{"product_id":"fluke-438-ii-power-quality-motor-analyzer","title":"Fluke 438-II Power Quality \u0026motor Analyzer","description":"\u003ch2\u003eProduct overview: Fluke 438-II Power Quality Analyzer \u0026amp; Motor Analyzer\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cstrong\u003eQuickly and easily discover electrical and mechanical performance of electric motors, and evaluate power quality with a single test tool\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 438-II Power Quality and Motor Analyzer adds key mechanical measurement capabilities for electric motors to the advanced power quality analysis functions of the\u003cspan\u003e \u003c\/span\u003eFluke 435 Series II Power Quality Analyzers  . Quickly and easily measure and analyze key electrical and mechanical performance parameters such as power, harmonics, unbalance, motor speed, torque and mechanical power without the need of mechanical sensors. Fluke 434-II, 435-II and 437-II Power Quality Analyzer users can add motor analysis capabilities to their existing units with the Fluke-438-II\/MA Motor Analyzer upgrade kit. The 438-II uses data from the motor rating plate for either NEMA or IEC rated motors to aid the calculation of the mechanical parameters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCalculates mechanical power and efficiency without mechanical sensors. Just connect to the input conductors\u003c\/li\u003e\n\u003cli\u003eMeasures electrical power parameters such as voltage, current, power, apparent power, power factor, harmonic distortion and unbalance to identify characteristics that impact motor efficiency\u003c\/li\u003e\n\u003cli\u003eIdentify power quality issues such as dips, swells, transients, harmonics and unbalance\u003c\/li\u003e\n\u003cli\u003eUses PowerWave data capture to capture fast RMS data, and show half-cycle averages and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.)\u003c\/li\u003e\n\u003cli\u003eOffers waveform capture function to capture 100\/120 cycles (50\/60 Hz) of each detected event, in all modes, without set-up\u003c\/li\u003e\n\u003cli\u003eUses automatic transient mode to capture waveform data at 200 kS\/s on all phases simultaneously up to 6 kV\u003c\/li\u003e\n\u003cli\u003eAutomatically calculate motor derating according to NEMA\/IEC guidelines\u003c\/li\u003e\n\u003cli\u003eFluke Connect® compatible so you can view data locally on the instrument, via Fluke Connect mobile app and PowerLog 430-II desktop software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cp\u003eThe 438-II Power Quality Analyzer \u0026amp; Motor Analyzer helps you effectively evaluate electrical and mechanical performance just by hooking up voltage and measuring current, providing you with an unprecedented level of data.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBrings key motor analysis parameters like speed, torque and mechanical power and calculates motor efficiency without mechanical sensors\u003c\/li\u003e\n\u003cli\u003eIncludes full power quality and electrical energy analyzer functionality\u003c\/li\u003e\n\u003cli\u003eHighest safety rating in industry; 1000 V CAT III \/ 600 V CAT IV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 438-II Power Quality Analyzer \u0026amp; Motor Analyzer\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cp\u003eAmps (accuracy excluding clamp accuracy)\u003c\/p\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eDrive Measurement Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Type\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e3 phase asynchronous (induction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eVariable Frequency Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Frequency Range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e40Hz to 70Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver\/Under Voltage from Nominal V\/f Curve (%)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-15% to +15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrier Frequency Range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2.5kHz–20kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eVariable speed drive technology that is covered by the 438-II\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eVSI only (voltage controlled) *\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eV\/f control, open-loop vector, closed loop vector, drives with encoders.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e40 to 70 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\u003csmall\u003e* VSI drives are the most common drives. The alternative CSI drives are used in higher power applications.\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eVariable speed drive technology NOT covered by the 438-II\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eCSI (current source inverter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotors type\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eSynchronous (DC, stepper, permanent magnet etc.