrial Imager enables maintenance teams to quickly and accurately locate air, gas and vacuum leaks in compressed air systems; even in noisy environments. Specifically designed for noisy production facilities the new SoundSight™ technology is simple to learn and easy to implement. The 7” LCD touchscreen overlays a SoundMap™ on a visual image for quick leak location identification. The straightforward, intuitive interface allows technicians to isolate the sound frequency of the leak to filter out loud background noise. In a matter of hours, the team can inspect the entire plant – during peak operations. For the first time, you can quickly and easily identify the air leak repairs needed to ensure efficient operations and reduce utility bills. Images can be saved and exported for reporting purposes. Never leave air leaks unattended again.\u003c\/p\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv aria-expanded=\"true\" data-readmore=\"\" id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003eDo more with the same air compressors – delay the capital expense of purchasing an additional compressor\u003c\/li\u003e\n\u003cli\u003eEnsure proper air pressure to your pneumatic equipment\u003c\/li\u003e\n\u003cli\u003eLower utility costs\u003c\/li\u003e\n\u003cli\u003eReduce leak detection time\u003c\/li\u003e\n\u003cli\u003eImprove reliability in your production line\u003c\/li\u003e\n\u003cli\u003eLeakQ Report Generator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke ii900 Sonic Industrial Imager\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickablility\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSensors\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of microphones\u003c\/td\u003e\n\u003ctd\u003e64 digital MEMS microphones\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency band\u003c\/td\u003e\n\u003ctd\u003e2 kHz to 52 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound pressure sensitivity\u003c\/td\u003e\n\u003ctd\u003eDetects a 0.005 CFM leak at 100PSI from up to 32.8 feet\u003cbr\u003e(Detects a 2.5 cm\u003csup\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/sup\u003e\/sec leak at 7 bar from up to 10 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation distance range\u003c\/td\u003e\n\u003ctd\u003e0.5 to \u0026gt; 50 meters (1.6 to \u0026gt; 164 feet)*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of View\u003c\/td\u003e\n\u003ctd\u003e63 ° ± 5 °\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Frame Rate\u003c\/td\u003e\n\u003ctd\u003e12.5 FPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003csmall\u003e\u003cem\u003e*Depending on ambient conditions\u003c\/em\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eBuilt-in digital camera (visible light)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of View (FOV)\u003c\/td\u003e\n\u003ctd\u003e63 ° ± 5 °\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFocus\u003c\/td\u003e\n\u003ctd\u003eFixed lens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003cth\u003e7\" LCD with backlight, under-sunlight readable\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1280 x 800 (1,024,000 pixels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen\u003c\/td\u003e\n\u003ctd\u003eCapacitive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcoustic Image\u003c\/td\u003e\n\u003ctd\u003eYes, SoundMap™ image\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eImage storage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage capacity\u003c\/td\u003e\n\u003ctd\u003e20 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImage format\u003c\/td\u003e\n\u003ctd\u003eBlended visual and SoundMap™.JPG or .PNG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVideo format\u003c\/td\u003e\n\u003ctd\u003eBlended visual and SoundMap™.MP4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVideo length\u003c\/td\u003e\n\u003ctd\u003e5 minutes maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital export\u003c\/td\u003e\n\u003ctd\u003eUSB-C for data transfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eAcoustic Measurements\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e29.3 dB to 119.6 dB SPL (±2 dB) at 2 kHz\u003cbr\u003e21.9 dB to 112.3 db SPL (±2 dB) at 19 kHz\u003cbr\u003e36.6 db to 126.9 dB SPL (±2 dB) at 52 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto max\/min dB gain\u003c\/td\u003e\n\u003ctd\u003eAuto or manual, user selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency band selection\u003c\/td\u003e\n\u003ctd\u003eUser selectable through user-made presets or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSoftware\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEase of use\u003c\/td\u003e\n\u003ctd\u003eIntuitive user interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrend graphs\u003c\/td\u003e\n\u003ctd\u003eFrequency and dB scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpot markers\u003c\/td\u003e\n\u003ctd\u003edB level reading at center point of the image\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eBattery\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries (field-replaceable, rechargeable)\u003c\/td\u003e\n\u003ctd\u003eRechargeable Li-ion, Fluke BP291\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e6 hours (product includes spare battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery charging time\u003c\/td\u003e\n\u003ctd\u003e3 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery charging system\u003c\/td\u003e\n\u003ctd\u003eExternal dual-bay charger, EDBC 290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"width: 528px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" style=\"width: 511px;\"\u003eGeneral Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 158.667px;\"\u003eStandard palettes\u003c\/td\u003e\n\u003ctd style=\"width: 352.333px;\"\u003e3: Grayscale, Ironbow, Blue-Red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 158.667px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"width: 352.333px;\"\u003e0 °C to 40 °C (32 °F to 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 158.667px;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"width: 352.333px;\"\u003e-20 °C to 70 °C (-4 °F to 158 °F) Without batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 158.667px;\"\u003eRelative humidity\u003c\/td\u003e\n\u003ctd style=\"width: 352.333px;\"\u003e10 % to 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 158.667px;\"\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd style=\"width: 352.333px;\"\u003e186 mm x 322 mm x 68 mm (7.3 inches x 12.7 inches x 2.7 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 158.667px;\"\u003eWeight (battery included)\u003c\/td\u003e\n\u003ctd style=\"width: 352.333px;\"\u003e1.7 kg (3.75 pounds)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 158.667px;\"\u003eMain unit rating\u003c\/td\u003e\n\u003ctd style=\"width: 352.333px;\"\u003eIP40 protection against particles 1mm or greater and dripping water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 158.667px;\"\u003eSensor head rating\u003c\/td\u003e\n\u003ctd style=\"width: 352.333px;\"\u003eIP51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 158.667px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"width: 352.333px;\"\u003e2 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 158.667px;\"\u003eSelf-diagnostic notification\u003c\/td\u003e\n\u003ctd style=\"width: 352.333px;\"\u003eArray-health test to identify when microphone array needs attention\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 158.667px;\"\u003eSupported languages\u003c\/td\u003e\n\u003ctd style=\"width: 352.333px;\"\u003eDutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 158.667px;\"\u003eRoHS compliant\u003c\/td\u003e\n\u003ctd style=\"width: 352.333px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSafety\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral Safety\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Compatibility (EMC) International\u003c\/td\u003e\n\u003ctd\u003eIEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2\u003cbr\u003eCISPR 11: Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKorea (KCC)\u003c\/td\u003e\n\u003ctd\u003eClass A Equipment (Industrial Broadcasting \u0026amp; Communication)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSA (FCC)\u003c\/td\u003e\n\u003ctd\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504296898645,"sku":"Fluke FLK-ii900","price":9679516.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/fluke-ii900-sonic-industrial-imager.jpg?v=1600851078"},{"product_id":"fluke-tix580-9hz-thermal-imager-640x480-9-hz-sr","title":"Fluke TIX580 9Hz Thermal Imager; 640x480; 9 HZ, SR","description":"\u003ch2 data-mce-fragment=\"1\"\u003eProduct overview: Fluke TiX580 Infrared Camera\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\" data-mce-fragment=\"1\"\u003e\n\u003cdiv id=\"product-overview\" data-mce-fragment=\"1\"\u003e\n\u003cdiv id=\"overview_content\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eDoes everyone in the plant turn to you? Are you the one who quickly can collect facts, understand issues and mold process and procedures to meet expensive decisions head-on? If so, you need an infrared camera that is as flexible and detail oriented as you are. That is why the TiX580 should always be within arm’s reach. Your day can take you anywhere:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eR\u0026amp;D lab\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eProduction floor\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eOff site, remote locations\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eTransmission and distribution lines (substations)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003eFrom quality assurance to preventive maintenance and outdoor inspections, everyday can bring a different environment and a different challenge for your thermal imager. With an unsurpassed level of detail in every infrared image and the ability to capture quality images of objects whether they are tiny and close to large and far overhead. The ergonomic design and neck strap make long inspection days easier. Outside the rotating screen lets you adjust to minimize glare and the touchscreen delivers a premium in-field viewing experience. The TiX580 has the tools accommodate your environment.\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eReal-time temperature graphs\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eRadiometric video recording\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAuto capture image sequence\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMatLab and LabView integration capabilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003eGet the most out of your TiX580 with Fluke Connect™ desktop software. Create professional reports in minutes while effic\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eEdit and optimize images\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCombine infrared and visible images for simpler analysis\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCreate detailed reports\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eOrganize and search images by asset, severity, and title\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRugged, superbly engineered 640 x 480 thermal imaging camera\u003c\/li\u003e\n\u003cli\u003eProvides large 5.7-inch responsive LCD touchscreen with 150% more viewing area than 3.5-inch screen\u003c\/li\u003e\n\u003cli\u003eFeatures 240° rotating screen for unmatched shooting flexibility\u003c\/li\u003e\n\u003cli\u003eProvides 4x the pixel data with on-camera SuperResolution to create a 1280 x 960 resolution image\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke TiX580 Infrared Camera\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"head\"\u003eKey features\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIFOV with standard lens (spatial resolution)\u003c\/td\u003e\n\u003ctd\u003e0.93 mRad, D:S 1065:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector resolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 (307,200 pixels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuperResolution\u003c\/td\u003e\n\u003ctd\u003eYes, on camera and in software. Captures and combines 4x the data to create a 1280 x 960 image\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultiSharp™ Focus\u003c\/td\u003e\n\u003ctd\u003eYes, focused near and far, throughout the field of view\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaserSharp® Auto Focus\u003c\/td\u003e\n\u003ctd\u003eYes, for consistently in-focus images. Every. Single. Time.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser distance meter\u003c\/td\u003e\n\u003ctd\u003eYes, calculates distance to the target for precisely focused images and displays distance on screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdvanced manual focus\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen display (capacitive)\u003c\/td\u003e\n\u003ctd\u003e5.7 inch (14.4 cm) landscape 640 x 480 LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRugged, ergonomic design\u003c\/td\u003e\n\u003ctd\u003e240 ° rotatable (articulating) lens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital zoom\u003c\/td\u003e\n\u003ctd\u003e2x, 4x, and 8x\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-calibrated Lenses\u003c\/td\u003e\n\u003ctd\u003ewide angle, 2x telephoto, 4x telephoto and 25 micron\/macro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n \n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"head\"\u003eTemperature measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature measurement range (not calibrated below -10 °C)\u003c\/td\u003e\n\u003ctd\u003e-20 °C to 1000 °C (-4 °F to 1832 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±2 °C or 2% (at 25 °C nominal, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal sensitivity (NETD)\u003csup\u003e*\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e≤ 0.05 °C at 30 °C target temp (50 mK)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-screen emissivity correction\u003c\/td\u003e\n\u003ctd\u003eYes (both value and table)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-screen reflected background temperature compensation\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-screen transmission correction\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLive line marker\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold\"\u003e\u003cspan class=\"small-font\"\u003e\u003csup\u003e*\u003c\/sup\u003eBest possible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n \n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"head\" style=\"width: 511px;\"\u003eWireless connectivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 511px;\"\u003eTo PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN (where available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151.333px;\"\u003eFluke Connect® app compatible\u003c\/td\u003e\n\u003ctd style=\"width: 359.667px;\"\u003eYes, connect your camera to your smartphone, and images taken automatically upload to the Fluke Connect app for saving and sharing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151.333px;\"\u003eFluke Connect Assets optional software\u003c\/td\u003e\n\u003ctd style=\"width: 359.667px;\"\u003eYes, assign images to assets and create work orders. Easily compare measurement types - whether mechanical, electrical or infrared images - in one location.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151.333px;\"\u003eFluke Connect Instant Upload\u003c\/td\u003e\n\u003ctd style=\"width: 359.667px;\"\u003eYes, connect your camera to your building's WiFi network, and images taken automatically upload to the Fluke Connect system for viewing on your smartphone or PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151.333px;\"\u003eFluke Connect tool compatible\u003c\/td\u003e\n\u003ctd style=\"width: 359.667px;\"\u003eYes, connects wirelessly to select Fluke Connect enabled tools and displays measurements on camera screen. Five simultaneous connections supported.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 151.333px;\"\u003eFluke Connect SmartView desktop software\u003c\/td\u003e\n\u003ctd style=\"width: 359.667px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n \n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"head\"\u003eIR-Fusion® technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAdds the context of the visible details to your infrared image\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoBlend™ mode\u003c\/td\u003e\n\u003ctd\u003eContinuously variable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePicture-In-Picture (PIP)\u003c\/td\u003e\n\u003ctd\u003e100%, 75%, 50%, 25% IR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in digital camera (visible light)\u003c\/td\u003e\n\u003ctd\u003e5 MP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n \n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" class=\"head\" style=\"width: 504px;\"\u003eLenses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 156.333px;\"\u003eStandard lens\u003c\/td\u003e\n\u003ctd style=\"width: 163.667px;\"\u003eIFOV (spatial resolution)\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003e0.93 mRad, D:S 1065:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 163.667px;\"\u003eField of view\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003e34 °H x 24 °V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 163.667px;\"\u003eMinimum focus distance\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003e15 cm (approx. 6 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 163.667px;\"\u003eIR-Fusion® technology\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003ePicture-in-picture and full screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 156.333px;\"\u003eOptional 2x telephoto smart lens\u003c\/td\u003e\n\u003ctd style=\"width: 163.667px;\"\u003eIFOV\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003e0.33 mRad. D:S is 2145.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 163.667px;\"\u003eField of view\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003e12 °H x 8.5 °V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 163.667px;\"\u003eMinimum focus distance\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003e45 cm (approx. 18 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 163.667px;\"\u003eIR-Fusion® technology\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003ePicture-in-picture and full screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 156.333px;\"\u003eOptional wide-angle smart lens\u003c\/td\u003e\n\u003ctd style=\"width: 163.667px;\"\u003eIFOV\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003e1.85 mRad, D:S is 525:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 163.667px;\"\u003eField of view\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003e48 °H x 34 °V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 163.667px;\"\u003eMinimum focus distance\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003e15 cm (approx. 6 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 163.667px;\"\u003eIR-Fusion® technology\u003c\/td\u003e\n\u003ctd style=\"width: 184px;\"\u003eFull screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n \n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"head\"\u003eLevel and span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSmooth auto and manual scaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen adjustable level\/span\u003c\/td\u003e\n\u003ctd\u003eYes. Span and level can be easily and quickly set by simply touching the screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFast auto toggle between manual and auto modes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFast auto-rescale in manual mode\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum span (in manual mode)\u003c\/td\u003e\n\u003ctd\u003e2.0 °C (3.6 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum span (in auto mode)\u003c\/td\u003e\n\u003ctd\u003e3.0 °C (5.4 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n \n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"head\" style=\"width: 511px;\"\u003eData storage and image capture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.333px;\"\u003eExtensive memory options\u003c\/td\u003e\n\u003ctd style=\"width: 360.667px;\"\u003eRemovable 4 GB micro SD memory card, 4 GB internal flash memory, save to USB flash drive capability, upload to Fluke Cloud for permanent storage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.333px;\"\u003eImage file formats\u003c\/td\u003e\n\u003ctd style=\"width: 360.667px;\"\u003eNon-radiometric (.bmp, .jpeg), or fully radiometric (.is2); no analysis software required for non-radiometric (.bmp, .jpg) files\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.333px;\"\u003eMemory review\u003c\/td\u003e\n\u003ctd style=\"width: 360.667px;\"\u003eThumbnail and fullscreen review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.333px;\"\u003eSoftware\u003c\/td\u003e\n\u003ctd style=\"width: 360.667px;\"\u003eFluke Connect SmartView software - full analysis and reporting software and Fluke Connect system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.333px;\"\u003eExport file formats with Fluke Connect software\u003c\/td\u003e\n\u003ctd style=\"width: 360.667px;\"\u003eBitmap (.bmp), GIF, JPEG, PNG, TIFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.333px;\"\u003eVoice annotation\u003c\/td\u003e\n\u003ctd style=\"width: 360.667px;\"\u003e60 seconds maximum recording time per image; reviewable playback on camera\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.333px;\"\u003eIR-PhotoNotes™\u003c\/td\u003e\n\u003ctd style=\"width: 360.667px;\"\u003eYes (5 images)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.333px;\"\u003eAdvanced text annotation\u003c\/td\u003e\n\u003ctd style=\"width: 360.667px;\"\u003eYes. Including standard shortcuts as well as user programmable options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.333px;\"\u003eVideo recording\u003c\/td\u003e\n\u003ctd style=\"width: 360.667px;\"\u003eStandard and radiometric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.333px;\"\u003eFile formats video\u003c\/td\u003e\n\u003ctd style=\"width: 360.667px;\"\u003eNon-radiometric (MPEG - encoded .AVI) and fully-radiometric (.IS3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.333px;\"\u003eRemote display viewing\u003c\/td\u003e\n\u003ctd style=\"width: 360.667px;\"\u003eYes, see the live stream of the camera display on your PC, smartphone, or TV monitor. Via USB, WiFi hotspot, or WiFi network to Fluke Connect SmartView software on a PC; via WiFi hotspot to the Fluke Connect app on a smartphone; or via HDMI to a TV monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.333px;\"\u003eRemote control operation\u003c\/td\u003e\n\u003ctd style=\"width: 360.667px;\"\u003eYes, through Fluke Connect SmartView desktop software or Fluke Connect mobile app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.333px;\"\u003eAuto capture (temperature and interval)\u003c\/td\u003e\n\u003ctd style=\"width: 360.667px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.333px;\"\u003eMATLAB® and LabVIEW® tool boxes\u003c\/td\u003e\n\u003ctd style=\"width: 360.667px;\"\u003eIntegrate camera data, infrared video and images into these software platforms to support R\u0026amp;D analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n \n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"head\"\u003eBattery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries (field-replaceable, rechargeable)\u003c\/td\u003e\n\u003ctd\u003eTwo lithium ion smart battery packs with five-segment LED display to show charge level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e2-3 hours per battery (Actual life varies depending on settings and usage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery charge time\u003c\/td\u003e\n\u003ctd\u003e2.5 hours to full charge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery charging system\u003c\/td\u003e\n\u003ctd\u003eTwo-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC operation\u003c\/td\u003e\n\u003ctd\u003eAC operation with included power supply (100 V AC to 240 V AC, 50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower saving\u003c\/td\u003e\n\u003ctd\u003eUser selectable sleep and power off modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n \n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"head\"\u003eColor palettes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard palettes\u003c\/td\u003e\n\u003ctd\u003e8: Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltra Contrast™ palettes\u003c\/td\u003e\n\u003ctd\u003e8: Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n \n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"head\" style=\"width: 510px;\"\u003eGeneral specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eFrame rate\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003e60 Hz or 9 Hz versions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eLaser pointer\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eLED light (torch)\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eColor alarms (temperature alarms)\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003eHigh temperature, low temperature, and isotherms (within range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eCenter-point temperature measurement\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eSpot temperature\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003eHot and cold spot markers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eUser-definable spot markers\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003e3 user-definable spot markers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eCenter box\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003eExpandable-contractible measurement box with MIN-MAX-AVG temp display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eInfrared spectral band\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003e7.5 μm to 14 μm (long wave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003e-10 °C to +50 °C (14 °F to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003e-20 °C to +50 °C (-4 °F to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eRelative humidity\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003e10% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eSafety\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003eIEC 61010-1: Overvoltage category II, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003eIEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eAustralian RCM\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003eIEC 61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eUS FCC\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003eCFR 47, Part 15 Subpart B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eVibration\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003e0.03 g2\/Hz (3.8 g), 2.5 g IEC 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eShock\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003e25 g, IEC 60068-2-29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eDrop\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003e25 g, IEC 68-2-29\/Engineered to withstand 1 meter (3.3 feet) drop with standard lens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003e27.3 x 15.9 x 9.7 cm (10.8 x 6.3 x 3.8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eWeight (battery included)\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003e1.54 kg (3.4 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eEnclosure rating\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003eIEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all directions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003eTwo-years (standard), extended warranties are available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eRecommended calibration cycle\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003eTwo-years (assumes normal operation and normal aging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 139.667px;\"\u003eSupported languages\u003c\/td\u003e\n\u003ctd style=\"width: 370.333px;\"\u003eCzech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504297324629,"sku":"Fluke TIX580 9Hz","price":8583256.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/tix580.jpg?v=1599127745"},{"product_id":"fluke-ti450-sf6-60hz-sf6-gas-leak-detection-thermal-imager","title":"Fluke Ti450 SF6 60Hz SF6 Gas leak detection, Thermal Imager","description":"\u003ch2\u003e\u003cstrong data-mce-fragment=\"1\"\u003eProduct Overview: Fluke Ti450 SF6 Gas Detector\/Thermal Imager\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInfrared for every day. SF\u003csub data-mce-fragment=\"1\"\u003e6\u003c\/sub\u003e gas detection when you need it.\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eIncrease efficiency and save money with a top performing infrared camera that delivers pinpoint, state-of-the-art SF\u003csub data-mce-fragment=\"1\"\u003e6 \u003c\/sub\u003edetection - conduct two critical functions with a single tool. Best of all, it's affordable enough to own, so you can conduct infrared and gas inspections whenever and wherever you want without having to pay heavy rental charges or hire expensive contractors. \u003cstrong data-mce-fragment=\"1\"\u003e\u003cem data-mce-fragment=\"1\"\u003eTwo tools in one. At a one of a kind price.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDesigned for dependability.\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eUsing the technology from Fluke's top performing pistol grip camera, the Fluke Ti450 SF6 easily switches from infrared to gas mode. Making it easy to change modes on the fly when you are in the field.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTwo critical solutions in one remarkable IR camera.\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003eThe Ti450 SF6 Gas Leak Detector tips the scales on performance and affordability. With its pistol grip comfort and point-and-shoot convenience, even the tough spots become easy to diagnose. With the added feature of SF\u003csub data-mce-fragment=\"1\"\u003e6\u003c\/sub\u003e pinpoint detection, you can get the analysis you need anytime, anywhere.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eCompanies are no longer stuck in the challenging position of having to perform inspections, tracking SF\u003csub data-mce-fragment=\"1\"\u003e6\u003c\/sub\u003e leaks and managing the extremely high costs of buying or renting the equipment.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDetects and pinpoints the exact location of the SF6 leak – without shutting down equipment\u003c\/li\u003e\n\u003cli\u003eQuick entry\/exit button allowing quick toggling between gas imaging and infrared mode\u003c\/li\u003e\n\u003cli\u003e320 x 240 resolution for gas and infrared images; SuperResolution increases to 640 x 480, only in infrared mode\u003c\/li\u003e\n\u003cli\u003eGet in-focus images in both infrared and gas modes with a touch of a button with LaserSharp® Auto Focus\u003c\/li\u003e\n\u003cli\u003eWirelessly connect your camera to the Fluke Connect® system to make faster decisions. Team members can see the same data and collaborate on identifying the problem or authorize work before you've left the inspection site.\u003c\/li\u003e\n\u003cli\u003eNo need for pencil and notebook:\u003c\/li\u003e\n\u003cli\u003eIR PhotoNotes™ annotation system captures digital images of equipment details, e.g. serial numbers and surrounding area conditions\u003c\/li\u003e\n\u003cli\u003eRecord any additional notes with voice annotation and save them with the image\u003c\/li\u003e\n\u003cli\u003eSee additional details with optional smart lenses – no calibration required when swapping them between compatible cameras\u003c\/li\u003e\n\u003cli\u003eOptimize images, perform analytics, generate quick, customizable reports and export images to the format of your choice with SmartView® desktop software, included with your purchase\u003cbr\u003eCapture clear, accurate infrared images focused throughout the entire field of view with MultiSharp™ Focus\u003c\/li\u003e\n\u003cli\u003eSmall and lightweight, fits easily into your tool box\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504298766421,"sku":"Fluke Ti450 SF6 60Hz","price":8500976.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/fluke-ti450-sf6-gas-detector.jpg?v=1599128948"},{"product_id":"fluke-434-ii-power-quality-and-energy-analyzer","title":"Fluke 434-II Power Quality and Energy Analyzer","description":"\u003ch2\u003eProduct overview: Fluke 434-II and 435-II Power Quality and Energy Analyzers\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003eThe Fluke 434-II Energy Analyzer is designed to help you minimize downtime, quickly troubleshoot power quality issues and easily discover the costs of wasted energy. Downtime is expensive and getting the data you need to solve to critical power quality problems quickly is key. The 434-II and 435-II Analyzer’s measurement process and data output have been optimized to help you access the most critical information easily.\u003c\/p\u003e\n\u003cp\u003eMultiple parameters are measured simultaneously and displayed in formats that quickly describe overall power quality health. The detailed information helps you make better maintenance decisions—whether you’re trying to reduce energy waste, find the source of power quality issues or see how motor startups are affecting your electrical system. Data can be accessed as simple digital values, trend graphs (for fast insight into changes over time), waveforms, or phasor diagrams. The data can also be analyzed and organized into tabular formats. Detailed event data allows you to see the magnitude, duration and time stamping of anomalies enabling you to rapidly correlate the problems you are experiencing in your facility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Loss Calculator—\u003c\/strong\u003eCalculate money lost to energy waste in terms of real dollars.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg alt=\"Fluke 430 Series II Energy Loss Calculator\" class=\" lazyloaded\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/energy_waste_calculator_2016.jpg\" title=\"Fluke 430 Series II Energy Loss Calculator\" width=\"320\"\u003e\n\u003cfigcaption\u003eFluke 430 Series II Energy Loss Calculator\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cp\u003eIt’s a simple fact, poor power quality can have a big impact on the bottom line. The Fluke 434-II Energy Analyzer and Fluke 435-II Power Quality and Energy Analyzer enable you to identify issues and measure energy loss giving you specific insight into the amount of loss in dollars. The Energy Loss Calculator helps you better understand your energy consumption by creating associations between things like effective power and poor power quality characteristics such as reactive power, unbalance, distortion, or neutral current. These power quality and energy analyzers also offer users the flexibility to input cable length and diameter to calculate loss due to conductor sizing (or use AUTO mode if cable specifications are unknown) and enter up to four unique time-dependent daily rates (kWh) for more accurate calculations. Armed with this critical data, users can easily justify the investment necessary to take countermeasures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Power Quality Health—\u003c\/strong\u003eAt-a-glance power quality health data in real-time so you have the data you need, when you need it\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg alt=\"Power wave data capture\" class=\" lazyloaded\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/Monitor_320px_x_240px.jpg\" title=\"Power wave data capture\" width=\"320\"\u003e\n\u003cfigcaption\u003ePower wave data capture\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe Fluke 434-II Energy Analyzer and 435-II Power Quality and Energy Analyzer utilize an integrated Power Quality Health summary that gives you an at-a-glance view of a complete range of power quality issues in real time. With a simple graphical presentation, complete with tolerance limits, you can quickly discover which power quality problems may be present on your electrical system. If you don’t know where to start or what problems might exist, the advanced Power Quality Health summary simplifies the task and serves as a comprehensive starting point for further troubleshooting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower Inverter Efficiency\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePower inverters take dc current and transform it into ac current, or vice versa. But, what percentage of that power going into the inverter comes out as usable current? The Fluke 434-II and 435-II Analyzers have an integrated power inverter efficiency mode that allows users to better understand power inverter performance. Nothing is ever 100 % efficient, and a power inverter’s efficiency will vary depending on how much power is being used at the time (with the efficiency generally being greater when more power is being used). Inverters can also lose performance over time and need to be checked. By comparing the input power with the output power, you can determine the system efficiency. With the Power Inverter Efficiency feature you can discover just how good your inverter is at converting your dc power to ac (or vice versa).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAutoTrend—\u003c\/strong\u003eQuickly see the trend\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg alt=\"AutoTrend capability shows changes over time\" class=\" lazyloaded\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/v-a-hz-us.jpg\" title=\"AutoTrend capability shows changes over time\" width=\"320\"\u003e\n\u003cfigcaption\u003eAutoTrend capability shows changes over time\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cp\u003eWith a unique AutoTrend feature you can get fast insight into power quality changes over time. Every displayed reading is automatically and continuously recorded without having to set up threshold levels or having to manually start the process so you can quickly view trends in voltage, current, frequency, power, harmonics or flicker on all three phases plus neutral.