{"product_id":"fluke-750p31-pressure-module-0-700-bar","title":"Fluke 750P31 Pressure Module (0 - 700  bar)","description":"\u003ch2 data-mce-fragment=\"1\"\u003eProduct overview: Fluke 750P Series Pressure Modules\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\" data-mce-fragment=\"1\"\u003e\n\u003cdiv id=\"product-overview\" data-mce-fragment=\"1\"\u003e\n\u003cdiv id=\"overview_content\" data-mce-fragment=\"1\" itemprop=\"description\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003eFluke 750P Series Pressure Modules will turn your\u003cspan data-mce-fragment=\"1\"\u003e Fluke multifunction calibrator\u003c\/span\u003e\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003einto a full-fledged pressure calibrator. These flexible modules not only work with multifunction calibrators like the 725, 726 or 750 Series Calibrators but also extend the measurement range of Fluke pressure calibrators. Since the pressure modules are calibrated independently, they can be swapped from one calibrator to another without a loss of accuracy or traceability.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eMeasuring pressure with Fluke 750P Series Pressure modules is as easy as connecting the module to a pressure source or hand pump, connecting the pressure module cable to the calibrator and then applying pressure from the pressure source. At the touch of a button the measured pressure is displayed digitally on the calibrator in up to 11 different engineering units quickly giving you the data you need. And, with “no tools required” connectors you don’t even need to reach for a wrench to make connections.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWhen used with the 750 Series Documenting Process Calibrators pressure readings can even be date\/time stamped and stored in documented calibration records for later retrieval. This saves time, eliminates errors, and supports compliance with quality standards and regulations.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eA complete family of pressure modules\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWith over 50 pressure modules covering pressure calibration and measurement workloads from 1 inH20 to 10,000 psi (2.5 mbar to 690 bar) finding a model to meet the needs of your specific application is easier than ever. All modules include NPT, metric (BSP) and M20 adapters.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eChoose from:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDifferential modules\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eGage modules\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eHigh pressure modules\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eAbsolute modules\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVacuum modules\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eDual range modules\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eReference modules\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eIntrinsically safe modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWith more than 50 pressure modules to choose from, some of the more popular modules include:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFluke 750P00\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFluke 750P02\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFluke 750PD2\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFluke 750P03\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFluke 750P05\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFluke 750P06\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFluke 750P29\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003eClick the Models tab above for a full list of pressure modules.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eDesigned to go where you work\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePressure instruments are often installed in harsh, hard to reach locations, so you need test tools that handle rough service. 750P Series Pressure Modules feature a rugged protective boot that guards the module against shock and seals against dirt and dust, if you accidently drop them, there’s no need to worry. The 750P series modules are also specified across a broad temperature range. Though more accurate across a narrower temperature range if used indoors, these modules are designed and specified to deliver traceable pressure measurements in environments from -10 °C to +50 °C.\u003c\/p\u003e\n\u003ch2\u003eSpecifications: Fluke 750P Series Pressure Modules\u003c\/h2\u003e\n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"6\" style=\"width: 483px;\"\u003eHigh Pressure Module Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 49px;\"\u003eModel\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 186px;\"\u003e\u003cb\u003eParameter \/ range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 82px;\"\u003e\u003cb\u003eBurst rating\u003csup\u003e6\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e\u003cb\u003eHi side media\u003csup\u003e2\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e\u003cb\u003eLo side media\u003csup\u003e2\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 49px;\"\u003e750P29\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 186px;\"\u003e0 to 3000 psi (0 to 200 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 82px;\"\u003e3X\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 49px;\"\u003e750P30\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 186px;\"\u003e0 to 5000 psi (0 to 340 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 82px;\"\u003e3X\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 49px;\"\u003e750P31\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 186px;\"\u003e0 to 10000 psi (0 to 700 bar)\u003c\/td\u003e\n\u003ctd style=\"width: 82px;\"\u003e2X\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e316 SS\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 49px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 91.6667px;\"\u003e\u003cb\u003eReference uncertainty\u003csup\u003e4\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 94.3333px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e1-year\u003cbr\u003e(15-35°C)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 82px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e1-year\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e6-month\u003cbr\u003e(15-35°C)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e\u003cb\u003eTotal uncertainty\u003cbr\u003e6-month\u003csup\u003e1\u003c\/sup\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 49px;\"\u003e750P29\u003c\/td\u003e\n\u003ctd style=\"width: 91.6667px;\"\u003e±0.0175%\u003c\/td\u003e\n\u003ctd style=\"width: 94.3333px;\"\u003e±0.035%\u003c\/td\u003e\n\u003ctd style=\"width: 82px;\"\u003e±0.045%\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e±0.04%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 49px;\"\u003e750P30\u003c\/td\u003e\n\u003ctd style=\"width: 91.6667px;\"\u003e±0.0175%\u003c\/td\u003e\n\u003ctd style=\"width: 94.3333px;\"\u003e±0.035%\u003c\/td\u003e\n\u003ctd style=\"width: 82px;\"\u003e±0.045%\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e±0.04%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 49px;\"\u003e750P31\u003c\/td\u003e\n\u003ctd style=\"width: 91.6667px;\"\u003e±0.0175%\u003c\/td\u003e\n\u003ctd style=\"width: 94.3333px;\"\u003e±0.035%\u003c\/td\u003e\n\u003ctd style=\"width: 82px;\"\u003e±0.045%\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e±0.03%\u003c\/td\u003e\n\u003ctd style=\"width: 83px;\"\u003e±0.04%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e1. Total uncertainty, % of full span for temperature range 0°C to +50°C, one year interval. Total uncertainty, 1.0% of full span for temperature range -10°C to 0°C, one year interval. No 6 month specification available for range -10°C to 0°C. \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e2. “Non-corrosive gasses” indicates Dry air or non-corrosive gas as compatible media. “Stainless Steel 316-SS” indicates media compatible with Type 316 Stainless Steel. \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e3. Specifications % of Full Span unless otherwise noted. \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e4. Reference Uncertainty is the specification for as left data for 24 hours. \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e5. When reference class modules are used with fixed resolution products (717, 718, 719 series, 725 and 726) calibrators add ±1 count to the overall accuracy specification. \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e6. Burst rating specification refers to the multiplier times full scale of the module for the rated burst pressure. \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e7. Intrinsically Safe pressure module available in this pressure range.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003eA complete family of precision pressure modules\u003c\/li\u003e\n\u003cli\u003eCovers workloads from 1 inH20 to 10,000 psi (2.5 mbar to 690 bar)\u003c\/li\u003e\n\u003cli\u003e8 intrinsically safe models for use with Fluke 718EX or 725EX\u003c\/li\u003e\n\u003cli\u003eReduce errors by digitally sending measurements to calibrators\u003c\/li\u003e\n\u003cli\u003ePrecision measurements with reference uncertainties up to 0.01%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504317182037,"sku":"Fluke 750P31","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/7506_1fc93647-6d8c-421c-abbd-9529cfaee965.jpg?v=1610551576","url":"https:\/\/www.gilautomation.com\/pt-ao\/products\/fluke-750p31-pressure-module-0-700-bar","provider":"gilautomation","version":"1.0","type":"link"}