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026lt;40 and \u0026gt;70 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eMechanical specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eMechanical measurements can be performed on direct online motors with a 3 wire connection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eMotor measurement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefault limit\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical motor\u003cbr\u003e\u003cbr\u003ePower\u003c\/td\u003e\n\u003ctd\u003e0.7 kW to 746 kW\u003cbr\u003e\u003cbr\u003e1 hp to 1000 hp\u003c\/td\u003e\n\u003ctd\u003e0.1 kW\u003cbr\u003e\u003cbr\u003e0.1 hp\u003c\/td\u003e\n\u003ctd\u003e±3%\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cbr\u003e\u003cbr\u003e±3%\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e100% = rated power\u003cbr\u003e\u003cbr\u003e100% = rated power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTorque\u003c\/td\u003e\n\u003ctd\u003e0 Nm to 10 000 Nm\u003cbr\u003e\u003cbr\u003e0 lb ft to 10 000 lb ft\u003c\/td\u003e\n\u003ctd\u003e0.1 Nm\u003cbr\u003e\u003cbr\u003e0.1 lb ft\u003c\/td\u003e\n\u003ctd\u003e±5%\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\u003cbr\u003e\u003cbr\u003e±5%\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e100% = rated torque\u003cbr\u003e\u003cbr\u003e100% = rated torque\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003erpm\u003c\/td\u003e\n\u003ctd\u003e0 rpm to 3600 rpm\u003c\/td\u003e\n\u003ctd\u003e1 rpm\u003c\/td\u003e\n\u003ctd\u003e±3%\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e100% = rated rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.10%\u003c\/td\u003e\n\u003ctd\u003e±3%\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnbalance (NEMA)\u003c\/td\u003e\n\u003ctd\u003e0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.10%\u003c\/td\u003e\n\u003ctd\u003e±0.15%\u003c\/td\u003e\n\u003ctd\u003e5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonics Voltage\u003cbr\u003eFactor (NEMA)\u003c\/td\u003e\n\u003ctd\u003e0 to 0.20\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003e±1.5%\u003c\/td\u003e\n\u003ctd\u003e0.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnbalance Derating\u003cbr\u003eFactor\u003c\/td\u003e\n\u003ctd\u003e0.7 to 1.0\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003eindicative\u003c\/td\u003e\n\u003ctd\u003eNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonics Derating\u003cbr\u003eFactor\u003c\/td\u003e\n\u003ctd\u003e0.7 to 1.0\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003eindicative\u003c\/td\u003e\n\u003ctd\u003eNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal NEMA Derating\u003cbr\u003eFactor\u003c\/td\u003e\n\u003ctd\u003e0.5 to 1.0\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003ctd\u003eindicative\u003c\/td\u003e\n\u003ctd\u003eNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eNotes:\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eSupports motor design types NEMA A, B, C, D \u0026amp; E and IEC type H and N.\u003cbr\u003eRated torque is calculated from rated power and rated speed.\u003cbr\u003eUpdate rate of Motor Measurements is 1x per second.\u003cbr\u003eDefault Trend duration is 1 week.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\u003csmall\u003e\u003csup\u003e1\u003c\/sup\u003eAdd 5% error when selecting Motor design type Other\u003cbr\u003eSpecification valid for Motor Power \u0026gt; 30% of rated power\u003cbr\u003eSpecification valid at stable operating temperature. Run the motor for at least 1 hour at full load\u003cbr\u003e(2-3 hours if the motor is 50 HP or higher) to obtain stable temperature\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eProduct Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolt\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eModel\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMeasurement Range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVrms (AC + DC)\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 V to 1000 V phase to neutral\u003c\/td\u003e\n\u003ctd\u003e0.01 V\u003c\/td\u003e\n\u003ctd\u003e±0.1% of nominal voltage\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVpk\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 Vpk to 1400 Vpk\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003ctd\u003e5% of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Crest Factor (CF)\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.0 \u0026gt; 2.8\u003c\/td\u003e\n\u003ctd\u003e0.01\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVrms½\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e±0.2% of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVfund\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e±0.1% of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr colspan=\"5\"\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eAmps (AC + DC)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei430-Flex 1x \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A to 6000 A\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ei430-Flex 10x\u003c\/td\u003e\n\u003ctd\u003e0.5 A to 600 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1mV\/A 1x\u003c\/td\u003e\n\u003ctd\u003e5 A to 2000 A\u003c\/td\u003e\n\u003ctd\u003e1A\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1mV\/A 