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Power Quality Functions, Unprecedented Energy Analysis Capabilities\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePower quality issues can affect the operation of critical loads and have a negative impact on your bottom line. Think of the Fluke 435-II Power Quality and Energy Analyzer as your insurance policy. Calculate the cost of wasted energy due to poor power quality and troubleshoot the source of power quality or motor performance issues all with a single test tool designed to give you the data you need to quickly get to the root of the problem.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWrapped in a lightweight, rugged package, the Fluke 434-II Energy Analyzer and 435-II Power Quality and Energy Analyzer are the ideal portable power quality instruments.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQuickly see how much money you’re losing due to energy waste in terms of real dollars\u003c\/li\u003e\n\u003cli\u003eGet at-a-glance power quality health data in real-time so you can make better maintenance decisions\u003c\/li\u003e\n\u003cli\u003eMeasure all three phases and neutral with the included flexible current probes\u003c\/li\u003e\n\u003cli\u003eEasily see how motor startups are affecting electrical system performance\u003c\/li\u003e\n\u003cli\u003eHighest safety rating in the industry: 600 V CAT IV\/1000 V CAT III rated for use at the service entrance\u003c\/li\u003e\n\u003cli\u003eFluke Connect® compatible* – view data locally on the instrument, via Fluke Connect mobile app and PowerLog 430-II desktop software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe Fluke 430-II Series Power Quality Analyzers\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 434-II Energy Analyzer helps you understand your overall energy consumption and quantify how much energy loss is costing your facility. The Fluke 435-II Power Quality and Energy Analyzer includes the same great features of the 434-II while adding advanced power quality functionality for more in depth troubleshooting. If you need the same advanced functionality as the 435-II a higher frequency, the Fluke 437-II is the must-have power quality analyzer for 400 Hz power systems. Lastly, the Fluke 438-II Power Quality and Motor Analyzer includes all the power quality and energy analysis capabilities that the Fluke 435-II has as well as the ability to measure mechanical motor parameters such as motor speed, torque and mechanical power without the need of mechanical sensors.\u003c\/p\u003e\n\u003ctable style=\"width: 528px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 81px;\"\u003e\u003cstrong\u003eFluke 434-II\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 77.6667px;\"\u003e\u003cstrong\u003eFluke 435-II\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 86.3333px;\"\u003e\u003cstrong\u003eFluke 437-II\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 77px;\"\u003e\u003cstrong\u003eFluke 438-II\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003ePower Measurements\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 81px;\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 77.6667px;\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 86.3333px;\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 77px;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003ePower Quality Measurements\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 81px;\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 77.6667px;\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 86.3333px;\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 77px;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eIEC61000-4-30 Compliance\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 81px;\"\u003eClass S\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 77.6667px;\"\u003eClass A\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 86.3333px;\"\u003eClass A\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 77px;\"\u003eClass A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003ePower, Energy \u0026amp; Loss Calculator\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 81px;\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 77.6667px;\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 86.3333px;\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 77px;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eMonitor \u0026amp; Trending\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 81px;\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 77.6667px;\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 86.3333px;\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 77px;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eInrush, Inverter Efficiency\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 81px;\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 77.6667px;\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 86.3333px;\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 77px;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eAdvanced Analysis; Event Waveforms, Flicker, Transients, Mains Signaling, and Power Wave\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 81px;\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 77.6667px;\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 86.3333px;\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 77px;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eShipboard Power \u0026amp; 400Hz\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 81px;\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 77.6667px;\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 86.3333px;\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 77px;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eMotor Electrical \u0026amp; Mechanical Analysis\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 81px;\"\u003e(Optional)\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 77.6667px;\"\u003e(Optional)\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 86.3333px;\"\u003e(Optional)\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 77px;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161px;\"\u003eWiFi SD Card Combo\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 81px;\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 77.6667px;\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 86.3333px;\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\" style=\"width: 77px;\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cp\u003eAnalyze power quality issues, calculate the costs of wasted energy and prevent downtime with the Fluke 434-II Energy Analyzer and Fluke 435-II Power Quality and Energy Analyzer.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced power quality health—\u003c\/strong\u003eAt-a-glance power quality health data in real time so you can make better maintenance decisions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy loss calculator—\u003c\/strong\u003eDiscover the costs of energy loss specifically caused by poor power quality\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighest safety rating in industry—\u003c\/strong\u003eCAT III 1000 V \/ CAT IV 600 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 434-II and 435-II Power Quality and Energy Analyzers\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eVolt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eModel\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMeasurement Range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eVrms (AC + DC)\u003c\/td\u003e\n\u003ctd\u003e434-II\u003c\/td\u003e\n\u003ctd\u003e1 V to 1000 V phase to neutral\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e±0.1% of nominal voltage\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e435-II\u003c\/td\u003e\n\u003ctd\u003e1 V to 1000 V phase to neutral\u003c\/td\u003e\n\u003ctd\u003e0.01 V\u003c\/td\u003e\n\u003ctd\u003e±0.1% of nominal voltage\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eVpk\u003c\/td\u003e\n\u003ctd\u003e1 Vpk to 1400 Vpk\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003ctd\u003e5% of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eVoltage Crest Factor (CF)\u003c\/td\u003e\n\u003ctd\u003e1.0 \u0026gt; 2.8\u003c\/td\u003e\n\u003ctd\u003e0.01\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eVrms½\u003c\/td\u003e\n\u003ctd\u003e434-II\u003c\/td\u003e\n\u003ctd\u003e1 V to 1000 V phase to neutral\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e± 1 % of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e434-II and 435-II\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e±0.2% of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eVfund\u003c\/td\u003e\n\u003ctd\u003e434-II\u003c\/td\u003e\n\u003ctd\u003e1 V to 1000 V phase to neutral\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e± 0.5 % of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e435-II\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e± 0.1 % of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eAmps (accuracy excluding clamp accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eAmps (AC + DC)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei430-Flex 1x \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A to 6000 A\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ei430-Flex 10x\u003c\/td\u003e\n\u003ctd\u003e0.5 A to 600 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1mV\/A 1x\u003c\/td\u003e\n\u003ctd\u003e5 A to 2000 A\u003c\/td\u003e\n\u003ctd\u003e1A\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1mV\/A 10x\u003c\/td\u003e\n\u003ctd\u003e0.5 A A to 200 A (AC only)\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eApk\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei430-Flex\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e8400 Apk\u003c\/td\u003e\n\u003ctd\u003e1 Arms\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1mV\/A\u003c\/td\u003e\n\u003ctd\u003e5500 Apk\u003c\/td\u003e\n\u003ctd\u003e1 Arms\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eA Crest Factor (CF)\u003c\/td\u003e\n\u003ctd\u003e1 to 10\u003c\/td\u003e\n\u003ctd\u003e0.01\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eAmps½\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei430-Flex 1x\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A to 6000 A\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003ctd\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ei430-Flex 10x\u003c\/td\u003e\n\u003ctd\u003e0.5 A to 600 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1mV\/A 1x\u003c\/td\u003e\n\u003ctd\u003e5 A to 2000 A\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003ctd\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1mV\/A 10x\u003c\/td\u003e\n\u003ctd\u003e0.5 A A to 200 A (AC only)\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eAfund\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei430-Flex 1x\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A to 6000 A\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ei430-Flex 10x\u003c\/td\u003e\n\u003ctd\u003e0.5 A to 600 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1mV\/A 1x\u003c\/td\u003e\n\u003ctd\u003e5 A to 2000 A\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1mV\/A 10x\u003c\/td\u003e\n\u003ctd\u003e0.5 A A to 200 A (AC only)\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eHz\u003c\/td\u003e\n\u003ctd\u003eFluke 434 @ 50 Hz Nominal\u003c\/td\u003e\n\u003ctd class=\"nobold\"\u003e42.50 Hz to 57.50 Hz\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003c\/td\u003e\n\u003ctd\u003e±0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke 434 @ 60 Hz Nominal\u003c\/td\u003e\n\u003ctd\u003e51.00 Hz to 69.00 Hz\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003c\/td\u003e\n\u003ctd\u003e±0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke 435 @ 50 Hz Nominal\u003c\/td\u003e\n\u003ctd\u003e42.500 Hz to 57.500 Hz\u003c\/td\u003e\n\u003ctd\u003e0.001 Hz\u003c\/td\u003e\n\u003ctd\u003e±0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluke 435 @ 60 Hz Nominal\u003c\/td\u003e\n\u003ctd\u003e51.00 Hz to 69.00 Hz\u003c\/td\u003e\n\u003ctd\u003e0.001 Hz\u003c\/td\u003e\n\u003ctd\u003e±0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003ePower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eWatts (VA, var)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei430-Flex\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003emax 6000 MW\u003c\/td\u003e\n\u003ctd\u003e0.1 W to 1 MW\u003c\/td\u003e\n\u003ctd\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 mV\/A\u003c\/td\u003e\n\u003ctd\u003emax 2000 MW\u003c\/td\u003e\n\u003ctd\u003e0.1 W to 1 MW\u003c\/td\u003e\n\u003ctd\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ePower Factor (Cos j\/DPF)\u003c\/td\u003e\n\u003ctd\u003e0 to 1\u003c\/td\u003e\n\u003ctd\u003e0.001\u003c\/td\u003e\n\u003ctd\u003e±0.1% @ nominal load conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eEnergy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ekWh (kVAh, kvarh)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei430-Flex 10x\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDepends on clamp scaling and V nominal\u003c\/td\u003e\n\u003ctd\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Loss\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei430-Flex 10x\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDepends on clamp scaling and V nominal\u003c\/td\u003e\n\u003ctd\u003e±1% ±10 counts Excluding line resistance accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eHarmonics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eHarmonic Order (n)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eDC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eInter-Harmonic Order (n)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eOFF, 1 to 50 Grouping: Harmonic and Interharmonic subgroups according to IEC 61000-4-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eVolts %\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ef\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±0.1% ±n x 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003er\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±0.1% ±n x 0.4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute\u003c\/td\u003e\n\u003ctd\u003e0.0 to 1000 V\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e±5%\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD\u003c\/td\u003e\n\u003ctd\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±2.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eAmps %\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ef\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±0.1% ±n x 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003er\u003c\/td\u003e\n\u003ctd\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±0.1% ±n x 0.4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute\u003c\/td\u003e\n\u003ctd\u003e0.0 to 600 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD\u003c\/td\u003e\n\u003ctd\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±2.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eWatts %\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ef or r\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±n x 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute\u003c\/td\u003e\n\u003ctd\u003eDepends on clamp scaling and V nominal\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e±5% ±n x 2% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD\u003c\/td\u003e\n\u003ctd\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ePhase Angle\u003c\/td\u003e\n\u003ctd\u003e-360° to +0°\u003c\/td\u003e\n\u003ctd\u003e1°\u003c\/td\u003e\n\u003ctd\u003e±n x 1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eFlicker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ePlt, Pst, Pst (1 min) Pinst\u003c\/td\u003e\n\u003ctd\u003e0.00 to 20.00\u003c\/td\u003e\n\u003ctd\u003e0.01\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eUnbalance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eVolts %\u003c\/td\u003e\n\u003ctd\u003e0.0% to 20.0%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAmps %\u003c\/td\u003e\n\u003ctd\u003e0.0% to 20.0%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eMains Signaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eThreshold Levels\u003c\/td\u003e\n\u003ctd\u003eThreshold, limits and signaling duration is programable for two signaling frequencies\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSignaling Frequency\u003c\/td\u003e\n\u003ctd\u003e60 Hz to 3000 Hz\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRelative V %\u003c\/td\u003e\n\u003ctd\u003e0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.10%\u003c\/td\u003e\n\u003ctd\u003e±0.4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAbsolute V3s (3 second avg.)\u003c\/td\u003e\n\u003ctd\u003e0.0 V to 1000 V\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e±5% of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eDesign Rugged, shock proof with integrated protective holster Drip and dust proof IP51 according to IEC60529 when used in tilt stand position Shock and vibration Shock 30 g, vibration: 3 g sinusoid, random 0.03 g 2 \/Hz according to MIL-PRF-28800F Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eBrightness: 200 cd\/m 2 typ. using power adapter, 90 cd\/m 2 typical using battery power Size: 127 x 88 mm (153 mm\/6.0 in diagonal) LCD Resolution: 320 x 240 pixels Contrast and brightness: user-adjustable, temperature compensated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e16GB Wi-Fi SD card for standard models or 8GB SD card for \/INTL models (SDHC compliant, FAT32 formatted), up to 32GB optionally. Screen save and multiple data memories for storing data including recordings (dependent on memory size).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal-Time Clock\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eTime and date stamp for Trend mode, Transient display, System Monitor and event capture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eEnvironmental\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0°C ~ +40°C; +40°C ~ +50°C excl. battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-20°C ~ +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e+10°C ~ +30°C: 95% RH non-condensing\u003cbr\u003e+30°C ~ +40°C: 75% RH non-condensing\u003cbr\u003e+40°C ~ +50°C: 45% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Altitude\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eUp to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V\u003cbr\u003eUp to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V\u003cbr\u003eMaximum storage altitude 12 km (40,000 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectro-Magnetic-Compatibility (EMC)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eEN 61326 (2005-12) for emission and immunity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaces\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eMini-USB-B, Isolated USB port for PC connectivity SD card slot accessible behind instrument battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eThree years (parts and labor) on main instrument, one year on accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"5\"\u003e1. ±5% if ≥ 1% of nominal voltage ±0.05% of nominal voltage if \u0026lt; 1% of nominal voltage\u003cbr\u003e2. 50Hz\/60Hz nominal frequency according to IEC 61000-4-30\u003cbr\u003e3. 400Hz measurements are not supported for Flicker, Mains Signaling and Monitor Mode\u003cbr\u003e4. For nominal voltage 50 V to 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504304730197,"sku":"Fluke 434-II","price":2861892.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/fluke_435_ii.png?v=1598945139"},{"product_id":"fluke-435-ii-power-quality-energy-analyzer","title":"Fluke 435-II Power Quality\u0026 Energy Analyzer","description":"\u003ch2\u003eProduct overview: Fluke 434-II and 435-II Power Quality and Energy Analyzers\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003eThe Fluke 435-II Power Quality \u0026amp; Energy Analyzer is designed to help you minimize downtime, quickly troubleshoot power quality issues and easily discover the costs of wasted energy. Downtime is expensive and getting the data you need to solve to critical power quality problems quickly is key. The 434-II and 435-II Analyzer’s measurement process and data output have been optimized to help you access the most critical information easily.\u003c\/p\u003e\n\u003cp\u003eMultiple parameters are measured simultaneously and displayed in formats that quickly describe overall power quality health. The detailed information helps you make better maintenance decisions—whether you’re trying to reduce energy waste, find the source of power quality issues or see how motor startups are affecting your electrical system. Data can be accessed as simple digital values, trend graphs (for fast insight into changes over time), waveforms, or phasor diagrams. The data can also be analyzed and organized into tabular formats. Detailed event data allows you to see the magnitude, duration and time stamping of anomalies enabling you to rapidly correlate the problems you are experiencing in your facility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Loss Calculator—\u003c\/strong\u003eCalculate money lost to energy waste in terms of real dollars.\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg alt=\"Fluke 430 Series II Energy Loss Calculator\" class=\"lazyloaded\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/energy_waste_calculator_2016.jpg\" title=\"Fluke 430 Series II Energy Loss Calculator\" width=\"320\"\u003e\n\u003cfigcaption\u003eFluke 430 Series II Energy Loss Calculator\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cp\u003eIt’s a simple fact, poor power quality can have a big impact on the bottom line. The Fluke 434-II Energy Analyzer and Fluke 435-II Power Quality and Energy Analyzer enable you to identify issues and measure energy loss giving you specific insight into the amount of loss in dollars. The Energy Loss Calculator helps you better understand your energy consumption by creating associations between things like effective power and poor power quality characteristics such as reactive power, unbalance, distortion, or neutral current. These power quality and energy analyzers also offer users the flexibility to input cable length and diameter to calculate loss due to conductor sizing (or use AUTO mode if cable specifications are unknown) and enter up to four unique time-dependent daily rates (kWh) for more accurate calculations. Armed with this critical data, users can easily justify the investment necessary to take countermeasures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Power Quality Health—\u003c\/strong\u003eAt-a-glance power quality health data in real-time so you have the data you need, when you need it\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg alt=\"Power wave data capture\" class=\"lazyloaded\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/Monitor_320px_x_240px.jpg\" title=\"Power wave data capture\" width=\"320\"\u003e\n\u003cfigcaption\u003ePower wave data capture\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe Fluke 434-II Energy Analyzer and 435-II Power Quality and Energy Analyzer utilize an integrated Power Quality Health summary that gives you an at-a-glance view of a complete range of power quality issues in real time. With a simple graphical presentation, complete with tolerance limits, you can quickly discover which power quality problems may be present on your electrical system. If you don’t know where to start or what problems might exist, the advanced Power Quality Health summary simplifies the task and serves as a comprehensive starting point for further troubleshooting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower Inverter Efficiency\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePower inverters take dc current and transform it into ac current, or vice versa. But, what percentage of that power going into the inverter comes out as usable current? The Fluke 434-II and 435-II Analyzers have an integrated power inverter efficiency mode that allows users to better understand power inverter performance. Nothing is ever 100 % efficient, and a power inverter’s efficiency will vary depending on how much power is being used at the time (with the efficiency generally being greater when more power is being used). Inverters can also lose performance over time and need to be checked. By comparing the input power with the output power, you can determine the system efficiency. With the Power Inverter Efficiency feature you can discover just how good your inverter is at converting your dc power to ac (or vice versa).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAutoTrend—\u003c\/strong\u003eQuickly see the trend\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg alt=\"AutoTrend capability shows changes over time\" class=\"lazyloaded\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/v-a-hz-us.jpg\" title=\"AutoTrend capability shows changes over time\" width=\"320\"\u003e\n\u003cfigcaption\u003eAutoTrend capability shows changes over time\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cp\u003eWith a unique AutoTrend feature you can get fast insight into power quality changes over time. Every displayed reading is automatically and continuously recorded without having to set up threshold levels or having to manually start the process so you can quickly view trends in voltage, current, frequency, power, harmonics or flicker on all three phases plus neutral.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Power Quality Functions, Unprecedented Energy Analysis Capabilities\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePower quality issues can affect the operation of critical loads and have a negative impact on your bottom line. Think of the Fluke 435-II Power Quality and Energy Analyzer as your insurance policy. Calculate the cost of wasted energy due to poor power quality and troubleshoot the source of power quality or motor performance issues all with a single test tool designed to give you the data you need to quickly get to the root of the problem.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWrapped in a lightweight, rugged package, the Fluke 434-II Energy Analyzer and 435-II Power Quality and Energy Analyzer are the ideal portable power quality instruments.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQuickly see how much money you’re losing due to energy waste in terms of real dollars\u003c\/li\u003e\n\u003cli\u003eGet at-a-glance power quality health data in real-time so you can make better maintenance decisions\u003c\/li\u003e\n\u003cli\u003eMeasure all three phases and neutral with the included flexible current probes\u003c\/li\u003e\n\u003cli\u003eEasily see how motor startups are affecting electrical system performance\u003c\/li\u003e\n\u003cli\u003eHighest safety rating in the industry: 600 V CAT IV\/1000 V CAT III rated for use at the service entrance\u003c\/li\u003e\n\u003cli\u003eFluke Connect® compatible* – view data locally on the instrument, via Fluke Connect mobile app and PowerLog 430-II desktop software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe Fluke 430-II Series Power Quality Analyzers\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 434-II Energy Analyzer helps you understand your overall energy consumption and quantify how much energy loss is costing your facility. The Fluke 435-II Power Quality and Energy Analyzer includes the same great features of the 434-II while adding advanced power quality functionality for more in depth troubleshooting. If you need the same advanced functionality as the 435-II a higher frequency, the Fluke 437-II is the must-have power quality analyzer for 400 Hz power systems. Lastly, the Fluke 438-II Power Quality and Motor Analyzer includes all the power quality and energy analysis capabilities that the Fluke 435-II has as well as the ability to measure mechanical motor parameters such as motor speed, torque and mechanical power without the need of mechanical sensors.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003eFluke 434-II\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003eFluke 435-II\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003eFluke 437-II\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003eFluke 438-II\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Measurements\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Quality Measurements\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIEC61000-4-30 Compliance\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eClass S\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eClass A\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eClass A\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eClass A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower, Energy \u0026amp; Loss Calculator\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitor \u0026amp; Trending\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush, Inverter Efficiency\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdvanced Analysis; Event Waveforms, Flicker, Transients, Mains Signaling, and Power Wave\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipboard Power \u0026amp; 400Hz\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Electrical \u0026amp; Mechanical Analysis\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e(Optional)\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e(Optional)\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e(Optional)\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiFi SD Card Combo\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cp\u003eAnalyze power quality issues, calculate the costs of wasted energy and prevent downtime with the Fluke 434-II Energy Analyzer and Fluke 435-II Power Quality and Energy Analyzer.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced power quality health—\u003c\/strong\u003eAt-a-glance power quality health data in real time so you can make better maintenance decisions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy loss calculator—\u003c\/strong\u003eDiscover the costs of energy loss specifically caused by poor power quality\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighest safety rating in industry—\u003c\/strong\u003eCAT III 1000 V \/ CAT IV 600 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 434-II and 435-II Power Quality and Energy Analyzers\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 479px;\"\u003eVolt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 104.667px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e\u003cb\u003eModel\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e\u003cb\u003eMeasurement Range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 104.667px;\"\u003eVrms (AC + DC)\u003c\/td\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e434-II\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e1 V to 1000 V phase to neutral\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±0.1% of nominal voltage\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e435-II\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e1 V to 1000 V phase to neutral\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.01 V\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±0.1% of nominal voltage\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 164px;\"\u003eVpk\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e1 Vpk to 1400 Vpk\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e1 V\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e5% of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 164px;\"\u003eVoltage Crest Factor (CF)\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e1.0 \u0026gt; 2.8\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.01\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 104.667px;\"\u003eVrms½\u003c\/td\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e434-II\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e1 V to 1000 V phase to neutral\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e± 1 % of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e434-II and 435-II\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±0.2% of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 104.667px;\"\u003eVfund\u003c\/td\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e434-II\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e1 V to 1000 V phase to neutral\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e± 0.5 % of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e435-II\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e± 0.1 % of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 479px;\"\u003eAmps (accuracy excluding clamp accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 104.667px;\"\u003eAmps (AC + DC)\u003c\/td\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e\u003cb\u003ei430-Flex 1x \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e5 A to 6000 A\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e1 A\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003ei430-Flex 10x\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e0.5 A to 600 A\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1 A\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e1mV\/A 1x\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e5 A to 2000 A\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e1A\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e1mV\/A 10x\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e0.5 A A to 200 A (AC only)\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1 A\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 104.667px;\"\u003eApk\u003c\/td\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e\u003cb\u003ei430-Flex\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e8400 Apk\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e1 Arms\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e1mV\/A\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e5500 Apk\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e1 Arms\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 164px;\"\u003eA Crest Factor (CF)\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e1 to 10\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.01\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 104.667px;\"\u003eAmps½\u003c\/td\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e\u003cb\u003ei430-Flex 1x\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e5 A to 6000 A\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e1 A\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003ei430-Flex 10x\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e0.5 A to 600 A\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1 A\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e1mV\/A 1x\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e5 A to 2000 A\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e1 A\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e1mV\/A 10x\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e0.5 A A to 200 A (AC only)\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1 A\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 104.667px;\"\u003eAfund\u003c\/td\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e\u003cb\u003ei430-Flex 1x\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e5 A to 6000 A\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e1 A\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003ei430-Flex 10x\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e0.5 A to 600 A\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1 A\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e1mV\/A 1x\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e5 A to 2000 A\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e1 A\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e1mV\/A 10x\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e0.5 A A to 200 A (AC only)\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1 A\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 479px;\"\u003eHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 104.667px;\"\u003eHz\u003c\/td\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003eFluke 434 @ 50 Hz Nominal\u003c\/td\u003e\n\u003ctd class=\"nobold\" style=\"width: 135px;\"\u003e42.50 Hz to 57.50 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.01 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003eFluke 434 @ 60 Hz Nominal\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e51.00 Hz to 69.00 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.01 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003eFluke 435 @ 50 Hz Nominal\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e42.500 Hz to 57.500 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.001 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003eFluke 435 @ 60 Hz Nominal\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e51.00 Hz to 69.00 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.001 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 479px;\"\u003ePower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 104.667px;\"\u003eWatts (VA, var)\u003c\/td\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e\u003cb\u003ei430-Flex\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003emax 6000 MW\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1 W to 1 MW\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e1 mV\/A\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003emax 2000 MW\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1 W to 1 MW\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 164px;\"\u003ePower Factor (Cos j\/DPF)\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e0 to 1\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.001\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±0.1% @ nominal load conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 479px;\"\u003eEnergy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 104.667px;\"\u003ekWh (kVAh, kvarh)\u003c\/td\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e\u003cb\u003ei430-Flex 10x\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 218px;\"\u003eDepends on clamp scaling and V nominal\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 104.667px;\"\u003eEnergy Loss\u003c\/td\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e\u003cb\u003ei430-Flex 10x\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 218px;\"\u003eDepends on clamp scaling and V nominal\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±1% ±10 counts Excluding line resistance accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 479px;\"\u003eHarmonics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 164px;\"\u003eHarmonic Order (n)\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 315px;\"\u003eDC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 164px;\"\u003eInter-Harmonic Order (n)\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 315px;\"\u003eOFF, 1 to 50 Grouping: Harmonic and Interharmonic subgroups according to IEC 61000-4-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 104.667px;\"\u003eVolts %\u003c\/td\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e\u003cb\u003ef\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1%\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±0.1% ±n x 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e\u003cb\u003er\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1%\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±0.1% ±n x 0.4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003eAbsolute\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e0.0 to 1000 V\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±5%\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003eTHD\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1%\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±2.