{"product_id":"fluke-789-e-processmeter","title":"Fluke 789\/E Process Meter","description":"\u003ch2\u003eProduct overview: Fluke 789 ProcessMeter™\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 789 ProcessMeter doubles your troubleshooting power and is Fluke Connect-enabled\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 789 ProcessMeter is the ultimate troubleshooting tool for electricians and instrumentation professionals. It combines the functionality of a loop calibrator with the power of a digital multimeter, and the wireless capabilities of Fluke Connect connectivity with optional IR3000FC module. The 789 has a display that's not only twice as large as the Fluke 787B, but also twice as bright with two levels of backlighting. And its built-in, selectable 250 ohm HART® resistor eliminates the need to carry a separate resistor.\u003c\/p\u003e\n\u003cp\u003eThe 789 also has a 24-Volt loop supply, which reduces the need to carry a separate power supply when doing offline transmitter testing. You can add an optional temperature measurement module and the wireless data logging capabilities of the\u003cspan\u003e Product overview: Fluke 789 ProcessMeter™\u003cbr data-mce-fragment=\"1\"\u003eFluke 789 ProcessMeter doubles your troubleshooting power and is Fluke Connect-enabled\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eThe Fluke 789 ProcessMeter is the ultimate troubleshooting tool for electricians and instrumentation professionals. It combines the functionality of a loop calibrator with the power of a digital multimeter, and the wireless capabilities of Fluke Connect connectivity with optional IR3000FC module. The 789 has a display that's not only twice as large as the Fluke 787B, but also twice as bright with two levels of backlighting. And its built-in, selectable 250 ohm HART® resistor eliminates the need to carry a separate resistor.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eThe 789 also has a 24-Volt loop supply, which reduces the need to carry a separate power supply when doing offline transmitter testing. You can add an optional temperature measurement module and the wireless data logging capabilities of the Fluke Connect™ mobile app to log data wirelessly to your smart phone and review it from a remote location. So now process technicians can do a lot more while carrying a lot less.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eOther useful features:\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eIncludes 0% and 100% buttons to toggle between 4 and 20 mA sourcing for a quick span check\u003cbr data-mce-fragment=\"1\"\u003eProvides all standard DMM capabilities including frequency measurement to 20 kHz, Min\/Max\/Average\/Hold\/Relative modes, and diode test and continuity beeper\u003cbr data-mce-fragment=\"1\"\u003eSimultaneous displays mA and % of scale readings\u003cbr data-mce-fragment=\"1\"\u003eProvides 20 mA DC current source\/loop calibrator\/simulator\u003cbr data-mce-fragment=\"1\"\u003eOffers manual step (100%, 25%, Coarse, Fine) plus auto step and auto ramp\u003cbr data-mce-fragment=\"1\"\u003eDelivers 0.1% dc voltage accuracy and 0.05% dc current accuracy\u003cbr data-mce-fragment=\"1\"\u003eProvides 1200 ohm drive capability on mA source\u003cbr data-mce-fragment=\"1\"\u003eOffers HART mode setting with loop power and a built-in 250 ohm resistor\u003cbr data-mce-fragment=\"1\"\u003eOffers externally accessible fuses and batteries for easy replacement\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eto log data wirelessly to your smart phone and review it from a remote location. So now process technicians can do a lot more while carrying a lot less.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes 0% and 100% buttons to toggle between 4 and 20 mA sourcing for a quick span check\u003c\/li\u003e\n\u003cli\u003eProvides all standard DMM capabilities including frequency measurement to 20 kHz, Min\/Max\/Average\/Hold\/Relative modes, and diode test and continuity beeper\u003c\/li\u003e\n\u003cli\u003eSimultaneous displays mA and % of scale readings\u003c\/li\u003e\n\u003cli\u003eProvides 20 mA DC current source\/loop calibrator\/simulator\u003c\/li\u003e\n\u003cli\u003eOffers manual step (100%, 25%, Coarse, Fine) plus auto step and auto ramp\u003c\/li\u003e\n\u003cli\u003eDelivers 0.1% dc voltage accuracy and 0.05% dc current accuracy\u003c\/li\u003e\n\u003cli\u003eProvides 1200 ohm drive capability on mA source\u003c\/li\u003e\n\u003cli\u003eOffers HART mode setting with loop power and a built-in 250 ohm resistor\u003c\/li\u003e\n\u003cli\u003eOffers externally accessible fuses and batteries for easy replacement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv aria-expanded=\"true\" data-readmore=\"\" id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003eUltimate troubleshooting tool for electricians and instrumentation professionals\u003c\/li\u003e\n\u003cli\u003eCombines the functionality of a loop calibrator with the power of a precision 1000 V, 440 mA True-RMS digital multimeter\u003c\/li\u003e\n\u003cli\u003eOptional IR3000FC module for wireless data logging capabilities via Fluke Connect® mobile App\u003c\/li\u003e\n\u003cli\u003eIncludes 24 V loop power supply\u003c\/li\u003e\n\u003cli\u003eFeatures a very large dual display with enhanced two-level backlight brightness settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications: Fluke 789 ProcessMeter™\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-specs\"\u003e\n\u003cdiv