10x\u003c\/td\u003e\n\u003ctd\u003e0.5 A A to 200 A (AC only)\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eApk\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei430-Flex\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e8400 Apk\u003c\/td\u003e\n\u003ctd\u003e1 Arms\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1mV\/A\u003c\/td\u003e\n\u003ctd\u003e5500 Apk\u003c\/td\u003e\n\u003ctd\u003e1 Arms\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA Crest Factor (CF)\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 to 10\u003c\/td\u003e\n\u003ctd\u003e0.01\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eAmps½\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei430-Flex 1x\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A to 6000 A\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003ctd\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ei430-Flex 10x\u003c\/td\u003e\n\u003ctd\u003e0.5 A to 600 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1mV\/A 1x\u003c\/td\u003e\n\u003ctd\u003e5 A to 2000 A\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003ctd\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1mV\/A 10x\u003c\/td\u003e\n\u003ctd\u003e0.5 A A to 200 A (AC only)\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eAfund\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei430-Flex 1x\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A to 6000 A\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ei430-Flex 10x\u003c\/td\u003e\n\u003ctd\u003e0.5 A to 600 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1mV\/A 1x\u003c\/td\u003e\n\u003ctd\u003e5 A to 2000 A\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1mV\/A 10x\u003c\/td\u003e\n\u003ctd\u003e0.5 A A to 200 A (AC only)\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±0.5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eHz\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eFluke 434 @ 50 Hz Nominal\u003c\/td\u003e\n\u003ctd class=\"nobold\"\u003e42.50 Hz to 57.50 Hz\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003c\/td\u003e\n\u003ctd\u003e±0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eFluke 434 @ 60 Hz Nominal\u003c\/td\u003e\n\u003ctd\u003e51.00 Hz to 69.00 Hz\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003c\/td\u003e\n\u003ctd\u003e±0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003ePower\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eWatts (VA, var)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei430-Flex\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003emax 6000 MW\u003c\/td\u003e\n\u003ctd\u003e0.1 W to 1 MW\u003c\/td\u003e\n\u003ctd\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 mV\/A\u003c\/td\u003e\n\u003ctd\u003emax 2000 MW\u003c\/td\u003e\n\u003ctd\u003e0.1 W to 1 MW\u003c\/td\u003e\n\u003ctd\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ePower Factor (Cos j\/DPF)\u003c\/td\u003e\n\u003ctd\u003e0 to 1\u003c\/td\u003e\n\u003ctd\u003e0.001\u003c\/td\u003e\n\u003ctd\u003e±0.1% @ nominal load conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eEnergy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ekWh (kVAh, kvarh)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei430-Flex 10x\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eDepends on clamp scaling and V nominal\u003c\/td\u003e\n\u003ctd\u003e±1% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eEnergy Loss\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ei430-Flex 10x\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eDepends on clamp scaling and V nominal\u003c\/td\u003e\n\u003ctd\u003e±1% ±10 counts Excluding line resistance accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eHarmonics\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eHarmonic Order (n)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eDC, 1 to 50 Grouping: Harmonic groups according to IEC 61000-4-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eInter-Harmonic Order (n)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eOFF, 1 to 50 Grouping: Harmonic and Interharmonic subgroups according to IEC 61000-4-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eVolts %\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ef\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±0.1% ±n x 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003er\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±0.1% ±n x 0.4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute\u003c\/td\u003e\n\u003ctd\u003e0.0 to 1000 V\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e±5%\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD\u003c\/td\u003e\n\u003ctd\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±2.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eAmps %\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ef\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±0.1% ±n x 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003er\u003c\/td\u003e\n\u003ctd\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±0.1% ±n x 0.4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute\u003c\/td\u003e\n\u003ctd\u003e0.0 to 600 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±5% ±5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD\u003c\/td\u003e\n\u003ctd\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±2.