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 104.667px;\"\u003eAmps %\u003c\/td\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e\u003cb\u003ef\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1%\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±0.1% ±n x 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003er\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1%\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±0.1% ±n x 0.4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003eAbsolute\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e0.0 to 600 A\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1 A\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003eTHD\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1%\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±2.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 104.667px;\"\u003eWatts %\u003c\/td\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003e\u003cb\u003ef or r\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1%\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±n x 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003eAbsolute\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003eDepends on clamp scaling and V nominal\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±5% ±n x 2% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 59.3333px;\"\u003eTHD\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1%\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 164px;\"\u003ePhase Angle\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e-360° to +0°\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e1°\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±n x 1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 479px;\"\u003eFlicker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 164px;\"\u003ePlt, Pst, Pst (1 min) Pinst\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e0.00 to 20.00\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.01\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 479px;\"\u003eUnbalance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 164px;\"\u003eVolts %\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e0.0% to 20.0%\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1%\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 164px;\"\u003eAmps %\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e0.0% to 20.0%\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1%\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 479px;\"\u003eMains Signaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 164px;\"\u003eThreshold Levels\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003eThreshold, limits and signaling duration is programable for two signaling frequencies\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 164px;\"\u003eSignaling Frequency\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e60 Hz to 3000 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 164px;\"\u003eRelative V %\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e0% to 100%\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.10%\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±0.4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 164px;\"\u003eAbsolute V3s (3 second avg.)\u003c\/td\u003e\n\u003ctd style=\"width: 135px;\"\u003e0.0 V to 1000 V\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd style=\"width: 97px;\"\u003e±5% of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 479px;\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 104.667px;\"\u003eCase\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 374.333px;\"\u003eDesign Rugged, shock proof with integrated protective holster Drip and dust proof IP51 according to IEC60529 when used in tilt stand position Shock and vibration Shock 30 g, vibration: 3 g sinusoid, random 0.03 g 2 \/Hz according to MIL-PRF-28800F Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 104.667px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 374.333px;\"\u003eBrightness: 200 cd\/m 2 typ. using power adapter, 90 cd\/m 2 typical using battery power Size: 127 x 88 mm (153 mm\/6.0 in diagonal) LCD Resolution: 320 x 240 pixels Contrast and brightness: user-adjustable, temperature compensated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 104.667px;\"\u003eMemory\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 374.333px;\"\u003e16GB Wi-Fi SD card for standard models or 8GB SD card for \/INTL models (SDHC compliant, FAT32 formatted), up to 32GB optionally. Screen save and multiple data memories for storing data including recordings (dependent on memory size).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 104.667px;\"\u003eReal-Time Clock\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 374.333px;\"\u003eTime and date stamp for Trend mode, Transient display, System Monitor and event capture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 479px;\"\u003eEnvironmental\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 104.667px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 374.333px;\"\u003e0°C ~ +40°C; +40°C ~ +50°C excl. battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 104.667px;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 374.333px;\"\u003e-20°C ~ +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 104.667px;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 374.333px;\"\u003e+10°C ~ +30°C: 95% RH non-condensing\u003cbr\u003e+30°C ~ +40°C: 75% RH non-condensing\u003cbr\u003e+40°C ~ +50°C: 45% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 104.667px;\"\u003eMaximum Operating Altitude\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 374.333px;\"\u003eUp to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V\u003cbr\u003eUp to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V\u003cbr\u003eMaximum storage altitude 12 km (40,000 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 104.667px;\"\u003eElectro-Magnetic-Compatibility (EMC)\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 374.333px;\"\u003eEN 61326 (2005-12) for emission and immunity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 104.667px;\"\u003eInterfaces\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 374.333px;\"\u003eMini-USB-B, Isolated USB port for PC connectivity SD card slot accessible behind instrument battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 104.667px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 374.333px;\"\u003eThree years (parts and labor) on main instrument, one year on accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" style=\"width: 479px;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"5\" style=\"width: 479px;\"\u003e1. ±5% if ≥ 1% of nominal voltage ±0.05% of nominal voltage if \u0026lt; 1% of nominal voltage\u003cbr\u003e2. 50Hz\/60Hz nominal frequency according to IEC 61000-4-30\u003cbr\u003e3. 400Hz measurements are not supported for Flicker, Mains Signaling and Monitor Mode\u003cbr\u003e4. For nominal voltage 50 V to 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504304795733,"sku":"Fluke 435-II","price":3639680.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/717fE60EVEL._AC_SX569.jpg?v=1598945519"},{"product_id":"fluke-437-ii-power-quality-energy-analyzer","title":"Fluke 437-II Power Quality\u0026 Energy Analyzer","description":"\u003ch2\u003eProduct overview: Fluke 437 Series II 400 Hz Power Quality Monitor and Energy Analyzer\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003eIf you’re dealing with aviation systems measuring key power quality parameters at 400Hz is a must. The Fluke 437-II provides that capability (and measures at 50 and 60Hz too) and is designed for users who need to quickly get to the source of the power quality problem, so they can minimize expensive downtime. The integrated shipboard power measurement system analyzes according to MIL-STD 1399 to automatically give a full evaluation of voltage, current and power according to the standard. This evaluation makes measurement and analysis as easy as can be. The measurement process, and the way the 437-II displays data has been optimized to provide to the most important information as quickly as possible. Multiple parameters are measured simultaneously and are displayed in formats that quickly describe overall power quality health while giving you the detailed information you need to make better maintenance decisions. Data can be quickly accessed as simple digital values, viewed as trend graphs that give you fast insight into changes over time, or viewed as waveforms and phasor diagrams or analyzed. Data can also be organized into tabular format for viewing events where the magnitude, duration and time stamp enable rapid correlation to the problems you are experiencing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLocating, Predicting, Preventing and Troubleshooting Power Quality Issues—\u003c\/strong\u003eUp to 400Hz\u003c\/p\u003e\n\u003cp\u003eHigher power frequencies mean smaller and lighter transformers and motors – a critical factor in avionic and military transport applications where weight is a primary concern. The Fluke 437 Series II Power Quality and Energy Analyzer can show you the cost of energy waste due to poor power quality and is ideal for characterizing power quality, conducting load studies and capturing hard-to-find voltage events over a user-defined period of time. Designed for capturing power quality measurements in avionic and military systems, Fluke 437 Series II is the must-have 400 Hz quality analyzer.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e400 Hz operation according to MIL-STD 1399 for use in avionic and military applications\u003c\/li\u003e\n\u003cli\u003eShipboard power measurement system analyzes according to MIL-STD 1399 to automatically give a full evaluation of voltage, current and power\u003c\/li\u003e\n\u003cli\u003eGet at-a-glance power quality health data in real-time so you can make better maintenance decisions\u003c\/li\u003e\n\u003cli\u003eMeasure all three phases and neutral with the included flexible current probes\u003c\/li\u003e\n\u003cli\u003eQuickly see how much money you’re losing due to energy waste in terms of real dollars\u003c\/li\u003e\n\u003cli\u003eEasily see how motor startups are affecting motor drive performance\u003c\/li\u003e\n\u003cli\u003eHighest safety rating in the industry: 600 V CAT IV\/1000 V CAT III rated for use at the service entrance\u003c\/li\u003e\n\u003cli\u003eFluke Connect® compatible* – view data locally on the instrument, via Fluke Connect mobile app and PowerLog 430-II desktop software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Power Quality Health—\u003c\/strong\u003eAt-a-glance power quality health data in real-time so you have the data you need, when you need it\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg alt=\"Power wave data capture\" class=\" lazyloaded\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/Monitor_320px_x_240px.jpg\" title=\"Power wave data capture\" width=\"320\"\u003e\n\u003cfigcaption\u003ePower wave data capture\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe Fluke 437-II Power Quality Monitor and Energy Analyzer utilizes an integrated Power Quality Health summary that gives you an at-a-glance view of a complete range of power quality issues in real time. With a simple graphical presentation, complete with tolerance limits, you can quickly discover which power quality problems may be present on your electrical system. If you don’t know where to start or what problems might exist, the advanced Power Quality Health summary will simplify the task and serves as a comprehensive starting point for further troubleshooting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePowerWave Data Capture—\u003c\/strong\u003eQuickly identify how motor and generator startups are impacting electrical system performance\u003c\/p\u003e\n\u003cp\u003eWith PowerWave data capture you can capture three-phase high resolution voltage and current waveforms for up to five minutes along with detailed RMS voltage and current values. By analyzing the interaction of these values over time you can correlate the effects of voltage, current and frequency during the critical startup of motors and generators. PowerWave even goes beyond the standard power quality measurements allowing you to record half cycle rms values on 8 channels, frequency and instantaneous power (Vrms1\/2, Arms1\/2, W, Hz and scope waveforms for voltage, amps and watts)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower Inverter Efficiency\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePower inverters take DC current and transform it into AC current, or vice versa. But, what percentage of that power going into the inverter comes out as usable current? The Fluke 437-II Power Monitor and Energy Analyzer has an integrated power inverter efficiency mode that allows users to better understand power inverter performance. Nothing is ever 100% efficient, and a power inverter’s efficiency will vary depending on how much power is being used at the time (with the efficiency generally being greater when more power is being used). Inverters can also lose performance over time and need to be checked. By comparing the input power with the output power, you can determine the system efficiency. With the Power Inverter Efficiency feature you can discover just how good your inverter is at converting your DC power to AC (or visa versa). Poor power efficiency may occur when the inverter is wrongly sized for the load.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAutoTrend—\u003c\/strong\u003eQuickly see the trend\u003c\/p\u003e\n\u003cfigure\u003e\u003cimg alt=\"AutoTrend capability shows changes over time\" class=\" lazyloaded\" src=\"https:\/\/dam-assets.fluke.com\/s3fs-public\/v-a-hz-us.jpg\" title=\"AutoTrend capability shows changes over time\" width=\"320\"\u003e\n\u003cfigcaption\u003eAutoTrend capability shows changes over time\u003c\/figcaption\u003e\n\u003c\/figure\u003e\n\u003cp\u003eWith a unique AutoTrend feature you can get fast insight into changes over time. Every displayed reading is automatically and continuously recorded without having to set up threshold levels or having to manually start the process so you can quickly view trends in voltage, current, frequency, power, harmonics or flicker on all three phases plus neutral.\u003c\/p\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cp\u003eThe Fluke 437-II series helps you locate, predict, prevent and troubleshoot Power Quality Issues – 50Hz, 60Hz and 400Hz\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e400 Hz operation for use in avionic and military applications\u003c\/li\u003e\n\u003cli\u003eShipboard power measurement system analyzes according to MIL-STD 1399 to automatically give a full evaluation of voltage, current and power\u003c\/li\u003e\n\u003cli\u003eAdvanced Power Quality Health— At-a-glance power quality health data in real-time so you have the data you need, when you need it\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 437 Series II 400 Hz Power Quality Monitor and Energy Analyzer\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" style=\"width: 488px;\"\u003eProduct Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003e\u003cb\u003eVolt\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e\u003cb\u003eModel\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e\u003cb\u003eMeasurement Range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eVrms (ac+dc)\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e1 V to 1000 V phase to neutral\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.01 V\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.1% of nominal voltage**** \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eVpk\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e1 Vpk to 1400 Vpk\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e1 V\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e5% of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eVoltage Crest Factor (CF)\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e1.0 \u0026gt; 2.8\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.01\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eVfund\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.1% of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 488px;\"\u003eAmps (accuracy excluding clamp accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 115px;\"\u003eAmps (ac+dc)\u003c\/td\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e\u003cb\u003ei430-Flex 1x \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e5 A to 6000 A\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e1 A\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.5% ± 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003ei430-Flex 10x\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.5 A to 600 A\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 A\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.5% ± 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e1mV\/A 1x\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e5 A to 2000 A\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e1A\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.5% ± 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e1mV\/A 10x\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.5 A A to 200 A (ac only)\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 A\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.5% ± 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 115px;\"\u003eApk\u003c\/td\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e\u003cb\u003ei430-Flex \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e8400 Apk \u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e1 Arms\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e1mV\/A\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e5500 Apk\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e1 Arms\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eA Crest Factor (CF)\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e1 to 10\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.01\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 115px;\"\u003eAmps½\u003c\/td\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e\u003cb\u003ei430-Flex 1x \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e5 A to 6000 A \u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e1 A \u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 1% ± 10 counts \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003ei430-Flex 10x\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.5 A to 600 A\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 A \u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 1% ± 10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e1mV\/A 1x  \u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e5 A to 2000 A \u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e1A \u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 1% ± 10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e1mV\/A 10x\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.5 A A to 200 A (ac only)\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 A\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 1% ± 10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 115px;\"\u003eAfund\u003c\/td\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e\u003cb\u003ei430-Flex 1x \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e5 A to 6000 A\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e1 A\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.5% ± 5 counts \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003ei430-Flex 10x \u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.5 A to 600 A\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 A\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.5% ± 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e1mV\/A 1x \u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e5 A to 2000 A\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e1A\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.5% ± 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e1mV\/A 10x \u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.5 A A to 200 A (ac only)\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 A\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.5% ± 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 488px;\"\u003eHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003e\u003cb\u003eFluke 437 @ 50 Hz nominal\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e42.500 Hz to 57.500 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.001 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eFluke 437 @ 60 Hz nominal \u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e51.000 Hz to 69.000 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.001 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eFluke 437 @ 400 Hz nominal\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e340.0 Hz to 460.0 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 488px;\"\u003ePower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 115px;\"\u003eWatts (VA, var)\u003c\/td\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e\u003cb\u003ei430-Flex \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003emax 6000 MW\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 W to 1 MW\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 1% ± 10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e1 mV\/A\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003emax 2000 MW\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 W to 1 MW\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 1% ± 10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003ePower Factor (Cos j\/DPF)\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0 to 1\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.001\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.1% @ nominal load conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 488px;\"\u003eEnergy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003ekWh (kVAh, kvarh)\u003c\/td\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e\u003cb\u003ei430-Flex 10x\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 177.333px;\"\u003eDepends on clamp scaling and V nominal\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 1% ± 10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003eEnergy Loss\u003c\/td\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e\u003cb\u003ei430-Flex 10x\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 177.333px;\"\u003eDepends on clamp scaling and V nominal\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 1% ± 10 counts Excluding line resistance accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 488px;\"\u003eHarmonics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eHarmonic Order (n)\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 302.333px;\"\u003eDC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eInter-Harmonic Order (n)\u003c\/td\u003e\n\u003ctd colspan=\"3\" style=\"width: 302.333px;\"\u003eOFF, 1 to 50 Grouping: Harmonic and Interharmonic subgroups according to IEC 61000-4-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 115px;\"\u003eVolts %\u003c\/td\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e\u003cb\u003ef\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 % to 100 %\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 %\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.1% ± n x 0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003er\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 % to 100 %\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 %\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.1% ± n x 0.4 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003eAbsolute\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 to 1000 V\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 5% *\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003eTHD\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 % to 100 %\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 %\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 2.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 115px;\"\u003eAmps %\u003c\/td\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e\u003cb\u003ef\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 % to 100 %\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 %\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.1% ± n x 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003er\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 % to 100 %\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 %\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.1% ± n x 0.4 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003eAbsolute\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 to 600 A\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 A\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 5% ± 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003eTHD\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 % to 100 %\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 %\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 2.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 115px;\"\u003eWatts %\u003c\/td\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003e\u003cb\u003ef or r \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 % to 100 %\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 %\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± n x 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003eAbsolute\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003eDepends on clamp scaling and V nominal \u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 5% ± n x 2 % ± 10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 70.6667px;\"\u003eTHD\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 % to 100 %  \u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 %\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003ePhase Angle\u003cb\u003e \u003c\/b\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e-360° to +0°\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e1°\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± n x 1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 488px;\"\u003eFlicker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003ePlt, Pst, Pst (1min) Pinst\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.00 to 20.00\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.01\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 488px;\"\u003eUnbalance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eVolts\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e%\u003c\/b\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 % to 20.0 %\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 %\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eAmps\u003cb\u003e\u003cspan\u003e \u003c\/span\u003e%\u003c\/b\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 % to 20.0 %\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1%\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 488px;\"\u003eMains Signaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eThreshold Levels\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003eThreshold, limits and signaling duration is programmable for two signaling frequencies\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e—\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eSignaling Frequency\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e60 Hz to 3000 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eRelative V%\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0 % to 100 %\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.10 %\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 0.4 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 185.667px;\"\u003eAbsolute V3s (3 second avg.)\u003c\/td\u003e\n\u003ctd style=\"width: 119.333px;\"\u003e0.0 V to 1000 V\u003c\/td\u003e\n\u003ctd style=\"width: 58px;\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd style=\"width: 125px;\"\u003e± 5 % of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 488px;\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003eCase\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003eDesign Rugged, shock proof with integrated protective holster Drip and dust proof IP51 according to IEC60529 when used in tilt stand position Shock and vibration Shock 30 g, vibration: 3 g sinusoid, random 0.03 g 2 \/Hz according to MIL-PRF-28800F Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003eBrightness: 200 cd\/m 2 typ. using power adapter, 90 cd\/m 2 typical using battery power Size: 127 mm x 88 mm (153 mm\/6.0 in diagonal) LCD Resolution: 320 x 240 pixels Contrast and brightness: user-adjustable, temperature compensated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003eMemory\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003e16GB Wi-Fi SD card for standard models or 8GB SD card for \/INTL models (SDHC compliant, FAT32 formatted), up to 32GB optionally. Screen save and multiple data memories for storing data including recordings (dependent on memory size).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003eReal-Time Clock\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003eTime and date stamp for Trend mode, Transient display, System Monitor and event capture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\" style=\"width: 488px;\"\u003eEnvironmental\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003e0 °C ~ +40 °C; +40 °C ~ +50 °C excl. battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003e-20 °C ~ +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003e+10 °C ~ +30 °C: 95% RH non-condensing\u003cbr\u003e+30 °C ~ +40 °C: 75% RH non-condensing\u003cbr\u003e+40 °C ~ +50 °C: 45% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003eMaximum Operating Altitude\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003eUp to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V\u003cbr\u003eUp to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V\u003cbr\u003eMaximum storage altitude 12 km (40,000 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003eElectro-Magnetic-Compatibility (EMC)\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003eEN 61326 (2005-12) for emission and immunity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003eInterfaces\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003eMini-USB-B, Isolated USB port for PC connectivity SD card slot accessible behind instrument battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003eThree years (parts and labor) on main instrument, one year on accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" style=\"width: 488px;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003e*\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003e ± 5 % if ≥ 1 % of nominal voltage ± 0.05 % of nominal voltage if \u0026lt; 1% of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003e**\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003e 50Hz\/60Hz nominal frequency according to IEC 61000-4-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003e***\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003e 400Hz measurements are not supported for Flicker, Mains Signaling and Monitor Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 115px;\"\u003e****\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 373px;\"\u003e For nominal voltage 50 V to 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504304894037,"sku":"Fluke 437-II","price":5359332.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/Fluke437-II_Main.jpg?v=1598947028"},{"product_id":"fluke-438-ii-power-quality-motor-analyzer","title":"Fluke 438-II Power Quality \u0026motor Analyzer","description":"\u003ch2\u003eProduct overview: Fluke 438-II Power Quality Analyzer \u0026amp; Motor Analyzer\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cstrong\u003eQuickly and easily discover electrical and mechanical performance of electric motors, and evaluate power quality with a single test tool\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 438-II Power Quality and Motor Analyzer adds key mechanical measurement capabilities for electric motors to the advanced power quality analysis functions of the\u003cspan\u003e \u003c\/span\u003eFluke 435 Series II Power Quality Analyzers  . Quickly and easily measure and analyze key electrical and mechanical performance parameters such as power, harmonics, unbalance, motor speed, torque and mechanical power without the need of mechanical sensors. Fluke 434-II, 435-II and 437-II Power Quality Analyzer users can add motor analysis capabilities to their existing units with the Fluke-438-II\/MA Motor Analyzer upgrade kit. The 438-II uses data from the motor rating plate for either NEMA or IEC rated motors to aid the calculation of the mechanical parameters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCalculates mechanical power and efficiency without mechanical sensors. Just connect to the input conductors\u003c\/li\u003e\n\u003cli\u003eMeasures electrical power parameters such as voltage, current, power, apparent power, power factor, harmonic distortion and unbalance to identify characteristics that impact motor efficiency\u003c\/li\u003e\n\u003cli\u003eIdentify power quality issues such as dips, swells, transients, harmonics and unbalance\u003c\/li\u003e\n\u003cli\u003eUses PowerWave data capture to capture fast RMS data, and show half-cycle averages and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.)\u003c\/li\u003e\n\u003cli\u003eOffers waveform capture function to capture 100\/120 cycles (50\/60 Hz) of each detected event, in all modes, without set-up\u003c\/li\u003e\n\u003cli\u003eUses automatic transient mode to capture waveform data at 200 kS\/s on all phases simultaneously up to 6 kV\u003c\/li\u003e\n\u003cli\u003eAutomatically calculate motor derating according to NEMA\/IEC guidelines\u003c\/li\u003e\n\u003cli\u003eFluke Connect® compatible so you can view data locally on the instrument, via Fluke Connect mobile app and PowerLog 430-II desktop software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cp\u003eThe 438-II Power Quality Analyzer \u0026amp; Motor Analyzer helps you effectively evaluate electrical and mechanical performance just by hooking up voltage and measuring current, providing you with an unprecedented level of data.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBrings key motor analysis parameters like speed, torque and mechanical power and calculates motor efficiency without mechanical sensors\u003c\/li\u003e\n\u003cli\u003eIncludes full power quality and electrical energy analyzer functionality\u003c\/li\u003e\n\u003cli\u003eHighest safety rating in industry; 1000 V CAT III \/ 600 V CAT IV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 438-II Power Quality Analyzer \u0026amp; Motor Analyzer\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cp\u003eAmps (accuracy excluding clamp accuracy)\u003c\/p\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eDrive Measurement Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Type\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e3 phase asynchronous (induction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eVariable Frequency Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Frequency Range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e40Hz to 70Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver\/Under Voltage from Nominal V\/f Curve (%)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-15% to +15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrier Frequency Range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2.5kHz–20kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eVariable speed drive technology that is covered by the 438-II\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eVSI only (voltage controlled) *\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eV\/f control, open-loop vector, closed loop vector, drives with encoders.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e40 to 70 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\u003csmall\u003e* VSI drives are the most common drives. The alternative CSI drives are used in higher power applications.\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eVariable speed drive technology NOT covered by the 438-II\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eCSI (current source inverter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotors type\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eSynchronous (DC, stepper, permanent magnet etc.