id=\"product-specs\"\u003e\n\u003cdiv id=\"specification_content\"\u003e\n\u003cdiv class=\"clickability\"\u003e\n\u003ctable style=\"width: 528px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\" class=\"head\" style=\"width: 504px;\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\" style=\"width: 148px;\"\u003eCurrent measurement\u003c\/td\u003e\n\u003ctd style=\"width: 161.667px;\"\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 194.333px;\"\u003e0-1 A AC or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 194.333px;\"\u003e1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 194.333px;\"\u003e0.2% + 2 LSD (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eRange\u003c\/td\u003e\n\u003ctd style=\"width: 194.333px;\"\u003e0-30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 194.333px;\"\u003e0.001 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 194.333px;\"\u003e0.05% + 2 lSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 148px;\"\u003eCurrent sourcing\u003c\/td\u003e\n\u003ctd style=\"width: 161.667px;\"\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 194.333px;\"\u003e0-20 mA or 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 194.333px;\"\u003e0.05% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eDrive capability\u003c\/td\u003e\n\u003ctd style=\"width: 194.333px;\"\u003e24 V Compliance or 1200 Ω @ 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 148px;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356px;\"\u003eto 19.999 kHz, 0.005% + 1 LSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 148px;\"\u003eContinuity\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356px;\"\u003eBeeps for resistance \u0026lt; 100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" style=\"width: 148px;\"\u003eVoltage measurement\u003c\/td\u003e\n\u003ctd style=\"width: 161.667px;\"\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 194.333px;\"\u003e0-1000 V AC (true-rms) or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 194.333px;\"\u003e0.1 mV to 1.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 161.667px;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 194.333px;\"\u003e0.1% Rdg + 1 LSD (VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 148px;\"\u003eResistance measurement\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356px;\"\u003eto 40 MΩ, 0.2% + 1 LSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 148px;\"\u003eDiode test\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356px;\"\u003e2.0 V shoes diode voltage drop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 148px;\"\u003eDisplay current and % of span\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 148px;\"\u003eAuto Step, Auto Ramp\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 148px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356px;\"\u003e-20°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 148px;\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356px;\"\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 148px;\"\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356px;\"\u003e95% up to 30°C\u003cbr\u003e75% up to 40°C\u003cbr\u003e45% up to 50°C\u003cbr\u003e35% up to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 148px;\"\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356px;\"\u003e0.05 x (specified accuracy) per °C (for temperatures \u0026lt; 18°C or \u0026gt; 28°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eSafety Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 148px;\"\u003eElectrical safety\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356px;\"\u003eDesigned in accordance with IEC 1010-1, ANSI\/ISA S82.01-1994 and CAN\/CSA C22.2 No 1010.1-92\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 148px;\"\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356px;\"\u003eIEC 1010-1 CAT III 1000 V\u003cbr\u003eIEC 1010-1 CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 148px;\"\u003eMaximum voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356px;\"\u003e1000 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\" style=\"width: 504px;\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 148px;\"\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356px;\"\u003e50 x 100 x 203 mm (1.25 x 3.41 x 7.35 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 148px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356px;\"\u003e610 g (1.6 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 148px;\"\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356px;\"\u003e4 AA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 148px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356px;\"\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 148px;\"\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356px;\"\u003e140 hours typical (measurement), 10 hours typical (sourcing 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 148px;\"\u003eShock and vibration\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"width: 356px;\"\u003eRandom, 2 g, 5-500 Hz\u003cbr\u003e1 meter drop test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Fluke","offers":[{"title":"Default Title","offer_id":32504315379797,"sku":"Fluke 789\/E","price":0.0,"currency_code":"NGN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0267\/8269\/5509\/products\/R4477707-01.jpg?v=1601972234","url":"https:\/\/www.gilautomation.com\/pt-ao\/products\/fluke-789-e-processmeter","provider":"gilautomation","version":"1.0","type":"link"}