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eWatts %\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ef or r\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±n x 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute\u003c\/td\u003e\n\u003ctd\u003eDepends on clamp scaling and V nominal\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e±5% ±n x 2% ±10 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHD\u003c\/td\u003e\n\u003ctd\u003e0.0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Angle\u003c\/td\u003e\n\u003ctd\u003e-360° to +0°\u003c\/td\u003e\n\u003ctd\u003e1°\u003c\/td\u003e\n\u003ctd\u003e±n x 1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eFlicker\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ePlt, Pst, Pst (1 min) Pinst\u003c\/td\u003e\n\u003ctd\u003e0.00 to 20.00\u003c\/td\u003e\n\u003ctd\u003e0.01\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eUnbalance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eVolts %\u003c\/td\u003e\n\u003ctd\u003e0.0% to 20.0%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAmps %\u003c\/td\u003e\n\u003ctd\u003e0.0% to 20.0%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eMains Signaling\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eThreshold Levels\u003c\/td\u003e\n\u003ctd\u003eThreshold, limits and signaling duration is programable for two signaling frequencies\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSignaling Frequency\u003c\/td\u003e\n\u003ctd\u003e60 Hz to 3000 Hz\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRelative V %\u003c\/td\u003e\n\u003ctd\u003e0% to 100%\u003c\/td\u003e\n\u003ctd\u003e0.10%\u003c\/td\u003e\n\u003ctd\u003e±0.4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAbsolute V3s (3 second avg.)\u003c\/td\u003e\n\u003ctd\u003e0.0 V to 1000 V\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e±5% of nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eGeneral Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eDesign Rugged, shock proof with integrated protective holster Drip and dust proof IP51 according to IEC60529 when used in tilt stand position Shock and vibration Shock 30 g, vibration: 3 g sinusoid, random 0.03 g 2 \/Hz according to MIL-PRF-28800F Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eBrightness: 200 cd\/m 2 typ. using power adapter, 90 cd\/m 2 typical using battery power Size: 127 x 88 mm (153 mm\/6.0 in diagonal) LCD Resolution: 320 x 240 pixels Contrast and brightness: user-adjustable, temperature compensated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e16GB Wi-Fi SD card for standard models or 8GB SD card for \/INTL models (SDHC compliant, FAT32 formatted), up to 32GB optionally. Screen save and multiple data memories for storing data including recordings (dependent on memory size).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal-Time Clock\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eTime and date stamp for Trend mode, Transient display, System Monitor and event capture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"5\"\u003eEnvironmental\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0°C ~ +40°C; +40°C ~ +50°C excl. battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-20°C ~ +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e+10°C ~ +30°C: 95% RH non-condensing\u003cbr\u003e+30°C ~ +40°C: 75% RH non-condensing\u003cbr\u003e+40°C ~ +50°C: 45% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Altitude\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eUp to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V\u003cbr\u003eUp to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V\u003cbr\u003eMaximum storage altitude 12 km (40,000 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectro-Magnetic-Compatibility (EMC)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eEN 61326 (2005-12) for emission and immunity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaces\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eMini-USB-B, Isolated USB port for PC connectivity SD card slot accessible behind instrument battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eThree years (parts and labor) on main instrument, one year on accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\u003csmall\u003e1. ±5% if ≥ 1% of nominal voltage ±0.05% of nominal voltage if \u0026lt; 1% of nominal voltage\u003cbr\u003e2. 50Hz\/60Hz nominal frequency according to IEC 61000-4-30\u003cbr\u003e3. 400Hz measurements are not supported for Flicker, Mains Signaling and Monitor Mode\u003cbr\u003e4. For nominal voltage 50 V to 500 V\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504304992341,"sku":"Fluke 438-II","price":4379716.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/fluke-438-ii-basic-three-phase-power-quality-and-motor-analyzer-without-current-flexis-excludes-fc-wifi-sd-card.jpg?v=1598947432","url":"https:\/\/www.gilautomation.com\/pt-ao\/products\/fluke-438-ii-power-quality-motor-analyzer","provider":"gilautomation","version":"1.0","type":"link"}