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026lt;40 and \u0026gt;70 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eMechanical specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eMechanical measurements can be performed on direct online motors with a 3 wire connection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eMotor measurement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefault limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical motor\u003cbr\u003e\u003cbr\u003ePower\u003c\/td\u003e\n\u003ctd\u003e0.7 kW to 746 kW\u003cbr\u003e\u003cbr\u003e1 hp to 1000 hp\u003c\/td\u003e\n\u003ctd\u003e0.1 kW\u003cbr\u003e\u003cbr\u003e0.1 hp\u003c\/td\u003e\n\u003ctd\u003e±3%\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cbr\u003e\u003cbr\u003e±3%\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e100% = rated power\u003cbr\u003e\u003cbr\u003e100% = rated power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTorque\u003c\/td\u003e\n\u003ctd\u003e0 Nm to 10 000 Nm\u003cbr\u003e\u003cbr\u003e0 lb ft to 10 000 lb ft\u003c\/td\u003e\n\u003ctd\u003e0.1 Nm\u003cbr\u003e\u003cbr\u003e0.1 lb ft\u003c\/td\u003e\n\u003ctd\u003e±5%\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cbr\u003e\u003cbr\u003e±5%\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e100% = rated torque\u003cbr\u003e\u003cbr\u003e100% = rated torque\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003erpm\u003c\/td\u003e\n\u003ctd\u003e0 rpm to 3600 rpm\u003c\/td\u003e\n\u003ctd\u003e1 rpm\u003c\/td\u003e\n\u003ctd\u003e±3%\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e100% = rated rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.10%\u003c\/td\u003e\n\u003ctd\u003e±3%\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnbalance (NEMA)\u003c\/td\u003e\n\u003ctd\u003e0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.10%\u003c\/td\u003e\n\u003ctd\u003e±0.15%\u003c\/td\u003e\n\u003ctd\u003e5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonics Voltage\u003cbr\u003eFactor (NEMA)\u003c\/td\u003e\n\u003ctd\u003e0 to 0.20\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003e±1.5%\u003c\/td\u003e\n\u003ctd\u003e0.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnbalance Derating\u003cbr\u003eFactor\u003c\/td\u003e\n\u003ctd\u003e0.7 to 1.0\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003eindicative\u003c\/td\u003e\n\u003ctd\u003eNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonics Derating\u003cbr\u003eFactor\u003c\/td\u003e\n\u003ctd\u003e0.7 to 1.0\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003eindicative\u003c\/td\u003e\n\u003ctd\u003eNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal NEMA Derating\u003cbr\u003eFactor\u003c\/td\u003e\n\u003ctd\u003e0.5 to 1.0\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003eindicative\u003c\/td\u003e\n\u003ctd\u003eNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eNotes:\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eSupports motor design types NEMA A, B, C, D \u0026amp; E and IEC type H and N.\u003cbr\u003eRated torque is calculated from rated power and rated speed.\u003cbr\u003eUpdate rate of Motor Measurements is 1x per second.\u003cbr\u003eDefault Trend duration is 1 week.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\u003csmall\u003e\u003csup\u003e1\u003c\/sup\u003eAdd 5% error when selecting Motor design type Other\u003cbr\u003eSpecification valid for Motor Power \u0026gt; 30% of rated power\u003cbr\u003eSpecification valid at stable operating temperature. Run the motor for at least 1 hour at full load\u003cbr\u003e(2-3 hours if the motor is 50 HP or higher) to obtain stable temperature\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eProduct Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolt\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eModel\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMeasurement Range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVrms (AC + DC)\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 V to 1000 V phase to neutral\u003c\/td\u003e\n\u003ctd\u003e0.01 V\u003c\/td\u003e\n\u003ctd\u003e±0.1% of nominal voltage\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVpk\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 Vpk to 1400 Vpk\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003ctd\u003e5% of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Crest Factor (CF)\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.0 \u0026gt; 2.8\u003c\/td\u003e\n\u003ctd\u003e0.01\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVrms½\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e±0.2% of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVfund\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e±0.1% of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr colspan=\"5\"\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eAmps (AC + DC)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei430-Flex 1x \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A to 6000 A\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ei430-Flex 10x\u003c\/td\u003e\n\u003ctd\u003e0.5 A to 600 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1mV\/A 1x\u003c\/td\u003e\n\u003ctd\u003e5 A to 2000 A\u003c\/td\u003e\n\u003ctd\u003e1A\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1mV\/A 10x\u003c\/td\u003e\n\u003ctd\u003e0.5 A A to 200 A (AC only)\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eApk\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei430-Flex\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e8400 Apk\u003c\/td\u003e\n\u003ctd\u003e1 Arms\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1mV\/A\u003c\/td\u003e\n\u003ctd\u003e5500 Apk\u003c\/td\u003e\n\u003ctd\u003e1 Arms\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA Crest Factor (CF)\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 to 10\u003c\/td\u003e\n\u003ctd\u003e0.01\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eAmps½\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei430-Flex 1x\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A to 6000 A\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003ctd\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ei430-Flex 10x\u003c\/td\u003e\n\u003ctd\u003e0.5 A to 600 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1mV\/A 1x\u003c\/td\u003e\n\u003ctd\u003e5 A to 2000 A\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003ctd\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1mV\/A 10x\u003c\/td\u003e\n\u003ctd\u003e0.5 A A to 200 A (AC only)\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eAfund\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei430-Flex 1x\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A to 6000 A\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ei430-Flex 10x\u003c\/td\u003e\n\u003ctd\u003e0.5 A to 600 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1mV\/A 1x\u003c\/td\u003e\n\u003ctd\u003e5 A to 2000 A\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1mV\/A 10x\u003c\/td\u003e\n\u003ctd\u003e0.5 A A to 200 A (AC only)\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eHz\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eFluke 434 @ 50 Hz Nominal\u003c\/td\u003e\n\u003ctd class=\"nobold\"\u003e42.50 Hz to 57.50 Hz\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003c\/td\u003e\n\u003ctd\u003e±0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eFluke 434 @ 60 Hz Nominal\u003c\/td\u003e\n\u003ctd\u003e51.00 Hz to 69.00 Hz\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003c\/td\u003e\n\u003ctd\u003e±0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003ePower\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eWatts (VA, var)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei430-Flex\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003emax 6000 MW\u003c\/td\u003e\n\u003ctd\u003e0.1 W to 1 MW\u003c\/td\u003e\n\u003ctd\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 mV\/A\u003c\/td\u003e\n\u003ctd\u003emax 2000 MW\u003c\/td\u003e\n\u003ctd\u003e0.1 W to 1 MW\u003c\/td\u003e\n\u003ctd\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ePower Factor (Cos j\/DPF)\u003c\/td\u003e\n\u003ctd\u003e0 to 1\u003c\/td\u003e\n\u003ctd\u003e0.001\u003c\/td\u003e\n\u003ctd\u003e±0.1% @ nominal load conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eEnergy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ekWh (kVAh, kvarh)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei430-Flex 10x\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eDepends on clamp scaling and V nominal\u003c\/td\u003e\n\u003ctd\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eEnergy Loss\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei430-Flex 10x\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eDepends on clamp scaling and V nominal\u003c\/td\u003e\n\u003ctd\u003e±1% ±10 counts Excluding line resistance accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eHarmonics\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eHarmonic Order (n)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eDC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eInter-Harmonic Order (n)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eOFF, 1 to 50 Grouping: Harmonic and Interharmonic subgroups according to IEC 61000-4-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eVolts %\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ef\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±0.1% ±n x 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003er\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±0.1% ±n x 0.4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute\u003c\/td\u003e\n\u003ctd\u003e0.0 to 1000 V\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e±5%\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD\u003c\/td\u003e\n\u003ctd\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±2.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eAmps %\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ef\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±0.1% ±n x 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003er\u003c\/td\u003e\n\u003ctd\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±0.1% ±n x 0.4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute\u003c\/td\u003e\n\u003ctd\u003e0.0 to 600 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD\u003c\/td\u003e\n\u003ctd\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±2.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eWatts %\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ef or r\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±n x 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute\u003c\/td\u003e\n\u003ctd\u003eDepends on clamp scaling and V nominal\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e±5% ±n x 2% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD\u003c\/td\u003e\n\u003ctd\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Angle\u003c\/td\u003e\n\u003ctd\u003e-360° to +0°\u003c\/td\u003e\n\u003ctd\u003e1°\u003c\/td\u003e\n\u003ctd\u003e±n x 1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eFlicker\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ePlt, Pst, Pst (1 min) Pinst\u003c\/td\u003e\n\u003ctd\u003e0.00 to 20.00\u003c\/td\u003e\n\u003ctd\u003e0.01\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eUnbalance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eVolts %\u003c\/td\u003e\n\u003ctd\u003e0.0% to 20.0%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAmps %\u003c\/td\u003e\n\u003ctd\u003e0.0% to 20.0%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eMains Signaling\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eThreshold Levels\u003c\/td\u003e\n\u003ctd\u003eThreshold, limits and signaling duration is programable for two signaling frequencies\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSignaling Frequency\u003c\/td\u003e\n\u003ctd\u003e60 Hz to 3000 Hz\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRelative V %\u003c\/td\u003e\n\u003ctd\u003e0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.10%\u003c\/td\u003e\n\u003ctd\u003e±0.4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAbsolute V3s (3 second avg.)\u003c\/td\u003e\n\u003ctd\u003e0.0 V to 1000 V\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e±5% of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eGeneral Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eDesign Rugged, shock proof with integrated protective holster Drip and dust proof IP51 according to IEC60529 when used in tilt stand position Shock and vibration Shock 30 g, vibration: 3 g sinusoid, random 0.03 g 2 \/Hz according to MIL-PRF-28800F Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eBrightness: 200 cd\/m 2 typ. using power adapter, 90 cd\/m 2 typical using battery power Size: 127 x 88 mm (153 mm\/6.0 in diagonal) LCD Resolution: 320 x 240 pixels Contrast and brightness: user-adjustable, temperature compensated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e16GB Wi-Fi SD card for standard models or 8GB SD card for \/INTL models (SDHC compliant, FAT32 formatted), up to 32GB optionally. Screen save and multiple data memories for storing data including recordings (dependent on memory size).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal-Time Clock\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eTime and date stamp for Trend mode, Transient display, System Monitor and event capture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eEnvironmental\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0°C ~ +40°C; +40°C ~ +50°C excl. battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-20°C ~ +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e+10°C ~ +30°C: 95% RH non-condensing\u003cbr\u003e+30°C ~ +40°C: 75% RH non-condensing\u003cbr\u003e+40°C ~ +50°C: 45% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Altitude\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eUp to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V\u003cbr\u003eUp to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V\u003cbr\u003eMaximum storage altitude 12 km (40,000 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectro-Magnetic-Compatibility (EMC)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eEN 61326 (2005-12) for emission and immunity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaces\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eMini-USB-B, Isolated USB port for PC connectivity SD card slot accessible behind instrument battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eThree years (parts and labor) on main instrument, one year on accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\u003csmall\u003e1. ±5% if ≥ 1% of nominal voltage ±0.05% of nominal voltage if \u0026lt; 1% of nominal voltage\u003cbr\u003e2. 50Hz\/60Hz nominal frequency according to IEC 61000-4-30\u003cbr\u003e3. 400Hz measurements are not supported for Flicker, Mains Signaling and Monitor Mode\u003cbr\u003e4. For nominal voltage 50 V to 500 V\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504304992341,"sku":"Fluke 438-II","price":4379716.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/fluke-438-ii-basic-three-phase-power-quality-and-motor-analyzer-without-current-flexis-excludes-fc-wifi-sd-card.jpg?v=1598947432"},{"product_id":"fluke-1732-intl-energy-logger-international-version","title":"Fluke 1732\/INTL Energy Logger, international version","description":"\u003ch2 data-mce-fragment=\"1\"\u003eProduct overview: Fluke 1732 Three Phase Power Measurement Logger\u003c\/h2\u003e\n\u003cdiv data-mce-fragment=\"1\" id=\"fluke-product-display-overview\"\u003e\n\u003cdiv data-mce-fragment=\"1\" id=\"product-overview\"\u003e\n\u003cdiv data-mce-fragment=\"1\" id=\"overview_content\" itemprop=\"description\"\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003eThree phase power measurements made easy\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Fluke 1732 (without wifi) Three Phase Electrical Energy Logger delivers easy to use three phase power measurement data for discovering sources of electrical energy waste, overloaded circuits and help you perform routine load studies. Discover when and where energy in your facility is being consumed - from the service entrance to individual circuits. Access and share three phase power data remotely with your team via the Fluke Connect® app so you can maintain safer working distances and make critical decisions in real-time, reducing the need for protective equipment, site visits and check-ins.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eProfiling energy usage across your facility helps you identify opportunities for energy savings, and provides you with the data you need to act on them. The new Energy Analyze\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003esoftware package allows you to compare multiple data points over time to build a complete picture of energy usage, which is the first step to reduce the cost of your energy bill.\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eKey measurements:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eAutomatically capture and log voltage, current, power, power factor, energy and associated values\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eFluke Connect® compatible:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eView data locally on the instrument, via Fluke Connect mobile app and desktop software or through your facilities’ WiFi infrastructure\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eConvenient instrument powering:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePower instrument directly from the measured circuit\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eHighest safety rating in the industry:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e600 V CAT IV\/1000 V CAT III rated for use at the service entrance and downstream\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eMeasure all three phases:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eWith included 3 flexible current probes\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eComprehensive logging:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eMore than 20 separate logging sessions can be stored on the instruments. In fact, all measured values are automatically logged so you never loose measurement trends. They can even be reviewed during logging sessions and before downloading for real-time analysis\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eOptimized user interface:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eQuick, guided, graphical setup ensures you’re capturing the right data every time, and the intelligent verification function indicates correct connections have been made, reducing user uncertainty\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eBright, color touch screen:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003ePerform convenient in-the-field analysis and data checks with full graphical display\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eComplete “in-the-field\" setup through the front panel or Fluke Connect:\u003c\/strong\u003eNo need to return to the workshop for download and setup or to take a computer to the electrical panel\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003eFully integrated logging:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eConnect other Fluke Connect devices to the Fluke 1734 to simultaneously log up to two other measurement parameters, virtually any parameter available on a Fluke Connect wireless digital multimeter or module*\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cstrong data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eEnergy Analyze \u003c\/span\u003ePlus application software:\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003eDownload and analyze every detail of energy consumption with our automated reporting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e*Not all models are available in all countries. Check with your local Fluke representative.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWhich three-phase logger is right for you?\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003cth data-mce-fragment=\"1\"\u003e \u003c\/th\u003e\n\u003cth data-mce-fragment=\"1\" colspan=\"2\" align=\"center\"\u003eThree-phase Energy Loggers\u003c\/th\u003e\n\u003cth data-mce-fragment=\"1\" colspan=\"2\" align=\"center\"\u003eThree-phase Power Loggers\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003cth data-mce-fragment=\"1\"\u003eFeatures\u003c\/th\u003e\n\u003cth data-mce-fragment=\"1\" align=\"center\"\u003e1732 Energy Logger\u003c\/th\u003e\n\u003cth data-mce-fragment=\"1\" align=\"center\"\u003e1734 Energy Logger\u003c\/th\u003e\n\u003cth data-mce-fragment=\"1\" align=\"center\"\u003e1736 Power Logger\u003c\/th\u003e\n\u003cth data-mce-fragment=\"1\" align=\"center\"\u003e1738 Advanced Power Logger\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eLoad studies\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eEnergy assessments\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eNeutral Current, 4th current channel\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eHarmonics measurements\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eVoltage event capture\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePQ Health Graphical\u003cbr data-mce-fragment=\"1\"\u003eoverview (EN50160)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003eUpgrade package*\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eIEEE519 total harmonic distortion\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003eOptional\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eFully integrated logging with Fluke Connect®\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003eUpgrade package*\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003eUpgrade package*\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWiFi\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003eOptional\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWi-Fi \/ Bluetooth\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003eOptional\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003eOptional\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMagnetic probe set\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003eOptional\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003eOptional\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMagnetic hanger\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003eOptional\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003eOptional\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eConnection via WiFi router\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\" align=\"center\"\u003eRequires FREE software license available upon product registration.\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\" align=\"center\"\u003eRequires FREE software license available upon product registration.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv data-mce-fragment=\"1\" class=\"small-font\"\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e*Upgrade packages are available to upgrade existing 1732 Energy Loggers with the same features of the 1734 Energy logger, and to upgrade existing 1736 Power Loggers with the same features and capabilities of the 1738 Advanced Power Logger. Please note that 1732 and 1734 Energy Loggers cannot be upgraded with the functionality of 1736 and 1738 Power Loggers.\u003cbr data-mce-fragment=\"1\"\u003ePlease ask your distributor for more information about the upgrade package.\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\" class=\"small-font\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\" class=\"small-font\"\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003eDiscover sources of electrical energy waste, identify energy savings opportunities, and conduct load studies.\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey measurements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAutomatically capture and log voltage, current, power, power factor, energy and associated values\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvenient instrument powering:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYou can power the instrument directly from the measured circuit instead of mains outlets\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighest safety rating in the industry:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e600 V CAT IV\/1000 V CAT III rated for use at the service entrance and downstream\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 1732 Three Phase Power Measurement Logger\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"clickability\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"clickability\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\"\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\"\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e\u003cb\u003eIntrinsic Accuracy at Reference Conditions (% of Reading +% of Full Scale)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000 V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e±(0.2% + 0.01%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"8\"\u003e\u003cspan\u003eCurrent: Direct input\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cspan\u003e\u003cb\u003ei17xx-flex 1500 12\"\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e±(1% + 0.02%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e1500 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e±(1% + 0.02%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cspan\u003e\u003cb\u003ei17xx-flex 3000 24\"\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e300 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e±(1% + 0.03%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e3000 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e±(1% + 0.03%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cspan\u003e\u003cb\u003ei17xx-flex 6000 36\"\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e600 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e±(1.5% + 0.03%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e6000 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e±(1.5% + 0.03%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cspan\u003e\u003cb\u003ei40s-EL clamp\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e±(0.7% + 0.02%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e40 A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e±(0.7% + 0.02%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003eFrequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e42.5 Hz to 69 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.01 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e±(0.1%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003eAuxillary input\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±10 V dc\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 mV\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e±(0.2% + 0.02%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003eVoltage min\/max\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000 V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e±(1% + 0.1%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003eCurrent min\/max\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDefined by accessory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDefined by accessory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e±(5% + 0.2%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003eTHD on voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e±0.5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003eTHD on current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cspan\u003e±0.5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\"\u003e\u003cspan\u003eIntrinsic Uncertainty ±(% of reading +% of range)¹\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cspan\u003e\u003cb\u003eInfluence quantity\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eiFlex1500-12\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eiFlex3000-24\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003eiFlex6000-36\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003ei40S-EL\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003e150 A \/ 1500 A\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003e300 A \/ 3000 A\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003e600 A \/ 6000 A\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cb\u003e4 A \/ 40 A\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eActive Power P\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePF ≥ 0.99\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2% + 0.005%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2% + 0.0075%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.7% + 0.0075%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2% + 0.005%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eActive Energy E\u003csub\u003ea\u003c\/sub\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePF ≥ 0.99\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2% + 0.005%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2% + 0.0075%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.7% + 0.0075%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2% + 0.005%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApparent power S\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 ≤ PF ≤ 1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2% + 0.005%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2% + 0.0075%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.7% + 0.0075%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2% + 0.005%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApparent Energy E\u003csub\u003eap\u003c\/sub\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 ≤ PF ≤ 1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2% + 0.005%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2% + 0.0075%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.7% + 0.0075%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2% + 0.005%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eReactive power Q\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 ≤ PF ≤ 1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u003cspan\u003e2.5% of measured apparent power\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eReactive Energy E\u003csub\u003er\u003c\/sub\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 ≤ PF ≤ 1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u003cspan\u003e2.5% of measured apparent power\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Factor PF\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u003cspan\u003e±0.025\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplacement Power Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u003cspan\u003e±0.025\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDBF\/cosϕ\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u003cspan\u003e±0.025\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAdditional uncertainty in% of range¹\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eV\u003csub\u003eP-N\u003c\/sub\u003e\u0026gt;250 V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.015%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0225%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0225%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.015%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small\" colspan=\"6\"\u003e\n\u003cspan\u003e¹Range = 1000 V x Irange\u003cbr\u003eReference conditions:\u003c\/span\u003e\n\u003cul class=\"small\"\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb\u003eEnvironmental:\u003c\/b\u003e 23 °C ±5 °C, instrument operating for at least 30 minutes, no external electrical\/magnetic field, RH \u0026lt;65%\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb\u003eInput conditions:\u003c\/b\u003e Cosϕ\/PF=1, Sinusoidal signal f=50 Hz\/60 Hz, power supply 120 V\/230 V ±10%.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb\u003eCurrent and power specifications:\u003c\/b\u003e Input voltage 1 ph: 120 V\/230 V or 3 ph wye\/delta: 230 V\/400 V Input current: I \u0026gt; 10% of Irange\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb\u003ePrimary conductor of clamps or Rogowski coil in center position\u003c\/b\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cb\u003eTemperature coefficient:\u003c\/b\u003e Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cspan\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"width: 528px;\" data-mce-style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 511px;\" colspan=\"2\" data-mce-style=\"width: 511px;\"\u003e\u003cspan\u003eElectrical Specifications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 511px;\" colspan=\"2\" data-mce-style=\"width: 511px;\"\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" rowspan=\"2\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eVoltage range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e100 V to 500 V using safety plug input when powering from the measurement circuit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e100 V to 240 V using standard power cord (IEC 60320 C7)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003ePower consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eMaximum 50 VA (max. 15 VA when powered using IEC 60320 input)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eEfficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e≥ 68.2% (in accordance with energy efficiency regulations)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eMaximum no-load consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e\u0026lt; 0.3 W only when powered using IEC 60320 input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eMains power frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e50\/60 Hz ±15%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eBattery\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eLi-ion 3.7 V, 9.25 Wh, customer-replaceable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eOn-battery runtime\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eFour hours in standard operating mode, up to 5.5 hours in power saving mode\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eCharging time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e\u0026lt; 6 hours\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 511px;\" colspan=\"2\" data-mce-style=\"width: 511px;\"\u003e\u003cspan\u003eData Acquisition\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e16-bit synchronous sampling\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eSampling frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e10.24 kHz at 50\/60 Hz, synchronized to mains frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eInput signal frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e50\/60 Hz (42.5 to 69 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eCircuit types\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye, 3-φ wye IT, 3-φ wye balanced, 3-φ Aron\/Blondel (2-element delta), 3-φ delta open leg, Currents only (load studies)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eData storage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eInternal flash memory (not user replaceable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eMemory size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eTypical 10 logging sessions of 8 weeks with 1-minute intervals and 500 events¹\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 511px;\" class=\"small\" colspan=\"2\" data-mce-style=\"width: 511px;\"\u003e\u003cspan\u003e¹The number of possible logging sessions and logging period depends on user requirements.