{"product_id":"fluke-117-true-rms-multimeter","title":"Fluke 117 True RMS multimeter","description":"\u003ch2\u003eProduct overview: Fluke 117 Electricians Multimeter with Non-Contact voltage\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003ch2\u003eFluke 117 Digital Multimeter for Electricians with Non-Contact voltage\u003c\/h2\u003e\n\u003cp\u003eThis Digital Multimeter includes integrated non-contact voltage detection to help get the job done faster.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 117 Digital Multimeter includes integrated non-contact voltage detection and Auto Volts and LoZ functions that help prevent false readings caused by ghost voltage. It is a compact True-RMS meter for demanding applications like commercial buildings, hospitals, and schools and helps get the job done faster.\u003c\/p\u003e\n\u003cp\u003eUsers around the world have said their 117 digital multimeter is an investment in accuracy. The Fluke 117 provides Min\/Max\/Average readings and measures frequency and capacitance. Plus, its easy-to-use interface can save you time and enable you to move from job to job more quickly.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 110 Series has five true-rms digital multimeters, each for specific users. The compact instruments offer convenient one-handed operation and a backlit display with large, easy-to-read digits.\u003c\/p\u003e\n\u003cp\u003eOther useful features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAccurate, easy-to-use multimeter with integrated VoltAlert™ technology for non-contact voltage detection\u003c\/li\u003e\n\u003cli\u003eFeatures AutoVolt automatic AC\/DC voltage selection\u003c\/li\u003e\n\u003cli\u003eProvides low input impedance to help prevent false readings due to ghost voltage\u003c\/li\u003e\n\u003cli\u003ePresents a large white LED backlight for working in poorly lit areas\u003c\/li\u003e\n\u003cli\u003eFeatures True RMS capabilities for accurate measurements on non-linear loads\u003c\/li\u003e\n\u003cli\u003eMeasures 10 A (20 A overload for 30-seconds)\u003c\/li\u003e\n\u003cli\u003eMeasures resistance, continuity, frequency, and capacitance\u003c\/li\u003e\n\u003cli\u003eProvides Min\/Max\/Average to record signal fluctuations\u003c\/li\u003e\n\u003cli\u003eComes with an holster with probe holders for easy storage\u003c\/li\u003e\n\u003cli\u003eFeatures compact ergonomic design for one-handed operation\u003c\/li\u003e\n\u003cli\u003eFits into optional ToolPak™ magnetic hanger for hands-free operation\u003c\/li\u003e\n\u003cli\u003eCAT III 600 V safety rated\u003c\/li\u003e\n\u003cli\u003eA large white LED backlight to improve measurement visibility in poorly lit areas\u003c\/li\u003e\n\u003cli\u003eVoltAlert™ technology for fast, go\/no go non-contact voltage detection\u003c\/li\u003e\n\u003cli\u003eAutoVolt and low input impedance modes to provide faster, more accurate readings\u003c\/li\u003e\n\u003cli\u003eFor commercial electricians, commercial and residential electrical work\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e4 mm silicone test lead set\u003c\/li\u003e\n\u003cli\u003eHolster\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 117 Electricians Multimeter with Non-Contact voltage\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 502px;\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.667px;\"\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 351.333px;\"\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.667px;\"\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 351.333px;\"\u003eIEC 61010-1: Pollution Degree 2\u003cbr\u003eIEC 61010-2-033: CAT III 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.667px;\"\u003eFuse for A input\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 351.333px;\"\u003e11 A, 1000 V FAST Fuse (Fluke PN 803293)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.667px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 351.333px;\"\u003eDigital: 6,000 counts, updates 4 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.667px;\"\u003eBar graph\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 351.333px;\"\u003e33 segments, updates 32 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.667px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 351.333px;\"\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.667px;\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 351.333px;\"\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.667px;\"\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 351.333px;\"\u003e9 volt Alkaline, IEC 6LR61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.667px;\"\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 351.333px;\"\u003e400 hours typical, without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 502px;\"\u003eAccuracy Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 150.667px;\"\u003eDC millivolts\u003c\/td\u003e\n\u003ctd style=\"width: 147.333px;\"\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.333px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e±([% of reading] + [counts]): 0.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 150.667px;\"\u003eDC volts\u003c\/td\u003e\n\u003ctd style=\"width: 147.333px;\"\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.00 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.333px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e±([% of reading] + [counts]): 0.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 150.667px;\"\u003eAuto volts\u003c\/td\u003e\n\u003ctd style=\"width: 147.333px;\"\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e600.0 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.333px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e2.