Product overview: Fluke 175 True-RMS Digital Multimeter
Fluke 175 is the baseline for industrial measurements
The Fluke 175 True RMS Digital Multimeter delivers the baseline general purpose features required by professional technicians around the world. You can find problems fast with all the basic troubleshooting measurements such as frequency, capacitance, resistance, continuity, and diode. And Display Hold and Auto Hold will help you capture significant events.
Safety rated for industrial use
All inputs on the 175 are protected to IEN61010-1 CAT IV 600 V/CAT III 1000 V. UL, CSA, TÜV listed. You can rely on the Fluke 175 for accurate, true-RMS readings through years of reliable service.
Other useful features:
- Safety rated CAT III 1000 V, CAT IV 600 V
- Comes with a lifetime warranty
- Allows closed-case calibration through front panel
- Includes ergonomic case with integrated protective holster
Key features
- Provides the baseline multimeter features you need for troubleshooting and repairing electrical and electronic systems
- Delivers accurate true-RMS AC current and voltage plus frequency, capacitance, resistance, continuity and diode measurements
- Increases productivity with manual and automatic ranging, Display Hold, Auto Hold, and Min/Max-average recording
Specifications: Fluke 175 True-RMS Digital Multimeter
Specifications | ||
Voltage DC | Accuracy1 | ±(0.15% + 2) |
Max. resolution | 0.1 mV | |
Maximum | 1000 V | |
Voltage AC | Accuracy1 | ±(1.0% + 3) |
Max. resolution | 0.1 mV | |
Maximum | 1000 V | |
Current DC | Accuracy1 | ±(1.0% + 3) |
Max. resolution | 0.01 mA | |
Maximum | 10 A | |
Current AC | Accuracy1 | ±(1.5% + 3) |
Max. resolution | 0.01 mA | |
Maximum | 10 A | |
Resistance | Accuracy1 | ±(0.9% + 1) |
Max. resolution | 0.1 Ω | |
Maximum | 50 MΩ | |
Capacitance | Accuracy1 | ±(1.2% + 2) |
Max. resolution | 1 nF | |
Maximum | 10,000 µF | |
Frequency | Accuracy1 | ±(0.1% + 1) |
Max. resolution | 0.01 Hz | |
Maximum | 100 kHz | |
1. Accuracies are best accuracies for each function | ||
Environmental Specifications | ||
Operating temperature | -10°C to +50°C | |
Storage temperature | -30°C to +60°C | |
Humidity (without condensation) | 0% – 90% (0°C – 35°C) 0% – 70% (35°C – 50°C) |
|
Safety Specifications | ||
Overvoltage category | EN 61010–1 to 1000 V CAT III EN 61010–1 to 600 V CAT IV |
|
Agency approvals | UL, CSA, TÜV listed | |
Mechanical and General Specifications | ||
Size | 43 x 90 x 185 mm | |
Weight | 420 g | |
Warranty | Lifetime | |