Description
Schneider Electric LC1D40AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 220 V AC 50/60 Hz coil
range | TeSys TeSys Deca |
---|---|
product name | TeSys D TeSys Deca |
product or component type | Contactor |
device short name | LC1D |
contactor application | Resistive load Motor control |
utilisation category | AC-4 AC-1 AC-3 AC-3e |
poles description | 3P |
power pole contact composition | 3 NO |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC |
[Ie] rated operational current | 60 A (at <60 ?C) at <= 440 V AC AC-1 for power circuit 40 A (at <60 ?C) at <= 440 V AC AC-3 for power circuit 40 A (at <60 ?C) at <= 440 V AC AC-3e for power circuit |
motor power kW | 18.5 kW at 380...400 V AC 50/60 Hz (AC-3) 11 kW at 220...230 V AC 50/60 Hz (AC-3) 22 kW at 415...440 V AC 50/60 Hz (AC-3) 22 kW at 500 V AC 50/60 Hz (AC-3) 30 kW at 660...690 V AC 50/60 Hz (AC-3) 9 kW at 400 V AC 50/60 Hz (AC-4) 18.5 kW at 380...400 V AC 50/60 Hz (AC-3e) 11 kW at 220...230 V AC 50/60 Hz (AC-3e) 22 kW at 415...440 V AC 50/60 Hz (AC-3e) 22 kW at 500 V AC 50/60 Hz (AC-3e) 30 kW at 660...690 V AC 50/60 Hz (AC-3e) |
motor power HP (UL / CSA) | 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors 3 hp at 115 V AC 50/60 Hz for 1 phase motors 30 hp at 460/480 V AC 50/60 Hz for 3 phases motors |
control circuit type | AC at 50/60 Hz |
[Uc] control circuit voltage | 220 V AC 50/60 Hz |
auxiliary contact composition | 1 NO + 1 NC |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
overvoltage category | III |
[Ith] conventional free air thermal current | 10 A (at 60 ?C) for signalling circuit 60 A (at 60 ?C) for power circuit |
Irms rated making capacity | 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 800 A at 440 V for power circuit conforming to IEC 60947 |
rated breaking capacity | 800 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current | 320 A 40 ?C - 10 s for power circuit 720 A 40 ?C - 1 s for power circuit 72 A 40 ?C - 10 min for power circuit 165 A 40 ?C - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit |
associated fuse rating | 10 A gG for signalling circuit conforming to IEC 60947-5-1 80 A gG at <= 690 V coordination type 1 for power circuit 80 A gG at <= 690 V coordination type 2 for power circuit |
average impedance | 1.5 mOhm - Ith 60 A 50 Hz for power circuit |
[Ui] rated insulation voltage | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 |
electrical durability | 1.4 Mcycles 60 A AC-1 at Ue <= 440 V 1.5 Mcycles 40 A AC-3 at Ue <= 440 V 1.5 Mcycles 40 A AC-3e at Ue <= 440 V |
power dissipation per pole | 2.4 W AC-3 5.4 W AC-1 2.4 W AC-3e |
Front cover | With |
mounting support | Plate Rail |
standards | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 IEC 60335-1 |
product certifications | CCC GOST UL CSA |
connections - terminals | Control circuit: screw clamp terminals 2 cable(s) 1??.5 mm?flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1?? mm?flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1?? mm?flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1?? mm?flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1?? mm?solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1?? mm?solid without cable end Power circuit: EverLink BTR screw connectors 1 cable(s) 1??5 mm?flexible without cable end Power circuit: EverLink BTR screw connectors 2 cable(s) 1??5 mm?flexible without cable end Power circuit: EverLink BTR screw connectors 1 cable(s) 1??5 mm?flexible with cable end Power circuit: EverLink BTR screw connectors 2 cable(s) 1??5 mm?flexible with cable end Power circuit: EverLink BTR screw connectors 1 cable(s) 1??5 mm?solid without cable end Power circuit: EverLink BTR screw connectors 2 cable(s) 1??5 mm?solid without cable end |
tightening torque | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat ? 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25??5 mm? hexagonal screw head 4 mm Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1??5 mm? hexagonal screw head 4 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 |
operating time | 4...19 ms opening 12...26 ms closing |
safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
mechanical durability | 6 Mcycles |
maximum operating rate | 3600 cyc/h 60 ?C |
coil technology | Without built-in suppressor module |
---|---|
control circuit voltage limits | 0.3...0.6 Uc (-40??0 ?C):drop-out AC 50/60 Hz 0.8...1.1 Uc (-40??0 ?C):operational AC 50 Hz 0.85...1.1 Uc (-40??0 ?C):operational AC 60 Hz 1...1.1 Uc (60??0 ?C):operational AC 50/60 Hz |
inrush power in VA | 140 VA 60 Hz cos phi 0.75 (at 20 ?C) 160 VA 50 Hz cos phi 0.75 (at 20 ?C) |
hold-in power consumption in VA | 13 VA 60 Hz cos phi 0.3 (at 20 ?C) 15 VA 50 Hz cos phi 0.3 (at 20 ?C) |
heat dissipation | 4?? W at 50/60 Hz |
auxiliary contacts type | Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1 |
signalling circuit frequency | 25...400 Hz |
minimum switching current | 5 mA for signalling circuit |
minimum switching voltage | 17 V for signalling circuit |
non-overlap time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
insulation resistance | > 10 MOhm for signalling circuit |
IP degree of protection | IP20 front face conforming to IEC 60529 |
---|---|
climatic withstand | Conforming to IACS E10 conforming to IEC 60947-1 Annex Q category D |
protective treatment | TH conforming to IEC 60068-2-30 |
pollution degree | 3 |
ambient air temperature for operation | -40??0 ?C 60??0 ?C with derating |
ambient air temperature for storage | -60??0 ?C |
operating altitude | 0...3000 m |
fire resistance | 850 ?C conforming to IEC 60695-2-1 |
mechanical robustness | Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 10 Gn for 11 ms |
height | 122 mm |
width | 55 mm |
depth | 120 mm |
net weight | 0.85 kg |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Weight | 915.0 g |
Package 1 Height | 6.2 cm |
Package 1 width | 13.5 cm |
Package 1 Length | 15.2 cm |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 10 |
Package 2 Weight | 9.776 kg |
Package 2 Height | 15.0 cm |
Package 2 width | 30.0 cm |
Package 2 Length | 40.0 cm |
Unit Type of Package 3 | P06 |
Number of Units in Package 3 | 160 |
Package 3 Weight | 164.9 kg |
Package 3 Height | 77.0 cm |
Package 3 width | 80.0 cm |
Package 3 Length | 60.0 cm |
Warranty | 18 months |
---|
Sustainability
Estimate shipping
Refund Policy
We have a 30-day return policy, which means you have 30 days after receiving your item to request a return.
To be eligible for a return, your item must be in the same condition that you received it, unworn or unused, with tags, and in its original packaging. You’ll also need the receipt or proof of purchase.
To start a return, you can contact us at info@gilautomation.com. If your return is accepted, we’ll send you a return shipping label, as well as instructions on how and where to send your package. Items sent back to us without first requesting a return will not be accepted.
You can always contact us for any return question at info@gilautomation.com.
Damages and issues
Please inspect your order upon reception and contact us immediately if the item is defective, damaged or if you receive the wrong item, so that we can evaluate the issue and make it right.
Exceptions / non-returnable items
Certain types of items cannot be returned, like perishable goods (such as food, flowers, or plants), custom products (such as special orders or personalized items), and personal care goods (such as beauty products). We also do not accept returns for hazardous materials, flammable liquids, or gases. Please get in touch if you have questions or concerns about your specific item.
Unfortunately, we cannot accept returns on sale items or gift cards.
Exchanges
The fastest way to ensure you get what you want is to return the item you have, and once the return is accepted, make a separate purchase for the new item.
Refunds
We will notify you once we’ve received and inspected your return, and let you know if the refund was approved or not. If approved, you’ll be automatically refunded on your original payment method. Please remember it can take some time for your bank or credit card company to process and post the refund too.