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 511px;\" colspan=\"2\" data-mce-style=\"width: 511px;\"\u003e\u003cspan\u003eBasic Interval\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eMeasured parameters\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eVoltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eAveraging interval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eUser selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eAveraging time min\/max values\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eVoltage, Current: Full cycle RMS updated every half cycle Aux, Power: 200ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 511px;\" colspan=\"2\" data-mce-style=\"width: 511px;\"\u003e\u003cspan\u003eDemand Interval (Energy Meter Mode)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eMeasured parameters\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eEnergy (Wh, varh, VAh), PF, maximum demand, cost of energy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eInterval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eUser selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 511px;\" colspan=\"2\" data-mce-style=\"width: 511px;\"\u003e\u003cspan\u003eStandards Compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003ePower\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eIEEE 1459\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 511px;\" colspan=\"2\" data-mce-style=\"width: 511px;\"\u003e\u003cspan\u003eInterfaces\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eUSB-A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eFile transfer via USB flash drive, firmware updates\u003cbr\u003eMax. current: 120 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eWiFi\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eFile transfer and remote control via direct connection or WiFi infrastructure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eBluetooth\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eRead auxiliary measurement data from Fluke Connect® 3000 series modules (requires 1734, or 1732 upgrade option)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eUSB-mini\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eData download device to PC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 511px;\" colspan=\"2\" data-mce-style=\"width: 511px;\"\u003e\u003cspan\u003eVoltage Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eNumber of inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e4 (3 phases and neutral)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eMaximum input voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e1000 Vrms, CF 1.7\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eInput impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e10 MΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eBandwidth (-3 dB)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e42.5 Hz - 3.5 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eScaling\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e1:1 and variable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eMeasurement category\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e1000 V CAT III\/600 V CAT IV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 511px;\" colspan=\"2\" data-mce-style=\"width: 511px;\"\u003e\u003cspan\u003eCurrent Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eNumber of inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e3, mode selected automatically for attached sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eInput voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eClamp input: 500 mVrms\/50 mVrms; CF 2.8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eRogowski coil input\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e150 mVrms\/15 mVrms at 50 Hz, 180 mVrms\/18 mVrms at 60 Hz; CF 4; all at nominal probe range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" rowspan=\"4\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e1 A to 150 A\/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e3 A to 300 A\/30 A to 3000 A with thin flexible current probe i17XX-flex3000 24\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e6 A to 600 A\/60 A to 6000 A with thin flexible current probe i17XX-flex6000 36\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e40 mA to 4 A\/0.4 A to 40 A with 40 A clamp i40s-EL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eBandwidth (-3 dB)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e42.5 Hz - 3.5 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eScaling\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e1:1 and variable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 511px;\" colspan=\"2\" data-mce-style=\"width: 511px;\"\u003e\u003cspan\u003eAuxiliary Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eNumber of inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eInput range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e0 to ±10 V dc, 1reading\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eScale factor (available 2014)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eFormat: mx + b (gain and offset) user configurable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eDisplayed units (available 2014)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eUser configurable (7 characters, for example, °C, psi, or m\/s)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 511px;\" colspan=\"2\" data-mce-style=\"width: 511px;\"\u003e\u003cspan\u003eWireless Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eNumber of inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eSupported modules\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eFluke Connect® 3000 series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eAcquisition\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e1 reading\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 511px;\" colspan=\"2\" data-mce-style=\"width: 511px;\"\u003e\u003cspan\u003eEnvironmental Specifications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e-10 °C to +50 °C (14 °F to 122 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eStorage temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e-20 °C to +60 °C (-4 °F to 140 °F), with battery: -20 °C to +50 °C (-4 °F to 122 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" rowspan=\"3\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eOperating humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e10 °C to 30 °C (50 °F to 86 °F) max. 95% RH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e30 °C to 40 °C (86 °F to 104 °F) max. 75% RH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e40 °C to 50 °C (104 °F to 122 °F) max. 45% RH\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eOperating altitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e2000 m (up to 4000 m derate to 1000 V CAT II\/600 V CAT III\/300 V CAT IV)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eStorage altitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e12,000m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eEnclosure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eIP50 in accordance with EN60529\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eVibration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eMIL-T-28800E, Type 3, Class III, Style B\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" rowspan=\"4\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eSafety\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eIEC 61010-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eIEC Mains Input: Overvoltage Category II, Pollution Degree 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eVoltage Terminals: Overvoltage Category IV, Pollution Degree 2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eIEC 61010-2-031: CAT IV 600 V \/ CAT III 1000 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" rowspan=\"3\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eElectromagnetic compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eEN 61326-1: Industrial CISPR 11: Group 1, Class A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eKorea (KCC): Class A Equipment (industrial broadcasting and communication equipment)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eUSA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eTemperature coefficient\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e0.1 x accuracy specification\/°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 511px;\" colspan=\"2\" data-mce-style=\"width: 511px;\"\u003e\u003cspan\u003eGeneral Specifications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eColor LCD display\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003e4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 177px;\" rowspan=\"3\" data-mce-style=\"width: 177px;\"\u003e\u003cspan\u003eWarranty\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eInstrument and power supply: Two-years (battery not included)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eAccessories: one-year\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 334px;\" data-mce-style=\"width: 334px;\"\u003e\u003cspan\u003eCalibration cycle: two-years\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504305123413,"sku":"Fluke 1732\/INTL","price":1386176.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/FLU_1732.jpg?v=1603962456"},{"product_id":"fluke-1736-intl-3-phase-power-logger-international-version","title":"Fluke 1736\/INTL 3-Phase Power Logger, International version","description":"\u003ch2 data-mce-fragment=\"1\"\u003eProduct overview: Fluke 1736 and 1738 Three-Phase Power Quality Loggers\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\" data-mce-fragment=\"1\"\u003e\n\u003cdiv id=\"product-overview\" data-mce-fragment=\"1\"\u003e\n\u003cdiv id=\"overview_content\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Fluke 1736 and 1738 Three-Phase Power Loggers built with Fluke Connect® mobile app and desktop software compatibility give you the data you need to make critical power quality and energy decisions in real-time. The ideal test tools for conducting energy studies and basic power quality logging, the 1736 and 1738 automatically capture and log over 500 power quality parameters so you have more visibility into the data you need to optimize system reliability and savings. With the Fluke 1738 Advanced Power Logger you can perform advanced analysis with an enhanced Power Quality Health Summary (EN50160) function that provides you with fast insight into overall electrical system health. The Power Quality Health Summary is an evaluation of the logged data based on detailed power quality measurements and includes viewable event waveform captures so you have even more visibility into the data you need to optimize system reliability and savings.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAn optimized user interface, flexible current probes, and an intelligent measurement verification function that allows you to reduce measurement errors by digitally verifying and correcting common connection errors makes setup easier than ever and reduces measurement uncertainty. Access and share data remotely with your team via the Fluke Connect® app so you can maintain safer working distances and make critical decisions in real-time, reducing the need for protective equipment, site visits and check-ins. You can also quickly and easily chart and graph measurements to help identify issues and create detailed reports with the included Fluke Energy Analyze Plus software package. Optionally, you can create IEEE519 Reports giving you more insight into harmonic levels, voltage and current distortion, and load current (license required).\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eOther useful features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePresent data locally on the logger, on the Fluke Connect mobile app and desktop software, or through your facility’s Wi-Fi infrastructure\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMeasure all three phases and neutral with four flexible current probes (included)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePower the instrument directly from the measured circuit\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eReview measured values during logging sessions and before downloading for real-time analysis\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIncludes event waveform snapshot and high-resolution RMS profile with the 1738, along with date, timestamp and severity to capture dips, swells, and inrush currents and help pinpoint potential root causes of power quality issues\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e1738 also provides fast insight into overall electrical system health with a Power Quality Health Summary\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eOffers a bright, color touch-screen display for convenient field analysis and data checks\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eHelps you capture the right data every time with a quick, guided, graphical user interface\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eReduces uncertainty about your connections with the intelligent verification function\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAllows you to complete field setups through the front panel or the Fluke Connect App on your smartphone\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eProvides fully integrated logging with other Fluke Connect-enabled devices to simultaneously log up to two additional measurement parameters on a Fluke Connect wireless digital multimeter or module*\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eComes with Energy Analyze Plus application software that enables you to analyze every detail of energy consumption and power quality health and create automated reports\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eLog the most common parameters\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eDesigned to measure the most critical three phase power parameters, the 1736 and 1738 can simultaneously log rms voltage, rms current, voltage and current events, voltage and current THD, voltage and current harmonics up to the 50th harmonic, active power, reactive power, power factor, active energy, reactive energy, and more. With enough memory for more than a year of data logging, the 1736 and 1738 can uncover intermittent or hard-to-find issues that might otherwise have been missed.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAnalysis and Reporting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eCapturing logged data is just one part of the task. Once you have the data, you need to create useful information and reports that can be easily shared and understood by your organization or customers. Fluke Energy Analyze Plus software makes that task as simple as possible. With powerful analysis tools and the ability to create customized reports in minutes you’ll be able to communicate your findings and quickly solve problems so you can optimize system reliability and savings.\u003c\/p\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv aria-expanded=\"true\" data-readmore=\"\" id=\"keyfeature_content\"\u003e\n\u003cp\u003eThe Fluke 1736 and 1738 Three-phase Power Quality Loggers are versatile, three-phase Fluke Connect-compatible power loggers for conducting energy, load and power quality studies.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey measurements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAutomatically capture and log voltage, current, power, harmonics and associated power quality values, and capture dips, swells, and inrush currents with event waveform snapshots and high-resolution RMS profiles\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvenient instrument powering:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePower instrument directly from the measured circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy Analyze Plus application software:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDownload and analyze every detail of energy consumption and power quality state of health with our automated reporting and use the integrated power quality health summary to get an at-a-glance understanding of system health\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 1736 and 1738 Three-Phase Power Quality Loggers\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"6\" style=\"width: 480px;\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\" style=\"width: 480px;\"\u003eAccuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 189px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 109.333px;\"\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 84.6667px;\"\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 97px;\"\u003e\u003cb\u003eIntrinsic Accuracy at Reference Conditions (% of Reading +% of Full Scale)\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 189px;\"\u003eVoltage\u003c\/td\u003e\n\u003ctd style=\"width: 109.333px;\"\u003e1000 V\u003c\/td\u003e\n\u003ctd style=\"width: 84.6667px;\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 97px;\"\u003e±(0.2% + 0.01%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"8\" style=\"width: 74px;\"\u003eCurrent: Direct input\u003c\/td\u003e\n\u003ctd rowspan=\"2\" style=\"width: 115px;\"\u003e\u003cb\u003ei17xx-flex 1500 12\"\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 109.333px;\"\u003e150 A\u003c\/td\u003e\n\u003ctd style=\"width: 84.6667px;\"\u003e0.1 A\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 97px;\"\u003e±(1% + 0.02%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 109.333px;\"\u003e1500 A\u003c\/td\u003e\n\u003ctd style=\"width: 84.6667px;\"\u003e1 A\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 97px;\"\u003e±(1% + 0.02%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 115px;\"\u003ei17xx-flex 3000 24\"\u003c\/td\u003e\n\u003ctd style=\"width: 109.333px;\"\u003e300 A\u003c\/td\u003e\n\u003ctd style=\"width: 84.6667px;\"\u003e1 A\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 97px;\"\u003e±(1% + 0.03%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 109.333px;\"\u003e3000 A\u003c\/td\u003e\n\u003ctd style=\"width: 84.6667px;\"\u003e10 A\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 97px;\"\u003e±(1% + 0.03%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 115px;\"\u003ei17xx-flex 6000 36\"\u003c\/td\u003e\n\u003ctd style=\"width: 109.333px;\"\u003e600 A\u003c\/td\u003e\n\u003ctd style=\"width: 84.6667px;\"\u003e1 A\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 97px;\"\u003e±(1.5% + 0.03%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 109.333px;\"\u003e6000 A\u003c\/td\u003e\n\u003ctd style=\"width: 84.6667px;\"\u003e10 A\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 97px;\"\u003e±(1.5% + 0.03%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 115px;\"\u003ei40s-EL clamp\u003c\/td\u003e\n\u003ctd style=\"width: 109.333px;\"\u003e4 A\u003c\/td\u003e\n\u003ctd style=\"width: 84.6667px;\"\u003e1 mA\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 97px;\"\u003e±(0.7% + 0.02%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 109.333px;\"\u003e40 A\u003c\/td\u003e\n\u003ctd style=\"width: 84.6667px;\"\u003e10 mA\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 97px;\"\u003e±(0.7% + 0.02%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 189px;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"width: 109.333px;\"\u003e42.5 Hz to 69 Hz\u003c\/td\u003e\n\u003ctd style=\"width: 84.6667px;\"\u003e0.01 Hz\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 97px;\"\u003e±(0.1%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 189px;\"\u003eAuxillary input\u003c\/td\u003e\n\u003ctd style=\"width: 109.333px;\"\u003e±10 V dc\u003c\/td\u003e\n\u003ctd style=\"width: 84.6667px;\"\u003e0.1 mV\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 97px;\"\u003e±(0.2% + 0.02%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 189px;\"\u003eVoltage min\/max\u003c\/td\u003e\n\u003ctd style=\"width: 109.333px;\"\u003e1000 V\u003c\/td\u003e\n\u003ctd style=\"width: 84.6667px;\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 97px;\"\u003e±(1% + 0.1%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 189px;\"\u003eCurrent min\/max\u003c\/td\u003e\n\u003ctd style=\"width: 109.333px;\"\u003eDefined by accessory\u003c\/td\u003e\n\u003ctd style=\"width: 84.6667px;\"\u003eDefined by accessory\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 97px;\"\u003e±(5% + 0.2%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 189px;\"\u003eTHD on voltage\u003c\/td\u003e\n\u003ctd style=\"width: 109.333px;\"\u003e1000%\u003c\/td\u003e\n\u003ctd style=\"width: 84.6667px;\"\u003e0.1%\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 97px;\"\u003e±0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 189px;\"\u003eTHD on current\u003c\/td\u003e\n\u003ctd style=\"width: 109.333px;\"\u003e1000%\u003c\/td\u003e\n\u003ctd style=\"width: 84.6667px;\"\u003e0.1%\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 97px;\"\u003e±0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\" style=\"width: 189px;\"\u003eVoltage harmonics 2nd to 50th\u003c\/td\u003e\n\u003ctd rowspan=\"2\" style=\"width: 109.333px;\"\u003e1000 V\u003c\/td\u003e\n\u003ctd rowspan=\"2\" style=\"width: 84.6667px;\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 97px;\"\u003e≥ 10 V: ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold\" style=\"width: 97px;\"\u003e\u0026lt; 10 V: ±0.5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\" style=\"width: 189px;\"\u003eCurrent harmonics 2nd to 50th\u003c\/td\u003e\n\u003ctd rowspan=\"2\" style=\"width: 109.333px;\"\u003eDefined by accessory\u003c\/td\u003e\n\u003ctd rowspan=\"2\" style=\"width: 84.6667px;\"\u003eDefined by accessory\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 97px;\"\u003e≥ 3% of current range: ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"nobold\" style=\"width: 97px;\"\u003e\u0026lt; 3% of current range: ±0.15% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 189px;\"\u003eUnbalance\u003c\/td\u003e\n\u003ctd style=\"width: 109.333px;\"\u003e100%\u003c\/td\u003e\n\u003ctd style=\"width: 84.6667px;\"\u003e0.1%\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 97px;\"\u003e±0.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"6\" style=\"width: 480px;\"\u003eIntrinsic Uncertainty ±(% of reading +% of range)¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 74px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd rowspan=\"2\" style=\"width: 115px;\"\u003e\u003cb\u003eInfluence quantity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 109.333px;\"\u003e\u003cb\u003eiFlex1500-12\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 84.6667px;\"\u003e\u003cb\u003eiFlex3000-24\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20px;\"\u003e\u003cb\u003eiFlex6000-36\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cb\u003ei40S-EL\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 109.333px;\"\u003e\u003cb\u003e150 A \/ 1500 A\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 84.6667px;\"\u003e\u003cb\u003e300 A \/ 3000 A\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 20px;\"\u003e\u003cb\u003e600 A \/ 6000 A\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e\u003cb\u003e4 A \/ 40 A\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 74px;\"\u003eActive Power P\u003c\/td\u003e\n\u003ctd style=\"width: 115px;\"\u003ePF ≥ 0.99\u003c\/td\u003e\n\u003ctd style=\"width: 109.333px;\"\u003e1.2% + 0.005%\u003c\/td\u003e\n\u003ctd style=\"width: 84.6667px;\"\u003e1.2% + 0.0075%\u003c\/td\u003e\n\u003ctd style=\"width: 20px;\"\u003e1.7% + 0.0075%\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e1.2% + 0.005%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 74px;\"\u003eActive Energy E\u003csub\u003ea\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 115px;\"\u003ePF ≥ 0.99\u003c\/td\u003e\n\u003ctd style=\"width: 109.333px;\"\u003e1.2% + 0.005%\u003c\/td\u003e\n\u003ctd style=\"width: 84.6667px;\"\u003e1.2% + 0.0075%\u003c\/td\u003e\n\u003ctd style=\"width: 20px;\"\u003e1.7% + 0.0075%\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e1.2% + 0.005%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 74px;\"\u003eApparent power S\u003c\/td\u003e\n\u003ctd style=\"width: 115px;\"\u003e0 ≤ PF ≤ 1\u003c\/td\u003e\n\u003ctd style=\"width: 109.333px;\"\u003e1.2% + 0.005%\u003c\/td\u003e\n\u003ctd style=\"width: 84.6667px;\"\u003e1.2% + 0.0075%\u003c\/td\u003e\n\u003ctd style=\"width: 20px;\"\u003e1.7% + 0.0075%\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e1.2% + 0.005%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 74px;\"\u003eApparent Energy E\u003csub\u003eap\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 115px;\"\u003e0 ≤ PF ≤ 1\u003c\/td\u003e\n\u003ctd style=\"width: 109.333px;\"\u003e1.2% + 0.005%\u003c\/td\u003e\n\u003ctd style=\"width: 84.6667px;\"\u003e1.2% + 0.0075%\u003c\/td\u003e\n\u003ctd style=\"width: 20px;\"\u003e1.7% + 0.0075%\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e1.2% + 0.005%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 74px;\"\u003eReactive power Q\u003c\/td\u003e\n\u003ctd style=\"width: 115px;\"\u003e0 ≤ PF ≤ 1\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 291px;\"\u003e2.5% of measured apparent power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 74px;\"\u003eReactive Energy E\u003csub\u003er\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 115px;\"\u003e0 ≤ PF ≤ 1\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 291px;\"\u003e2.5% of measured apparent power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 74px;\"\u003ePower Factor PF\u003c\/td\u003e\n\u003ctd style=\"width: 115px;\"\u003e-\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 291px;\"\u003e±0.025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 74px;\"\u003eDisplacement Power Factor\u003c\/td\u003e\n\u003ctd style=\"width: 115px;\"\u003e-\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 291px;\"\u003e±0.025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 74px;\"\u003eDBF\/cosϕ\u003c\/td\u003e\n\u003ctd style=\"width: 115px;\"\u003e-\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"width: 291px;\"\u003e±0.025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 74px;\"\u003eAdditional uncertainty in% of range¹\u003c\/td\u003e\n\u003ctd style=\"width: 115px;\"\u003eV\u003csub\u003eP-N\u003c\/sub\u003e\u0026gt;250 V\u003c\/td\u003e\n\u003ctd style=\"width: 109.333px;\"\u003e0.015%\u003c\/td\u003e\n\u003ctd style=\"width: 84.6667px;\"\u003e0.0225%\u003c\/td\u003e\n\u003ctd style=\"width: 20px;\"\u003e0.0225%\u003c\/td\u003e\n\u003ctd style=\"width: 77px;\"\u003e0.015%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\" class=\"small-font nobold\" style=\"width: 480px;\"\u003e¹Range = 1000 V x Irange\u003cbr\u003eReference conditions:\n\u003cul class=\"small-font\"\u003e\n\u003cli\u003e\n\u003cb\u003eEnvironmental:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e23 °C ±5 °C, instrument operating for at least 30 minutes, no external electrical\/magnetic field, RH \u0026lt;65%\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eInput conditions:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eCosϕ\/PF=1, Sinusoidal signal f=50 Hz\/60 Hz, power supply 120 V\/230 V ±10%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCurrent and power specifications:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eInput voltage 1 ph: 120 V\/230 V or 3 ph wye\/delta: 230 V\/400 V Input current: I \u0026gt; 10% of Irange\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003ePrimary conductor of clamps or Rogowski coil in center position\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTemperature coefficient:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eAdd 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n \n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 510px;\"\u003eElectrical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 510px;\"\u003ePower Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 194px;\"\u003eVoltage range\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e100 V to 500 V using safety plug input when powering from the measurement circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 316px;\"\u003e100 V to 240 V using standard power cord (IEC 60320 C7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eMaximum 50 VA (max. 15 VA when powered using IEC 60320 input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eEfficiency\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e≥ 68.2% (in accordance with energy efficiency regulations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eMaximum no-load consumption\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e\u0026lt; 0.3 W only when powered using IEC 60320 input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eMains power frequency\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e50\/60 Hz ±15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eBattery\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eLi-ion 3.7 V, 9.25 Wh, customer-replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eOn-battery runtime\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eFour hours in standard operating mode, up to 5.5 hours in power saving mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eCharging time\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e\u0026lt; 6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 510px;\"\u003eData Acquisition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e16-bit synchronous sampling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eSampling frequency\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e10.24 kHz at 50\/60 Hz, synchronized to mains frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eInput signal frequency\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e50\/60 Hz (42.5 to 69 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eCircuit types\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye, 3-φ wye IT, 3-φ wye balanced, 3-φ Aron\/Blondel (2-element delta), 3-φ delta open leg, Currents only (load studies)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eData storage\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eInternal flash memory (not user replaceable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eMemory size\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eTypical 10 logging sessions of 8 weeks with 1-minute intervals and 500 events¹\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"small-font nobold\" style=\"width: 510px;\"\u003e¹The number of possible logging sessions and logging period depends on user requirements.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 510px;\"\u003eBasic Interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eMeasured parameters\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eVoltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eAveraging interval\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eUser selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eAveraging time min\/max values\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eVoltage, Current: Full cycle RMS updated every half cycle (URMS1\/2 according to IEC61000-4-30 Aux, Power: 200ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 510px;\"\u003eDemand Interval (Energy Meter Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eMeasured parameters\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eEnergy (Wh, varh, VAh), PF, maximum demand, cost of energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eInterval\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eUser selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 510px;\"\u003ePower Quality Measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eMeasured parameter\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eVoltage, frequency, unbalance, voltage harmonics, THD V, current, harmonics, THD A, TDD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eAveraging interval\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e10 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eIndividual harmonics\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e2nd to 50th harmonic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eTotal harmonic distortion\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eCalculated on 50 harmonics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eEvents\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eVoltage: dips, swells, interruptions, current: inrush current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 194px;\"\u003eTriggered recordings\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eFull cycle RMS updated every half cycle of voltage and current (Urms1\/2 according to IEC61000-4-30)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 316px;\"\u003eWaveform of voltage and current (1738)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 510px;\"\u003eStandards Compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 194px;\"\u003eHarmonics\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eIEC 61000-4-7: Class 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 316px;\"\u003eIEEE 519 (short time harmonics)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003ePower quality\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eIEC 61000-4-30 Class S, IEC62586-1 (PQI-S device)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003ePower\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eIEEE 1459\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003ePower quality compliance\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eEN50160 (for measured parameters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 510px;\"\u003eInterfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eUSB-A\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eFile transfer via USB flash drive, firmware updates\u003cbr\u003eMax. current: 120 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eWiFi\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eFile transfer and remote control via direct connection or WiFi infrastructure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eBluetooth\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eRead auxiliary measurement data from Fluke Connect® 3000 series modules (requires 1738 or 1736 upgrade option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eUSB-mini\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eData download device to PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 510px;\"\u003eVoltage Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eNumber of inputs\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e4 (3 phases and neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eMaximum input voltage\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e1000 Vrms, CF 1.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eInput impedance\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e10 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eBandwidth (-3 dB)\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e42.5 Hz - 3.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eScaling\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e1:1 and variable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eMeasurement category\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e1000 V CAT III\/600 V CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 510px;\"\u003eCurrent Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eNumber of inputs\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e4, mode selected automatically for attached sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eInput voltage\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eClamp input: 500 mVrms\/50 mVrms; CF 2.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eRogowski coil input\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e150 mVrms\/15 mVrms at 50 Hz, 180 mVrms\/18 mVrms at 60 Hz; CF 4; all at nominal probe range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 194px;\"\u003eRange\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e1 A to 150 A\/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 316px;\"\u003e3 A to 300 A\/30 A to 3000 A with thin flexible current probe i17XX-flex3000 24\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 316px;\"\u003e6 A to 600 A\/60 A to 6000 A with thin flexible current probe i17XX-flex6000 36\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 316px;\"\u003e40 mA to 4 A\/0.4 A to 40 A with 40 A clamp i40s-EL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eBandwidth (-3 dB)\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e42.5 Hz - 3.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eScaling\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e1:1 and variable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 510px;\"\u003eAuxiliary Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eNumber of inputs\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eInput range\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e0 to ±10 V dc, 1reading\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eScale factor\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eFormat: mx + b (gain and offset) user configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eDisplayed units\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eUser configurable (7 characters, for example, °C, psi, or m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 510px;\"\u003eWireless Connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eNumber of inputs\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eSupported modules\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eFluke Connect® 3000 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eAcquisition\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e1 reading\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 510px;\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e-10 °C to +50 °C (14 °F to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e-20 °C to +60 °C (-4 °F to 140 °F), with battery: -20 °C to +50 °C (-4 °F to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 194px;\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e10 °C to 30 °C (50 °F to 86 °F) max. 95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 316px;\"\u003e30 °C to 40 °C (86 °F to 104 °F) max. 75% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 316px;\"\u003e40 °C to 50 °C (104 °F to 122 °F) max. 45% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e2000 m (up to 4000 m derate to 1000 V CAT II\/600 V CAT III\/300 V CAT IV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eStorage altitude\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e12,000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eIP50 in accordance with EN60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eVibration\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eMIL-T-28800E, Type 3, Class III, Style B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 194px;\"\u003eSafety\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eIEC 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 316px;\"\u003eIEC Mains Input: Overvoltage Category II, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 316px;\"\u003eVoltage Terminals: Overvoltage Category IV, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 316px;\"\u003eIEC 61010-2-031: CAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 194px;\"\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eEN 61326-1: Industrial CISPR 11: Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 316px;\"\u003eKorea (KCC): Class A Equipment (industrial broadcasting and communication equipment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 316px;\"\u003eUSA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e0.1 x accuracy specification\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 510px;\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eColor LCD display\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 194px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eInstrument and power supply: Two-years (battery not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 316px;\"\u003eAccessories: one-year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 316px;\"\u003eCalibration cycle: two-years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 194px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eInstrument: 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 316px;\"\u003ePower supply: 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 316px;\"\u003eInstrument with power supply attached: 19.8 cm x 16.7 cm x 9 cm (7.8 in x 6.6 in x 3.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 194px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eInstrument: 1.1 kg (2.5 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" style=\"width: 316px;\"\u003ePower supply: 400 g (0.9 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eTamper protection\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eKensington lock slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 510px;\"\u003ei17xx-flex 1500 12\" Flexible Current Probe Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e1 to 150 A ac\/10 to 1500 A ac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eNondestructive current\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e100 kA (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eIntrinsic error at reference condition*\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e±0.7% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eAccuracy 173x + iFlex\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e±(1% of reading + 0.02% of range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eTemperature coefficient over operating temperature range\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e0.05% of reading\/°C 0.09% of reading\/°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eWorking voltage\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e1000 V CAT III, 600 V CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eProbe cable length\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e305 mm (12 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eProbe cable diameter\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e7.5 mm (0.3 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eMinimum bending radius\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e38 mm (1.