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e4.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 150.667px;\"\u003eAC millivolts¹ True RMS\u003c\/td\u003e\n\u003ctd style=\"width: 147.333px;\"\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.333px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e1.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e2.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 150.667px;\"\u003eAC volts¹ True RMS\u003c\/td\u003e\n\u003ctd style=\"width: 147.333px;\"\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.0 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.333px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e1.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e2.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 150.667px;\"\u003eContinuity\u003c\/td\u003e\n\u003ctd style=\"width: 147.333px;\"\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e600 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.333px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003eBeeper on \u0026lt; 20 Ω, off \u0026gt; 250 Ω detects opens or shorts of\u003cbr\u003e500 μs or longer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 150.667px;\"\u003eOhms\u003c\/td\u003e\n\u003ctd style=\"width: 147.333px;\"\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e600.0 Ω \/ 0.1 Ω\u003cbr\u003e6.000 kΩ \/ 0.001 kΩ\u003cbr\u003e60.00 kΩ \/ 0.01 kΩ\u003cbr\u003e600.0 kΩ \/ 0.1 kΩ\u003cbr\u003e6.000 MΩ \/ 0.001 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.333px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e0.9% + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.333px;\"\u003eRange\/resolution\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e40.00 MΩ \/ 0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.333px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 150.667px;\"\u003eDiode test\u003c\/td\u003e\n\u003ctd style=\"width: 147.333px;\"\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e2.00 V \/ 0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.333px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e0.9% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"width: 150.667px;\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd style=\"width: 147.333px;\"\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e1000 nF \/ 1 nF\u003cbr\u003e10.00 μF \/ 0.01 μF\u003cbr\u003e100.0 μF \/ 0.1 μF\u003cbr\u003e9999 μF \/ 1 μF\u003cbr\u003e100 μF to 1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.333px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e1.9% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.333px;\"\u003eRange\/resolution\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e\u0026gt; 1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.333px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e5% + 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 150.667px;\"\u003eLo-Z capacitance\u003c\/td\u003e\n\u003ctd style=\"width: 147.333px;\"\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e1 nF to 500 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.333px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e10% + 2 typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 150.667px;\"\u003eAC amps True RMS (45 Hz to 500 Hz)\u003c\/td\u003e\n\u003ctd style=\"width: 147.333px;\"\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e6.000 A \/ 0.001 A\u003cbr\u003e10.00 A \/ 0.01 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.333px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e1.5% + 3\u003cbr\u003e20 A continuous overload for 30 seconds max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 150.667px;\"\u003eDC amps\u003c\/td\u003e\n\u003ctd style=\"width: 147.333px;\"\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e\n\u003cp\u003e6.000 A \/ 0.001 A   10.00 A \/ 0.01 A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.333px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e1.0% + 3\u003cbr\u003e20 A continuous overload for 30 seconds max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" style=\"width: 150.667px;\"\u003eHz (V or A input)²\u003c\/td\u003e\n\u003ctd style=\"width: 147.333px;\"\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e99.99 Hz \/ 0.01 Hz\u003cbr\u003e999.9 Hz \/ 0.1 Hz\u003cbr\u003e9.999 kHz \/ 0.001 Hz\u003cbr\u003e50.00 kHz \/ 0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 147.333px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 204px;\"\u003e0.1% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"3\" style=\"width: 502px;\"\u003e1. All AC voltage ranges except Auto-V\/LoZ are specified from 1% to 100% of range. Auto-V\/LoZ is specified from 0.0 V.\u003cbr\u003e2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.\u003cbr\u003e2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.\u003cbr\u003e2. Temperature Range\/Resolution: -40°F to 752°F \/ 0.2°F.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 502px;\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.667px;\"\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 351.333px;\"\u003e167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.667px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 351.333px;\"\u003e550 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 150.667px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 351.333px;\"\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32434177900629,"sku":"Fluke 117","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/24_bfbafe82-00bf-406d-a313-0fe02328f852.jpg?v=1591888069","url":"https:\/\/www.gilautomation.com\/pt-ao\/products\/fluke-117-true-rms-multimeter","provider":"gilautomation","version":"1.0","type":"link"}