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eOutput cable length\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e2 m (6.6 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e115 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eProbe cable material\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eTPR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eCoupling material\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003ePOM + ABS\/PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eOutput cable\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eTPR\/PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e-20 °C to +70 °C (-4 °F to 158 °F) temperature of conductor under test shall not exceed 80 °C (176 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eTemperature, non-operating\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e-40 °C to +80 °C (-40 °F to 176 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eRelative humidity, operating\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003e15% to 85% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eIP rating\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eIEC 60529:IP50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 194px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"width: 316px;\"\u003eOne-year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"small-font nobold\" style=\"width: 510px;\"\u003e* Reference condition:\n\u003cul class=\"small-font\"\u003e\n\u003cli\u003eEnvironmental: 23 °C ±5 °C, no external electrical\/magnetic field, RH 65%\u003c\/li\u003e\n\u003cli\u003ePrimary conductor in center position\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504305320021,"sku":"Fluke 1736\/INTL","price":2346432.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/Fluke1736EUS_Main1.jpg?v=1602247789"},{"product_id":"fluke-1738-intl-3-phase-power-logger-international-advanced-version","title":"Fluke 1738\/INTL 3-Phase Power Logger, international advanced version","description":"\u003cp\u003eFLUKE-1738\/INTL  FLUKE-1738\/INTL, POWER LOGGER, INTERNATIONAL ADVANCED VERSION\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504305385557,"sku":"Fluke 1738\/INTL","price":2537612.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/fluke-1738-1-new-1500x1000.jpg?v=1627048531"},{"product_id":"fluke-1742-15-intl-power-quality-logger-with-60cm-1500a-iflex-intl-version","title":"Fluke 1742\/15\/INTL Power Quality Logger with 60 cm 1,500A iFLex, INTL version","description":"\u003ch2\u003eProduct overview: Fluke 1742, 1746 and 1748 Three-Phase Power Quality Loggers\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003eThe Fluke 1742, 1746 and 1748 Three-Phase Power Quality Loggers give you fast, easy access to the data you need to make critical power quality and energy decisions in real-time. With the included\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.fluke.com\/en\/support\/software-downloads\/fluke-energy-analyze-plus\"\u003eEnergy Analyze Plus\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003esoftware package you can easily create detailed reports.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUpgrade according to future needs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1748 logs over 500 different parameters for each averaging period. This allows you to analyze power quality in detail and to correlate intermittent events with detailed waveform data, helping to identify the root cause of disturbances. For basic power quality logging, the Fluke 1746 captures all relevant power parameters for performing energy saving studies and electrical network planning with a full upgrade option to 1748 available. For simple load and energy studies the Fluke 1742 offers optimal performance in a rugged package and can be upgraded to 1746, or complete 1748, functionality.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNational and international standards\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompact and rugged, the Fluke 1740 Series Three-Phase Power Quality Loggers are designed specifically for technicians and engineers who need the flexibility to troubleshoot, quantify energy usage and analyze power distribution systems. Fully compliant with international power quality standards such as IEC 61000-4-30 Class A and capable of simultaneously logging up to 500 parameters while also capturing events, the Fluke 1740 Series helps uncover intermittent and hard-to-find power quality issues more easily than ever.\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.fluke.com\/en\/support\/software-downloads\/fluke-energy-analyze-plus\"\u003eEnergy Analyze Plus\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003esoftware quickly assesses the quality of power at the service entrance, substation, or at the load, according to national and international standards including EN 50160 and IEEE 519.\u003c\/p\u003e\n\u003cp\u003eAn optimized user interface, flexible current probes, and an intelligent measurement verification function that allows you to digitally verify and correct connections makes setup easier than ever and reduces measurement uncertainty. Minimize your time in potentially hazardous environments and reduce the hassle of suiting up in PPE by using a wireless connection (Wi-Fi) to view data directly in the field.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnalysis and reporting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCapturing logged data is just one part of the task. Once you have the data, you need to create useful information and reports that can be easily shared and understood by your organization or customers. Fluke\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.fluke.com\/en\/support\/software-downloads\/fluke-energy-analyze-plus\"\u003eEnergy Analyze Plus\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003esoftware makes that task as simple as possible. With powerful analysis tools and the ability to create customized reports in minutes you’ll be able to communicate your findings and quickly solve problems so you can optimize system reliability and savings. A range of built-in report templates for industry standards such as EN 50160, IEEE 519 and GOST enable one-click reporting so you can create high quality reports at the touch of a button. Reports can be modified as standards evolve, or new versions become available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich power logger is right for you?\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003e1742\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003e1746\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003e1748\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage, current, power, power factor, frequency\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy forward\/reverse\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Demand\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlicker\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage and current harmonics (to 50th)\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnbalance\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRapid voltage change events\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterharmonics (to 50th)\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDips, swells, interruption and transient events tables\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush current\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransients (low frequency) \/ Waveform deviation events\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" align=\"left\"\u003e\u003cstrong\u003eRecording\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrend\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform snapshots\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRMS profile\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\" align=\"left\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB (mini B)\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWi-Fi download Instrument to device\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWi-Fi download via Wi-Fi hub (free with registration)\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eOpt.\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eOpt.\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eOpt.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eIncluded accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible current probe\u003c\/td\u003e\n\u003ctd align=\"center\"\u003enot \/B version\u003c\/td\u003e\n\u003ctd align=\"center\"\u003enot \/B version\u003c\/td\u003e\n\u003ctd align=\"center\"\u003enot \/B version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB stick\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB cable\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3PHVL-17XX cable assembly\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLUKE-17XX-TL 0.18M test lead set\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLUKE-17XX-TL 2M test lead set\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlligator clips\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e4\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e4\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e173x\/174x Soft Case\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable marker kit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMP1-3R\/1B-Magnet Probe 1 set (3 red, 1 black)\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eOpt.\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e1\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e174x-Hanger Kit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eOpt.\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eOpt.\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\"In-workshop\" or \"in-the-field\" setup and download through PC application software:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esimple download using USB memory stick, Wi-Fi download, wired Ethernet connection or via USB cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.fluke.com\/en\/support\/software-downloads\/fluke-energy-analyze-plus\"\u003eEnergy Analyze Plus\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eapplication software:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDownload and analyze every measured detail of energy consumption and power quality state-of-health with automated reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne-touch reporting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCreate standardized reports according to commonly used standards like EN 50160, IEEE 519, GOST 33073 or export data in PQDIF or NeQual compatible format for use with third party software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced analysis:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eChoose any available logged parameter to create a highly customized view of logged measurements for advanced correlation of data.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasure all three voltage and current phases plus the neutral current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThree-phase and neutral voltage leads and four flexible current probes or optional current clamps for CT secondary current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive logging:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMore than 20 separate logging sessions can be stored in the instrument. A comprehensive range of power and power quality variables are automatically logged so you never lose measurement trends.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasure with premium accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMeets the rigorous IEC 61000-4-30 Class A Edition 3 standard for ‘Testing and measurement techniques–Power quality measurement methods.'\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapture dips, swells and interruptions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1748 includes event waveform capture and RMS event profile, along with date, timestamp and severity information to help pinpoint potential root causes of power quality issues.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasure key power quality parameters:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMeasures harmonics and interharmonics for voltage and current, also includes unbalance, flicker and rapid voltage changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized user interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCapture the right data every time with quick, guided, graphical PC based application setup and reduce uncertainty about your connections with an intelligent verification feature and the only auto-correction function for a power quality logger. Connection errors are automatically indicated via an amber light on the unit’s power button, this light turns green once corrected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized user interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eQuick, guided, graphical setup ensures you’re capturing the right data every time, and the intelligent verification function indicates correct connections have been made, reducing user uncertainty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible power supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePowers directly from the measured circuit with the widest available range for a power quality logger automatically going from 100 V to 500 V or from a wall line cord, so you can test anywhere.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged and reliable:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned to withstand harsh installation environments with IP65 rating when used with IP65 voltage input adapter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo external USB ports:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOne for PC connection and another for quick, simple data download to standard USB thumb drives, allowing you to leave the measurement device in place and download without disrupting logging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWired and wireless connections for instrument setup and high-speed data download.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned to fit in tight spaces and panels with small 23 cm x 18 cm x 5.4 cm (9.1 in x 7.1 in x 2.1 in) footprint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighest safety rating in the industry:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e600 V CAT IV\/1000 V CAT III rated for use at the service entrance and downstream.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized measurement accessories:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnique tangle-free flat voltage cable and thin flexible current probes ensure easy installation even in tight spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery life:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFour-hour operating time (backup time) per charge on lithium-ion battery to withstand temporary power disruptions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecurity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSafeguard your best asset from theft with a standard chain or other security device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnetic hanger kit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConveniently stow the instrument safely inside or outside of electrical panels; compatible with all models and included with 1748 model as standard.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 1742, 1746 and 1748 Three-Phase Power Quality Loggers\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\" class=\"v-top\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\" class=\"v-top\"\u003eAccuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eParameter\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e\u003cstrong\u003eMaximum Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e\u003cstrong\u003eIntrinsic Accuracy at Reference Conditions (% of Reading +% of Range)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eVoltage\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1000 V\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e±0.1 % of nominal voltage \u003csup\u003e1, 2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"8\" class=\"v-top\"\u003eCurrent: Direct input\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003ei17xx-flex 1500IP 24 1500 A\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e150 A\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.01 A (min. 1.5A)\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\" class=\"v-top\"\u003e±(1% + 0.02%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003e1500 A\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003ei17xx-flex 3000IP 24 3000 A\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e300 A\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.01 A (min. 3.0 A)\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\" class=\"v-top\"\u003e±(1% + 0.03%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003e3000 A\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003ei17xx-flex 6000IP 36 6000 A\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e600 A\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.01 A (min. 6.0 A)\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\" class=\"v-top\"\u003e±(1.5% + 0.03%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003e6000 A\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003ei40s-EL clamp\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e4 A\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1 mA\u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\" class=\"v-top\"\u003e±(0.7% + 0.02%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003e40 A\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eFrequency\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e42.5 Hz to 69 Hz\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.01 Hz\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e±(0.1%)\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eAuxiliary input\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e±10 V dc\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.1 mV\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e±(0.2% + 0.02%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eVoltage min\/max\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1000 V\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e±0.2 % of nominal input voltage\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eCurrent min\/max\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eDefined by accessory\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eDefined by accessory\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e±(5% + 0.2%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eTHD on voltage\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1000%\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.10%\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e± 2.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eTHD on current\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1000%\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.10%\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e± 2.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\" class=\"v-top\"\u003eVoltage harmonics 2nd to 50th\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e1000 V\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e≥ 1 V: ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e\u0026lt; 1 V: ±0.05V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\" class=\"v-top\"\u003eCurrent harmonics 2nd to 50th\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003eDefined by accessory\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003eDefined by accessory\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e≥ 3% of current range: ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e\u0026lt; 3% of current range: ±0.15% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eFlicker P\u003csub\u003eLT\u003c\/sub\u003e, P\u003csub\u003eST\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0 to 20\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.01\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\" class=\"v-top\"\u003eCurrent probe accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e\u003cstrong\u003eInfluence quantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e\u003cstrong\u003eiFlex1500IP-24\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e\u003cstrong\u003eiFlex3000IP-24 \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e\u003cstrong\u003eiFlex6000IP-36\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e\u003cstrong\u003ei40S-EL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003e\u003cstrong\u003e150 A \/ 1500 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e\u003cstrong\u003e300 A \/ 3000 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e\u003cstrong\u003e600 A \/ 6000 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e\u003cstrong\u003e4 A \/ 40 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eActive Power P \u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003ePF ≥ 0.99\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e1.2% + 0.005%\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e1.2% + 0.0075%\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e1.7% + 0.0075%\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e1.2% + 0.005%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eActive Energy E\u003csub\u003ea\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eApparent power S\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e0 ≤ PF ≤ 1\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e1.2% + 0.005%\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e1.2% + 0.0075%\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e1.7% + 0.0075%\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e1.2% + 0.005%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eApparent Energy E\u003csub\u003eap\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eReactive power Q\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003e0 ≤ PF ≤ 1\u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"4\" class=\"v-top\"\u003e2.5% of measured apparent power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eReactive Energy E\u003csub\u003er\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003ePower Factor PF\u003c\/td\u003e\n\u003ctd rowspan=\"3\" class=\"v-top\"\u003e-\u003c\/td\u003e\n\u003ctd rowspan=\"3\" colspan=\"4\" class=\"v-top\"\u003e±0.025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eDisplacement Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eFactor DPF\/cosΦ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eAdditional uncertainty in% of range\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eV\u003csub\u003eP-N\u003c\/sub\u003e\u0026gt;250 V\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.015%\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.023%\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.023%\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.015%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\" class=\"v-top\"\u003e\n\u003csmall\u003e\u003csup\u003e1\u003c\/sup\u003e\u003c\/small\u003e\u003csmall\u003e In the range of 100 V … 500 V; also known as Udin\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e 0 °C … 45 °C: Intrinsic accuracy x 2, outside of 0 °C … 45 °C: Intrinsic accuracy x 3\u003cbr\u003e\u003csup\u003e3\u003c\/sup\u003e Consult operators manual for details\u003cbr\u003e\u003cbr\u003eReference conditions:\u003cbr\u003eEnvironmental: 23 °C ± 5 °C, instrument operating for at least 30 minutes, no external electrical\/magnetic field, RH \u0026lt;65 %\u003cbr\u003eInput conditions: Cosφ\/PF=1, Sinusoidal signal f=50 Hz\/60 Hz, power supply 120 V\/230 V ±10 %.\u003cbr\u003eCurrent and power specifications: Input voltage 1 ph: 120 V\/230 V or 3 ph wye\/delta: 230 V\/400 V\u003cbr\u003eInput current: I \u0026gt; 10 % of I range\u003cbr\u003ePrimary conductor of clamps or Rogowski coil in center position\u003cbr\u003eTemperature coefficient: Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eElectrical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003ePower Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003eVoltage range\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e100 V to 500 V using safety plug input when powering from the measurement circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003e100 V to 240 V MA-C8 and using standard power cord (IEC 60320 C7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eMaximum 50 VA (max. 15 VA when powered using MA-C8 adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eEfficiency\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e≥ 68.2% (in accordance with energy efficiency regulations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMaximum no-load consumption\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e\u0026lt; 0.3 W only when powered using IEC 60320 input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMains power frequency\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e50\/60 Hz ±15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eBattery\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eLi-ion 3.7 V, 9.25 Wh, customer-replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eOn-battery runtime\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eTypically 4 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eCharging time\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e\u0026lt; 6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eData Acquisition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eResolution\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e16-bit synchronous sampling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eSampling frequency\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e10.24 kHz at 50\/60 Hz, synchronized to mains frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eInput signal frequency\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e50\/60 Hz (42.5 to 69 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eCircuit types\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1-Φ, 1-Φ IT, split phase, 3-Φ delta, 3-Φ wye, 3-Φwye IT, 3-Φ wye balanced, 3-Φ Aron\/Blondel (2-element delta), 3-Φ delta open leg, currents only (load studies)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eData storage\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eInternal flash memory (not user replaceable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMemory size\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eTypical 20 logging sessions of 4 weeks with 1-minute intervals and 500 events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eBasic Interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMeasured parameters\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eVoltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eAveraging interval\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eUser selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eAveraging time min\/max values\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eVoltage, Current: Full cycle RMS updated every half cycle (URMS1\/2 according to IEC61000-4-30 Aux, Power: 200ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eDemand Interval (Energy Meter Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMeasured parameters\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eEnergy (Wh, varh, VAh), PF, maximum demand, cost of energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eInterval\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eUser selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003ePower Quality Measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMeasured parameter\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eVoltage, frequency, unbalance, voltage harmonics, THD V, current, harmonics, THD A, TDD, voltage interharmonics, TID V, current interharmonics, TID A, Flicker, Mains Signaling, under\/over deviation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eAveraging interval\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e10 min for all parameters\u003cbr\u003e2 hrs (long term Flicker PLT)\u003cbr\u003e150\/180 cycles (3 s) for harmonics (requires software license IEEE519\/REPORT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eIndividual harmonics\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e2nd to 50th harmonic\u003cbr\u003eGrouping according to IEC 61000-4-7 user configurable depending on application: Sub-grouped (harmonics + interharmonics), grouped or harmonic bins only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eInterharmonics\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1st to the 50th interharmonic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eTotal harmonic distortion\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eCalculated on 50 voltage harmonics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eEvents\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eVoltage: dips, swells, interruptions, current: inrush current\u003cbr\u003e1748: mains signaling, transients (low frequency)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" class=\"v-top\"\u003eTriggered recordings\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eRMS profile: Full cycle RMS updated every half cycle of voltage and current up to 11 s (URMS1\/2 according to IEC 61000-4-30)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eWaveform of voltage and current up to 200 ms, 10\/12 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMains signaling: 10\/12 cycle RMS recording of the configured frequencies up to 120s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eInrush\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eRMS profile based on 1\/2 cycle RMS steady state triggering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eFlicker\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eIn accordance with IEC 61000-4-15 and IEEE 1453\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMains signaling\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eTwo user defined frequencies up to 3 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003ePQ Health\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eSummarizes power quality measurements in one table. Detailed data available for each parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eEN 50160\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eCompliance with standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eProgrammable PQ limits\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eEnables user defined limits for local standards compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eStandards Compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003eHarmonics\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eIEC 61000-4-7: Class 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eIEEE 519 (short time and very short time harmonics)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003ePower quality\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eIEC 61000-4-30 Class A, IEC 62586-1, IEC 62586-2 (PQI-A-PI device)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003ePower\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eIEEE 1459\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003ePower quality compliance\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eEN 50160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" class=\"v-top\"\u003eSafety\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eGeneral: IEC 61010-1: Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMeasurement: IEC 61010-2-033: CAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003ePower Supply: Overvoltage Category IV, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eLi-ion Battery: IEC 62133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eInterfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eUSB-A\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eFile transfer via USB flash drive, firmware updates, max. supply current: 120 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eWi-Fi (free with product registration)\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eFile transfer and remote control via direct connection or Wi-Fi infrastructure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eBluetooth\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eRead auxiliary measurement data from Fluke Connect® 3000 series modules (requires supported USB to BLE or Wi-Fi\/BLE adapter, check for availability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eUSB-mini\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eData download device to PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eVoltage Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eNumber of inputs\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e4 (3 phases referenced to neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMaximum input voltage\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1000 Vrms, CF 1.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eInput impedance\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e10 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eBandwidth\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e42.5 Hz to 3.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eScaling\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1:1 and variable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMeasurement category\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1000 V CAT III\/600 V CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003eCurrent Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eNumber of inputs\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e4 (3 phases and neutral), mode selected automatically for attached sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003eInput voltage\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eClamp input: 500 mVrms\/50 mVrms; CF 2.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eRogowski coil input: 150 mVrms\/15 mVrms at 50 Hz, 180 mVrms\/18 mVrms at 60 Hz; CF 4 all at nominal probe range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" class=\"v-top\"\u003eRange\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1 A to 150 A\/10 A to 1500 A with thin flexible current probe i17XX-flex1500 IP 24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003e3 A to 300 A\/30 A to 3000 A with thin flexible current probe i17XX-flex3000 IP 24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003e6 A to 600 A\/60 A to 6000 A with thin flexible current probe i17XX-flex6000 IP 36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003e40 mA to 4 A\/0.4 A to 40 A with 40 A clamp i40s-EL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eBandwidth\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e42.5 Hz - 3.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eScaling\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1:1 and variable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAuxiliary Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eNumber of inputs\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e2 (Analog with auxiliary adapter, or up to 2 BLE devices simultaneously)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eInput range\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0 to ± 10 V dc, or 0 to ± 1000 V dc (with optional adapter), 1 reading\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eScale factor\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eFormat: mx + b (gain and offset) user configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eDisplayed units\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eUser configurable (7 characters, for example, °C, psi, or m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWireless Bluetooth connection (check for availability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eNumber of inputs\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eSupported modules\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eFluke Connect® 3000 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eAcquisition\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1 reading\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e-25 °C to +50 °C (-13 °F to 122 °F)\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eWithout battery: -25 °C to +60 °C (-13 °F to 140 °F), with battery: -20 °C to +50 °C (−4 °F to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" class=\"v-top\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eIEC 60721-3-3: 3K6:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003e-25 °C to +30 °C (-13 °F to +86 °F): ≤ 100 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003e40 °C (104 °F): 55 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003e50 °C (122 °F): 35 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eOperating altitude\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e2000 m (up to 4000 m derate to 1000 V CAT II\/600 V CAT III\/300 V CAT IV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eStorage altitude\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" class=\"v-top\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eIEC 60529: IP50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eIEC 60529: IP65 with IP65 rated voltage connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eVibration\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eIEC 60721-3-3 \/ 3M2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" class=\"v-top\"\u003eElectromagnetic compatibility (EMC)\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eEN 61326-1: Industrial CISPR 11: Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eIEC 61000-6-5 Power station environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eKorea (KCC): Class A Equipment (industrial broadcasting and communication equipment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eUSA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" class=\"v-top\"\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eTwo-years (battery not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories: one-year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration cycle: two-years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e23.0 cm x 18.0 cm x 5.4 cm (9.1 in x 7.1 in x 2.1 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eInstrument: 1 kg (2.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eTamper protection\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eAccept securing cables (max. Φ 6mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" class=\"v-top\"\u003e\n\u003csup\u003e1\u003c\/sup\u003eWarm up the product to -10 °C (+14 °F) before you power the unit on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ei17XX-FLEX1.5KIP Flexible Current Probe Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1 to 150 A ac\/10 to 1500 A ac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eProbe cable length\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e610 mm (24 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eProbe cable diameter\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e7.5 mm (0.3 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e170 g (0.38 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eMinimum bending radius\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e38 mm (1.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eNondestructive current\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e100 kA (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eTemperature coefficient over\u003cbr\u003eoperating temperature range\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e0.05 % of reading\/°C (0.028 % of reading\/°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eWorking voltage\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e1000 V CAT III, 600 V CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eOutput cable length\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e2.0 m (6.5 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eProbe cable material\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003eTPR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"v-top\"\u003e115 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504305516629,"sku":"Fluke 1742\/15\/INTL","price":2101044.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/FLUKE-1742-15-INTL-POWER-QUALITY-LOGGER-W60CM-1500A-IFLEX-INTL.jpg?v=1612946203"},{"product_id":"fluke-1742-6-upgrade-1742-to-1746-upgrade","title":"Fluke  1742-6\/Upgrade 1742 to 1746 Upgrade","description":"\u003cp\u003e1742-6\/UPGRADE  1742-6\/UPGRADE,1742 TO 1746 UPGRADE\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504305614933,"sku":"Fluke 1742-6\/Upgrade","price":1024628.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/3_bfcb0ea1-8db1-41a0-8a82-39a2b9b3685f.jpg?v=1593521573"},{"product_id":"fluke-1746-15-intl-power-quality-logger-with-60cm-1500a-iflex-intl-version","title":"Fluke 1746\/15\/INTL Power Quality Logger with 60 cm 1,500A iFlex, INTL version","description":"\u003ch2\u003eProduct overview: Fluke 1742, 1746 and 1748 Three-Phase Power Quality Loggers\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003eThe Fluke 1742, 1746 and 1748 Three-Phase Power Quality Loggers give you fast, easy access to the data you need to make critical power quality and energy decisions in real-time. With the included\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.fluke.com\/en\/support\/software-downloads\/fluke-energy-analyze-plus\"\u003eEnergy Analyze Plus\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003esoftware package you can easily create detailed reports.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUpgrade according to future needs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1748 logs over 500 different parameters for each averaging period. This allows you to analyze power quality in detail and to correlate intermittent events with detailed waveform data, helping to identify the root cause of disturbances. For basic power quality logging, the Fluke 1746 captures all relevant power parameters for performing energy saving studies and electrical network planning with a full upgrade option to 1748 available. For simple load and energy studies the Fluke 1742 offers optimal performance in a rugged package and can be upgraded to 1746, or complete 1748, functionality.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNational and international standards\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompact and rugged, the Fluke 1740 Series Three-Phase Power Quality Loggers are designed specifically for technicians and engineers who need the flexibility to troubleshoot, quantify energy usage and analyze power distribution systems. Fully compliant with international power quality standards such as IEC 61000-4-30 Class A and capable of simultaneously logging up to 500 parameters while also capturing events, the Fluke 1740 Series helps uncover intermittent and hard-to-find power quality issues more easily than ever.\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.fluke.com\/en\/support\/software-downloads\/fluke-energy-analyze-plus\"\u003eEnergy Analyze Plus\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003esoftware quickly assesses the quality of power at the service entrance, substation, or at the load, according to national and international standards including EN 50160 and IEEE 519.\u003c\/p\u003e\n\u003cp\u003eAn optimized user interface, flexible current probes, and an intelligent measurement verification function that allows you to digitally verify and correct connections makes setup easier than ever and reduces measurement uncertainty. Minimize your time in potentially hazardous environments and reduce the hassle of suiting up in PPE by using a wireless connection (Wi-Fi) to view data directly in the field.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnalysis and reporting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCapturing logged data is just one part of the task. Once you have the data, you need to create useful information and reports that can be easily shared and understood by your organization or customers. Fluke\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.fluke.com\/en\/support\/software-downloads\/fluke-energy-analyze-plus\"\u003eEnergy Analyze Plus\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003esoftware makes that task as simple as possible. With powerful analysis tools and the ability to create customized reports in minutes you’ll be able to communicate your findings and quickly solve problems so you can optimize system reliability and savings. A range of built-in report templates for industry standards such as EN 50160, IEEE 519 and GOST enable one-click reporting so you can create high quality reports at the touch of a button. Reports can be modified as standards evolve, or new versions become available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich power logger is right for you?\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003e1742\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003e1746\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003e1748\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage, current, power, power factor, frequency\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy forward\/reverse\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Demand\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlicker\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage and current harmonics (to 50th)\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnbalance\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRapid voltage change events\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterharmonics (to 50th)\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDips, swells, interruption and transient events tables\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush current\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransients (low frequency) \/ Waveform deviation events\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" colspan=\"4\"\u003e\u003cstrong\u003eRecording\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrend\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWaveform snapshots\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRMS profile\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e \u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\" colspan=\"4\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB (mini B)\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWi-Fi download Instrument to device\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWi-Fi download via Wi-Fi hub (free with registration)\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eOpt.\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eOpt.\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eOpt.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eIncluded accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible current probe\u003c\/td\u003e\n\u003ctd align=\"center\"\u003enot \/B version\u003c\/td\u003e\n\u003ctd align=\"center\"\u003enot \/B version\u003c\/td\u003e\n\u003ctd align=\"center\"\u003enot \/B version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB stick\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB cable\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3PHVL-17XX cable assembly\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLUKE-17XX-TL 0.18M test lead set\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLUKE-17XX-TL 2M test lead set\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlligator clips\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e4\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e4\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e173x\/174x Soft Case\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable marker kit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMP1-3R\/1B-Magnet Probe 1 set (3 red, 1 black)\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eOpt.\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e1\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e174x-Hanger Kit\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eOpt.\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eOpt.\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e•\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\"In-workshop\" or \"in-the-field\" setup and download through PC application software:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esimple download using USB memory stick, Wi-Fi download, wired Ethernet connection or via USB cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.fluke.com\/en\/support\/software-downloads\/fluke-energy-analyze-plus\"\u003eEnergy Analyze Plus\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003eapplication software:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDownload and analyze every measured detail of energy consumption and power quality state-of-health with automated reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne-touch reporting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCreate standardized reports according to commonly used standards like EN 50160, IEEE 519, GOST 33073 or export data in PQDIF or NeQual compatible format for use with third party software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced analysis:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eChoose any available logged parameter to create a highly customized view of logged measurements for advanced correlation of data.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasure all three voltage and current phases plus the neutral current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThree-phase and neutral voltage leads and four flexible current probes or optional current clamps for CT secondary current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive logging:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMore than 20 separate logging sessions can be stored in the instrument. A comprehensive range of power and power quality variables are automatically logged so you never lose measurement trends.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasure with premium accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMeets the rigorous IEC 61000-4-30 Class A Edition 3 standard for ‘Testing and measurement techniques–Power quality measurement methods.'\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapture dips, swells and interruptions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1748 includes event waveform capture and RMS event profile, along with date, timestamp and severity information to help pinpoint potential root causes of power quality issues.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasure key power quality parameters:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMeasures harmonics and interharmonics for voltage and current, also includes unbalance, flicker and rapid voltage changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized user interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCapture the right data every time with quick, guided, graphical PC based application setup and reduce uncertainty about your connections with an intelligent verification feature and the only auto-correction function for a power quality logger. Connection errors are automatically indicated via an amber light on the unit’s power button, this light turns green once corrected.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized user interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eQuick, guided, graphical setup ensures you’re capturing the right data every time, and the intelligent verification function indicates correct connections have been made, reducing user uncertainty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible power supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePowers directly from the measured circuit with the widest available range for a power quality logger automatically going from 100 V to 500 V or from a wall line cord, so you can test anywhere.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged and reliable:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned to withstand harsh installation environments with IP65 rating when used with IP65 voltage input adapter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo external USB ports:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOne for PC connection and another for quick, simple data download to standard USB thumb drives, allowing you to leave the measurement device in place and download without disrupting logging.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWired and wireless connections for instrument setup and high-speed data download.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned to fit in tight spaces and panels with small 23 cm x 18 cm x 5.4 cm (9.1 in x 7.1 in x 2.1 in) footprint.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighest safety rating in the industry:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e600 V CAT IV\/1000 V CAT III rated for use at the service entrance and downstream.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptimized measurement accessories:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnique tangle-free flat voltage cable and thin flexible current probes ensure easy installation even in tight spaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery life:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFour-hour operating time (backup time) per charge on lithium-ion battery to withstand temporary power disruptions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecurity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSafeguard your best asset from theft with a standard chain or other security device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMagnetic hanger kit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConveniently stow the instrument safely inside or outside of electrical panels; compatible with all models and included with 1748 model as standard.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cp\u003eThe Fluke 1742, 1746 and 1748 Three-Phase Power Quality Loggers are the best tools to troubleshoot, quantify energy usage and analyze power distribution systems in a fast, easy and safe way.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasure key power quality parameters:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMeasures harmonics and interharmonics for voltage and current, also includes unbalance, flicker and rapid voltage changes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasure with premium accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMeets the rigorous IEC 61000-4-30 Class A Edition 3 standard for ‘Testing and measurement techniques–Power quality measurement methods.'\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne-touch reporting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCreate standardized reports according to commonly used standards like EN 50160, IEEE 519, GOST 33073 or export data in PQDIF or NeQual compatible format for use with third party software using the included Fluke Energy Analyze Plus Software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 1742, 1746 and 1748 Three-Phase Power Quality Loggers\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003ctable style=\"width: 534px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"6\" style=\"width: 498px;\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"6\" style=\"width: 498px;\"\u003eAccuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 211px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 68px;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 60px;\"\u003e\u003cstrong\u003eMaximum Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 159px;\"\u003e\u003cstrong\u003eIntrinsic Accuracy at Reference Conditions (% of Reading +% of Range)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 211px;\"\u003eVoltage\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 68px;\"\u003e1000 V\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 60px;\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 159px;\"\u003e±0.1 % of nominal voltage \u003csup\u003e1, 2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" rowspan=\"8\" style=\"width: 201px;\"\u003eCurrent: Direct input\u003c\/td\u003e\n\u003ctd class=\"v-top\" rowspan=\"2\" style=\"width: 10px;\"\u003ei17xx-flex 1500IP 24 1500 A\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 68px;\"\u003e150 A\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 60px;\"\u003e0.01 A (min. 1.5A)\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" rowspan=\"2\" style=\"width: 159px;\"\u003e±(1% + 0.02%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 68px;\"\u003e1500 A\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 60px;\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" rowspan=\"2\" style=\"width: 10px;\"\u003ei17xx-flex 3000IP 24 3000 A\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 68px;\"\u003e300 A\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 60px;\"\u003e0.01 A (min. 3.0 A)\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" rowspan=\"2\" style=\"width: 159px;\"\u003e±(1% + 0.03%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 68px;\"\u003e3000 A\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 60px;\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" rowspan=\"2\" style=\"width: 10px;\"\u003ei17xx-flex 6000IP 36 6000 A\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 68px;\"\u003e600 A\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 60px;\"\u003e0.01 A (min. 6.0 A)\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" rowspan=\"2\" style=\"width: 159px;\"\u003e±(1.5% + 0.03%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 68px;\"\u003e6000 A\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 60px;\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" rowspan=\"2\" style=\"width: 10px;\"\u003ei40s-EL clamp\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 68px;\"\u003e4 A\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 60px;\"\u003e1 mA\u003c\/td\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" rowspan=\"2\" style=\"width: 159px;\"\u003e±(0.7% + 0.02%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 68px;\"\u003e40 A\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 60px;\"\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 211px;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 68px;\"\u003e42.5 Hz to 69 Hz\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 60px;\"\u003e0.01 Hz\u003c\/td\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 159px;\"\u003e±(0.1%)\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 211px;\"\u003eAuxiliary input\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 68px;\"\u003e±10 V dc\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 60px;\"\u003e0.1 mV\u003c\/td\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 159px;\"\u003e±(0.2% + 0.02%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 211px;\"\u003eVoltage min\/max\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 68px;\"\u003e1000 V\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 60px;\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 159px;\"\u003e±0.2 % of nominal input voltage\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 211px;\"\u003eCurrent min\/max\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 68px;\"\u003eDefined by accessory\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 60px;\"\u003eDefined by accessory\u003c\/td\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 159px;\"\u003e±(5% + 0.2%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 211px;\"\u003eTHD on voltage\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 68px;\"\u003e1000%\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 60px;\"\u003e0.10%\u003c\/td\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 159px;\"\u003e± 2.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 211px;\"\u003eTHD on current\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 68px;\"\u003e1000%\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 60px;\"\u003e0.10%\u003c\/td\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 159px;\"\u003e± 2.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" rowspan=\"2\" style=\"width: 211px;\"\u003eVoltage harmonics 2nd to 50th\u003c\/td\u003e\n\u003ctd class=\"v-top\" rowspan=\"2\" style=\"width: 68px;\"\u003e1000 V\u003c\/td\u003e\n\u003ctd class=\"v-top\" rowspan=\"2\" style=\"width: 60px;\"\u003e0.1 V\u003c\/td\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 159px;\"\u003e≥ 1 V: ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 159px;\"\u003e\u0026lt; 1 V: ±0.05V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" rowspan=\"2\" style=\"width: 211px;\"\u003eCurrent harmonics 2nd to 50th\u003c\/td\u003e\n\u003ctd class=\"v-top\" rowspan=\"2\" style=\"width: 68px;\"\u003eDefined by accessory\u003c\/td\u003e\n\u003ctd class=\"v-top\" rowspan=\"2\" style=\"width: 60px;\"\u003eDefined by accessory\u003c\/td\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 159px;\"\u003e≥ 3% of current range: ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 159px;\"\u003e\u0026lt; 3% of current range: ±0.15% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 211px;\"\u003eFlicker P\u003csub\u003eLT\u003c\/sub\u003e, P\u003csub\u003eST\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 68px;\"\u003e0 to 20\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 60px;\"\u003e0.01\u003c\/td\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 159px;\"\u003e5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"6\" style=\"width: 498px;\"\u003eCurrent probe accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" rowspan=\"2\" style=\"width: 201px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\" rowspan=\"2\" style=\"width: 10px;\"\u003e\u003cstrong\u003eInfluence quantity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 68px;\"\u003e\u003cstrong\u003eiFlex1500IP-24\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 60px;\"\u003e\u003cstrong\u003eiFlex3000IP-24 \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 82px;\"\u003e\u003cstrong\u003eiFlex6000IP-36\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 77px;\"\u003e\u003cstrong\u003ei40S-EL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 68px;\"\u003e\u003cstrong\u003e150 A \/ 1500 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 60px;\"\u003e\u003cstrong\u003e300 A \/ 3000 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 82px;\"\u003e\u003cstrong\u003e600 A \/ 6000 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 77px;\"\u003e\u003cstrong\u003e4 A \/ 40 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eActive Power P \u003c\/td\u003e\n\u003ctd class=\"v-top\" rowspan=\"2\" style=\"width: 10px;\"\u003ePF ≥ 0.99\u003c\/td\u003e\n\u003ctd class=\"v-top\" rowspan=\"2\" style=\"width: 68px;\"\u003e1.2% + 0.005%\u003c\/td\u003e\n\u003ctd class=\"v-top\" rowspan=\"2\" style=\"width: 60px;\"\u003e1.2% + 0.0075%\u003c\/td\u003e\n\u003ctd class=\"v-top\" rowspan=\"2\" style=\"width: 82px;\"\u003e1.7% + 0.0075%\u003c\/td\u003e\n\u003ctd class=\"v-top\" rowspan=\"2\" style=\"width: 77px;\"\u003e1.2% + 0.005%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eActive Energy E\u003csub\u003ea\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eApparent power S\u003c\/td\u003e\n\u003ctd class=\"v-top\" rowspan=\"2\" style=\"width: 10px;\"\u003e0 ≤ PF ≤ 1\u003c\/td\u003e\n\u003ctd class=\"v-top\" rowspan=\"2\" style=\"width: 68px;\"\u003e1.2% + 0.005%\u003c\/td\u003e\n\u003ctd class=\"v-top\" rowspan=\"2\" style=\"width: 60px;\"\u003e1.2% + 0.0075%\u003c\/td\u003e\n\u003ctd class=\"v-top\" rowspan=\"2\" style=\"width: 82px;\"\u003e1.7% + 0.0075%\u003c\/td\u003e\n\u003ctd class=\"v-top\" rowspan=\"2\" style=\"width: 77px;\"\u003e1.2% + 0.005%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eApparent Energy E\u003csub\u003eap\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eReactive power Q\u003c\/td\u003e\n\u003ctd class=\"v-top\" rowspan=\"2\" style=\"width: 10px;\"\u003e0 ≤ PF ≤ 1\u003c\/td\u003e\n\u003ctd class=\"v-top\" colspan=\"4\" rowspan=\"2\" style=\"width: 287px;\"\u003e2.5% of measured apparent power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eReactive Energy E\u003csub\u003er\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003ePower Factor PF\u003c\/td\u003e\n\u003ctd class=\"v-top\" rowspan=\"3\" style=\"width: 10px;\"\u003e-\u003c\/td\u003e\n\u003ctd class=\"v-top\" colspan=\"4\" rowspan=\"3\" style=\"width: 287px;\"\u003e±0.025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eDisplacement Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eFactor DPF\/cosΦ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eAdditional uncertainty in% of range\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 10px;\"\u003eV\u003csub\u003eP-N\u003c\/sub\u003e\u0026gt;250 V\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 68px;\"\u003e0.015%\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 60px;\"\u003e0.023%\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 82px;\"\u003e0.023%\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 77px;\"\u003e0.015%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"6\" style=\"width: 498px;\"\u003e\n\u003csmall\u003e\u003csup\u003e1\u003c\/sup\u003e\u003c\/small\u003e\u003csmall\u003e In the range of 100 V … 500 V; also known as Udin\u003cbr\u003e\u003csup\u003e2\u003c\/sup\u003e 0 °C … 45 °C: Intrinsic accuracy x 2, outside of 0 °C … 45 °C: Intrinsic accuracy x 3\u003cbr\u003e\u003csup\u003e3\u003c\/sup\u003e Consult operators manual for details\u003cbr\u003e\u003cbr\u003eReference conditions:\u003cbr\u003eEnvironmental: 23 °C ± 5 °C, instrument operating for at least 30 minutes, no external electrical\/magnetic field, RH \u0026lt;65 %\u003cbr\u003eInput conditions: Cosφ\/PF=1, Sinusoidal signal f=50 Hz\/60 Hz, power supply 120 V\/230 V ±10 %.\u003cbr\u003eCurrent and power specifications: Input voltage 1 ph: 120 V\/230 V or 3 ph wye\/delta: 230 V\/400 V\u003cbr\u003eInput current: I \u0026gt; 10 % of I range\u003cbr\u003ePrimary conductor of clamps or Rogowski coil in center position\u003cbr\u003eTemperature coefficient: Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"width: 534px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 518px;\"\u003eElectrical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 518px;\"\u003ePower Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" rowspan=\"2\" style=\"width: 201px;\"\u003eVoltage range\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003e100 V to 500 V using safety plug input when powering from the measurement circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003e100 V to 240 V MA-C8 and using standard power cord (IEC 60320 C7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eMaximum 50 VA (max. 15 VA when powered using MA-C8 adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eEfficiency\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003e≥ 68.2% (in accordance with energy efficiency regulations)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eMaximum no-load consumption\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003e\u0026lt; 0.3 W only when powered using IEC 60320 input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eMains power frequency\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003e50\/60 Hz ±15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eBattery\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eLi-ion 3.7 V, 9.25 Wh, customer-replaceable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eOn-battery runtime\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eTypically 4 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eCharging time\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003e\u0026lt; 6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 518px;\"\u003eData Acquisition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003e16-bit synchronous sampling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eSampling frequency\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003e10.24 kHz at 50\/60 Hz, synchronized to mains frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eInput signal frequency\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003e50\/60 Hz (42.5 to 69 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eCircuit types\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003e1-Φ, 1-Φ IT, split phase, 3-Φ delta, 3-Φ wye, 3-Φwye IT, 3-Φ wye balanced, 3-Φ Aron\/Blondel (2-element delta), 3-Φ delta open leg, currents only (load studies)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eData storage\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eInternal flash memory (not user replaceable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eMemory size\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eTypical 20 logging sessions of 4 weeks with 1-minute intervals and 500 events\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 518px;\"\u003eBasic Interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eMeasured parameters\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eVoltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eAveraging interval\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eUser selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eAveraging time min\/max values\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eVoltage, Current: Full cycle RMS updated every half cycle (URMS1\/2 according to IEC61000-4-30 Aux, Power: 200ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 518px;\"\u003eDemand Interval (Energy Meter Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eMeasured parameters\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eEnergy (Wh, varh, VAh), PF, maximum demand, cost of energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eInterval\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eUser selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 518px;\"\u003ePower Quality Measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eMeasured parameter\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eVoltage, frequency, unbalance, voltage harmonics, THD V, current, harmonics, THD A, TDD, voltage interharmonics, TID V, current interharmonics, TID A, Flicker, Mains Signaling, under\/over deviation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eAveraging interval\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003e10 min for all parameters\u003cbr\u003e2 hrs (long term Flicker PLT)\u003cbr\u003e150\/180 cycles (3 s) for harmonics (requires software license IEEE519\/REPORT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eIndividual harmonics\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003e2nd to 50th harmonic\u003cbr\u003eGrouping according to IEC 61000-4-7 user configurable depending on application: Sub-grouped (harmonics + interharmonics), grouped or harmonic bins only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eInterharmonics\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003e1st to the 50th interharmonic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eTotal harmonic distortion\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eCalculated on 50 voltage harmonics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eEvents\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eVoltage: dips, swells, interruptions, current: inrush current\u003cbr\u003e1748: mains signaling, transients (low frequency)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" rowspan=\"3\" style=\"width: 201px;\"\u003eTriggered recordings\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eRMS profile: Full cycle RMS updated every half cycle of voltage and current up to 11 s (URMS1\/2 according to IEC 61000-4-30)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eWaveform of voltage and current up to 200 ms, 10\/12 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eMains signaling: 10\/12 cycle RMS recording of the configured frequencies up to 120s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eInrush\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eRMS profile based on 1\/2 cycle RMS steady state triggering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eFlicker\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eIn accordance with IEC 61000-4-15 and IEEE 1453\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eMains signaling\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eTwo user defined frequencies up to 3 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003ePQ Health\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eSummarizes power quality measurements in one table. Detailed data available for each parameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eEN 50160\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eCompliance with standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eProgrammable PQ limits\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eEnables user defined limits for local standards compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 518px;\"\u003eStandards Compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" rowspan=\"2\" style=\"width: 201px;\"\u003eHarmonics\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eIEC 61000-4-7: Class 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eIEEE 519 (short time and very short time harmonics)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003ePower quality\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eIEC 61000-4-30 Class A, IEC 62586-1, IEC 62586-2 (PQI-A-PI device)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003ePower\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eIEEE 1459\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003ePower quality compliance\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eEN 50160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" rowspan=\"4\" style=\"width: 201px;\"\u003eSafety\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eGeneral: IEC 61010-1: Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eMeasurement: IEC 61010-2-033: CAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003ePower Supply: Overvoltage Category IV, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eLi-ion Battery: IEC 62133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 518px;\"\u003eInterfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eUSB-A\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eFile transfer via USB flash drive, firmware updates, max. supply current: 120 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eWi-Fi (free with product registration)\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eFile transfer and remote control via direct connection or Wi-Fi infrastructure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eBluetooth\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eRead auxiliary measurement data from Fluke Connect® 3000 series modules (requires supported USB to BLE or Wi-Fi\/BLE adapter, check for availability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eUSB-mini\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003eData download device to PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" colspan=\"2\" style=\"width: 518px;\"\u003eVoltage Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eNumber of inputs\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003e4 (3 phases referenced to neutral)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eMaximum input voltage\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003e1000 Vrms, CF 1.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-top\" style=\"width: 201px;\"\u003eInput impedance\u003c\/td\u003e\n\u003ctd class=\"v-top\" style=\"width: 317px;\"\u003e10 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"v-to\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504305778773,"sku":"Fluke 1746\/15\/INTL","price":2818816.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/Fluke174615EUS-Main.jpg?v=1598866785"},{"product_id":"fluke-830-laser-alignment-tool","title":"Fluke 830  Laser Alignment Tool","description":"\u003ch2\u003eProduct overview: Fluke 830 Laser Shaft Alignment Tool\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cstrong\u003eThe Fluke 830 Laser Shaft Alignment Tool is the ideal test tool to precision-align rotating shafts in your facility.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt's a known fact - all rotating machinery is susceptible to misalignment. If you're still using rulers and dial indicators to ensure your rotating machinery is properly aligned, you could be losing thousands of dollars per year in replacement bearing costs, hours of unnecessary repair time, and crippling unplanned downtime, not to mention taking years off your machine's useful life.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 830 Laser Shaft Alignment tool is easy-to-use, giving you fast, accurate and actionable answers that will keep your plant up and running. When it comes to laser shaft alignment, data is good but answers are better.\u003c\/p\u003e\n\u003cp\u003eUnlike using the straightedge method or dial indicators the Fluke 830 performs the complicated alignment calculations for you, meaning you'll have the answers you need to quickly align your machine and get your plant up and running fast. An enhanced user interface provides easy to understand results that don't require extensive alignment knowledge and the unique \"All-in-One\" result screen that shows you both coupling results and feet corrections (vertical and horizontal) in real terms making it easy to take corrective action.\u003c\/p\u003e\n\u003cp\u003eSince machine downtime is costly, test repeatability is critical. The Fluke 830 uses a patented single laser precision alignment system that provides accurate and repeatable measurement results so you can be assured you're addressing misalignment problems properly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes a unique “All-in-One” result screen that shows both coupling results and vertical and horizontal feet corrections, making it easy to take corrective action\u003c\/li\u003e\n\u003cli\u003eFeatures a dynamic machine tolerance check that provides continuous evaluation of alignment adjustments so you know when your machine is in the acceptable range\u003c\/li\u003e\n\u003cli\u003eOffers unique extend mode to handle gross misalignment by virtually increasing laser detector size\u003c\/li\u003e\n\u003cli\u003eProvides auto save and resume capability to ensure your data is there when you need it\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eKey features\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasy to use tool for precision alignment of rotating shafts\u003c\/li\u003e\n\u003cli\u003eFeatures single laser measurement technology to reduce errors from backlash and enhance accuracy\u003c\/li\u003e\n\u003cli\u003eProvides an intuitive, guided user interface to quickly and easily complete machine alignments\u003c\/li\u003e\n\u003cli\u003eIncludes compass measurement mode to enable flexible, reliable, and repeatable measurements using an activated electronic inclinometer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504311906389,"sku":"Fluke 830","price":4934864.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/fluke-830-shaft-laser-alignment-tool.jpg?v=1599060041"},{"product_id":"fluke-750pa27-pressure-module-0-20bar","title":"Fluke  750PA27 pressure-module  (0 - 20 bar)","description":"\u003ch2\u003eProduct overview: Fluke 750P Series Pressure Modules\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 750P Series Pressure Modules\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFluke 750P Series Pressure Modules will turn your Fluke multifunction calibrator\u003cspan\u003e \u003c\/span\u003einto a full-fledged pressure calibrator. These flexible modules not only work with multifunction calibrators like the\u003cspan\u003e 725\u003c\/span\u003e,\u003cspan\u003e 726\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eor 750 Series Calibrators but also extend the measurement range of Fluke pressure calibrators. Since the pressure modules are calibrated independently, they can be swapped from one calibrator to another without a loss of accuracy or traceability.\u003c\/p\u003e\n\u003cp\u003eMeasuring pressure with Fluke 750P Series Pressure Modules\u003cspan\u003e \u003c\/span\u003eis as easy as connecting the module to a pressure source or hand pump, connecting the pressure module cable to the calibrator and then applying pressure from the pressure source. At the touch of a button the measured pressure is displayed digitally on the calibrator in up to 11 different engineering units quickly giving you the data you need. When used with the 750 Series Documenting Process Calibrators pressure readings can even be date\/time stamped and stored in documented calibration records for later retrieval. This saves time, eliminates errors and supports compliance with quality standards and regulations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA complete family of pressure modules\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith over 50 pressure modules covering pressure calibration and measurement workloads from 1 inH20 to 10,000 psi (2.5 mBar to 690 bar) finding a model to meet the needs of your specific application is easier than ever. All modules include NPT, metric (BSP) and M20 adapters.\u003c\/p\u003e\n\u003cp\u003eChoose from:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDifferential modules\u003c\/li\u003e\n\u003cli\u003eGage modules\u003c\/li\u003e\n\u003cli\u003eHigh pressure modules\u003c\/li\u003e\n\u003cli\u003eAbsolute modules\u003c\/li\u003e\n\u003cli\u003eVacuum modules\u003c\/li\u003e\n\u003cli\u003eDual range modules\u003c\/li\u003e\n\u003cli\u003eReference modules\u003c\/li\u003e\n\u003cli\u003eIntrinsically safe modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWith more than 50 pressure modules to choose from, some of the more popular modules include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 750P00\u003c\/li\u003e\n\u003cli\u003eFluke 750P02\u003c\/li\u003e\n\u003cli\u003eFluke 750PD2\u003c\/li\u003e\n\u003cli\u003eFluke 750P03\u003c\/li\u003e\n\u003cli\u003eFluke 750P05\u003c\/li\u003e\n\u003cli\u003eFluke 750P06\u003c\/li\u003e\n\u003cli\u003eFluke 750P29\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eClick the Models tab for a full list of pressure modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDesigned to go where you work\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePressure instruments are often installed in harsh, hard to reach locations, so you need test tools that handle rough service. 750P Series Pressure Modules feature a rugged protective boot that guards the module against shock and seals against dirt and dust, if you accidently drop them, there’s no need to worry. The 750P series modules are also specified across a broad temperature range. Though more accurate across a narrower temperature range if used indoors, these modules are designed and specified to deliver traceable pressure measurements in environments from -10 °C to +50 °C.\u003c\/p\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003eA complete family of precision pressure modules\u003c\/li\u003e\n\u003cli\u003eModule, NPT, BSP and M20 adapters, and certificate of calibration\u003c\/li\u003e\n\u003cli\u003eReduce errors by digitally sending measurements to calibrators\u003c\/li\u003e\n\u003cli\u003eMake accurate pressure measurements; reference uncertainties up to 0.01%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 750P Series Pressure Modules\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"6\" style=\"width: 484px;\"\u003eDifferential Module Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003eModel\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e\u003cb\u003eParameter \/ range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e\u003cb\u003eBurst rating\u003csup\u003e6\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e\u003cb\u003eHi side media\u003csup\u003e2\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e\u003cb\u003eLo side media\u003csup\u003e2\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P00\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 1 inH\u003csub\u003e2\u003c\/sub\u003eO (0 to 2.5 mBar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e30X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003eDry air\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eDry air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P3IN\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 3 Inch H2O (0 to 7.5 mbar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e10X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003eDry air\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eDry air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P5IN\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 5 Inch H2O (0 to 12.5 mbar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e6X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003eDry air\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eDry air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P01\u003csup\u003e7\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 10 inH\u003csub\u003e2\u003c\/sub\u003eO (0 to 25 mBar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e3X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003eDry air\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eDry air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P02\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 1 psi (0 to 70 mBar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e3X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003eDry air\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eDry air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P22\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 1 psi (0 to 70 mBar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e3X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eDry air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P03\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 5 psi (0 to 350 mBar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e3X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003eDry air\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eDry air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P23\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 5 psi (0 to 350 mBar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eDry air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P04\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 15 psi (0 to 1 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e3X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003eDry air\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eDry air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P24\u003csup\u003e7\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 15 psi (0 to 1 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eDry air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e\u003cb\u003eReference uncertainty\u003csup\u003e4\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e1-year\u003cbr\u003e(15-35°C)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e1-year\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e6-month\u003cbr\u003e(15-35°C)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e6-month\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P00\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.15%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.3%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.35%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.25%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.30%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P3IN\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.15%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.3%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.35%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.25%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.30%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P5IN\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.15%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.3%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.35%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.25%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.30%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P01\u003csup\u003e7\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.1%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.2%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.3%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.15%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.25%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P02\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.050%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.1%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.15%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.075%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.125%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P22\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.050%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.1%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.15%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.075%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.125%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P03\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.02%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.04%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.05%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.035%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.04%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P23\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.02%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.04%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.05%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.035%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.04%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P04\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.0175%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.035%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.045%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.04%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P24\u003csup\u003e7\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.0175%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.035%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.045%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.04%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"6\" style=\"width: 484px;\"\u003eGage Module Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003eModel\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e\u003cb\u003eParameter \/ range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e\u003cb\u003eBurst rating\u003csup\u003e6\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e\u003cb\u003eHi side media\u003csup\u003e2\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e\u003cb\u003eLo side media\u003csup\u003e2\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P05\u003csup\u003e7\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 30 psi (0 to 2 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P06\u003csup\u003e7\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 100 psi (0 to 7 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P27\u003csup\u003e7\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 300 psi (0 to 20 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P07\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 500 psi (0 to 35 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P08\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 1000 psi (0 to 70 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e3X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P09\u003csup\u003e7\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 1500 psi (0 to 100 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e3X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P2000\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 2000 psi (0 to 140 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e3X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e\u003cb\u003eReference uncertainty\u003csup\u003e4\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e1-year\u003cbr\u003e(15-35°C)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e1-year\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e6-month\u003cbr\u003e(15-35°C)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e6-month\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P05\u003csup\u003e7\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.0175%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.035%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.045%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.04%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P06\u003csup\u003e7\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.0175%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.035%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.045%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.04%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P27\u003csup\u003e7\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.0175%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.035%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.045%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.04%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P07\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.0175%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.035%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.045%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.04%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P08\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.0175%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.035%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.045%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.04%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P09\u003csup\u003e7\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.0175%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.035%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e± 0.045%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.04%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P2000\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.0175%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.035%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e± 0.045%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.04%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"6\" style=\"width: 484px;\"\u003eHigh Pressure Module Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003eModel\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e\u003cb\u003eParameter \/ range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e\u003cb\u003eBurst rating\u003csup\u003e6\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e\u003cb\u003eHi side media\u003csup\u003e2\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e\u003cb\u003eLo side media\u003csup\u003e2\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P29\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 3000 psi (0 to 200 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e3X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P30\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 5000 psi (0 to 340 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e3X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P31\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 10000 psi (0 to 700 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e2X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e\u003cb\u003eReference uncertainty\u003csup\u003e4\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e1-year\u003cbr\u003e(15-35°C)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e1-year\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e6-month\u003cbr\u003e(15-35°C)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e6-month\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P29\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.0175%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.035%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.045%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.04%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P30\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.0175%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.035%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.045%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.04%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750P31\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.0175%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.035%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.045%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.04%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"6\" style=\"width: 484px;\"\u003eAbsolute Module Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003eModel\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e\u003cb\u003eParameter \/ range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e\u003cb\u003eBurst rating\u003csup\u003e6\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e\u003cb\u003eHi side media\u003csup\u003e2\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e\u003cb\u003eLo side media\u003csup\u003e2\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PA3\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 5 psia (0 to 350 mBar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PA4\u003csup\u003e7\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 15 psia (0 to 1 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PA5\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 30 psia (0 to 2 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PA6\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 100 psia (0 to 7 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PA27\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 300 psia (0 to 20 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PA7\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 500 psia (0 to 35 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PA8\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 1000 psia (0 to 70 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e3X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PA9\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 1500 psia (0 to 100 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e3X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e\u003cb\u003eReference uncertainty\u003csup\u003e4\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e1-year\u003cbr\u003e(15-35°C)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e1-year\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e6-month\u003cbr\u003e(15-35°C)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e6-month\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PA3\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.06%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.07%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.05%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.06%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PA4\u003csup\u003e7\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.06%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.07%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.05%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.06%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PA5\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.06%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.07%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.05%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.06%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PA6\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.06%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.07%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.05%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.06%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e750PA27\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e±0.03%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e±0.06%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e±0.07%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e±0.05%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e±0.06%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PA7\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.06%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.07%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.05%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.06%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PA8\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.06%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.07%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.05%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.06%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PA9\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.06%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.07%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.05%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.06%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"6\" style=\"width: 484px;\"\u003eVacuum Module Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003eModel\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e\u003cb\u003eParameter \/ range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e\u003cb\u003eBurst rating\u003csup\u003e6\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e\u003cb\u003eHi side media\u003csup\u003e2\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e\u003cb\u003eLo side media\u003csup\u003e2\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PV3\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e-5 psi (-350 mBar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eDry air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PV4\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e-15 psi (-1 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eDry air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e\u003cb\u003eReference uncertainty\u003csup\u003e4\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e1-year\u003cbr\u003e(15-35°C)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e1-year\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e6-month\u003cbr\u003e(15-35°C)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e6-month\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PV3\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.06%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.07%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.05%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.06%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PV4\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.06%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.07%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.05%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.06%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"6\" style=\"width: 484px;\"\u003eDual Range Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003eModel\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e\u003cb\u003eParameter \/ range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e\u003cb\u003eBurst rating\u003csup\u003e6\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e\u003cb\u003eHi side media\u003csup\u003e2\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e\u003cb\u003eLo side media\u003csup\u003e2\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PD2\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e-1 to 1 psi (-70 to 70 mBar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eDry air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PD3\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e-5 to 5 psi (-350 to 350 mBar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eDry air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PD10\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e-10 to 10 psi (-700 to 700 mBar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eDry air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PD4\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e-15 to 15 psi (-1 to 1 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eDry air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PD5\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e-15 to 30 psi (-1 to 2 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PD50\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e-15 to 50 psi (-1 to 3.5 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PD6\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e-15 to 100 psi (-1 to 7 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PD7\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e-15 to 200 psi (-1 to 14 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PD27\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e-15 to 300 psi (-1 to 20 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e\u003cb\u003eReference uncertainty\u003csup\u003e4\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e1-year\u003cbr\u003e(15-35°C)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e1-year\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e6-month\u003cbr\u003e(15-35°C)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e6-month\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PD2\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.05%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.1%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.15%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.075%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.125%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PD3\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.06%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.07%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.05%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.06%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PD10\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.025%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.05%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.07%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.04%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.06%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PD4\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.0175%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.035%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.045%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e± 0.04%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PD5\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e± 0.0175%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e± 0.035%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e± 0.045%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e± 0.04%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PD50\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e± 0.0175%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e± 0.035%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e± 0.045%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e± 0.04%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PD6\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e± 0.0175%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e± 0.035%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e± 0.045%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e± 0.04%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PD7\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e± 0.0175%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e± 0.035%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e± 0.045%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e± 0.04%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750PD27\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e± 0.0175%\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e± 0.035%\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e± 0.045%\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e± 0.04%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"6\" style=\"width: 484px;\"\u003eReference Module Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003eModel\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e\u003cb\u003eParameter \/ range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e\u003cb\u003eBurst rating\u003csup\u003e6\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e\u003cb\u003eHi side media\u003csup\u003e2\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e\u003cb\u003eLo side media\u003csup\u003e2\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750R04\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 15 psi (0 to 1 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e3X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003eDry air\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003eDry air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750R06\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 100 psi (0 to 7 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750R27\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 300 psi (0 to 20 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750R07\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 500 psi (0 to 35 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750R08\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 1000 psi (0 to 70 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e3X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750R29\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 3000 psi (0 to 200 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e3X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750R30\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 5000 psi (0 to 340 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e3X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750R31\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e0 to 10000 psi (0 to 700 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e2X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750RD5\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e-15 to 30 psi (-1 to 2 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003eDry air\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750RD6\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e-12 to 100 psi (-0.8 to 7 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750RD27\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 169px;\"\u003e-12 to 300 psi (-0.8 to 20 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e4X\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e\u003cb\u003eReference uncertainty\u003csup\u003e4\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e1-year\u003cbr\u003e(15-35°C)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e1-year\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e6-month\u003cbr\u003e(15-35°C)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e6-month\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750R04\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.01% of FS\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.02% of FS\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.04% of FS\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.015% of FS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.035% of FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750R06\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.01% of FS\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.02% of FS\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.04% of FS\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.015% of FS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.035% of FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750R27\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.01% of FS\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.02% of FS\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.04% of FS\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.015% of FS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.035% of FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750R07\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.01% of FS\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.02% of FS\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.04% of FS\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.015% of FS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.035% of FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 62px;\"\u003e750R08\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 95px;\"\u003e±0.01% of FS\u003c\/td\u003e\n\u003ctd style=\"width: 74px;\"\u003e±0.02% of FS\u003c\/td\u003e\n\u003ctd style=\"width: 96.3333px;\"\u003e±0.04% of FS\u003c\/td\u003e\n\u003ctd style=\"width: 76.6667px;\"\u003e±0.015% of FS\u003c\/td\u003e\n\u003ctd style=\"width: 80px;\"\u003e±0.035% of FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504317771861,"sku":"Fluke 750PA27","price":1036244.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/7506.jpg?v=1599564683"},{"product_id":"fluke-750r08-pressure-module-0-70bar","title":"Fluke  750R08 pressure-module  (0 - 70 bar)","description":"\u003cp\u003eFLUKE-750R08  FLUKE-750R08,PRESSURE MODULE, 0 TO 1000 (0 TO 70 BAR), (0 TO 7000 KPA)\u003c\/p\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504321671253,"sku":"Fluke 750R08","price":1016400.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/fluke-750r08-pressure-module.jpg?v=1622120521"}],"url":"https:\/\/www.gilautomation.com\/pt-ao\/collections\/best-selling-collection.oembed?page=521","provider":"gilautomation","version":"1.0","type":"link"}